• Title/Summary/Keyword: position measurement

Search Result 2,303, Processing Time 0.039 seconds

Analysis of Dose Delivery Error in Conformal Arc Therapy Depending on Target Positions and Arc Trajectories (동적조형회전조사 시 표적종양의 위치변위와 조사반경의 변화에 따른 선량전달 오류분석)

  • Kang, Min-Young;Lee, Bo-Ram;Kim, You-Hyun;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.34 no.1
    • /
    • pp.51-58
    • /
    • 2011
  • The aim of the study is to analyze the dose delivery error depending on the depth variation according to target positions and arc trajectories by comparing the simulated treatment planning with the actual dose delivery in conformal arc therapy. We simulated the conformal arc treatment planning with the three target positions (center, 2.5 cm, and 5 cm in the phantom). For the experiments, IMRT body phantom (I’mRT Phantom, Wellhofer Dosimetry, Germany) was used for treatment planning with CT (Computed Tomography, Light speed 16, GE, USA). The simulated treatment plans were established by three different target positions using treatment planning system (Eclipse, ver. 6.5, VMS, Palo Alto, USA). The radiochromic film (Gafchromic EBT2, ISP, Wayne, USA) and dose analysis software (OmniPro-IMRT, ver. 1.4, Wellhofer Dosimetry, Germany) were used for the measurement of the planned arc delivery using 6 MV photon beam from linear accelerator (CL21EX, VMS, Palo Alto, USA). Gamma index (DD: 3%, DTA: 2 mm) histogram and dose profile were evaluated for a quantitative analysis. The dose distributions surrounded by targets were also compared with each plans and measurements by conformity index (CI), and homogeneity index (HI). The area covered by 100% isodose line was compared to the whole target area. The results for the 5 cm-shifted target plan show that 23.8%, 35.6%, and 37% for multiple conformal arc therapy (MCAT), single conformal arc therapy (SCAT), and multiple static beam therapy, respectively. In the 2.5 cm-shifted target plan, it was shown that 61%, 21.5%, and 14.2%, while in case of center-located target, 70.5%, 14.1%, and 36.3% for MCAT, SCAT, and multiple static beam therapy, respectively. The values were resulted by most superior in the MCAT, except the case of the 5 cm-shifted target. In the analysis of gamma index histogram, it was resulted of 37.1, 27.3, 29.2 in the SCAT, while 9.2, 8.4, 10.3 in the MCAT, for the target positions of center, shifted 2.5 cm and 5 cm, respectively. The fail proportions of the SCAT were 2.8 to 4 times as compared to those of the MCAT. In conclusion, dose delivery error could be occurred depending on the target positions and arc trajectories. Hence, if the target were located in the biased position, the accurate dose delivery could be performed through the optimization of depth according to arc trajectory.

Optimization of Subtraction Brain Perfusion SPECT with Basal/Acetazolamide Consecutive Acquisition (기저/아세타졸아미드 부하 연속 촬영 뇌관류 SPECT 최적화)

  • Lee, Dong-Soo;Lee, Tae-Hoon;Kim, Kyeong-Min;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.330-338
    • /
    • 1997
  • This study investigated the method to adjust acquisition time(a) and injection dose (i) to make the best basal and subtraction images in consecutive SPECT. Image quality was assumed to be mainly affected by signal to noise ratio(S/N). Basal image was subtracted from the second image consecutively acquired at the same position. We calculated S/N ratio in basal SPECT images($S_1/N_1$) and subtraction SPECT images(Ss/Ns) to find a(time) and i(dose) to maximize S/N of both images at the same time. From phantom images, we drew the relation of image counts and a(time) and i(dose) in our system using fanbeam-high-resolution collimated triple head SPECT. Noise by imaging process depended on Poisson distribution. We took maximum tolerable duration of consecutive acquisition as 30 minutes and maximum injectible dose as 1,850MBq(50 mCi)(sum of two injections) per study. Counts of second-acquired image($S_2$), counts($S_s$) and noise($N_s$) of subtraction SPECT were as follows. $C_1$ was the coefficient of measurement with our system. $$S_2=S_1{\cdot}(\frac{30-a}{a})+background{\cdot}(1-\frac{30-a}{a})+C_1{\cdot}(30-a){\cdot}{\epsilon}{\cdot}(50-i)$$ $$Ss=S_2-\{S_1{\cdot}(\frac{30-a}{a})+background{\cdot}(1-\frac{(30-a)}{a})\}$$ $$Ns={\sqrt{N_2^2+N_1^2{\cdot}\frac{(30-a)^2}{a^2}}={\sqrt{S_2+S_1{\cdot}\frac{(30-a)^2}{a^2}}$$ In case of rest/acetazolamide study, effect(${\epsilon}$) of acetazolamide to increase global brain uptake of Tc-99m-HMPAO could be 1.5 or less. Varying ${\epsilon}$ from 1 to 1.5, a(time) and i(dose) pair to maximize both $S_1/N_l$ and Ss/Ns was determined. 15 mCi/17 min and 35mCi/13min was the best a(time) and i(dose) pair for rest/acetazolamide study(when ${\epsilon}$ were 1.2) and came to be used for our clinical routine after this study. We developed simple method to maximize S/N ratios of basal and subtraction SPECT from consecutive acquisition. This method could be applied to ECD/HMPAO and brain activation studies as well as rest/acetazolamide studies.

