• Title/Summary/Keyword: positions

Search Result 6,435, Processing Time 0.031 seconds

Effects of Vibration on Passive Intermodulation Distortion in Mobile Base Station Antennas (이동 통신 기지국 안테나의 수동 상호 변조 왜곡에 진동이 미치는 영향 분석 및 개선 방안)

  • Park, Jin-Sung;Jung, Soon-Young;Lee, Yong-Shik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.12
    • /
    • pp.1394-1401
    • /
    • 2008
  • This work investigates the effects of vibration on the passive intermodulation distortion characteristics of base station antennas for 800 MHz CDMA mobile communication systems. In general, base station antennas are located at high positions such as on building rooftops or iron towers. Thus the antennas are always affected by random vibrations, coming from various natural environmental factors such as rain and wind, or from living environmental factors such as vehicles and trains passing by. The measured intermodulation distortion characteristics before and after vibration accelerated degradation test show that vibrations are indeed the main cause for the intermodulation distortion performances of such antennas. To minimize the effects of vibrations, a new antenna design isptoposed that has an improved tolerance for vibrations. Experimental results show that the proposed antenna design dramatically reduces the degradation of the intermodulation distortion more than 35 dB.

Sensibility Evaluation of Components of Middle and High-rise Apartment Facade in Aesthetic Old Town Districts of Kyoto - Extraction of Component Combinations Using Rough Set Theory - (쿄토시 구시가지형미관지구에서 중고층 집합주택 입면의 구성요소에 대한 감성평가 - 러프 집합을 이용한 구성요소 조합의 추출 -)

  • Shon, Dong-Hwa
    • Journal of the Korean housing association
    • /
    • v.25 no.3
    • /
    • pp.105-114
    • /
    • 2014
  • Landscape zones have been designated as aesthetic old town districts across a wide range of Nakakyo-Ku and Shimokyo-Ku, city center of Kyoto, Japan. In these districts in which traditional structures and new buildings coexist, regulations of restriction on acts such as new building's heights, shapes, materials, and colors are carried out according to local governmental landscape ordinance based on Scenic Conservation Act. And yet, minimal fulfillment of the regulations according to different designer's subjective interpretation and principle of economy is rather creating abnormal shapes not harmonized with the traditional landscape. Thus, this study aims to extract combinations between form elements of middle and high rise apartment facade that affects 'harmony' and 'mismatch' in the districts by clarifying the social rules commonly implied based on intuitive judgments (sensibility evaluation) in which human experiential knowledge is involved. As research methods, the study first analyzes the form elements of the facade through a field survey, sets up a standard model through tasks of classification and segmentation and draws computer graphic images with 99 different patterns based on it. Based on these images, this study carries out sensibility evaluation and analyzes experimental data applying the rough set theory. As a result of the analysis, the combinations of form elements that affect harmony or mismatch act greatly when the colors and shapes of the pillars, positions and the patterns of the use of the first floor are combined.

Facilitating Health Promotion Programs at the Local Level: An Educational Approach (지방자치단체의 건강증진사업 활성화 방안 -교육적 접근을 중심으로-)

  • 이명순
    • Korean Journal of Health Education and Promotion
    • /
    • v.16 no.2
    • /
    • pp.187-203
    • /
    • 1999
  • This paper will discuss about how we can foster educational support mechanisms to facilitate health promotion programs at the local level. Health promotion in Korea is in the early developmental stage; it has only been since the Health Promotion Act was legislated in 1995, the health promotion programs have been planned and implemented. In the context of the recent decentralization process, local health departments have a major responsibility for developing and implementing health promotion programs at the local level. The short history of health promotion in Korea has meant that local public health departments have limited experience and organizational capacity for health promotion planning & practice. The results of one survey for investigating the progress of health promotion at the local level are instructive. The survey demonstrated that the public health workers recognized that the lack of personnels, insufficient budget, the lack of policy & the organizational support, the lack of skill & knowledge to be effective health promotors, the lack of guidance for health promotion practice were major barriers to implementing health promotion programs at the local level. The object of this paper is to suggest some ways of overcoming barriers to implementing health promotion programs at the local level This paper emphasizes on the importance of educational supports as well as environmental supports - legislative, policy, organizational, economical - in building the organizational capacity and infrastructure of local health department for health promotion. It suggests some ways of providing educational supports to the public health workers at the local level. and supports the positions that educational opportunities for training in health promotion can be better provided to the public health workers at the provincial level rather than at the national level. It argues that the educational & training programs should be developed and based on the educational need assessment; that the application of the main educational principles & theoretical models for health promotion be used to develop educational programs for the public health workers; and that professional health organizations should make plans to provide more educational programs at their annual conferences or at other convenient times. These kinds of educational supports facilitate the ability of public health workers to improve their capacity for health promotion practice at the local level and help to alleviate some of the pressure on state resources.

