• Title/Summary/Keyword: portable measurement device

Search Result 98, Processing Time 0.023 seconds

The Effect of Balance Control Therapy on Brain Activation (균형조절치료가 뇌활성도에 미치는 영향)

  • Oh, Yeong-Taek;Han, Dong-Wook
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.8 no.2
    • /
    • pp.163-173
    • /
    • 2013
  • PURPOSE: This study determined the effect of balance control therapy in the brain activation. METHODS: Twenty-two college students who showed decrease of muscle strength in O-ring test were as participants in this study. And the subjects were randomly divided into experimental group (n=13) and control group (n=9). Measurement device is portable EEG (Nihonkhoden, Japan). Examinations used twenty electrodes attached to the head to capture electrical brain signals during 5 minutes with brain activated states such as the awaked state and the data were compared between the two groups. RESULTS: After treatment by balance control therapy, P3 (p<.025) and P4 areas (p<.025) showed a significantly lower ST index in the experimental group than the control group, The variation of ST index in P4 area (p<.025) was decreased in the experimental group but was increased in the control group. CONCLUSION: These results showed that the balance control therapy was helpful to change the brain activation such as the stress (ST) index at the sensory area in the college students.

Development of Realtime ECG Analysis and Monitoring System (실시간 심전도 분석 및 모니터링 시스템 개발)

  • Jeong, Gu-Young;Yoon, Myoung-Jong;Yu, Kee-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.4
    • /
    • pp.406-412
    • /
    • 2009
  • ECG is used on purpose to keep good health or monitor cardiac function of aged person as well as on purpose to diagnose the disease of heart patients. The ambulatory ECG monitoring system under guarantee of safety and accuracy is very efficient to prevent the progress of heart disease and sudden death. These systems can detect the temporary change of ECG that is very significant to diagnose heart disease such as myocardial ischemia, arrhyamia and cardiac infarction. In this paper, we describe the ECG signal analysis algorithm and measurement device for ECG monitoring. The authors designed a small-size portable ECG device that consisted of instrumentation amplifier, micro-controller, filter and RF module. The device measures ECG with four electrodes on the body and detects QRS complex and ST level change in realtime. Also it transmits the measured signals to the personal computer. The developed software for ECG analysis in personal computer has the function to detect the feature points and ST level changes.

Throughput Analysis in Vehicular Wi-Fi Networks (Wi-Fi 기반 차량 네트워크에서의 인터넷 처리율 분석)

  • Kim, Won-Jung;Kim, Young-Hyun;Youn, Joo-Sang;Pack, Sang-Heon
    • The KIPS Transactions:PartC
    • /
    • v.18C no.1
    • /
    • pp.45-50
    • /
    • 2011
  • Due to advances in wireless communications and portable terminals, any-time, any-where, and any-device Internet access is possible. In particular, Internet access in moving vehicles is an emerging and challenging issue. Even though a variety studies have been conduced for vehicular networks, little attention is paid to vehicular Wi-Fi networks where a Wi-Fi access point (AP) is installed at the vehicle and the AP is connected to an external base station (BS). In this paper, we conduct a measurement study on the uplink and downlink throughput for Internet access in vehicular Wi-Fi networks. We consider diverse network environments: high-speed train, car, and subway. Measurement results demonstrate that current Internet access in vehicular Wi-Fi networks are not satisfactory for interactive multimedia applications. Therefore, in-depth study on resource management in vehicular Wi-Fi networks is strongly required.

Diagnosis of Medium Voltage Cables for Nuclear Power Plant

  • Ha, Che-Wung;Lee, Do Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1369-1374
    • /
    • 2014
  • Most accidents of medium-voltage cables installed in nuclear power plants result from the initial defect of internal insulators or the initial failure due to poor construction. However, as the service years of plants increase, the possibility of cable accidents is also rapidly increases. This is primarily caused by electric, mechanical, thermal, and radiation stresses. Recently, much attention is paid to the study of cable diagnoses. To date, partial discharge and Tan${\delta}$ measurements are known as reliable methods to diagnose the aging of medium-voltage cables. High frequency partial discharge measurement techniques have been widely used to diagnose cables in transmission and distribution systems. However, the on-line high frequency partial discharge technique has not been used in the nuclear power plants because of the plant shutdown risk, degraded measurement sensitivity, and application problems. In this paper, the partial discharge measurement with a portable device was tried to evaluate the integrity of the 4.16kV and 13.8kV cable lines. The test results show that the high detection sensitivity can be achieved by the high frequency partial discharge technique. The present technique is highly attractive to diagnose medium voltage cables in nuclear power plants.

