• Title/Summary/Keyword: post

Search Result 25,253, Processing Time 0.051 seconds

Effect of the Configuration of Contact Type Textile Electrode on the Performance of Heart Activity Signal Acquisition for Smart Healthcare (스마트 헬스케어를 위한 심장활동 신호 검출용 접촉식 직물전극의 구조가 센싱 성능에 미치는 영향)

  • Cho, Hyun-Seung;Koo, Hye-Ran;Yang, Jin-Hee;Lee, Kang-Hwi;Kim, Sang-Min;Lee, Jeong-Hwan;Kwak, Hwy-Kuen;Ko, Yun-Su;Oh, Yun-Jung;Park, Su-Youn;Kim, Sin-Hye;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.4
    • /
    • pp.63-76
    • /
    • 2018
  • The purpose of this study was to investigate the effect of contact type textile electrode structure on heart activity signal acquisition for smart healthcare. In this study, we devised six contact type textile electrodes whose electrode size and configuration were manipulated for measuring heart activity signals using computerized embroidery. We detected heart activity signals using a modified lead II and by attaching each textile electrode to the chest band in four healthy male subjects in a standing static posture. We measured the signals four times repeatedly for all types of electrodes. The heart activity signals were sampled at 1 kHz using a BIOPAC ECG100, and the detected original signals were filtered through a band-pass filter. To compare the performance of heart activity signal acquisition among the different structures of the textile electrodes, we conducted a qualitative analysis using signal waveform and size as parameters. In addition, we performed a quantitative analysis by calculating signal power ratio (SPR) of the heart activity signals obtained through each electrode. We analyzed differences in the performance of heart activity signal acquisition of the six electrodes by performing difference and post-hoc tests using nonparametric statistic methods on the calculated SPR. The results showed a significant difference both in terms of qualitative and quantitative aspects of heart activity signals among the tested contact type textile electrodes. Regarding the configurations of the contact type textile electrodes, the three-dimensionally inflated electrode (3DIE) was found to obtain better quality signals than the flat electrode. However, regarding the electrode size, no significant difference was found in performance of heart signal acquisition for the three electrode sizes. These results suggest that the configuration method (flat/3DIE), which is one of the two requirements of a contact type textile electrode structure for heart activity signal acquisition, has a critical effect on the performance of heart activity signal acquisition for wearable healthcare. Based on the results of this study, we plan to develop a smart clothing technology that can monitor high-quality heart activity without time and space constraints by implementing a clothing platform integrated with the textile electrode and developing a performance improvement plan.

Fabrication of Strain Sensor Based on Graphene/Polyurethane Nanoweb and Respiration Measurement (그래핀/폴리우레탄 나노웹 기반의 스트레인센서 제작 및 호흡측정)

  • Lee, Hyocheol;Cho, Hyeon-seon;Lee, Eugene;Jang, Eunji;Cho, Gilsoo
    • Science of Emotion and Sensibility
    • /
    • v.22 no.1
    • /
    • pp.15-22
    • /
    • 2019
  • The purpose of this study is to develop a strain sensor based on a nanoweb by applying electrical conductivity to a polyurethane nanoweb through the use of Graphene. For this purpose, 1% Graphene ink was pour-coated on a polyurethane nanoweb and post-treated with PDMS (Polydimethylsiloxane) to complete a wearable strain sensor. The surface characteristics of the specimens were evaluated using a field emission scanning electron microscope (FE-SEM) to check whether the conductive material was well coated on the surface of the specimen. Electrical properties of the specimens were measured by using a multimeter to measure the linear resistance of the specimen and comparing how the line resistance changes when 5% and 10% of the specimens are tensioned, respectively. In order to evaluate the performance of the specimen, the gauge factor was obtained. The evaluation of the clothing was performed by attaching the completed strain sensor to the dummy and measuring the respiration signal according to the tension using MP150 (Biopac system Inc., USA) and Acqknowledge (ver. 4.2, Biopac system Inc., U.S.A.). As a result of the evaluation of the surface characteristics, it was confirmed that all the conductive nanoweb specimen were uniformly coated with the Graphen ink. As a result of measuring the resistance value according to the tensile strength, the specimen G, which was treated with just graphene had the lowest resistance value, the specimen G-H had the highest resistance value, and the change of the line resistance value of the specimen G and the specimen G-H is increased to 5% It is found that it increases steadily. Unlike the resistance value results, specimen G showed a higher gauge rate than specimen G-H. As a result of evaluation of the actual clothes, the strain sensor made using the specimen G-H measured the stable peak value and obtained a signal of good quality. Therefore, we confirmed that the polyurethane nanoweb treated with Graphene ink plays a role as a breathing sensor.