  • PDF

Patients with brain metastases the usefulness of contrast-enhanced FLAIR images after delay (뇌전이 환자의 조영 증강 후 지연 FLAIR 영상의 유용성)

  • Byun, Jae-Hu;Park, Myung-Hwan;Lee, Jin-Wan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.1
    • /
    • pp.13-19
    • /
    • 2014
  • Purpose: FLAIR image is beneficial for the diagnosis of various bran diseases including ischemic CVS, brain tumors and infections. However the border between the legion of brain metastasis and surrounding edema may not be clear. Therefore, this study aims to investigate the practical benefits of delayed imaging by comparing the image from a patient with brain metastasis before a contrast enhancement and the image 10 minutes after a contrast enhancement. Materials and methods: Of the 92 people who underwent MRI brain metastases in suspected patients 13 people in three patients there is no video to target the 37 people confirmed cases, and motion artifacts brain metastases in our hospital June-December 2013, 18 people measurement position except for the three incorrect patient (male: 11 people, female: 7 people, average age: 60 years) in the target, test equipment, 3.0T MR System (ACHIEVA Release, Philips, I was 8ChannelSENSE Head Coil use Best, and the Netherlands). TR 11000 ms, TE 125 ms, TI2800 ms, Slice Thickness 5 mm, gap 5 mm, is a Slice number 21, the parameters of the 3D FFE, T2 FLAIR variable that was used to test, TR 8.1 ms, TE 3.7 ms, Slice number 240 I set to. The experiment was conducted by acquiring the FLAIR prior to contrast enhancement (heretofore referred to as Pre FLAIR), and acquiring the 3D FFE CE five minutes after the contrast enhancement, and recomposing the images in an axial plane of S/T 3mm, G 0mm (heretofore referred to as MPR TRA CE). Using the FLAIR 10 minutes after the contrast enhancement (heretofore referred to as Post FLAIR) and Pi-View, a retrospective study was conducted. Using MRIcro on the image of a patient confirmed for his diagnosis, the images before and after the contrast media, as well as the CNR and SNR of the MPR TRA CE images of the lesion and the site absent of lesion were compared and analyzed using a one-way analysis of variance. Results: CNR for Pre FLAIR and Post FLAIR were 34.35 and 60.13, respectively, with MPR TRA CE at 23.77 showing no significant difference (p<0.050). Post-experiment analysis shows a difference between Pre FLAIR and Post FLAIR in terms of CNR (p<0.050), but no difference in CNR between Post FLAIR and MPR TRA CE (p>0.050), indicating that the contrast media had an effect only on Pre FLAIR and Post FLAIR. The SNR for the normal site Pre FLAIR was 106.43, and for the lesion site 140.79. Post FLAIR for the normal site was 107.79, and for the lesion site 167.91. MPR TRA CE for the normal site was 140.23 and for the lesion site 183.19, showing significant difference (p<0.050), and post-experiment analysis shows that there was a difference in SNR only on the lesion sites for Pre FLAIR and Post FLAIR (p<0.050). There was no difference in SNR between the normal site and lesion site for Post FLAIR and MPR TRA CE, indicating no effect from the contrast media (p>0.050). Conclusions: This experiment shows that Post FLAIR has a higher contrast than Pre FLAIR, and a higher SNR for lesions, It was not not statistically significant and MPR TRA CE but CNR came out high. Inspection of post-contrast which is used in a high magnetic field is frequently used images of 3D T1 but, since the signal of the contrast medium and the blood flow is included, this method can be diagnostic accuracy is reduced, it is believed that when used in combination with Post FLAIR, and that can provide video information added to the diagnosis of brain metastases.

