  • An intracellular levansucrase gene, lscR from Rahnella aquatilis ATCC 15552, was cloned and its nucleotide sequence was determined. Nucleotide sequence analysis of this gene revealed a 1,238 bp open reading frame coding for a protein of 415 amino acids. The levansucrase was expressed by using a T7 promoter in Escherichia coli BL21 (DE3) and the enzyme activity was detected in the cytoplasmic fraction. The optimum pH and temperature of this enzyme for levan formation was pH 6 and $30^{\circ}C$, respectively. The deduced amino acid sequence of the lscR gene showed a high sequence similarity (59-89%) with Gram-negative levansucrses, while the level of similarity with Gram-positive enzymes was less than 42%. Multiple alignments of levansucrase sequences reported from Gram-negative and Gram-positive bacteria revealed seven conserved regions. A comparison of the catalytic properties and deduced amino acid sequence of lscR with those of other bacterial levansucrases strongly suggest that Gram-negative and Gram-positive levansucrases have an overall different structure, but they have a similar structure at the active site.

  • PDF

A Study on DVR Control for Unbalanced Voltage Compensation

  • Jung Hong-Ju;Suh In-Young;Kim Byung-Seob;Kim Rae-Young;Choi See-Young
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.803-807
    • /
    • 2001
  • This paper presents a new control scheme for a DVR (Dynamic Voltage Restorer) system consisting of series voltage source PWM converters. To control the negative sequence components of the source, it is necessary to detect the negative sequence components. Generally, a filtering process is used which has some undesirable effects. This paper suggests a new method for separating positive and negative sequences components. This control system is designed using differential controllers and digital filters. The positive and negative sequences are extracted and controlled individually. The performance of the presented controller and scheme are confirmed through simulation and actual experiment with a 2.5kVA prototype DVR system.

  • PDF

Analysis and Control of Cost-Effective Topologies for Single Phase to Three Phase Power Converter (비용절감형 단상-삼상 전력변환기 구조의 해석 및 제어)

  • Lee, Hae-Chun;Park, Tae-Yeol;Kim, Gi-Taek
    • Journal of Industrial Technology
    • /
    • v.19
    • /
    • pp.217-226
    • /
    • 1999
  • A single phase to three phase power converter with cost effective and simple structure is proposed. The converter consists of rectifier and inverter. The rectifier is composed of a half wave rectifier, a dc link capacitor, and a current limiting inductor, and the inverter is of only two switches with PWM control. For negative sequence operation the inverter output voltage leads the line input by $60^{\circ}$, and for positive sequence operation the inverter output voltage leads by $60^{\circ}$. We can see that positive sequence operation shows higher output voltage, slight harmonic distortion(2%), and better performances such as high efficiency and high power factor. A mathematical model for system analysis is provided, and specifications for selection and control scheme both for start-up and for steady state are analyzed. comparison and operational limits of positive and negative sequence operation are performed, and simulations and experiments are executed to verify the proposed.

  • PDF

A Directional Relay Algorithm Using Positive-Sequence Superimposed Quantity for Transmission Line Protection (정상 성분 변화량을 이용한 송전선로 보호용 방향 계전 알고리즘)

  • 이명수;유석구
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.4
    • /
    • pp.226-233
    • /
    • 2003
  • Directional elements are fundamental to protection scheme security and selectivity, performing such critical tasks as supervising distance elements and controlling overcurrent elements. But, conventional operating principles for directional detection based on negative or zero sequence quantify do not satisfy the requirements for improved sensitivity and fast operation under any fault conditions. In this paper, new algorithm for directional elements is proposed. The proposed algorithm use the positive-sequence superimposed voltages and currents in order to be used in all fault conditions. Also, because this algorithm uses a voltage compensation method. it can be well operated under strong source conditions.

