• Title/Summary/Keyword: posterior

Search Result 5,979, Processing Time 0.031 seconds

Comparative study of volumetric change in water-stored and dry-stored complete denture base (공기중과 수중에서 보관한 총의치 의치상의 체적변화에 대한 비교연구)

  • Kim, Jinseon;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.18-26
    • /
    • 2021
  • Purpose: Generally, patients are noticed to store denture in water when removed from the mouth. However, few studies have reported the advantage of volumetric change in underwater storage over dry storage. To be a reference in defining the proper denture storage method, this study aims to evaluate the volumetric change and dimensional deformation in case of underwater and dry storage. Materials and methods: Definitive casts were scanned by a model scanner, and denture bases were designed with computer-aided design (CAD) software. Twelve denture bases (upper 6, lower 6) were printed with 3D printer. Printed denture bases were invested and flasked with heat-curing method. 6 upper and 6 lower dentures were divided into group A and B, and each group contains 3 upper and 3 lower dentures. Group A was stored dry at room temperature, group B was stored underwater. Group B was scanned at every 24 hours for 28 days and scanned data was saved as stereolithography (SLA) file. These SLA files were analyzed to measure the difference in volumetric change of a month and Kruskal-Wallis test were used for statistical analysis. Best-fit algorithm was used to overlap and 3-dimensional color-coded map was used to observe the changing pattern of impression surface. Results: No significant difference was found in volumetric changes regardless of the storage methods. In dry-stored denture base, significant changes were found in the palate of upper jaw and posterior lingual border of lower jaw in direction away from the underlying tissue, maxillary tuberosity of upper jaw and retromolar pad area of lower jaw in direction towards the underlying tissue. Conclusion: Storing the denture underwater shows less volumetric change of impression surface than storing in the dry air.

Effect of Nurida-Ball exercise on muscle function, spinal alignment, and dynamic balance capacity in Middle-Aged Men (누리다 볼 운동이 중년 남성의 근기능, 척추정렬 및 동적 균형능력에 미치는 영향)

  • Choi, Dong-Hun;Kim, Tae-Kyung;Park, Jae-Myoung;Jung, Jong-Hwan;Yeom, Dong-Chul;Cho, In-Ho;Cho, Joon-Yong;Koo, Jung-Hoon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.6
    • /
    • pp.1556-1566
    • /
    • 2020
  • The purpose of this study was to investigate the effect of Nurida-Ball exercise on isokinetic muscle function, spinal alignment, and dynamic balance capacity in middle-aged men. All middle-aged men(n=16) were divided into 2 groups: Ball exercise(BE, n=8) and control(CON, n=8) group. BE group performed the Nurida-Ball exercise(30 min/day, 3 days/week, 8 weeks) and isokinetic knee and trunk muscle function, spinal alignment, and dynamic balance capacity were measured. All of the measured variables calculated the mean and standard deviation and verified normality using the Shapiro-Wilk test. The independent t-test method and the Paired t-test method were then analyzed to identify differences between groups. This study found that isokinetic knee and trunk muscle function was significantly strengthened in the BE compared with CON group by increasing peak torque(PT) of right and left knee extension(60°/sec, p<0.01, respectively), average power(AP) of right and left knee extension(60°/sec, p<0.05, p<0.01, respectively), and PT of right knee flexion(180°/sec, p<0.05) and AP of right knee extension(180°/sec, p<0.05). In the change of isokinetic trunk muscle function, only PT of trunk extension(180°/sec) was increased in the BE compared with the CON group(p<0.05). In addition, Nurida-ball exercise can improve the spinal alignment by reducing the trunk inclination(p<0.05) in the BE compared with the CON group. Finally, dynamic balance capacity was also enhanced in the BE compared with the CON group by decreasing the score of overall balance index(OBI, p<0.01) and Antero-posterior balance index(p<0.05) in the Stage-6, and OBI(p<0.05) in the Stage-1. This result demonstrated that Nurida-ball exercise may improve spinal alignment, dynamic balance capacity, and isokinetic muscle function, which might be an effective way for the improvement of health-related fitness in middle-aged men.

