• 제목/요약/키워드: post-curing

검색결과 138건 처리시간 0.022초

Photopolymer Composed of a Photosensitive Polymer Binder Bearing a Chalcone Moiety in the Repeating Unit

  • Cho, Min-Ju;Yoon, Hyuk;Feng, Dejun;Yoon, Han-na;Choi, Dong-Hoon
    • Journal of Information Display
    • /
    • 제7권2호
    • /
    • pp.6-11
    • /
    • 2006
  • New photopolymers were designed and prepared using the photosensitive polymer binders. Holographic gratings were successfully fabricated in these photopolymer samples by a conventional optical interference method. We also investigated the effect of photocrosslink in the polymer binder on the diffraction behavior of a new photopolymer. The dynamic behavior of the grating formation was monitored by changing exposure intensity in terms of the diffraction efficiency. Particularly, we focused our efforts in observing the variation of diffraction efficiency during a post UV curing process. The surface topographical change of photopolymer layer before and after Vis/UV light exposure was observed by atomic force microscope (AFM). We inscribed the gratings of the glass diffuser on the surface of the photopolymer and investigated their diffusing properties. The diffusers with photopolymer with the main chain polymer binder showed relatively good viewing angle of around ${\pm}30{\circ}$. Two kinds of photopolymer showed similar uniformity of around 47-54%.

유도가열 및 근적외선 가열방법에 의한 표면처리 강판 도포층의 가열 및 건조 특성 (Heating & Drying Characteristics of Coating Layer by Induction Heating and Short-wave Infrared Heating)

  • 김태수;양재원
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2004년도 제5회 압연심포지엄 신 시장 개척을 위한 압연기술
    • /
    • pp.249-257
    • /
    • 2004
  • Drying and curing characteristics of PCM resins using the induction heater and short-wave infrared emitter module was studied to develop a compact oven system for the high speed CCL and post-treatment equipment. Drying of the polyester resins using the induction heater and infrared heater showed that the blistering tendency of polyester resin coating increased regardless of additives and colors of resins as the heating rate and/or dry film thickness increased. The blistering of polyester resin coating layer occurred when the heating speed was over than $25^{\circ}C/sec$ for the dry film thickness of $19\~20um$, which is the typical thickness of finish coating in CCL. So did it when the heating speed was over than $40^{\circ}C/sec$ for the dry film thickness over than 10 um. The heating efficiency of paint coated steels by the infrared heating was strongly dependent on the colors of paint coating and generally increased for the dark surface and/or coating. But the faster drying of the PCM resin coatings increased the blistering tendency of coating layer. The blistering limit for the typical finish coating by the infrared heating was estimated as the heating rate slower than $20^{\circ}C/sec$ regardless of colors of PCM resins.

  • PDF

성능검증을 위한 마이크로파일 현장 시험시공 및 재하시험 (Verification Studies for Field Peformance of Micropiling)

  • 구정민;이기환;조영준;최창호
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.368-375
    • /
    • 2009
  • This paper describes field installation and load test results performed for three types of micropiles in the process of developing a new micropiling method. Field tests were performed for two conventional types(i.e., micropile reinforced with steel bar and gravity grouting, micropile reinforced with steel bar and steel casing and gravity grouting) and a proposed type(i.e., micropile reinforced with hollow steel pipe wrapped with geotextile-pack and pressurized grouting). The load test results subjected to axial compression and tension and lateral loading conditions are described in this paper. The micropiles were exposed in the air in order to verify the installation quality and curing condition of grouting material via ground excavation. Axial compression and tension test results indicate that the new micropile type provide at least 40% higher bearing capacity than that of conventional types. Based on the examination of exposed piles, it is induced that the proposed method, packed micropile, provides better interlocking between grouts and surrounding soils and increases higher frictional resistance comparing to conventional types.