Analysis of Sequence Impedances of 345kV Cable Transmission Systems (실계통 345kV 지중송전선 대칭좌표 임피던스의 해석)

  • Choi, Jong-Kee;Ahn, Yong-Ho;Yoon, Yong-Beum;Oh, Sei-Ill;Kwa, Yang-Ho;Lee, Myoung-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.905-912
    • /
    • 2013
  • Power system fault analysis is commonly based on well-known symmetrical component method, which describes power system elements by positive, negative and zero sequence impedance. In case of balanced fault, such as three phase short circuit, transmission line can be represented by positive sequence impedance only. The majority of fault in transmission lines, however, is unbalanced fault, such as line-to-ground faults, so that both positive and zero sequence impedance is required for fault analysis. When unbalanced fault occurs, zero sequence current flows through earth and skywires in overhead transmission systems and through cable sheaths and earth in cable transmission systems. Since zero sequence current distribution between cable sheath and earth is dependent on both sheath bondings and grounding configurations, care must be taken to calculate zero sequence impedance of underground cable transmission lines. In this paper, conventional and EMTP-based sequence impedance calculation methods were described and applied to 345kV cable transmission systems (4 circuit, OF 2000mm2). Calculation results showed that detailed circuit analysis is desirable to avoid possible errors of sequence impedance calculation resulted from various configuration of cable sheath bonding and grounding in underground cable transmission systems.

REPRESENTING NATURAL NUMBERS AS UNIQUE SUMS OF POSITIVE INTEGERS

  • Laohakosol, Vichian;Chalermchai, Jiraporn
    • The Pure and Applied Mathematics
    • /
    • v.11 no.1
    • /
    • pp.63-72
    • /
    • 2004
  • It is known that each natural number can be written uniquely as a sum of Fibonacci numbers with suitably increasing indices. In 1960, Daykin showed that the sequence of Fibonacci numbers is the only sequence with this property. Consider here the problem of representing each natural number uniquely as a sum of positive integers taken from certain sequence allowing a fixed number, $\cal{l}\geq2$, of repetitions. It is shown that the $(\cal{l}+1)$-adic expansion is the only such representation possible.

  • PDF

CONSISTENCY AND GENERAL TRUNCATED MOMENT PROBLEMS

  • Yoo, Seonguk
    • Journal of the Chungcheong Mathematical Society
    • /
    • v.31 no.4
    • /
    • pp.487-509
    • /
    • 2018
  • The Truncated Moment Problem (TMP) entails finding a positive Borel measure to represent all moments in a finite sequence as an integral; once the sequence admits one or more such measures, it is known that at least one of the measures must be finitely atomic with positive densities (equivalently, a linear combination of Dirac point masses with positive coefficients). On the contrary, there are more general moment problems for which we aim to find a "signed" measure to represent a sequence; that is, the measure may have some negative densities. This type of problem is referred to as the General Truncated Moment Problem (GTMP). The Jordan Decomposition Theorem states that any (signed) measure can be written as a difference of two positive measures, and hence, in the view of this theorem, we are able to apply results for TMP to study GTMP. In this note we observe differences between TMP and GTMP; for example, we cannot have an analogous to the Flat Extension Theorem for GTMP. We then present concrete solutions to lower-degree problems.

A COMPLETENESS ON GENERALIZED FIBONACCI SEQUENCES

  • Lee, Gwang-Yeon
    • Bulletin of the Korean Mathematical Society
    • /
    • v.32 no.2
    • /
    • pp.239-249
    • /
    • 1995
  • Let $V = (v_1, v_2, \cdots)$ be a sequence of positive integers arranged in nondecreasing order. We define V to be complete if every positive integer n is the sum of some subsequence of V, that is, $$ (1.1) n = \sum_{i=1}^{\infty} a_i v_i where a_i = 0 or 1.

  • PDF

A Study on the Sequence Impedance Modeling of Underground Transmission Systems (지중송전선로의 대칭분 임피던스 모델링에 관한 연구)

  • Hwang, Young-Rok;Kim, Kyung-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.6
    • /
    • pp.60-67
    • /
    • 2014
  • Power system fault analysis is commonly based on well-known symmetrical component method, which describes power system elements by positive, negative and zero sequence impedance. The majority of fault in transmission lines is unbalanced fault, such as line-to-ground faults, so that both positive and zero sequence impedance is required for fault analysis. When unbalanced fault occurs, zero sequence current flows through earth and ground wires in overhead transmission systems and through cable sheaths and earth in underground transmission systems. Since zero sequence current distribution between cable sheath and earth is dependent on both sheath bondings and grounding configurations, care must be taken to calculate zero sequence impedance of underground cable transmission lines. In this paper, EMTP-based sequence impedance calculation method was described and applied to 345kV cable transmission systems. Calculation results showed that detailed circuit analysis is desirable to avoid possible errors of sequence impedance calculation resulted from various configuration of cable sheath bonding and grounding in underground cable transmission systems.