The effect of reduced thickness in different regions on the fracture resistance of monolithic zirconia crowns (다양한 부위에서의 감소된 두께가 지르코니아 크라운의 파절 저항에 미치는 영향)

  • Abukabbos, Layla;Park, Je Uk;Lee, Wonsup
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.135-142
    • /
    • 2022
  • Purpose. This study aims to evaluate the combined effect of reduced thickness in different regions on the fracture resistance of monolithic zirconia crowns. Materials and methods. Seven nickel-chromium dies were generated from a 3D model of mandibular first molar using the digital scanner with the following geometries: 1.5 mm occlusal reduction, 1.0 mm deep chamfer. Based on the abutment model, Zirconia blocks (Luxen Zirconia) were selected to fabricate Sixty-three zirconia crowns with occlusal thicknesses of 0.3 mm, 0.5 mm, and 1.5 mm, and different axial thicknesses of 0.3 mm, 0.5 mm, and 1.0 mm. All crowns were cemented by resin cement. Next, the crowns were subjected to load-to-fracture test until fracture using an electronic universal testing machine. In addition, fracture patterns were observed with a scanning electron microscope (SEM). Two-way ANOVA and the Tuckey HSD test for post hoc analysis were used for statistical analysis (P < .05). Results. The mean values of fracture resistancerecorded was higher than the average biting force in the posterior region. The two-way ANOVA showed that the occlusal and axial thickness affected the fracture resistance significantly (P < .05). However, the effect of axial thickness on fracture resistance did not show a statistical difference when thicker than 0.5 mm. The observed failure modes were partial or complete fracture depending on the severity of crack propagation. Conclusion. Within the limitations of the present study, the CAD-CAM monolithic zirconia crown with extremely reduced thickness showed adequate fracture resistance to withstand occlusal load in molar regions. In addition, both occlusal and axial thickness affected the fracture resistance of the zirconia crown and showed different results as combined.

Dual Plate Fixation for Periprosthetic Femur Fracture after Total Knee Arthroplasty (슬관절 전치환술 후 발생한 대퇴골 삽입물 주위 골절의 이중 금속판 고정술)

  • Kim, Dong Hwi;Cha, Dong Hyuk;Ko, Kang Yeol
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.26-33
    • /
    • 2021
  • Purpose: This study evaluated the results of dual plate fixation for periprosthetic femur fracture after total knee arthroplasty (TKA). Materials and Methods: From October 2007 to February 2013, 23 cases of periprosthetic femur fracture after TKA were treated at the author's hospital. There were 13 cases of fixation using a medial and lateral dual plate when the stability of the fracture site could not be achieved by one side fixation with a follow-up of more than one year. The cases included no loosening of the femoral component in fractures that were categorized as Lewis-Rorabeck classification II and supracondylar comminuted fractures and elongation of the fracture line to the lateral epicondyle of the femur or stem in the medullary canal. The mean age was 72 years (65-82 years), and 11 cases were female. Three cases had a stem due to revision. The mean bone marrow density was -3.2 (-1.7 to -4.4), and the mean period from primary TKA to periprosthetic fractures was 28 months (1-108 months). The mean follow-up period was 23 months (12-65 months). The medial fracture site was first exposed via the subvastus approach. Second, the supplementary plate was fixed on the lateral side of the fracture using a minimally invasive plate osteosynthesis technique. The average union time, complications, and Hospital for Special Surgery Knee Score (HSS) at the last follow-up were evaluated. Results: The mean union time was 17.4 weeks (7-40 weeks). Two cases showed delayed bone union and nonunion occurred in one case, in whom bone union was achieved three months later after re-fixation using a dual plate with an autogenous bone graft. The mean varusvalgus angulation was 1.67 degrees (-1.2-4.9 degrees), and the mean anterior-posterior angulation was 2.86 degrees (0-4.9 degrees) at the last follow-up. The mean knee range of motion was 90 degrees, and the HSS score was 85 points (70-95 points) at the last follow-up. Conclusion: Dual plate fixation for periprosthetic femur fractures that had not achieved stability by one side plate fixation after TKA showed a good clinical result that allowed early rehabilitation.

Comparison of the Morphometric Changes in the Cervical Foramen: Anterior Cervical Discectomy and Fusion versus Posterior Foraminotomy (전방 경유 디스크 절제술 및 유합술과 후방 추간공 절제술에서의 경추 추간공의 형태학적 변화 비교)

  • Chung, Sung-Soo;Sun, Woo-Sung;Chung, Jong-Chul;Heo, Ki-Sung;Kim, Hyun-Min
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.6
    • /
    • pp.512-518
    • /
    • 2021
  • Purpose: This study compared the change in foraminal space on magnetic resonance imaging (MRI) and the clinical outcome after anterior cervical discectomy and fusion (ACDF) versus foraminotomy in cervical foraminal stenosis. Materials and Methods: A retrospective case-control study was conducted from January 2018 to March 2019 on 186 patients who underwent ACDF and foraminotomy. One hundred and two cases were selected considering age, sex, and body mass index. MRI was performed before and on the 5th day after surgery to compare the changes in the foraminal diameter between the ACDF group (group A-51) and foraminotomy group (group B-51). Results: Between groups A and B, the average change in foraminal vertical diameter was 1.7 mm and 1.2 mm, respectively; group A was 0.5 mm larger difference (p=0.042). The average change in foraminal transverse diameter was 1.2 mm and 1.8mm, respectively; group B showed a 0.6 mm larger change (p=0.21). Both the neck disability index (NDI) and Japanese orthopaedic association (JOA) scores improved in both groups. Group A showed more improvement, but there was no significant difference (p=0.356, p=0.607, respectively). Conclusion: Foraminotomy is a useful option for patients with foraminal stenosis of the cervical spine because it showed comparable clinical and morphological results to ACDF and could minimize motion segment loss and muscle and ligament damage.