  • PDF

국내 의료기기관리제도의 현황분석에 따른 정책적 제도개선 방안에 관한 연구 (A study on the system improvement policy according to the status analysis of medical device control system in Korea)

  • 이경만;백낙기;서종현
    • 대한안전경영과학회지
    • /
    • 제12권3호
    • /
    • pp.37-52
    • /
    • 2010
  • This study is aimed at proposing the national policy for medical device control system in Korea as deeply analysed the present status of the system. On 1979, Korean government had started to inspect 24 kinds of the medical devices such as X-ray diagnostic equipments, medical sterilizer and etc. mostly imported from advanced countries which USA, Germany and Japan for the first time according to the Pharmaceutical Affairs Law. However medical devices were becoming consideration as an important partner of diagnosis, curing and alleviation of diseases by medical doctors and also much important keeping the health at home. Furthermore medical devices industry can be designated as a national growth engine industry. So it is necessary not only to harmonize to international standards but also the harmonization of the system including pre-market application and post-market surveillance, is strongly needed by the Korea Food and Drugs Administration(KFDA).

혼합 하중하에서의 고분자/거친금속 계면의 파손경로 (Failure Paths of Polymer/Roughened Metal Interfaces under Mixed-Mode Loading)

  • 이호영;김성룡
    • 한국재료학회지
    • /
    • 제14권5호
    • /
    • pp.322-327
    • /
    • 2004
  • Copper-based leadframe sheets were oxidized in two kinds of hot alkaline solutions to form brown-oxide or black-oxide layer on the surface. The oxide coated leadframe sheets were molded with epoxy molding compound (EMC). After post mold curing, the oxide-coated EMC-leadframe joints were machined to form sandwiched Brazil-nut (SBN) specimens. The SBN specimens were used to measure the fracture toughness of the EMC/leadframe interfaces under mixed-mode (mode I + mode II) loading conditions. Fracture surfaces were analyzed by various equipment to investigate failure path. The results revealed that the failure paths were strongly dependent on the oxide type. In case of brown oxide, hackle-type failure was observed and failure path lay near the EMC/CuO interface with a little inclining to CuO at all case. On the other hand, in case of black oxide, quite different failure path was observed with respect to the distance from the tip of pre-crack and phase angle. Different failures occurred with oxide type is presumed to be due to the difference in microstructure of the oxides.

조선해양 파이프 단열재 커버 적용을 위한 내화/난연 성능을 갖는 친환경 바잘트섬유 강화 퓨란계 복합재료 개발 연구 (Development of Eco-friendly Basalt Fiber-reinforced Furan-based Composite Material with Improved Fire and Flame Retardants for Shipbuilding and Offshore Pipe Insulation Cover)

  • 권동준;서형석
    • Composites Research
    • /
    • 제34권1호
    • /
    • pp.57-62
    • /
    • 2021
  • 조선해양산업에서 친환경 선박 및 경량화 기자재에 관한 관심이 높아짐에 따라 파이프 등의 기자재에 복합재료를 적용하고 있다. 본 연구에서는 친환경 및 내열/난연 성능을 요구하는 파이프 단열재 커버에 적용하기 위해 친환경 소재인 바잘트 섬유강화 퓨란복합재료(BFC, basalt fiber reinforced furan composite)를 제조하였다. BFC 소재의 낮은 물성을 강화시키기 위해 후경화 조건의 최적화 연구를 수행하였고, BFC 소재의 기계적강도, 내열/난연 특성 강화, 친화경 특성에 대한 실험과 평가를 진행하였다. 최종적으로 연구 결과 조선해양기자재인 파이프 단열재 커버에 BFC 소재의 적용이 가능함을 확인하였다.

복합레진의 광중합 전·후와 shade guide의 색차 비교 (COLOR DIFFERENCES BETWEEN RESIN COMPOSITES BEFORE- AND AFTER-POLYMERIZATION, AND SHADE GUIDES)

