• Title/Summary/Keyword: positive detector

Search Result 101, Processing Time 0.023 seconds

Is Lymph Node Size a Reliable Factor for Estimating Lymph Node Metastasis in Early Gastric Cancer?

  • Kim, Dong Jin;Kim, Wook
    • Journal of Gastric Cancer
    • /
    • v.18 no.1
    • /
    • pp.20-29
    • /
    • 2018
  • Purpose: Pre-operative lymph node (LN) size is a valuable parameter for determining treatment strategy for gastric cancer. However, a correlation between LN size and metastasis has not been established. Materials and Methods: Thirty-six LN-positive (LNP) and matched 36 LN-negative (LNN) patients were included, and pathology slides of the LNs of these patients were reviewed. All the LNs were measured along the long-axis (LA) and short-axis (SA), manually. Results: Average retrieved LNs were $37.3{\pm}19.8$ and $40.5{\pm}11.6$ in the LNN and LNP groups, respectively. In total 2,800 LNs, including 136 metastatic LNs (MLNs) and 2,664 non-metastatic LNs (nMLNs), were evaluated. Mean length was significantly more in MLNs along both, the LA and SA (MLN_LA vs. nMLN_LA: $4.97{\pm}3.84$ vs. $3.37{\pm}2.40mm$, MLN_SA vs. nMLN_SA: $3.86{\pm}3.19$ vs. $2.43{\pm}1.59mm$; P<0.001). However, 92.6% (126/136) and 95.6% (130/136) of MLNs were <10 mm along the LA and SA, respectively. In addition, only 22.2% of the LNP group exhibited an MLN as the largest LN. Conclusions: Pre-operative multi-detector computed tomography has limited ability in estimating the presence of metastasis in LNs because most MLNs are less than 10 mm, and only a small proportion of the LNP group exhibits an MLN as the largest MLN.

Percutaneous Sacroplasty : Effectiveness and Long-Term Outcome Predictors

  • Lee, Jaehyung;Lee, Eugene;Lee, Joon Woo;Kang, Yusuhn;Ahn, Joong Mo;Kang, Heung Sik
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.6
    • /
    • pp.747-756
    • /
    • 2020
  • Objective : To evaluate the effectiveness and long-term outcome predictors of percutaneous sacroplasty (PSP). Methods : This single-center study assessed 40 patients with sacral insufficiency fractures using the short-axis technique under C-arm flat-panel detector computed tomography (CT). Two radiologists reviewed the patients' magnetic resonance and CT images to obtain imaging findings before PSP and determine technical success, respectively. The short-term outcomes were visual analog scale score changes and opioid usage reductions. Long-term outcomes were determined using telephone interviews and the North American Spine Society (NASS) patient-satisfaction index at least one year after PSP. Results : Technical success was achieved without any significant complications in 39 patients (97.5%). Telephone interviews were possible with 12 patients and failed in 10 patients; death was confirmed in 18 patients. Fifteen patients (50%) re-visited the hospital and received conservative treatment, including spinal injections. Nine patients reported positive satisfaction (NASS patient-satisfaction index 1 or 2), while the negative satisfaction group (NASS patient-satisfaction index 3 or 4, n=3) showed a higher incidence of compression fractures at the thoracolumbar spine level (66.7% vs. 22.2%) and previous spinal injection history (66.7% vs. 33.3%). The poor response group also showed higher incidences of facet joint arthrosis (100% vs. 55.6%), central canal stenosis (100% vs. 22.2%), neural foraminal stenosis (33.3% vs. 22.2%), scoliosis (100% vs. 33.3%), and sagittal malalignment (100% vs. 44.4%). Conclusion : PSP was effective for sacral insufficiency fractures and showed good long-term outcomes. Combined compression fractures in the thoracolumbar spine and degenerative lumbar pathologies could be possible poor outcome predictors.