Assessment of the Position of the Mandibular Foramen and Mandibular Lingula in Children and Adolescents using CBCT (소아 청소년에서 하악공 및 하악소설의 위치에 대한 CBCT 분석)

  • Lee, Jihye;Choi, Namki;Kim, Byunggee;Kim, Seonmi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.1
    • /
    • pp.64-76
    • /
    • 2021
  • The purpose of this study is to evaluate the position of the mandibular foramen and location and morphological characteristics of the mandibular lingula using Cone-Beam Computed Tomography (CBCT). Mandibular CBCT images of children aged 6 - 16 years were collected. A total of 180 patients were divided into 3 groups, 6 - 7, 10 - 11 and 15 - 16 years, with 30 male and female patients per group. Either side of the ramus was analyzed. The shortest distances from the anterior, posterior, superior and inferior border of the ramus to the mandibular lingula were measured. The shortest distance between the mandibular lingula and the mandibular foramen was also measured. The vertical distance from the mandibular lingula and the mandibular foramen to the occlusal plane was measured. The shapes of the mandibular lingula was classified into 4 types according to the criteria. The distances of the mandibular lingula from the anteroposterior and vertical reference points of the ramus increased in all directions with age. The distance between the mandibular lingula and the mandibular foramen also increased with age. The location of the mandibular lingula and the mandibular foramen in relation to the occlusal plane moved upwards with age. The most common shape of the mandibular lingula was triangular, followed by nodular, truncated and assimilated, and there was no difference in the shape according to age. It is recommended that the horizontal insertion point of the anesthesia from the anterior border of the ramus increased to 17 mm, 18 mm, and 19 mm according to the age groups. It is also suggested that the vertical insertion point increased by 2 - 3 mm, 5 - 6 mm and 9 - 10 mm above the occlusal plane according to the age groups.

A Study on the Diagnostic Reference Level of Skull Radiography in Digital Radiography (디지털 방사선 환경에서 두부 방사선검사 시 진단참고수준 검사조건에 대한 고찰)

  • Yeon-Jin, Jeong;Young-Cheol, Joo;Dong-Hee, Hong;Sang-Hyeon, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.897-904
    • /
    • 2022
  • The purpose of this study is to compare the difference in dose and image quality when applying the diagnostic reference level (DRL) test conditions for head radiography in a digital radiation environment and the test conditions currently applied in clinical practice. I would like to review the conditions of radiographic examination. In this study, the head model phantom was targeted, and the investigation conditions were divided into clinical conditions (Clinic), DRL value (DRL75), and DRL average value (DRLmean). For dose, Enterance surface dose (ESD) was measured, and for image quality, signal-to-noise ratio and contrast-to-noise ratio were measured and analyzed for comparison. The average values of skull anterior posterior(AP) ESD according to the changes in test conditions were Clinic 1214.03±4.21 µGy, DRL75 3017.83±8.14 µGy, DRLmean 2283.50±7.09 µGy, and skull lateral (Lat). The average value of ESD was statistically significant with Clinic 762.79±3.54 µGy, DRL75 2168.57±10.83 µGy, and DRLmean 1654.43±6.48 µGy (p<0.01). The average values of SNR and CNR measured in the orbital, maxillary sinus, frontal sinus, and sella turcica were statistically significant (p<0.01). As a result of this study, compared to DRL, the conditions used in clinical practice showed lower dose levels of about 58% for AP and about 70% for Lat., and there was no qualitative difference in terms of image quality. Through this study, it is necessary to consider a new diagnostic reference level suitable for the digital radiation environment, and it is considered that the dose should be reduced accordingly.

Study on the Differences in the Results of Body Shape Test According to the Position of the Two Feet and the Usefulness of the Neck and Body Motion Image Test (두 발의 위치에 따른 체형검사 결과 차이와 체간신전 동작 이미지 검사의 유용성 연구)