  • 전이주;조성식;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제24권2호
    • /
    • pp.299-309
    • /
    • 1999
  • The composite resin, due to its esthetic qualities, is considered the material of choice for restoration of anterior teeth. With respect to shade control, the direct-placement resin composites offer some distinct advantages over indirect restorative procedures. Visible-light-cured (VLC) composites allow dentists to match existing tooth shades or to create new shades and to evaluate them immediately at the time of restoration placement. Optimal intraoral color control can be achieved if optical changes occurring during application are minimized. An ideal VLC composite, then, would be one which is optically stable throughout the polymerization process. The shade guides of the resin composites are generally made of plastic, rather than the actual composite material, and do not accurately depict the true shade, translucency, or opacity of the resin composite after polymerization. So the numerous problems associated with these shade guides lead to varied and sometimes unpredictable results. The aim of this study was to assess the color changes of current resin composite restorative materials which occur as a result of the polymerization process and to compare the color differences between the shade guides provided with the products and the actual resin composites before- and after-polymerization. The results obtained from this investigation should provide the clinician with information which may aid in improved color match of esthetic restoration. Five light activated, resin-based materials (${\AE}$litefil, Amelogen Universal, Spectrum TPH VeridonFil-Photo, and Z100) and shade guides were used in this study. Three specimens of each material and shade combination were made. Each material was condensed inside a 1.5mm thick metal mold with 10mm diameter and pressed between glass plates. Each material was measured immediately before polymerization, and polymerized with Curing Light XL 3000 (3M Dental products, USA) visible light-activation unit for 60 seconds at each side. The specimens were then polished sequentially on wet sandpaper. Shade guides were ground with polishing stones and rubber points (Shofu) to a thickness of approximately 1.5mm. Color characteristics were performed with a spectrophotometer (CM-3500d, Minolta Co., LTD). A computer-controlled spectrophotometer was used to determine CIELAB coordinates ($L^*$, $a^*$ and $b^*$) of each specimen and shade guide. The CIELAB measurements made it possible to evaluate the amount of the color difference values (${\Delta}E{^*}ab$) of resin composites before the polymerization process and shade guides using the post-polishing color of the composite as a control, CIE standard D65 was used as the light source. The results were as follows. 1. Each of the resin composites evaluated showed significant color changes during light-curing process. All the resin composites evaluated except all the tested shades of 2100 showed unacceptable level of color changes (${\Delta}E{^*}ab$ greater than 3.3) between pre-polymerization and post-polishing state. 2. Color differences between most of the resin composites tested and their corresponding shade guides were acceptable but those between C2 shade of ${\AE}$litefil and IE shade of Amelogen Universal and their respective shade guides exceeded what is acceptable. 3. Comparison of the mean ${\Delta}E{^*}ab$ values of materials revealed that Z100 showed the least overall color change between pre-polymerization and post-polishing state followed by ${\AE}$litefil, VeridonFil-Photo, Spectrum TPH, and Amelogen Universal in the order of increasing change and Amelogen Universal. Spectrum TPH, 2100, VeridonFil-Photo and ${\AE}$litefil for the color differences between actual resin and shade guide. 4. In the clinical environment, the shade guide is the better choice than the shade of the actual resin before polymerization when matching colors. But, it is recommended that custom shade guides be made from resin material itself for better color matching.

  • PDF

수용성 페놀-포름알데히드 수지의 열안정성 및 경화거동 (Thermal Stability and Cure Behavior of Waterborne Phenol-Formaldehyde Resin)

  • 윤성봉;김진우;조동환
    • 접착 및 계면
    • /
    • 제7권1호
    • /
    • pp.16-22
    • /
    • 2006
  • 본 연구에서는 페놀수지 SMC 제조에 사용되는 수용성 레졸형 페놀-포름알데히드 수지의 열안정성과 경화 발열반응 피크의 변화에 미치는 경화온도 및 경화시간의 영향을 열중량분석기와 시차주사열량계를 사용하여 조사하였다. 수용성 페놀-포름알데히드 수지의 중량감소는 주로 $200^{\circ}C,\;400^{\circ}C$ 그리고 $500^{\circ}C$ 부근에서 세 단계로 발생하였다. 경화된 수지의 $750^{\circ}C$에서 탄화수율은 약 62%~65%이었다. 수용성 페놀수지의 열안정성은 경화온도와 경화시간이 증가할수록 증가하였다. 경화시 발열반응은 약 $120^{\circ}C{\sim}190^{\circ}C$ 사이에서 진행되며, 발열피크의 최대점은 약 $165^{\circ}C{\sim}170^{\circ}C$ 사이에서 관찰되었다. 발열반응 곡선의 형태와 발열피크의 최대점은 주어진 경화온도와 경화시간에 의존하였다. 경화되지 않은 수지에 포함되어 있는 $H_2O$ 및 휘발성분을 제거하기 위하여 경화 또는 성형 전에 적어도 $100^{\circ}C$ 이상에서 약 60분 이상의 열처리가 요구되었다. $130^{\circ}C$에서 120분 동안의 경화는 수용성 페놀-포름알데히드 수지의 발열피크를 사라지게 하며, $180^{\circ}C$에서 60분 동안이 후경화는 수지의 열안정성을 더욱 향상시켜 주었다.