Effects of a Short-term Multimodal Group Intervention Program on Cognitive Function and Depression of the Elderly (단기 집단 복합중재가 정상 노인의 인지기능 및 우울에 미치는 영향)

  • Jung, Beom-Jin;Choi, Yu-Jin
    • Therapeutic Science for Rehabilitation
    • /
    • v.8 no.3
    • /
    • pp.57-68
    • /
    • 2019
  • Purpose: This study aimed to investigate the effects of a short-term group multimodal intervention program that mixes physical activity, cognitive motion, and social interaction, on the cognitive function and depression level of healthy over 75-year-old individuals. Method: This study used a one group pre-test-post-test design, and intervention was made for 70 minutes per session, once a week, for four sessions in total. To compare changes in cognitive function, depression level and physical function before and after intervention, this study used the Mini-Mental State Examination-Dementia Screening (MMSE-DS), Geriatric Depression Scale-Short Form (GDS-SF), and Berg Balance Scale (BBS). Result: After applying group multimodal interventions to healthy over 75-year-old individuals, there was a statistically significant improvement in their cognitive function (p < 0.01), and there was a statistically significant decrease in their depression level (p < 0.05). Also, there was an increase in the rating score of the degree of balance from $46.83{\pm}9.11$ points before the intervention, to $48.08{\pm}7.00$ points after the intervention; however, it was not statistically significant (p > 0.05). Conclusion: Short-term group multimodal intervention that mixes physical activity, cognitive motion, and social interaction had a significant effect on slowing down the deterioration of cognitive function in healthy over 75 year-old individuals, and decreased their depression level. This study is significant in that it presents a foundation for providing more systematic intervention for the prevention of dementia and depression in the healthy older individuals. Follow-up studies should verify the result through research on the effects of an occupational therapist's professional treatment, and experimental group-control research.

A Study on the Quality Improvement of Brain Perfusion SPECT Image (뇌혈류 단일광자방출단층촬영 영상 품질 향상에 대한 연구)

  • Kil, Sang-Hyeong;Lim, Yung-Hyun;Park, Gwang-Yeol;Cho, Seong-Mook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.13-19
    • /
    • 2019
  • Purpose Tc-99m HMPAO is widely used radiopharmaceutical for brain perfusion SPECT. Tc-99m HMPAO is chemically unstable and is liable to show deterioration of labeling efficiency due to high incidence of secondary Tc-99m HMPAO complex, free pertechnetate and reduced-hydrolyzed Tc-99m. In this study, we investigated whether sialogogues administration could reduce the impurities of Tc-99m HMPAO. Materials and Methods In thirty subjects(20 male and 10 female, age range 19~89 years, mean age $60.7{\pm}14.5years$), brain perfusion SPECT were performed at basal and citric acid stimulation states consecutively after injection of 555 MBq of Tc-99m HMPAO. In the salivary glands, the uptake coefficient was calculated using Siemens processing program. Statistical comparison between before and after the citric acid stimulation performed paired t-test. P value less than 0.05 was regarded as statistically significant. Results Salivary glands uptake was $12900{\pm}3101$ counts in basal and $10677{\pm}2742$ counts in citric acid stimulation states. Unnecessary impurities in the body is much decreased after citric acid administration(t=10.78, P<0.05). The image quality was much improved after administration of citric acid and the regional cerebral perfusion was clearly from demarcated the background. Conclusion The impurity is distributed throughout the body particularly in the salivary glands and nasal mucosa when Tc-99m HMPAO brain perfusion SPECT is performed. If this impurities is not removed, the quality of the image may deteriorate, resulting in errors in visual evaluation. The use of sialogogues could be helpful for decreasing unnecessary impurities in the body.

