• Title/Summary/Keyword: positions

Search Result 6,436, Processing Time 0.035 seconds

A Cluster-Based Relay Station Deployment Scheme for Multi-Hop Relay Networks

  • Chang, Jau-Yang;Chen, Yun-Wei
    • Journal of Communications and Networks
    • /
    • v.17 no.1
    • /
    • pp.84-92
    • /
    • 2015
  • Multi-hop relay networks have been widely considered as a promising solution to extend the coverage area and to reduce the deployment cost by deploying the relay stations (RSs) in mobile communication systems. Suitable deployment for the RSs is one of the most important features of the demand nodes (DNs) to obtain a high data transmission rate in such systems. Considering a tradeoff among the network throughput, the deployment budget, and the overall coverage of the systems, efficient RS deployment schemes and corresponding algorithms must be developed and designed. A novel cluster-based RS deployment scheme is proposed in this paper to select the appropriate deployment locations for the relay stations from the candidate positions. To make an ideal cluster distribution, the distances between the DNs are calculated when deploying the RSs. We take into account the traffic demands and adopt a uniform cluster concept to reduce the data transmission distances of the DNs. On the basis of the different candidate positions, the proposed scheme makes an adaptive decision for selecting the deployment sites of the RSs. A better network throughput and coverage ratio can be obtained by balancing the network load among the clusters. Simulation results show that the proposed scheme outperforms the previously known schemes in terms of the network throughput and the coverage ratio. Additionally, a suitable deployment budget can be implemented in multi-hop relay networks.

A NUMERICAL METHOD TO ANALYZE GEOMETRIC FACTORS OF A SPACE PARTICLE DETECTOR RELATIVE TO OMNIDIRECTIONAL PROTON AND ELECTRON FLUXES

  • Pak, Sungmin;Shin, Yuchul;Woo, Ju;Seon, Jongho
    • Journal of The Korean Astronomical Society
    • /
    • v.51 no.4
    • /
    • pp.111-117
    • /
    • 2018
  • A numerical method is proposed to calculate the response of detectors measuring particle energies from incident isotropic fluxes of electrons and positive ions. The isotropic flux is generated by injecting particles moving radially inward on a hypothetical, spherical surface encompassing the detectors. A geometric projection of the field-of-view from the detectors onto the spherical surface allows for the identification of initial positions and momenta corresponding to the clear field-of-view of the detectors. The contamination of detector responses by particles penetrating through, or scattering off, the structure is also similarly identified by tracing the initial positions and momenta of the detected particles. The relative contribution from the contaminating particles is calculated using GEANT4 to obtain the geometric factor of the instrument as a function of the energy. This calculation clearly shows that the geometric factor is a strong function of incident particle energies. The current investigation provides a simple and decisive method to analyze the instrument geometric factor, which is a complicated function of contributions from the anticipated field-of-view particles, together with penetrating or scattered particles.

Analysis of Isometry of the Anterior Cruciate Ligament for Optimal Ligament Reconstruction (전방십자인대의 최적 재건을 위한 등장성 해석)

  • Park Jung-Hong;Suh Jeung-Tak;Moon Byung-Young;Son Kwon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.4 s.247
    • /
    • pp.457-464
    • /
    • 2006
  • The anterior cruciate ligament (ACL) is liable to a major injury that often results in a functional impairment requiring surgical reconstruction. The success of reconstruction depends on such factors as attachment positions, initial tension of ligament and surgical methods of fixation. The purpose of this study is to find isometric positions of the substitute during flexion/extension. The distance between selected attachments on the femur and tibia was computed from a set of measurements using a 6 degree-of-freedom magnetic sensor system. A three-dimensional knee model was constructed from CT images and was used to simulate length change during knee flexion/extension. This model was scaled for each subject. Twenty seven points on the tibia model and forty two points on the femur model were selected to calculate length change. This study determined the maximum and minimum distances to the tibial attachment during flexion/extension. The results showed that minimum length changes were $1.9{\sim}5.8mm$ (average $3.6{\pm}1.4mm$). The most isometric region was both the posterosuperior and anterior-diagonal areas from the over-the-top. The proposed method can be utilized and applied to an optimal reconstruction of ACL deficient knees.