  • PDF

Needs on Management Development Program for Head Nurse (간호 관리 능력 개발을 위한 교육 연구)

  • Park, Jeong-Sun
    • Journal of Home Health Care Nursing
    • /
    • v.5
    • /
    • pp.84-99
    • /
    • 1998
  • The objectives of this study are to identify the actual educational contents of management for head nurse and to propose the educational subjects according to identity the needs of head, charge, and staff nurses. The subjects were investigated the actual Management Development Programs and educational needs of head nurses and prospective nurse manager(charge nurse, staff nurse with a lot of clinical experiences) in general hospitals. The tools were composed of two questionnaires: One was developed from the literature review for making items to measure actual situation. The other was revised Katz's model for measurement of educational needs. The first respondents of actual situation were 27 general hospitals with over 400 beds in Seoul and the second respondents were 89 head nurses, 67 charge nurses and 136 nurses at 3 hospitals by convenient sampling out of 27 general hospitals. Data were collected by telephone interview, mail questionnaire and visiting from 7th of October through 30th of November in 1997. In data analysis, general characteristics of the respondents and actual status of Management Development Programs were analyzed by frequency and percentage. Educational needs according to general characteristics were analyzed by ANOVA The results were as follows: 1. Actual situation of Management Development Program 1) Seven hospitals(26%) had Management Development Program for prospective managers and 14 hospitals (52%) for head nurses. 2) Education Department existed in 14 hospitals (52%). 3) One hospital(4%) had top level managers took part in the Management Development. 4) Two hospitals selected head nurse, who had finished courses of Management Development. Eight hospitals(30%) assessed educational needs. The assessment tools consisted of making a question via questionnaire(75%), determining at department meeting(12%) and interview(13%). 5) Educational programs had 3 types: 10 lecture type, 7 discussion type and 4 role play type programs. 6) One hospital evaluated the change of learner's attitude. 7) Four hospitals scored educational point, but that was measured only by attending. 8) Actual Management Development Programs were as follows. parenthesis indicates the number of hospitals. (1) Management Development Programs for Prospective manager. Role perception of Middle level Manager (1) . Role reconstruction of Nurse Manager (1). Workshop for Charge Nurse (1). Nursing Delivery System and Nursing Process (1). Communication (1). Motivation (1) (2) Management Development Programs for Head nurse.. Head nurse's Role (5). Administrative Work (7). Service Education (4). Prevention and Countermeasure of Nursing Incidence (3). Appraisal (3) 2. The results of needs on Management Development subject 1) The educational needs of all respondents on 3 skill domains showed positive agreement to strongly positive agreement. 2) High priority(more than 4.5) items were 12 of 24 Human skill items(50%), 1 of 6 Technical skill items(16%), and 2 of 13 Conceptual skill items (15%). 3) Out of high priority items, 8 items were instituted. 4) All respondents showed high needs on 3 skill domains regardless of 3 positions (head nurse, charge nurse, and nurse). Educational needs of Human skill domain, according to position were 108. S, 108.7, 106.8 (mean score = 72) , needs of Technical skill domain were 26.5, 26.6, 26.I(mean score=18), and needs of Conceptual skill domains were 56.9,56.7, 55.1(mean score=39). 5) Needs of 3 skill domains according to clinical career showed significant difference. Out of respondents, nurses with career of over 16years showed lowest degree of needs in Human skill domains(F=4.47, P=.004) and Conceptual skill domain(F=2.93, P=.034). 6) Educational needs according to educational background were not significant difference. But out of respondents, nurses educated at 3-year junior college relatively showed lowest needs in all of the 3 skill domains. With the above-mentioned findings, further study is necessary for generalization of this study at hospitals with different bed size and location. Also it is needed to study about management skill of nurse and charge nurse, and effective educational method.