Aorto-Coronary Bypass Graft -A Case Report- (관상동맥 회로술 치험 1예)

  • 이두연
    • Journal of Chest Surgery
    • /
    • v.12 no.3
    • /
    • pp.297-305
    • /
    • 1979
  • Occlusive coronary artery disease presents a potential threat to a significant population in the United States. According to many case reports, the increasing incidence of coronary artery disease due to atherosclerosis is noted in Korean, recently. Operative vascular procedures have increased steadily in number over the past 20 years in the United States. There have been many isolated case reports about coronary artery surgery, but these had little clinical impact. Nowadays, major three coronary bypass surgery has developed principally at three cardiac centers in the United States since 1967. Among three coronary bypass operation, the aorta-coronary artery saphenous vein bypass graft was first demonstrated by Favolaro and Effler at the Cleveland Clinic in 1967. We experienced one case of coronary artery disease, which was treated successfully by aorta-coronary saphenous vein graft with mild hypothermia under extracorporeal circulation in May, 1977. Saphenous vein was removed from above the knee and was 2.5 mm in diameter. The left ventricle was not vented for the left ventricle was not overdistended. Temporary artificial pace-maker-Medtronic-was implanted for the prevention and treatment of post-operative arrhythmia and heart block in post-operative first day. He is a 57 year old male businessman who had been suffered from hypertension [200 mmHg in systolic pressure] since 4 years ago, who had intermittent conservative treatment at local clinic. He had been afflicted with severe chest pain with choking sensation for 50 days. This symptom was aggravated exposing cold weather, or cold water, but was respond to rest. Pre-operative ECG revealed no any other ischemic sign except sinus bradycardia. Significant S-T segment depression was noted at lead II, AVF after double 5 minutes exercise, indicating positive Master`s test. Serum cholesterol was slight elevated to 253 mg/dl. Final pre-operative diagnosis was made by coronary arteriogram, which showed about 1.0-cm segmental 90 % occlusive atherosclerotic lesion in the proximal part of right coronary artery above the origin of acute marginal artery. Left coronary artery revealed good patency and there was no collateral circulation between right and left coronary artery .Hospital course was not eventful. He was discharged with good result on the post-operative day. He has been free from chest pain for longer than 2 years. And also the arterial flow in the coronary bypass graft is auscultated with the pocket-sized ultrasonic velocity detector, which shows the patency of the coronary bypass graft good.

  • PDF

Monitoring of 7 mycotoxins in pork (돼지고기에서 7종 mycotoxins 잔류실태 조사)

  • Kim, Yoen-Joo;Kim, Mi-Ran;Choi, Tae-Suk;Kim, Young-Seob;Lee, Ju-Hyoung
    • Korean Journal of Veterinary Service
    • /
    • v.36 no.4
    • /
    • pp.303-309
    • /
    • 2013
  • This study was conducted to determine the content of 7 mycotoxins (aflatoxin $B_1$, $B_2$, $G_1$, $G_2$, $M_1$, ochratoxin A and zearalenone) using LC-MS/MS in pork available on the Korean markets. The analysis was carried out using following conditions; C18 column ($2.1{\times}100mm$, $1.7{\mu}m$), mobile phase composed of $H_2O$ (0.1 mM $NH_4Ac$ 0.01% HCOOH) : Methanol (0.1 mM $NH_4Ac$ 0.01% HCOOH), binary pump at a flow rate of 0.5 mL/min and $2{\mu}L$ of injection volume, MS/MS detector with ESI positive and negative mode. The quantication of mycotoxins was based on matrix-matched calibration curves with a correlation coefficient in excess of 0.99 for the 7 mycotoxins. The dectection limits were ranged 0.74~2.13 ng/g, with mean recoveries between 73.10~97.46% except aflatoxin $B_1$ (61.31%). We also monitored mycotoxin residues in 208 pork samples. The test results, mycotoxins were not found except one sample. Ochratoxin A in one sample of the test samples was detected below the quantification limit.

Distributions of Formaldehyde in Seoul in June, 2005 (2005년 6월의 서울시 대기의 포름알데히드 농도분포 특징)