Effects of Balance Taping Therapy on Improving Knee Pain and the Obstacle in Daily Activity in Rural Elderly Women (밸런스 테이핑요법이 농촌 여성노인의 무릎통증과 일상활동장애 개선에 미치는 영향)

  • Kim, Ae-Jung;Park, Hae-Sook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.7
    • /
    • pp.218-227
    • /
    • 2019
  • This study examined the effects of balance taping therapy on improving knee pain and the obstacles to daily activity in rural elderly women. The research design was a quasi-experimental research using a non-equivalent control group pre-test and post-test design. The data were collected from January 19th to April 14th, 2017. The research subjects included female elderly over 65 years old who visited 12 senior centers located at Y city in rural areas. The participants were composed of 26 people in the experimental group and 28 people in the control group. Data were collected before and 24 hours after balance taping therapy, and the pain and obstacles to daily activity were measured. The collected data were analyzed using the PASW Statistics 23 Program, which included a $X^2-test$, Shapiro-Wilk test, and Mann-Whitney U test. After the intervention, significant differences were observed in the knee pain (Z=-6.658, p<.001) and obstacles to daily activity (Z=-3.466, p=.001). With regard to lower domain variables of the obstacles to daily activity, significant differences in standing up (Z=-2.860, p=.004), daily activity (Z=-2.629, p=.009), walking (Z=-3.868, p<.001), and dressing up (Z=-2.049, p=.040) were observed between the two groups. On the other hand, there were no significant differences in grip (Z=-.542, p=.588) and arm stretching (Z=-.416, p=.678). In conclusion, applying balance taping to rural elderly women clearly decreases the level of knee pain, reduces the obstacles to daily activity, and improves their quality of life.

Verification the Systems Thinking Factor Structure and Comparison of Systems Thinking Based on Preferred Subjects about Elementary School Students' (초등학생의 시스템 사고 요인 구조 검증과 선호 과목에 따른 시스템 사고 비교)

  • Lee, Hyonyong;Jeon, Jaedon;Lee, Hyundong
    • Journal of The Korean Association For Science Education
    • /
    • v.39 no.2
    • /
    • pp.161-171
    • /
    • 2019
  • The purposes of this study are: 1) to verify the systems thinking factor structure of elementary school students and 2) to compare systems thinking according to their preferred subjects in order to get implications for following research. For the study, pre-tests analyze data from 732 elementary school students using the STMI (Systems Thinking Measuring Instrument) developed by Lee et al. (2013). And exploratory factor analysis was conducted to identify the factor structure of the students. Based on the results of the pre-test, the expert group council revised the STMI so that elementary school students could respond to the 5-factor structure that STMI intended. In the post-test, 503 data were analyzed by modified STMI and exploratory factor analysis was performed. The results of the study are as follows: First, in the pre-test, elementary school students responded to the STMI with a test paper consisting of two factors (personal internal factors and personal external factors). The total reliability of the instrument was .932 and the reliability of each factor was analyzed as .857 and .894. Second, for modified STMI, elementary school students responded a 4-factor instrument. Team learning, Shared Vision, and Personal Mastery were derived independent factors, and mental model and systems analysis were derived 1-factor. The total reliability of the instrument was .886 and the reliability of each factor was analyzed as .686 to .864. Finally, a comparison of systems thinking according to preferred subjects showed a significant difference between students who selected science (engineering) group and art (music and physical education). In conclusion, it was confirmed that statistically meaningful results could be obtained using STMI modified by term and sentence structure appropriate for elementary school students, and it is a necessary to study the relation of systems thinking with various student variables such as the preferred subjects.

