• 제목/요약/키워드: post-tensioning anchorage

검색결과 21건 처리시간 0.021초

포스트텐션용 정착구의 하중전달 특성에 관한 연구 (Load Transfer Characteristics of Post-Tensioning Anchorage)

  • 김민수;김진근;유영섭;이상순
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.657-662
    • /
    • 2000
  • This paper presents the results from experimental study that investigated to explore the load transfer characteristics of post-tensioning anchorage zones. The experimental program investigated the primary variables which affect the ultimate load, lateral strains and crack width: concrete compressive strength, details of reinforcement and shape of anchorage. Through this research, it was found that the governing factor of the ultimate load was not compressive cylinder strength but tensile splitting strength. Ultimate load was increased and lateral strain was decreased as the ratio of spiral increased because the lateral expansion of th concrete inside the spiral was restrained by the spiral. Furthermore, the shape of anchorage which can diminish the wedge effect of anchorage and disperse the anchorage force in various depths was more effective.

  • PDF

정착방법에 따른 외부 프리스트레이트 도입공법의 보강성능 평가 (Strengthening Evaluation of Post-Tensioning Due to Anchorage System)

  • 박승범;홍석주
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.279-284
    • /
    • 2000
  • The bridge is nation's principal structure and its influence for national economy is enormous. But it is essential for maintenance of deteriorated bridge because of the increased service life and the decreased performance. For the bridge reinforced by continuos slabs and post-tensioning, we evaluate th stress properties of girders and internal support. Results are almost coincidence between measured data in the field and analysed data by computer. We compared the effects by successive order of post- tensioning and order considered distribution of each girder's camber and stress. Bridge's camber and stress showed respectively symmetry and asymmetry shape by post tensioning order. For the effect of post-tensioning force partition, we divided the post-tensioning force into 3 types (100%, 20%, 30%), and the results show t도 difference of final stress and camber.

  • PDF

비부착식 단일 강연선용 포스트텐션 정착구 개발 및 응력해석 (Development and Analysis of Unbonded Post-tensioned Anchorage for Single Tendon)

  • 이영학;조용우;김민숙
    • 한국전산구조공학회논문집
    • /
    • 제31권1호
    • /
    • pp.39-46
    • /
    • 2018
  • 본 논문에서는 상용프로그램을 이용한 유한요소해석을 통하여 포스트텐션 정착구역에서 보다 효율적인 응력분산이 가능한 비부착식 단일 강연선용 포스트텐션 정착구 형상을 개발하는 것을 목표로 하였다. 이를 위하여 정착구 형상을 구성하는 각 부분의 변수해석을 수행하였다. 본 연구에서 제안한 정착구 형상을 사용하였을 때 발생하는 최대파열응력이 기존의 정착구를 사용한 경우와 비교하여 정착구역내의 최대파열응력이 감소함을 확인하였다. 또한 본 연구의 정착구 형상을 사용하는 경우 최대파열응력 산정을 위해 AASHTO 및 기존 연구자들의 파열력 산정식을 통해 산출된 파열력을 비교 및 분석하였다. 그 결과 정착구 형상에 따른 위치계수를 수정한 파열력 산정식을 적용할 경우 정착구역이 효율적인 보강설계가 가능할 것으로 판단되었다.

RC 부재의 휨 보강을 위한 외부 비부착형 탄소섬유판 포스트텐션 시스템 (Post-tensioning System with Externally Unbonded CFRP Strips for Strengthening RC Members)

  • 유영찬;최기선;김긍환
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권6호
    • /
    • pp.147-154
    • /
    • 2008
  • 본 연구에서는 외부 비부착형 프리스트레스트 탄소섬유판으로 보강된 RC보의 휨거동을 분석하기 위한 실험연구를 수행하였다. 실험체는 프리스트레스 양 및 정착장치의 형상을 변수로 총 10개로 제작되었다. 또한 프리스트레스의 도입에 따른 구조성능 비교를 위하여 기준실험체와 단순부착 실험체를 함께 제작하였다. 실험결과, 단순 부착 탄소섬유판으로 보강된 부재는 조기 박리에 의해 탄소섬유판 인장강도의 50% 이하에서 최종파괴되었다. 그러나, 프리스트레스를 도입하여 보강한 실험체는 모두 탄소섬유판의 파단하중까지 도달하였다. 또한 스터드형 정착장치를 적용한 실험체들의 보강성능은 매립형 정착장치를 적용한 실험체와 동등한 보강성능을 나타내었다.

외부 후 긴장 공법을 이용한 강합성보의 보강에 관한 연구 (A Study on the Reinforcement of Steel Composite Beam Using the External Post-Tensioning Method)

  • 박용걸;박영훈;이승용
    • 한국강구조학회 논문집
    • /
    • 제12권5호통권48호
    • /
    • pp.549-558
    • /
    • 2000
  • 외부 후 긴장 공법은 설계에 수반되는 구조해석이 비교적 명확하여 강교량 구조물뿐만 아니라 건축구조물 등 그 적용 범위가 매우 넓은 보강방법이다. 본 연구에서는 후 긴장 공법에 있어서 긴장력 도입 과정의 강합성보의 거동을 연구하기 위하여 긴장력 증가에 따른 긴장재, 경간 중앙부 하부 플랜지, 정착단 주형 하부 플랜지의 도입 변형율과 긴장재 절곡 각도에 따른 도입 전단력 및 압축력을 실험 및 해석적으로 분석하였다. 또한 긴장력 도입 후 정적 휨 재하 실험을 수행하여 긴장력 도입 정도에 따른 휨 보강 정도를 분석하였으며, 절곡 각도의 변화에 따른 전단보강 및 휨 보강 양상을 연구하였다. 그 결과 외부 후 긴장력 도입에 따른 휨 보강 효과가 매우 높은 것으로 분석되었으며, 긴장재의 절곡 배치에 의해서는 추가적으로 전단보강 효과까지 나타났다.