  • Hwang Jung hoon;Lee Mee hye;Lee Gang woong;Han Jin seock
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.1
    • /
    • pp.63-71
    • /
    • 2006
  • An automated carbonyl measurement system was constructed. Atmospheric carbonyl compounds were extracted onto DNPH containing collection solution while flowing through a glass coil. Each carbonyl species was separated on a HPLC column and quantified by UV absorption detector. Using this system, carbonyl compounds were continuously measured at the campus of Korea University in Seoul, Korea during June, 2005. Sampling resolution was 30 minutes and the detection limit of HCHO was 0.19 ppbv. Also, $\O_{3}$, it's precursors, and meteorological parameters were measured. The maximum, minimum, average, and median concentrations of HCHO during the whole experiment was 35.8 ppbv, 1.4 ppbv, 11.7 ppbv, and 9.3 ppbv respectively. Formaldehyde showed a distinct diurnal variation with a broad maximum around 13 $\sim$ 15, which was 1 $\sim$ 3 hours ahead of an ozone maximum. During a couple of days, however, HCHO concentrations were kept high through the night or increased concomitantly with NOx in the morning. These results imply that HCHO was mainly produced from the photochemical oxidation of VOCs, but local emission sources couldn't be ruled out. The differences between daily maximum and minimum of $O_{3}$ and HCHO were calculated for 11 days of June, when typical diurnal variations were observed for the two species. A strong positive correlation was found between $\Delta O_{3}$ and $\Delta HCHO$ and the average mole ratio of $\Delta HCHO$ to $\Delta O_{3}$ was 2.6. It indicates that formaldehyde played a key role in $\Delta O_{3}$ production as an indicator species in Metropolitan Seoul during June, 2005.

Bioequivalence of Cephradine Capsules (Cephradine 250 mg) (세프라딘 캅셀(세프라딘 250 mg)의 생물학적 동등성)

  • 최준식;이진환;박영진;범진필
    • YAKHAK HOEJI
    • /
    • v.46 no.4
    • /
    • pp.290-294
    • /
    • 2002
  • Cephradine is an orally absorbed cephalosporin with a broad spectrum of activity against gram-positive and gram-negative bacteria and is highly resistant to beta-lactamase degradation. The purpose of the present study was to evaluate the bioequivalence of two cephradine capules, Cephradine capsule (Donggu Pharmaceutical Co., reference drug) and Cephradine capsule (Shinpoong Pharmaceutical Co., test drug), according to the guidelines of Korea Food and Drug Administration. Twenty-six normal volunteers, 24.6 $\pm$ 3.70 years in age and 62.4 $\pm$ 8.99 kg in body weight, were divided into two groups and a randomized 2 $\times$ 2 cross-over study was employed. After one capsule containing 250 mg of cephrdine was orally administered, blood was taken at predetermined time intervals and the concentrations of cephrdine in serum were determined using HPLC with UV detector. The pharmacokinetic parameters such as AU $C_{t}$ to $C_{max}$ and $T_{max}$ were calculated and ANOVA test was utilized for the statistical analysis of the parameters. The results showed that the differences in AUCt, $C_{max}$ and $T_{max}$ between two products were 2.89%, 1.05% and 1.06%, respectively, when calculated against the reference drug. The 90% confidence intervals were within log0.8 $\leq$ $\delta$ $\leq$ log1.25 (e.g., log0.9803 $\leq$ $\delta$ $\leq$ log1.0734 and log0.9674 $\leq$ $\delta$ $\leq$ log1.220 for AU $C_{t}$, and $C_{max}$, respectively). Two parameters met the criteria of KFDA for bioequivalence, indicating that Cephradine capsules (Shinpoong Pharmaceutical Co.) is bioequivalent to Cephradine capsules (Donggu Pharmaceutical Co.).o.).o.).).o.).

The Development of Extravasation Detection Accessory System for the Preventive Contrast Media Extravasation in the Computed Tomography: A Preliminary Report (CT 검사에서 조영제의 혈관외유출 예방을 위한 EDA 시스템 개발의 예비 보고)

  • Kweon Dae-Cheol;Jeong Seok-Hee;Kim Tae-Hyung;Kim Jeong-Goo;Park Peom
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.32-39
    • /
    • 2006
  • To assess the ability of an extravasation detection accessory (EDA) system to detect clinically important extravascular injection of iodinated contrast material delivered with an automated power injector. Fifty patients referred for contrast material enhanced body computed tomography studied in a prospective, observation study in which the EDA system was used to identify and interrupt any injection associated with clinically Important extravasation. The presence or absence of extravasation was definitively established with multi-detector CT at the injection site (injection rate, $2.0{\sim}2.5$ mL/sec). There were two true positive, extravasation volumes $22{\sim}25$ mL. The EDA system had sensitivity in the detection of clinically important extravasation. The EDA system is easy to use, safe, and accurate In the monitoring of intravenous injections for extravasation, which may prove especially useful in CT applications.