  • PDF

친환경고화재와 탄소섬유 보강토의 일축압축강도 특성 (Unconfined Compressive Strength Characteristics of Eco-Friendly Stabilizers and Carbon Fiber Reinforced Soil)

  • 오세욱;양승환;김홍석
    • 한국지반환경공학회 논문집
    • /
    • 제25권8호
    • /
    • pp.13-19
    • /
    • 2024
  • 본 연구에서는 풍화토 비탈면에서 발생하는 세굴 및 표층 붕괴 면의 표층 보강을 목적으로 탄소섬유와 친환경고화재(E.S.B.)를 혼합하여 일축 압축강도 시험을 수행하였다. E.S.B.와 탄소섬유의 최적 배합비를 결정하기 위해 E.S.B.는 10%, 20%, 30%의 조건을 설정하였고, 탄소섬유는 0.3%, 0.6%, 0.9%, 1.2%로 설정하였다. 또한, 건조밀도 및 재령 기간에 따른 일축 압축강도 변화를 분석하기 위해 최대건조단위 중량의 85%, 95%를 적용하고 재령 기간 3일, 7일, 28일로 설정하였다. 비탈면 표층 보강을 위한 기준 강도는 ACI 230.1R-09(2009)에서 7일 기준 4MPa, 28일 기준 6MPa로 제안하고 있다. 압축시험 결과 E.S.B. 보강토의 일축 압축강도는 다짐도 95%인 경우 E.S.B. 혼합비율 10% 이상에서 기준 강도를 충족하는 것을 알 수 있다. 또한, 친환경고화재(E.S.B.) 보강토에 탄소섬유를 혼합한 결과 일축 압축강도에 의한 항복점 이후 탄소섬유를 혼합한 조건에서 연성 형태의 파괴 형상이 나타나 항복 이후 발생하는 전도에 대하여 보완할 수 있으며, 탄소섬유 0.6% 혼합비율에서 최대강도를 발현하는 것으로 분석되었다. 탄소섬유 보강토는 탄소섬유를 혼합하지 않은 조건과 비교하여 일축 압축강도가 약 54~70%의 강도증가율이 나타났다.

고농도 과산화수소와 플라즈마 아크를 이용한 미백 치료에 있어서 불소의 효과 (Effect of Fluoride Treatment after Bleaching with Hydrogen Peroxide exposed to Plasma Arc)

  • 정선영;이영은;안상헌;양해영;전은숙;최연희;송근배
    • 치위생과학회지
    • /
    • 제11권4호
    • /
    • pp.375-380
    • /
    • 2011
  • This study evaluated whether fluoride treatment can affect recovery of the irregularity of enamel surface after tooth whitening with a high concentration of hydrogen peroxide (HP) activated by plasma arc light. A total of 36 bovine teeth stained with coke were used in this experiment. The specimens were classified into following three groups (two different commercial plasma arc groups and a control group without light curing source): (1) 35% HP gel only, (2): 35% HP gel and Plasma arc A, and (3) 35% HP gel and Plasma arc B. To measure color changes and surface morphologies before and after the bleaching, colorimeter and scanning electron microscopy were used, respectively. When the specimens were bleached with hydrogen peroxide and plasma arc lights, the bleaching effect was greater than when only hydrogen peroxide gels were used (Kruskal-Wallis test, p<0.05). In addition, plasma arc B showed the more color changes than plasma arc A (Bonferroni post-hoc test, p<0.05). The surfaces of the teeth treated with fluoride gel after the whitening treatment came to be smooth. Therefore, the results of this study suggested that the fluoride application for patients who got tooth whitening therapy with a high concentration of hydrogen peroxide gels activated by plasma arc light will be effective to recover rough enamel surfaces.