  • PDF

나선형 원형철근으로 보강된 집중배치 텐던 정착구역에 대한 하중전달시험 (Load Transfer Test of Spirally Reinforced Anchorage Zone for Banded Tendon Group)

  • 조아서;강현구
    • 한국공간구조학회논문집
    • /
    • 제17권1호
    • /
    • pp.59-67
    • /
    • 2017
  • In this study, load transfer tests based on KCI-PS101 were conducted to verify the performance of spiral anchorage zone reinforcement for banded post-tensioning (PT) monostrands. With results, the compressive strength of spiral reinforcement was increased by about 20% than that of specimens with two horizontal steel bars and 8% than that of U-shaped bars. Advanced spiral reinforcement for corner increases compressive strength and can resist the spalling forces or fall-out effect at the corner by shear. The ratio of maximum load to amount of steel of the spiral reinforcement is about twice than that of U-shaped reinforcement. With increase of compressive strength capacity and improvement of constructability, the spiral reinforcement is considered to have advantages of promoting the performance of PT anchorage zone compared to conventional methods.

Influence of steel fiber and reinforcing details on the ultimate bearing strength of the post-tensioning anchorage zone

  • Kim, Jin-Kook;Yang, Jun-Mo;Kwon, Yangsu
    • Structural Engineering and Mechanics
    • /
    • 제59권5호
    • /
    • pp.867-883
    • /
    • 2016
  • In this paper, the effects of steel-fiber and rebar reinforcements on the ultimate bearing strength of the local anchorage zone were investigated based on experiments and comparisons between test results and design-equation predictions (AASHTO 2012, NCHRP 1994). Eighteen specimens were fabricated using the same anchorage device, which is one of the conventional anchorage devices, and two transverse ribs were used to secure an additional bearing area for a compact anchorage-zone design. Eight of the specimens were reinforced with only steel fiber and are of two concrete strengths, while six were reinforced with only rebars for two concrete strengths. The other four specimens were reinforced with both rebars and steel fiber for one concrete strength. The test and the comparisons between the design-equation predictions and the test results showed that the ultimate bearing strength and the section efficiency are highly affected by the reinforcement details and the concrete strength; moreover, the NCHRP equation can be conservatively applied to various local anchorage zones for the prediction of the ultimate bearing strength, whereby conditions such as the consideration of the rib area and the calibration factor are changed.

2400MPa 단일 강연선이 적용된 포스트텐션 정착 구역 설계에 대한 실험적 연구 (Experimental Analysis of Anchorage Zone Design for Unbonded Post-Tensioned Concrete Beam With 2400MPa Single Tendons)

  • 문상필;노경민;김민숙;이영학
    • 한국공간구조학회논문집
    • /
    • 제20권1호
    • /
    • pp.41-48
    • /
    • 2020
  • In this study, the design of anchorage zone for unbonded post-tensioned concrete beam with single tendons of ultimate strength 2400MPa was evaluated to verify that the KDS 14 20 60(2016) and KHBDC 2010 codes are applicable. The experimental results showed that the bursting force equation of current design codes underestimated bursting stress measured by test, because the KDS 14 20 60(2016) and KHBDC 2010 propose the location of the maximum bursting force 0.5h which is the half of the height of member regardless of stress contribution. Although the allowable bearing force calculated by current design codes was not satisfied the prestressing force, the cracks and failure in anchorage zone was not observed due to the strengthening effect of anchorage zone reinforcement.

비부착 포스트텐션 정착구역 설계를 위한 파열력 산정 방법 (Bursting Force Equation for Design in Unbonded Post-Tensioned Anchorage Zone)

  • 노경민;이영학
    • 대한건축학회논문집:구조계
    • /
    • 제34권12호
    • /
    • pp.21-26
    • /
    • 2018
  • For evaluating equations of bursting force in different codes, comparative study of the formulas was conducted. Because the equations does not consider variables such as shape of anchorages and duct, a relation between the bursting forces and the variables has to be analyzed. In this paper, the bursting forces equation was proposed by finite element analysis. As evaluation through comparison of the proposed equation with the previous ones and an experiment, it was figured out that bursting force computed by the proposed equation could be used for design of reinforcement in the anchorage zone.

2,400 MPa 강연선용 포스트텐션 정착구의 하중전달성능 (The Load Transfer Performance of Post-tension Anchorage with 2,400 MPa Strands)

  • 김선우;노병철;임정훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권6호
    • /
    • pp.63-71
    • /
    • 2018
  • 인장강도가 2,400 MPa인 강연선이 개발되어 콘크리트구조기준 및 KS 규격에 반영되었다. 고강도 프리스트레스트 강연선이 구조물에 적용되기 위해서는 그에 적합한 정착시스템이 함께 사용되어야 한다. 최근에 2,400 MPa 강연선 적용을 위한 포스트텐션 정착구의 개발이 진행되어왔으나, 성능평가에 대한 연구가 미비한 실정이다. 따라서 본 연구에서는 2,400 MPa 강연선을 적용한 포스트텐션 정착구 중 가장 활용도가 높은 9 가닥, 15 가닥, 19 가닥 정착구에 대하여 PTI의 Anchorage Design Zone에 의한 국소구역 구조검토를 실시하였고, ETAG013 및 KCI-PS101에 의한 하중전달성능평가를 수행하였다. 또한 비선형 수치해석을 통해 시험의 적절성을 분석하였다. 그 결과, 2,400 MPa 정착구는 국소구역의 구조성능을 만족하고, 하중전달성능 조건을 만족하는 것으로 나타났다.