  • PDF

HPLC Analysis and Extraction Methods of Decursin and Decursinol Angelate in Angelica gigas Roots (당귀(Angelica gigas) 중 Decursin 및 Decursinol Angelate 추출 방법과 HPLC 분석)

  • Lee, Jang-Hoon;Chae, Hee-Jeong;Kim, Dong-Hyun;Lee, Sang-Hyun;Park, Sang-Yong;Kang, Young-Goo
    • Korean Journal of Pharmacognosy
    • /
    • v.34 no.3 s.134
    • /
    • pp.201-205
    • /
    • 2003
  • This paper is intended as an investigation of the analysis of high-performance liquid chromatography and the method of extraction of decursin and decursinol angelate in Angelica gigas roots. There are three kinds of extraction methods: distilled water, 50% EtOH and 100% EtOH. The condition of HPLC was obtained on a reversed-phase column $(Polarity\;dC_{18},\;4.6{\times}250 mm,\;5\;{\mu}m)$ using a phosphate buffer-acetonitrile-sodium lauryl sulfate as the mobile phase. Under these chromatographic conditions, UV detector was 230 nm, column temperature $30^{\circ}C$ and the speed of a current 1.0 ml/min, respectively. The results of extraction with distilled water, 50% EtOH and 100% EtOH in Angelica gigas roots were as follows. The concentrations of decursin and decursinol angelate were 182 and 153 ppm (distilled water), 3,142 and 2,547 ppm (50% EtOH) and 3,341 and 2,778 ppm (100% EtOH). There were high positive correlations between the concentrations of decursin and EtOH (r=0.8928, p<0.01) and decursinol angelate and EtOH (r=0.9009, p<0.01).

A Study on the Design and Implementation of Mathematics and Science Integrated Instruction (수학과학통합교육의 설계 및 실행에 대한 연구)

  • Lee, Hei-Sook;Rim, Hae-Mee;Moon, Jong-Eun
    • The Mathematical Education
    • /
    • v.49 no.2
    • /
    • pp.175-198
    • /
    • 2010
  • To understand natural or social phenomena, we need various information, knowledge, and thought skills. In this context, mathematics and sciences provide us with excellent tools for that purpose. This explains the reasons why there is always significant emphasis on mathematics and sciences in school education; some of the general goals in school education today are to illustrate physical phenomena with mathematical tools based on scientific consideration, to encourage students understand the mathematical concepts implied in the phenomena, and provide them with ability to apply what they learned to the real world problems. For the mentioned goals, we extract six fundamental principles for the integrated mathematics and science education (IMSE) from literature review and suggest a instructional design model. This model forms a fundamental of a case study we performed to which the IMSE was applied and tested to collect insights for design and practice. The case study was done for 10 students (2 female students, 8 male ones) at a coeducational high school in Seoul, the first semester 2009. Educational tools including graphic calculator(Voyage200) and motion detector (CBR) were utilized in the class. The analysis result for the class show that the students have successfully developed various mathematical concepts including the rate of change, the instantaneous rate of change, and derivatives based on the physical concepts like velocity, accelerate, etc. In the class, they described the physical phenomena with mathematical expressions and understood the motion of objects based on the idea of derivatives. From this result, we conclude that the IMSE builds integrated knowledge for the students in a positive way.

Development of IR Thermal Camera Detector based on Smartphone Interlocking for Hidden Camera Crime Prevention (몰래카메라 범죄방지를 위한 스마트폰 연동 기반의 IR 열카메라 탐지기 개발)

  • Kang, Young-Gil;Cho, Pil-Gu;Kim, Young-Gon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.6
    • /
    • pp.1-8
    • /
    • 2021
  • The performance of hidden camera cameras is improving day by day due to miniaturization and advanced technology integration according to the speed of technological development of smartphones. As this external networking computing environment is advanced and diversified, exposure to hidden cameras in addition to general safety cameras is also increasing. On the other hand, the technology for detecting and preventing hidden cameras is not keeping up with the development and speed of these hidden cameras. Therefore, in this study, the heat of the hidden camera was detected using infrared thermal detection technology based on general image and thermal image synthesis technology, and the reflectance of each wavelength according to the difference in ambient temperature was analyzed to reduce the false positive rate.