  • Chang, Wan Song;Kim, Song Ja;Ryu, Seo Won;Lim, Duk Joon;Jung, Moon Young
    • Journal of Naturopathy
    • /
    • v.9 no.1
    • /
    • pp.22-26
    • /
    • 2020
  • Purposes: The purposes of this study were to investigate the relationship between the standing position of the subject and the normal standing position(NSP) and the straight standing position(SSP) and to investigate the possibility of different body shape test results depending on the status of the image inspection apparatus. Methods: The images of the NSP and SSP were compared with each other by body line BLS system. Results: At the time of examination, the position of the camera was captured at a position 2.3 m vertically from the posterior position 45 cm behind the subject. This is a privacy protection method for covering the breast of the subject. Results: The physiological characteristics of the anatomical position of the body align image test are the living body. NSP and SSP tests showed different shapes of the pelvis AS(antero-supero) and pelvis rotation in the transverse plane. Shoulder and arm displacement was observed in the trunk extension image capture. Conclusions: In the body alignment test, the pelvis position test images of NSP and SSP are evaluated differently for pelvis rotation, AS, and PS. At the extension position of the trunk, a test of the maximal extension range showed that the left and right shortening of the shoulder anterior muscles could be observed. Inducing and testing the trunk extension is also useful.

Quantitative Electroencephalogram Markers for Predicting Cerebral Amyloid Pathology in Non-Demented Older Individuals With Depression: A Preliminary Study (비치매 노인 우울증 환자에서 대뇌 아밀로이드 병리 예측을 위한 정량화 뇌파 지표: 예비연구)

  • Park, Seon Young;Chae, Soohyun;Park, Jinsick;Lee, Dong Young;Park, Jee Eun
    • Sleep Medicine and Psychophysiology
    • /
    • v.28 no.2
    • /
    • pp.78-85
    • /
    • 2021
  • Objectives: When elderly patients show depressive symptoms, discrimination between depressive disorder and prodromal phase of Alzheimer's disease is important. We tested whether a quantitative electroencephalogram (qEEG) marker was associated with cerebral amyloid-β (Aβ) deposition in older adults with depression. Methods: Non-demented older individuals (≥ 55years) diagnosed with depression were included in the analyses (n = 63; 76.2% female; mean age ± standard deviation 73.7 ± 6.87 years). The participants were divided into Aβ+ (n = 32) and Aβ- (n = 31) groups based on amyloid PET assessment. EEG was recorded during the 7min eye-closed (EC) phase and 3min eye-open (EO) phase, and all EEG data were analyzed using Fourier transform spectral analysis. We tested interaction effects among Aβ positivity, condition (EC vs. EO), laterality (left, midline, or right), and polarity (frontal, central, or posterior) for EEG alpha band power. Then, the EC-to-EO alpha reactivity index (ARI) was examined as a neurophysiological marker for predicting Aβ+ in depressed older adults. Results: The mean power spectral density of the alpha band in EO phase showed a significant difference between the Aβ+ and Aβ- groups (F = 6.258, p = 0.015). A significant 3-way interaction was observed among Aβ positivity, condition, and laterality on alpha-band power after adjusting for age, sex, educational years, global cognitive function, medication use, and white matter hyperintensities on MRI (F = 3.720, p = 0.030). However, post-hoc analyses showed no significant difference in ARI according to Aβ status in any regions of interest. Conclusion: Among older adults with depression, increased power in EO phase alpha band was associated with Aβ positivity. However, EC-to-EO ARI was not confirmed as a predictor for Aβ+ in depressed older individuals. Future studies with larger samples are needed to confirm our results.

Structural and functional characteristics of rock-boring clam Barnea manilensis (암석을 천공하는 돌맛조개(Barnea manilensis)의 구조 및 기능)

  • Ji Yeong Kim;Yun Jeon Ahn;Tae Jin Kim;Seung Min Won;Seung Won Lee;Jongwon Song;Jeongeun Bak
    • Korean Journal of Environmental Biology
    • /
    • v.40 no.4
    • /
    • pp.413-422
    • /
    • 2022
  • Barnea manilensis is a bivalve which bores soft rocks, such as, limestone or mudstone in the low intertidal zone. They make burrows which have narrow entrances and wide interiors and live in these burrows for a lifetime. In this study, the morphology and the microstructure of the valve of rock-boring clam B. manilensis were observed using a stereoscopic microscope and FE-SEM, respectively. The chemical composition of specific part of the valve was assessed by energy dispersive X-ray spectroscopy (EDS) analysis. 3D modeling and structural dynamic analysis were used to simulate the boring behavior of B. manilensis. Microscopy results showed that the valve was asymmetric with plow-like spikes which were located on the anterior surface of the valve and were distributed in a specific direction. The anterior parts of the valve were thicker than the posterior parts. EDS results indicated that the valve mainly consisted of calcium carbonate, while metal elements, such as, Al, Si, Mn, Fe, and Mg were detected on the outer surface of the anterior spikes. It was assumed that the metal elements increased the strength of the valve, thus helping the B. manilensis to bore sediment. The simulation showed that spikes located on the anterior part of the valve received a load at all angles. It was suggested that the anterior part of the shell received the load while drilling rocks. The boring mechanism using the amorphous valve of B. manilensis is expected to be used as basic data to devise an efficient drilling mechanism.