CEPHALOMETRIC STUDY OF OBSTRUCTIVE SLEEP APNEA PATIENTS IN THE UPRIGHT AND SUPINE POSITIONS

  • Kim, Jong-Chul;Lowe, Alan A
    • The korean journal of orthodontics
    • /
    • v.25 no.6 s.53
    • /
    • pp.655-664
    • /
    • 1995
  • Sixty male patients with polysomnographically documented OSA were included in this study. A pair of cephalograms were obtained in the upright and supine positions. In the supine position, the ANB angle, lower facial height and the cross-sectional area of soft palate increased and there was a decrease in the vertical airway length and oropharynx cross-sectional area. Positional changes did not affect the cross-sectional area of tongue, but the cross-sectional area of the oropharynx decreased in the supine position. The obese group had higher AI and RDI. Maxillary unit length, C3-H, the cross-sectional areas of tongue, soft palate and oropharynx were significantly greater in the group Obese than in non-obese group. No correlation was noted between the mandibular unit length and OSA severity, The group of small mandibular unit length showed shorter lower facial height and maxillary unit length, and smaller cross-sectional area of tongue than the long mandibular unit length group. Hyold bone positioned more inferiorly and cross-sectional area of nasopharynx decreased as the OSA severity increased.

  • PDF

Synthesis and Characterization of Mononuclear Octahedral Fe(III) Complex Containing a Biomimetic Tripodal Ligand, N-(Benzimidazol-2-ylmethyl)iminodiacetic Acid

  • Moon, Do-Hyun;Kim, Jung-hyun;Lah, Myoung-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.10
    • /
    • pp.1597-1600
    • /
    • 2006
  • The mononuclear iron complex 1, $Fe^{III}$(Hbida)Cl($H_2O$), was synthesized using a tripodal tetradentate ligand, N-(benzimidazol-2-ylmethyl)iminodiacetic acid (H3bida), which has two carboxylate groups, one benzimida- zoyl group, and one tertiary amine where it serves as a tetradentate chelating ligand for the octahedral Fe(III) ion. The four equatorial positions of the octahedral complex are occupied by two monodentate carboxylates, a benzimidazole nitrogen, and an oxygen of a water molecule. One of the axial positions is occupied by an apical nitrogen of the Hbida and the other by a chloride anion. The mononuclear octahedral complex 1 mimics the geometry of the key intermediate structure of the catalytic reaction cycle proposed for the FeSODs, which is a distorted octahedral geometry with three histidyl imidazoles, an aspartyl carboxylate, a superoxide anion, and a water molecule. The redox potential of complex 1, $E_{1/2}$ is -0.11V vs. Ag/AgCl (0.12 V vs. NHE), which is slightly lower than those reported for the most FeSODs. The magnetic susceptibility of complex 1 at room temperature is 5.83 $\mu$B which is close to that of the spin only value, 5.92 $\mu$B of high-spin d5 Fe(III).

A Study on Web-based Mobile Mapping System Using Real-Time GPS/INS System (실시간 GPS/INS 시스템을 이용한 웹기반 모바일 매핑시스템 연구)

  • 이종기;김병국;권재현
    • Spatial Information Research
    • /
    • v.11 no.3
    • /
    • pp.291-299
    • /
    • 2003
  • The Mobile Mapping System collects geographic information through mounted sensors such as a pair of CCD camera, CPS, IMU(Inertial Measurement Unit) and Odometer at regular distance or time interval. The advantage of such system is to easy identification of positions and geographic informations of mobile objects in real time. Among many wireless communication ways for real-time positions and geographic information data from the mobile mapping system to the user such as PDA, wireless modem, cellophane, and web, the web is considered to be more stabile, effect and economic than any other methods. In this paper, a study on the web-based real-time mobile mapping platform to identify the user position is presented using the real-time NovAtel BDS.