  • PDF

Determinants Influencing Labor Union Commitment of Hospital Employees (병원직원의 노동조합몰입에 영향을 미치는 결정요인분석)

  • Sohn, Tae-Yong
    • Korea Journal of Hospital Management
    • /
    • v.12 no.1
    • /
    • pp.75-99
    • /
    • 2007
  • The purpose of this study was to provide basic materials needed to enhance quality of organizational life by identifying the improvements of labor union management in the perspective of general hospital organization management. The subjects of this study were 428 employees in 8 Hospitals in Metro Capital including Seoul. Materials were collected from administrators, nurses and medical technicians in target hospitals from November 10 to November 30, 2006 through survey questionnaires. The main results of this study were as follows: 1. The commitment level of the subjects according to their characteristics was higher in older employees than the younger ones, large family to support than small family to support and those who had higher positions in labor union. 2. The commitment level of the subjects according to the Job and role related variables were higher those who had higher satisfaction level to their job, role conflict in all hospitals. 3. The commitment level of the subjects according to union related variables, variables jointly controlled by union and employer was statistically significant positive correlation. 4. The results of multiple regression analysis shows that formal and informal socialization, satisfaction with the labor union's were all found as important antecedents of labor union commitment. 5. The results of AMOS shows that structure characteristics of hospital, Job and manager satisfaction, socialization were statistically significant labor union satisfaction. The satisfaction level of labor union was statistically significant labor union commitment To summarize study results, the level of commitment in labor union depends on job satisfaction, managers' attitudes, union satisfaction factors, their colleagues attitudes toward union. Therefore hospital managers should have democratic and flexible attitudes toward labor union. Additionally, as formal and informal socialization is important determinant in union commitment, hospital managers should have countermeasures to enhance the colleague attitude and job satisfaction level of hospital employees. Moreover, as managerial factors of the principal of hospital influence union commitment directly, the attitudes of hospital managers toward union and transparency of hospital management should be improved.

  • PDF

Commissioning result of the KSTAR in-vessel cryo-pump

  • Chang, Y.B.;Lee, H.J.;Park, Y.M.;Lee, Y.J.;Kwag, S.W.;Song, N.H.;Park, D.S.;Joo, J.J.;Moon, K.M.;Kim, N.W.;Yang, H.L.;Oh, Y.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.4
    • /
    • pp.53-58
    • /
    • 2013
  • KSTAR in-vessel cryo-pump has been installed in the vacuum vessel top and bottom side with up-down symmetry for the better plasma density control in the D-shape H-mode. The cryogenic helium lines of the in-vessel cryo-pump are located at the vertical positions from the vacuum vessel torus center 2,000 mm. The inductive electrical potential has been optimized to reduce risk of electrical breakdown during plasma disruption. In-vessel cryo-pump consists of three parts of coaxial circular shape components; cryo-panel, thermal shield and particle shield. The cryo-panel is cooled down to below 4.5 K. The cryo-panel and thermal shields were made by Inconel 625 tube for higher mechanical strength. The thermal shields and their cooling tubes were annealed in air environment to improve the thermal radiation emissivity on the surface. Surface of cryo-panel was electro-polished to minimize the thermal radiation heat load. The in-vessel cryo-pump was pre-assembled on a test bed in 180 degree segment base. The leak test was carried out after the thermal shock between room temperature to $LN_2$ one before installing them into vacuum vessel. Two segments were welded together in the vacuum vessel and final leak test was performed after the thermal shock. Commissioning of the in-vessel cryo-pump was carried out using a temporary liquid helium supply system.