  • PDF

Developing an Instrument for Analysing Students' Behavioral Engagement in School Science Classroom (과학수업에서 나타나는 학생들의 행동적 참여 분석을 위한 영상 분석 도구의 개발)

  • Choi, Joonyoung;Na, Jiyeon;Song, Jinwoong
    • Journal of The Korean Association For Science Education
    • /
    • v.35 no.2
    • /
    • pp.247-258
    • /
    • 2015
  • Students are engaged in classroom learning, and classroom learning occurs not only through conversation but also through nonverbal behavior. In science classrooms especially, there are meaningful nonverbal behaviors such as practical activities like observation and measurement. But these behaviors have not been properly investigated by existing instruments that try to measure students' engagement. This study aims to develop a new instrument for analyzing students' behavioral engagement especially in science classrooms. The method of developing the instrument was structured along three steps. First, student behaviors have been classified into fourteen categories through literature review and a series of observation of elementary science classroom. Second, based on these, a framework for analyzing student behavioral engagement has been developed. With the framework, every student moment could be labeled as Participatory Speech or Participatory Silence or Non-Participatory Speech or Non-Participatory Silence. Third, an instrument to which the framework is applied has been developed by using Microsoft Excel. As a trial, two fourth-grade students in elementary science class were analyzed with this instrument. The results of the trial analysis shows that the longest period of a science lesson was occupied by Participatory Silence (63% and 72%). Among the participatory silence, 'listening' was the most common (51% and 42% of the trial lesson) and 'observing' which is a specific behavior to science was the fourth position (17% and 17% of the trial lesson). It is expected that the developed instrument could be used in improving our understanding of the patterns of student engagement in science classrooms.

Managing Technological Risk and Risk Conflict : Public Debates on Health Risks of Mobile Phones EMF (기술위험 관리와 위험갈등 : 휴대전화 전자파의 인체유해성 논란)

  • Jung, Byung-Kul
    • Journal of Science and Technology Studies
    • /
    • v.8 no.1
    • /
    • pp.97-129
    • /
    • 2008
  • We are living in the time of high probability of technological risk due to increased rate of technology development and diffusion of new technologies. Resolving uncertainties, the basic attribution of risk, by accumulating knowledge over the risk factors of certain technology is critical to management of technological risk. In many cases of technological risks, high uncertainty of knowledge is commonly mentioned reason for public controversies on risk management. However, the type of technological risk with low social agreement and low uncertainty of knowledge, the main reason for public controversy is absence of social agreement. Public debates on the risks of mobile phones electromagnetic fields(EMF) to human health comes under this category. The knowledge uncertainty on human health effect of mobile phones EMF has been lowered increasingly by accumulating enormous volume of knowledge though scientists have not reached a final conclusion whether it pose a risk to the physical and mental health of the general population or not. In contrast with civil organizations calling for precautionary approach based regulation, the mobile phone industry is cling to the position of no-regulation-needed by arguing no clear evidence to prove health risks of mobile phone EMF has found. In Korea, government set exposure standards based on a measurement called the 'specific absorption rate'(SAR) and require the mobile phone industry to open SAR information to the public by their own decision. From the view of pro-regulation side based on precautionary approach, technology risk managament of mobile phones EMF in Korea is highly limited and formalized one with limited measuring of SAR on head part only and problematic self-regulated opening of information about SAR to the public. As far as the government keeps having priority on protecting interest of mobile phone industry over precautionary regulation of mobile phones EMF, the disagreement between civil organizations and the government will not resolved. The risk of mobile phones EMF to human health have high probability of being underestimated in the rate and damage of risk than objectively estimated ones due to familiarity of mobile phone technology. And this can be the cause of destructive social dispute or devastating disaster. To prevent such disastrous results, technology risk management, which integrating the goals of safety with economic growth in public policy and designing and promoting risk communication, is required.