  • PDF

A study on the North Korea's dentistry education system and its implication on the direction for integration of South and North Korea's dentistry education (북한의 치의학 교육 시스템을 통해 고찰해 본 남북한 치의학교육 통합방향에 대한 시사점)

  • Shin, Teo-Jeon;Han, Dong-Hun;Jin, Bo-Hyoung;Kim, Tae-Il;Lee, Jae-Il;Kim, Chong-Chul
    • The Journal of the Korean dental association
    • /
    • v.53 no.10
    • /
    • pp.726-731
    • /
    • 2015
  • There are big differences in dental education system between South Korea and North Korea. In North Korea, there is no college of dentistry and official license system and thus, dentists can treat a patient right after graduation from medical school. There are also positions such as paradentists capable of providing dental treatments, whereas such positions do not exist in South Korea. In this regards, in order to get ready for the United Korea, we need to establish a system designed to complement the differences in dentistry education and license system between South and North Korea. Such system would help to minimize the social cost in relation to the unification in near future.

Alignment System for Display Panel using Edge Feature (에지 특징을 이용한 디스플레이 패널 설비의 얼라인 시스템)

  • Lee, HoHun;Lee, DaeJong;Chun, MyungGeun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.25 no.3
    • /
    • pp.260-265
    • /
    • 2015
  • This paper proposes a alignment system using edge feature. An alignment system obtains the position and orientation of printed circuit board(PCB) or liquid crystal display(LCD) panel through the fiducial marks. Thus, it is the indicator of the system performance how accurate we detect the positions of the fiducial marks in the target image. Edges have the geometrical characteristics such as positions, lengths, and shapes. These features are suitable for finding the marks and have the advantages of lighting variations, model occlusion, as well as variations in scale and angle. The performance of the proposed system is validated through the alignment experiment using an display panel alignment system included X, Y axis, and rotatable stage.

THE NORMAL RANGE OF CONDYLAR MOVEMENT (하악골 운동시 과두의 이동범위에 관하여)

  • Choe Han Up
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.8 no.1
    • /
    • pp.43-47
    • /
    • 1978
  • The purpose of this study was to investigate the normal range of condylar movement of normal adults. The author has observed roentgenographic images of four serial positions of condylar head taken by modified transcranail lateral oblique projection. The serial positions are centric occlusion, rest position, 1 inch open position and maximal open position. The results were obtained as follow; 1. Inter-incisal distance was 46.85㎜ in maximal open position. 2. The length between the deepest point of glenoid fossa and summit of condylar head in rest position was wider than that in centric occlusion by 0.8㎜. 3. In 1 inch open position, condylar head moved forward from the standard line in 12.64㎜ of horizontal direction and moved downwards from the standard line in 1.84㎜ of vertical direction. 4. In maximal open position, condylar head moved forward from the standard line in 19.06㎜ of horizontal direction and moved downwards from thestanard line in 0.4㎜ of vertical direction. 5. In centric occlusion, the width between glenoid fossa and margin of condylar head was greater in the posterior portion than in the anterior portion by 0.4㎜. 6. Except for the estimated figures of 1 inch open position, all of the estimated figures was greater in male than in female.

  • PDF

The FEM Analysis on the Crestal Cortical Bone around the Implant according to the Cancellous Bone Density and Loading Positions (임프란트 매식시 해면골질의 차이에 따른 치밀골 상 응력분석)

  • Jeung, Sin-Young;Kim, Chang-Hyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.1
    • /
    • pp.69-78
    • /
    • 2007
  • This study was performed to compare the stress distribution pattern in the crestal cortical bone and cancellous bone using 3-dimensional finite element stress analysis when 2 different Young's modulus(high modulus, model 1; low modulus, model 2) of cancellous bone was assumed. For the analysis, a finite element model was designed to have two square-threaded implants fused together and located at first and second molar area. Stress distribution was observed when vertical load of 200N was applied at several points on the occlusal surfaces of the implants, including central fossa, points 1.5mm, 2mm, 3mm and 3.5mm buccally away from central fossa. The results were as follows; 1. In both model, the maximum Von-Mises stress in the crestal cortical bone was greater when the load was applied at the central point, points 1.5mm and 2mm buccally away from central fossa than other cases. 2. In the cortical bone around first and second molar, model 2 showed greater Von-Mises stress than model 1. It is concluded that when the occlusal contact is afforded, the distribution of stress varies depending on the density of cancellous bone and the location of loading. More favorable stress distribution is expected when the contact load is applied within the diameter of fixtures.