Paramagnetic Zn(1-x)MnxO (0.00≤x≤0.06) Nanoparticles Prepared by The Coprecipitation Method

  • Harsono, Heru;Wardana, I Nyoman Gede;Sonief, Achmad As'ad;Darminto, Darminto
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.1
    • /
    • pp.46-50
    • /
    • 2017
  • The Zn1-xMnxO ($0.00{\leq}x{\leq}0.06$) samples have been synthesized in the form of powder by the coprecipitation method at low temperature using $Zn(CH_3COO)_2$. $2H_2O$ and $Mn(CH_3COO)_2$. $4H_2O$ powders, as well as HCl and $NH_4OH$ solutions as starting materials. Characterization was conducted using XRD, TEM, XRF, FTIR and VSM. The result shows that the $Zn_{(1-x)}Mn_xO$ ($0.00{\leq}x{\leq}0.06$) nanoparticles have the wurtzite phase with a hexagonal structure and particle sizes ranging from 17.48 to 118.83 nm. In a qualitative analysis of XRF, the peaks that confirm the existence of the manganese element in Mn-doped ZnO samples were observed. Meanwhile, FTIR test result shows that there are peaks at around $500cm^{-1}$ and $400cm^{-1}$ in the FTIR spectra for Mn doped ZnO samples which clearly reveal the existence of the (Zn, Mn)-O strain mode. The (Zn, Mn)-O absorption peak positions have shifted to a lower wave number with increasing Mn doping content. The peak intensity is also lower if compared to that of the ZnO sample without doping. From the VSM test, it is shown that $Zn_{(1-x)}Mn_xO$ ($0.00{\leq}x{\leq}0.06$) nanoparticles are all paramagnetic having monotonically increased susceptibility as increasing Mn content.

Development of Joint Angle Measurement System for the Feedback Control in FES Locomotion (FES보행중의 피드백제어를 위한 관절 각도계측 시스템 개발)

  • Moon, Ki-Wook;Kim, Chul-Seung;Kim, Ji-Won;Lee, Jea-Ho;Kwon, Yu-Ri;Kang, Dong-Won;Khang, Gon;Kim, Yo-Han;Eom, Gwang-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.203-209
    • /
    • 2009
  • The purpose of this study is to develop a minimally constraint joint angle measurement system for the feedback control of FES (functional electrical stimulation) locomotion. Feedback control is desirable for the efficient FES locomotion, however, the simple on-off control schemes are mainly used in clinic because the currently available angle measurement systems are heavily constraint or cosmetically poor. We designed a new angle measurement system consisting of a magnet and magnetic sensors located below and above the ankle joint, respectively, in the rear side of ipsilateral leg. Two magnetic sensors are arranged so that the sensing axes are perpendicular each other. Multiple positions of sensors attachment on the shank part of the ankle joint model and also human ankle joint were selected and the accuracy of the measured angle at each position was investigated. The reference ankle joint angle was measured by potentiometer and motion capture system. The ankle joint angle was determined from the fitting curve of the reference angle and magnetic flux density relationship. The errors of the measured angle were calculated at each sensor position for the ankle range of motion (ROM) $-20{\sim}15$ degrees (dorsiflexion as positive) which covers the ankle ROM of both stroke patients and normal subjects during locomotion. The error was the smallest with the sensor at the position 1 which was the nearest position to the ankle joint. In case of human experiment, the RMS (root mean square) errors were $0.51{\pm}1.78(0.31{\sim}0.64)$ degrees and the maximum errors were $1.19{\pm}0.46(0.68{\sim}1.58)$ degrees. The proposed system is less constraint and cosmetically better than the existing angle measurement system because the wires are not needed.