  • PDF

Evaluation of Real-time Measurement Liver Tumor's Movement and $Synchrony^{TM}$ System's Accuracy of Radiosurgery using a Robot CyberKnife (로봇사이버나이프를 이용한 간 종양의 실시간 움직임 측정과 방사선수술 시 호흡추적장치의 정확성 평가)

  • Kim, Gha-Jung;Shim, Su-Jung;Kim, Jeong-Ho;Min, Chul-Kee;Chung, Weon-Kuu
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.263-270
    • /
    • 2008
  • Purpose: This study aimed to quantitatively measure the movement of tumors in real-time and evaluate the treatment accuracy, during the treatment of a liver tumor patient, who underwent radiosurgery with a Synchrony Respiratory motion tracking system of a robot CyberKnife. Materials and Methods: The study subjects included 24 liver tumor patients who underwent CyberKnife treatment, which included 64 times of treatment with the Synchrony Respiratory motion tracking system ($Synchrony^{TM}$). The treatment involved inserting 4 to 6 acupuncture needles into the vicinity of the liver tumor in all the patients using ultrasonography as a guide. A treatment plan was set up using the CT images for treatment planning uses. The position of the acupuncture needle was identified for every treatment time by Digitally Reconstructed Radiography (DRR) prepared at the time of treatment planning and X-ray images photographed in real-time. Subsequent results were stored through a Motion Tracking System (MTS) using the Mtsmain.log treatment file. In this way, movement of the tumor was measured. Besides, the accuracy of radiosurgery using CyberKnife was evaluated by the correlation errors between the real-time positions of the acupuncture needles and the predicted coordinates. Results: The maximum and the average translational movement of the liver tumor were measured 23.5 mm and $13.9{\pm}5.5\;mm$, respectively from the superior to the inferior direction, 3.9 mm and $1.9{\pm}0.9mm$, respectively from left to right, and 8.3 mm and $4.9{\pm}1.9\;mm$, respectively from the anterior to the posterior direction. The maximum and the average rotational movement of the liver tumor were measured to be $3.3^{\circ}$ and $2.6{\pm}1.3^{\circ}$, respectively for X (Left-Right) axis rotation, $4.8^{\circ}$ and $2.3{\pm}1.0^{\circ}$, respectively for Y (Crania-Caudal) axis rotation, $3.9^{\circ}$ and $2.8{\pm}1.1^{\circ}$, respectively for Z (Anterior-Posterior) axis rotation. In addition, the average correlation error, which represents the treatment's accuracy was $1.1{\pm}0.7\;mm$. Conclusion: In this study real-time movement of a liver tumor during the radiosurgery could be verified quantitatively and the accuracy of the radiosurgery with the Synchrony Respiratory motion tracking system of robot could be evaluated. On this basis, the decision of treatment volume in radiosurgery or conventional radiotherapy and useful information on the movement of liver tumor are supposed to be provided.

Size and Retention of Tongue Bulb for Tongue Retaining Device (혀 유지구의 크기와 유지력 평가)

  • Park, Nam-Seon;Lee, Ki-Ho;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.3
    • /
    • pp.283-292
    • /
    • 2007
  • In several treatment modalities for snoring and obstructive sleep apnea (OSA), oral appliances mainly including mandibular advancement appliance (MAA) and tongue retaining device (TRD) are recognized as a non-invasive, reversible alternative with favorable results. Tongue bulb is a major component of TRD which prevents the tongue from approaching the posterior wall of the pharynx and can be combined with MAA. Determination of tongue bulb size for the patient is important for therapeutic effect, but frequently needs time-consuming work. For effective fabrication and standardization of tongue bulbs, this study aimed to categorize tongue bulb size for healthy young men and to examine its relation with maximum retention force and with physical parameters including tongue-related variables. 36 non-snoring, asymptomatic young men with normal occlusion were voluntarily participated in this study (mean age: $24.47{\pm}2.58$ years). Experimental procedures consisted of prefabrication of tongue bulb set (20 types with a width of 27-36mm and thickness of 8 and 10 mm), determination of tongue bulb size and the maximum retention force for each subject, and measurement of physical parameters including body mass index (BMI), neck circumference and width, thickness and length of tongue. This study showed that there was significant difference of retention force among the bulb size-related groups both in upright and supine position (p<0.05) and that retention force increased with bulb size. Correlation of tongue bulb size with physical parameters was not clearly verified and there was no significant difference in retention force between upright and supine positions. Based on our results, it can be suggested that retention force relates with tongue bulb size, ultimately with tongue volume. A further study needs to be performed in the patients with snoring and OSA.