Relationship between porcine miR-20a and its putative target low-density lipoprotein receptor based on dual luciferase reporter gene assays

  • Ding, Yueyun;Zhu, Shujiao;Wu, Chaodong;Qian, Li;Li, DengTao;Wang, Li;Wan, Yuanlang;Zhang, Wei;Yang, Min;Ding, Jian;Wu, Xudong;Zhang, Xiaodong;Gao, Yafei;Yin, Zongjun
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.32 no.7
    • /
    • pp.922-929
    • /
    • 2019
  • Objective: Mutations in low-density lipoprotein receptor (LDLR), which encodes a critical protein for cholesterol homeostasis and lipid metabolism in mammals, are involved in cardiometabolic diseases, such as familial hypercholesterolemia in pigs. Whereas microRNAs (miRNAs) can control LDLR regulation, their involvement in circulating cholesterol and lipid levels with respect to cardiometabolic diseases in pigs is unclear. We aimed to identify and analyze LDLR as a potential target gene of SSC-miR-20a. Methods: Bioinformatic analysis predicted that porcine LDLR is a target of SSC-miR-20a. Wild-type and mutant LDLR 3'-untranslated region (UTR) fragments were generated by polymerase chain reaction (PCR) and cloned into the pGL3-Control vector to construct pGL3 Control LDLR wild-3'-UTR and pGL3 Control LDLR mutant-3'-UTR recombinant plasmids, respectively. An miR-20a expression plasmid was constructed by inserting the porcine premiR-20a-coding sequence between the HindIII and BamHI sites in pMR-mCherry, and constructs were confirmed by sequencing. HEK293T cells were co-transfected with the miR-20a expression or pMR-mCherry control plasmids and constructs harboring the corresponding 3'-UTR, and relative luciferase activity was determined. The relative expression levels of miR-20a and LDLR mRNA and their correlation in terms of expression levels in porcine liver tissue were analyzed using reverse-transcription quantitative PCR. Results: Gel electrophoresis and sequencing showed that target gene fragments were successfully cloned, and the three recombinant vectors were successfully constructed. Compared to pMR-mCherry, the miR-20a expression vector significantly inhibited wild-type LDLR3'-UTR-driven (p<0.01), but not mutant LDLR-3'-UTR-driven (p>0.05), luciferase reporter activity. Further, miR-20a and LDLR were expressed at relatively high levels in porcine liver tissues. Pearson correlation analysis revealed that porcine liver miR-20a and LDLR levels were significantly negatively correlated (r = -0.656, p<0.05). Conclusion: LDLR is a potential target of miR-20a, which might directly bind the LDLR 3'-UTR to post-transcriptionally inhibit expression. These results have implications in understanding the pathogenesis and progression of porcine cardiovascular diseases.

Effects of primers on the microtensile bond strength of resin cements to cobalt-chromium alloy (레진 시멘트와 코발트 크롬 합금의 미세인장결합강도에 다양한 프라이머들이 미치는 영향)

  • Jung, Hong-Taek;Campana, Shiela A.;Park, Jin-Hong;Shin, Joo-Hee;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.95-101
    • /
    • 2019
  • Purpose: The aim of this study is to evaluate the effects of various primers on the microtensile bond strength (${\mu}TBS$) of resin cements to cobalt-chromium (Co-Cr) dental casting alloy. Materials and methods: Four adhesive primers (Universal primer, Metal primer II, Alloy primer, and Metal/Zirconia primer) and two resin cements (Panavia F2.0, G-CEM LinkAce) were tested. One hundred fifty Co-Cr beams were prepared from Co-Cr ingots via casting ($6mm\;ength{\times}1mm\;width{\times}1mm\;thick$). The metal beams were randomly divided into ten groups according to the adhesive primers and resin cements used; the no-primer groups served as the control (n = 15). After sandblasting with aluminum oxide ($125{\mu}m$ grain), the metal and resin cements were bonded together using a silicone mold. Prior to testing, all metal-resin beams were examined under stereomicroscope, and subjected to the ${\mu}TBS$ test. The mean value of each group was analyzed via one-way ANOVA with Tukey's test as post hoc (${\alpha}=.05$) using SPSS software. Results: The mean ${\mu}TBS$ of all groups was ranged from 20 to 28 MPa. There is no statistically significant difference between groups (P > .05). Mixed failure, which is the combination of adhesive and cohesive failures, is the most prevalent failure mode in both the Panavia F2.0 and G-Cem LinkAce groups. Conclusion: The ${\mu}TBS$ of all tested groups are relatively high; however, the primers used in this study result in no favorable effect in the ${\mu}TBS$ of Panavia F2.0 and G-Cem LinkAce resin cement to Co-Cr alloy.