THE EFFECT OF CLASP DESIGN ON ABUTMENT TOOTH MOVEMENT FOR DISTAL EXTENSION REMOVABLE PARTIAL DENTURE (유리단 국소의치의 Clasp설계가 지대치 운동에 미치는 영향)

  • Yim, Soon-Ho;Chang, Ik-Tai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.25 no.1
    • /
    • pp.17-40
    • /
    • 1987
  • The purpose of this study was to clarify the effect of clasp design on abutment tooth adjacent to a distal extension base under the influence by the location of functional loading. The RPI clasp, the Akers clasp and the combination clasp were selected for evaluation. Tests were performed at 10Kg, 20Kg, 30Kg loads on the buccal, central, lingual, mesial and distal positions of loading platform of each mandibular distal extension partial denture. The laser reflexion method was used for three dimensional measurement of abutment movement, which is possible to measure precisely without contact. The movement in the mesiodistal(X), buccolingual(Y), and occlusoapical(Z) directions and the rotational movement(R) were measured, and in addition, the total movement (SV) as expressed by the three dimensional summation vector independent of direction was calculated. The data were analyzed using Student t-test, p<.05. The following results were obtained from this study; 1. Clasp design did not generally affect the direction of abutment tooth movement except the movement in an undesirable occlusal direction in case of the Akers clasp and the combination clasp. 2. The greater the load on the prosthesis, the greater was the abutment tooth movement, and the direction of abutment tooth movement was affected by positional loading. 3. Each prosthesis was dislodged from the test base under the small amount of load in the distal load position, and the buccal loading showed the greatest abutment tooth movement under the maximum load. 4. RPI clasp was evaluated as the most favorable design.

  • PDF

A STUDY ON SIMULATION OF THE MANDIBULAR MOVEMENT OF THE PATIENTS WITH TEMPOROMANDIBULAR JOINT DISORDER (측두하악 장애환자의 하악 운동 Simulation에 관한 연구)

  • Park, Sang-Yoon;Kang, Dong-Wan;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.161-175
    • /
    • 1991
  • To understand the biomechanics of the mandibular movement of the patients with T.M.J. disorder, it is necessary to analyze the mandibular movement by the least moving points of instantaneous center of rotation on computer screen. In this study, two subjects without T.M.J. disorder and with normal occlusion and few patients with T.M.J. disorder were selected for obtaining the processing data. The habitual opening and dosing movements were recorded by image recognition system of video and computer and then the mandibular movement and the least moving point were analyzed using computer program for image anaysis of specialized points. The results obtained were as follows: 1. The least moving points of control group during opening and dosing were dose to the mandibular foramen, but in the test group there were differences between two positions of the least moving points during opening and closing. 2. The variations of the least moving point were in the range of $0.02\sim0.05cm$ of X-coordinate and $0.07\sim0.10cm$ of Y-coordinate for control group, whereas in the range of $0.05\sim0.30cm$ of X-coordinate and $0.08\sim1.65cm$ of Y-coordinate for test group. 3. The index of variation during opening and dosing movements was shown in $0.8\sim1.0$ for the control group and in $0.56\sim2.6$ for the test group. 4. After the treatment of the test group No. 4 by occlusal splint the least moving point was dose to the mandibular foramen and the index of variation was changed from 25 to 05. 5. The tracing shape of the least moving point in the test group represented the irregularities compared to the control group. 6. The mandibular opening and dosing movements were simulated on the computer screen following the movement of the least moving point of instantaneous center of rotation.

  • PDF

Rotordynamic Design of a LOX Pump for a 75 Ton Class Liquid Rocket Engine (75톤급 액체로켓 엔진용 산화제 펌프 회전체 동역학 설계)

  • Jeon, Seong-Min;Kwak, Hyun-D.;Yoon, Suk-Hwan;Kim, Jin-Han
    • Aerospace Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.205-210
    • /
    • 2007
  • A LOX pump rotordynamic design was performed for a 75 ton thrust liquid rocket engine. Axial positions of an inducer, an impeller and bearings on a shaft are decided on the basis of the experience achieved by previously developed turbopump which has the similar layout. The result of pump hydraulic design was reflected in the present study to decide axial length of the inducer and impeller. A distance from the rear bearing to the impeller was considered as a design parameter for load distribution of the bearings. Asynchronous eigenvalue analysis was performed as a function of rotating speeds and bearing stiffness to investigate critical speed of the LOX pump. From the numerical analysis, it is found that the LOX pump with the proper bearing loads safely operates as a sub-critical rotor of which critical speed is high enough compared to the operating speed 11,000 rpm.

  • PDF