THREE DIMENSIONAL ANALYSIS OF MAXILLOFACIAL STRUCTURE BY FRONTAL AND LATERAL CEPHALOGRAM (두부 방사선 규격사진을 이용한 악안면 구조의 3차원적 분석법)

  • Kwon, Kui-Young;Lee, Sang-Han;Kwon, Tae-Geon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.21 no.2
    • /
    • pp.174-188
    • /
    • 1999
  • The purpose of this study is to evaluate the precision and accuracy of a three dimensional cephalogram constructed by using the frontal and lateral cephalogram of twelve human dry skulls. After achieving the three dimensional image reconstruction program, we tried to apply this program to two dentofacial deformity patients. 1. Conventional nasion relator in cephalostat was used to reproduce the same head position for the same dry skull. The mean difference of the three dimensional cephalogram for the same dry skull was $0.34{\pm}0.33mm$. Closeness of repeated measures to each skull reveals the precision of this method for the three dimensional cephalogram. 2. Concerning the accuracy, the mean difference between the three dimensional reconstruction data and actual lineal measurements was $1.47{\pm}1.45mm$ and the mean magnification ratio was $100.24{\pm}4.68%$. This Diffrerence is attributed mainly to the ill defined cephalometric landmarks, not to the positional change of the dry skull. 3. Cephalometric measurement of lateral and frontal radiographs had no consecutive magnification ratio because of the different focus-object distance. The mean difference between the frontal and lateral cephalogram to the actual lineal measurements was $4.72{\pm}2.01mm$ and $-5.22{\pm}3.36mm$. Vertical measurements were slightly more accurate than horizontal measurements. 4. Applying to the actual patient analysis, it is recommendable to use this program for analyzing the asymmetry or spatial change after operation. The orthodontic bracket would be a favorable cephalometric landmark for constructing the three dimensional images.

  • PDF

The Comparison Research of the Head and Face on the 30's, 40's, and the 50's, 60's in Korean Men according to Sasang Constitution (한국인(韓國人) 남자(男子) 30-40대(代)와 50-60대(代)의 사상체질별(四象體質別) 안면형태(顔面形態)에 관(關)한 비교(比較) 연구(硏究))

  • Lim, Kyu-Seong;Kim, Sang-Bok;Lee, Jun-Hee;Park, Gye-Soo;Lee, Su-Kyung;Lee, Eui-Ju;Koh, Byung-Hee;Song, Il-Byung;Yun, Jong-Hyun
    • Journal of Sasang Constitutional Medicine
    • /
    • v.12 no.2
    • /
    • pp.143-152
    • /
    • 2000
  • 1. Background and Purpose The faces of human being change as they grow older. We could know the characters of the each ages, through the facial comparison between the 30's, 40's and the 50's, 60's. As a conclusion, I carried out this Study because I thought that the errors of diagnosis would be reduced a lot through the standardization researches about the morphology of faces. 2. Objectives The object of this study is selected from the patients who were already diagnosed Sasang Constitutions at the department of Sasang Constitutional Medicine in Kyunghee Oriental Medical Center. The number of the patients were 69 men in 30's and 40's, and 74 men in 50's and 60's. 3. Method I took the photographs of front view and lateral view of the objectives by digital camera and obtained the 200 measure through the facial measurement program. I compared the measure of 50's and 60's with 30's and 40's by independant t-test. 4. Results 28 measures are different 30's and 40's with 50's and 60's in Soyangin, 31 measures in Soeumin, 40 measures in Taeumin. 5. Conclusion (1) Soyangin showed wider interpupillary distance in 30's and 40's than 50's and 60's. They also showed the large brow and cheek and their lips were thick and prominent and their ophyrion were prominent and their noses were wide and large and they showed wide bigonial breadth in 30's and 40's than 50's and 60's. (2) Soeumin showed the position of ears were higher and the brows were longer and larger in 30's and 40's than 50's and 60's. The width of both eyebrow were wider in 50's and 60's than 30's and 40's. The lower 2/3 portion of the face was longer and the shape of head was longer in vertical in 50's and 60's than 30's and 40's. (3) Taeumin showed the wider brow in 30's and 40's than 50's and 60's. The width of each eyes was wider and the width of cheek and face was larger, too. The ophyrion was prominent and the mouth was bigger and the face showed longer in 50's and 60's than 30's and 40's. (4) The upper 1/3 portion of the face was large in 30's and 40's and the lower 2/3 portion of the face showed large and long in 50's and 60's regardless Constitution.

  • PDF