Comparison of Post-Harvest Character and Storability at Several Temperature for Lactuca indica L. Baby and Adult Leaves (왕고들빼기 어린잎과 성체의 수확 후 특성과 온도별 저장성 비교)

  • Kim, Ju Young;Han, Su Jeong;Wang, Lixia;Choi, In-Lee;Kang, Ho-Min
    • Journal of Bio-Environment Control
    • /
    • v.28 no.2
    • /
    • pp.172-177
    • /
    • 2019
  • Lactuca indica L. ('Seonhyang') baby leaves were harvested after cultivation for 4 weeks (less than 10 cm plant height) and adults were cultivated for 8 weeks ($20{\pm}5cm$ plant height). The respiration rate and the ethylene production rate of Lactuca indica leaves were higher than those of the baby leaves but the DPPH radical scavenging ability was lower than baby leaves. The $L^*$, $a^*$ and $b^*$ values did not show any significant difference between baby leaves and adult leaves but the chlorophyll content was higher in adult leaves. All adult and baby leaves of Lactuca indica were stored at $2^{\circ}C$, $8^{\circ}C$, and $20^{\circ}C$, respectively. The higher the storage temperature, the higher the fresh weight loss rate and weight loss rate of adult leaves was lower at $2^{\circ}C$ and $8^{\circ}C$. The visual quality of Lactuca indica leaves were determined by the panel test during storage and it deteriorated faster as the storage temperature increased. The shelf life that calculated the period of maintaining higher than 3 points of visual quality was longer than 1.6 days at $2^{\circ}C$, 1.4 days at $8^{\circ}C$ and 1.5 days at $20^{\circ}C$. The oxygen and carbon dioxide concentrations within the package of Lactuca indica leaves were similar to those in atmosphere. The chlorophyll content was maintained higher at lower storage temperature in the last storage day and the off-odor was higher in baby leaves than in the adult leaves of Lactuca indica L.

Comparison of the accuracy of intraoral scanner by three-dimensional analysis in single and 3-unit bridge abutment model: In vitro study (단일 수복물과 3본 고정성 수복물 지대치 모델에서 삼차원 분석을 통한 구강 스캐너의 정확도 비교)

  • Huang, Mei-Yang;Son, Keunbada;Lee, Wan-Sun;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.102-109
    • /
    • 2019
  • Purpose: The purpose of this study was to evaluate the accuracy of three types of intraoral scanners and the accuracy of the single abutment and bridge abutment model. Materials and methods: In this study, a single abutment, and a bridge abutment with missing first molar was fabricated and set as the reference model. The reference model was scanned with an industrial three-dimensional scanner and set as reference scan data. The reference model was scanned five times using the three intraoral scanners (CS3600, CS3500, and EZIS PO). This was set as the evaluation scan data. In the three-dimensional analysis (Geomagic control X), the divided abutment region was selected and analyzed to verify the scan accuracy of the abutment. Statistical analysis was performed using SPSS software (${\alpha}=.05$). The accuracy of intraoral scanners was compared using the Kruskal-Wallis test and post-test was performed using the Pairwise test. The accuracy difference between the single abutment model and the bridge abutment model was analyzed by the Mann-Whitney U test. Results: The accuracy according to the intraoral scanner was significantly different (P < .05). The trueness of the single abutment model and the bridge abutment model showed a statistically significant difference and showed better trueness in the single abutment (P < .05). There was no significant difference in the precision (P = .616). Conclusion: As a result of comparing the accuracy of single and bridge abutments, the error of abutment scan increased with increasing scan area, and the accuracy of bridge abutment model was clinically acceptable in three types of intraoral scanners.