• 제목/요약/키워드: position marking technique.

검색결과 5건 처리시간 0.02초

The Failure Mode and Effects Analysis Implementation for Laser Marking Process Improvement: A Case Study

  • Deng, Wei-Jaw;Chiu, Chung-Ching;Tsai, Chih-Hung
    • International Journal of Quality Innovation
    • /
    • 제8권1호
    • /
    • pp.137-153
    • /
    • 2007
  • Failure mode and effects analysis (FMEA) is a preventive technique in reliability management field. The successful implementation of FMEA technique can avoid or reduce the probability of system failure and achieve good product quality. The FMEA technique had applied in vest scopes which include aerospace, automatic, electronic, mechanic and service industry. The marking process is one of the back ends testing process that is the final process in semiconductor process. The marking process failure can cause bad final product quality and return although is not a primary process. So, how to improve the quality of marking process is one of important production job for semiconductor testing factory. This research firstly implements FMEA technique in laser marking process improvement on semiconductor testing factory and finds out which subsystem has priority failure risk. Secondly, a CCD position solution for priority failure risk subsystem is provided and evaluated. According analysis result, FMEA and CCD position implementation solution for laser marking process improvement can increase yield rate and reduce production cost. Implementation method of this research can provide semiconductor testing factory for reference in laser marking process improvement.

스캐닝 홀 프로브 측정 시스템의 데이터 측정 위치 표시 기술 (position marking technique for data measured in a scanning hall probe system)

  • 유재은;이재영;정예현;이상무;염도준
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권3호
    • /
    • pp.13-15
    • /
    • 2007
  • We employed home-made position marking module in the scanning Hall probe system. The module is composed of two coils of which gap, a, between wires in a coil is $500{\mu}m$. We appiled 10-35mA of current with 15Hz in the coils and recorded ac corresponding magnetic field signal with respect to measuring time while we measured DC field profiles produced due to superconducting film in a perpendicular magnetic field. We calibrate the position, x, of coils using the measuring time and location of the coils in the holder. The error range was about ${\pm}0.1mm$. We test the module as we applied current of 100A and filed of 1kG in the superconducting tape. It was confirmed that there was no interference between superconducting tape and marking coils.

SNS 연동 산삼 찾기 애플리케이션 (Wild Ginseng Searching Application through SNS)

  • 한정수;김귀정
    • 디지털융복합연구
    • /
    • 제10권2호
    • /
    • pp.237-242
    • /
    • 2012
  • This paper 산삼전문가가 아니더라도 일반인이 산삼과 같은 식물을 발견하였을 때 산삼의 진위여부를 스마트폰을 사용하여 확인할 수 있는 이미지 매칭 기술을 제안한다. 또한 SNS 기능을 추가하여 산삼을 발견한 위치 및 정보를 공유함으로써 산삼 발견의 확률을 높이고자 한다. Android에 포팅해서 사용하는 OpenCV를 이용한 이미지 매칭 기술을 사용하여 산삼 잎의 사진과 기존에 산삼으로 판명된 이미지를 비교하여 산삼의 진위여부 판별을 위한 애플리케이션을 개발함으로써 단순히 산삼의 정보표현만이 아닌 기존 실제 이미지와 비교, 분석을 통해 진위여부를 확인하였다. 더욱 정확한 검증을 위해 SNS 서비스 기능 및 Map Open API에 산삼의 위치를 마킹하는 기능을 추가하여 사용자간의 정보 공유가 가능하도록 하였다.

엘라스토머 임플란트를 사용한 엉덩이 확대 성형술 (Buttock Augmentation with Elastomer Implants)

  • 박봉권;김연환;안희창
    • Archives of Plastic Surgery
    • /
    • 제38권2호
    • /
    • pp.182-188
    • /
    • 2011
  • Purpose: The buttocks region has been associated with allure and sex appeal for centuries. Gluteal implants enable buttocks remodeling in a way that is not possible in other methods. One of the reasons that render gluteal implant surgeries unpopular is the fear of complications, the main problems being seroma, wound dehiscence, extrusion, and a visible or palpable implant. The authors present the XYZ technique, which provides anatomical reference points to guide the intramuscular dissection procedure in a feasible and safe way, resulting in a lower complication rate. Methods: The XYZ procedure was done for buttock augmentation on 8 patients from December 2009 to June 2010. Patient's ages ranged from 27 to 44 with a mean age of 36. Seven patients were applied the 250cc sized Elastomer implants with one patient 290cc sized implant. Preoperative marking was done with the patients in the standing position. Bisection of the gluteus maximus muscle was done at the midpoint thickness to create a plane for implant insertion, which is called the sandwich plane. Results: The 8 cases were performed safely without major complications. However one patient had minor wound dehiscence, and was managed with conservative treatment. Another patient had a discomfort on the buttocks for a long time. The patients were followed up for average 6 months. All patients were satisfied with the aesthetic results. Conclusion: In performing the XYZ technique for gluteal augmentation, the surgeon must split the muscle into two equal halves with anatomical reference points to guide the muscle detachment in a symmetrical way at an adequate depth. This method provides a guideline for the surgeon in determining the ideal plane during intramuscular dissection and gives predictable results with low complication rates. Intramuscular gluteoplasty with gluteal implants offers predictable, aesthetically pleasing results without contour irregularities and only a low incidence of major complications.

방사선수술을 위한 3차원 정위 시스템 및 방사선량 측정 시스템 개발 (Development of 3-D Stereotactic Localization System and Radiation Measurement for Stereotactic Radiosurgery)

  • 서태석;서덕영;박승훈;장홍석;최보영;윤세철;신경섭;박용휘;김일환;강위생;하성환;박찬일
    • Journal of Radiation Protection and Research
    • /
    • 제20권1호
    • /
    • pp.25-36
    • /
    • 1995
  • The purpose of this research is to develop stereotactic localization and radiation measurement system for the efficient and precise radiosurgery. The algorithm to obtain a 3-D stereotactic coordinates of the target has been developed using a Fisher CT or angio localization. The procedure of stereotactic localization was programmed with PC computer, and consists of three steps: (1) transferring patient images into PC; (2) marking the position of target and reference points of the localizer from the patient image; (3) computing the stereotactic 3-D coordinates of target associated with position information of localizer. Coordinate transformation was quickly done on a real time base. The difference of coordinates computed from between Angio and CT localization method was within 2 mm, which could be generally accepted for the reliability of the localization system developed. We measured dose distribution in small fields of NEC 6 MVX linear accelerator using various detector; ion chamber, film, diode. Specific quantities measured include output factor, percent depth dose (PDD), tissue maximum ratio (TMR), off-axis ratio (OAR). There was small variation of measured data according to the different kinds of detectors used. The overall trends of measured beam data were similar enough to rely on our measurement. The measurement was performed with the use of hand-made spherical water phantom and film for standard arc set-up. We obtained the dose distribution as we expected. In conclusion, PC-based 3-D stereotactic localization system was developed to determine the stereotactic coordinate of the target. A convenient technique for the small field measurement was demonstrated. Those methods will be much helpful for the stereotactic radiosurgery.

  • PDF