Optical-fiber Electronic Speckle Pattern Interferometry for Quantitative Measurement of Defects on Aluminum Liners in Composite Pressure Vessels

  • Kim, Seong Jong;Kang, Young June;Choi, Nak-Jung
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.50-56
    • /
    • 2013
  • Optical-fiber electronic speckle pattern interferometry (ESPI) is a non-contact, non-destructive examination technique with the advantages of rapid measurement, high accuracy, and full-field measurement. The optical-fiber ESPI system used in this study was compact and portable with the advantages of easy set-up and signal acquisition. By suitably configuring the optical-fiber ESPI system, producing an image signal in a charge-coupled device camera, and periodically modulating beam phases, we obtained phase information from the speckle pattern using a four-step phase shifting algorithm. Moreover, we compared the actual defect size with that of interference fringes which appeared on a screen after calculating the pixel value according to the distance between the object and the CCD camera. Conventional methods of measuring defects are time-consuming and resource-intensive because the estimated values are relative. However, our simple method could quantitatively estimate the defect length by carrying out numerical analysis for obtaining values on the X-axis in a line profile. The results showed reliable values for average error rates and a decrease in the error rate with increasing defect length or pressure.

Production of Spirometer 'The Spirokit' and Performance Verification through ATS 24/26 Waveform (휴대형 폐기능 검사기 'The Spirokit'의 제작 및 ATS 24/26파형을 통한 성능검증)

  • Byeong-Soo Kim;Jun-Young Song;Myung-Mo Lee
    • Journal of Korean Physical Therapy Science
    • /
    • v.30 no.3
    • /
    • pp.49-58
    • /
    • 2023
  • Background: This study aims to examine the useful- ness of the portable spirometer "The Spirokit" as a clinical diagnostic device through technology introduction, precision test, and correction. Design: Technical note Methods: "The Spirokit" was developed using a propeller-type flow rate and flow rate measurement method using infrared and light detection sensors. The level of agreement between the Pulmonary Waveform Generator and the measured values was checked to determine the precision of "The Spirokit", and the correction equation was included using the Pulmonary Waveform Generator software to correct the error range. The analysis was requested using the ATS 24/26 waveform recognized by the Ministry of Food and Drug Safety and the American Thoracic Society for the values of Forced Voluntary Capacity (FVC), Forced Expiratory Volume in 1second (FEV1), and Peak Expiratory Flow (PEF), which are used as major indicators for pulmonary function tests. All tests were repeated five times to derive an average value, and FVC and FEV1 presented accuracy and PEF presented accuracy as the result values. Results: FVC and FEV1 of 'The Spirokit' developed in this study showed accuracy within ± 3% of the error level in the ATS 24 waveform. The PEF value of 'The Spirokit' showed accuracy within the error level ± 12% of the ATS 26 waveform. Conclusion: Through the results of this study, the precision of 'The Spirokit' as a clinical diagnosis device was identified, and it was confirmed that it can be used as a portable pulmonary function test that can replace a spirometer.

A Window-Based DVS Algorithm for MPEG Player (MPEG 동영상 재생기를 위한 윈도우 기반 동적 전압조절 알고리즘)

  • Seo, Young-Sun;Park, Kyung-Hwan;Baek, Yong-Gyu;Cho, Jin-Sung
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.35 no.11
    • /
    • pp.517-526
    • /
    • 2008
  • As the functionality of portable devices arc being enhanced and the performance is being greatly improved, power dissipations of battery driven portable devices are being increased. So, an efficient power management for reducing their power consumption is needed. In this paper, we propose a window-based DVS algorithm for MPEG Player. The proposed algorithm maintains the recently frame information and execution time received from MPEG player in window queue and dynamically adjusts (frequency, voltage) level based on window queue information. Our algorithm can be implemented in the common multimedia player as a module. We employed well-known MPlayer for the measurement of performance. The experimental result shows that the proposed algorithm reduces energy consumption by 56% on maximal performance.

A Compact Tunable VCSEL and a Built-in Wavelength Meter for a Portable Optical Resonant Reflection Biosensor Reader

  • Ko, Hyun-Sung;Kim, Bong-Kyu;Kim, Kyung-Hyun;Huh, Chul;Kim, Wan-Joong;Hong, Jong-Cheol;Park, Seon-Hee;Yang, Seong-Seok;Jang, Ho-Jin;Sung, Gun-Yong
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.395-402
    • /
    • 2010
  • This study reports a portable and precision photonic biosensor reader that can measure the concentration of a particular antigen using an optical resonant reflection biosensor (ORRB). To create a compact biosensor reader, a compact tunable vertical-cavity surface-emitting laser (VCSEL) and a compact built-in wavelength meter were manufactured. The wavelength stability and accuracy of the compact built-in wavelength meter were measured to be less than 0.02 nm and 0.06 nm, respectively. The tunable VCSEL emission wavelength was measured with the compact built-in wavelength meter, it has a fast sweep time (~ 10 seconds) and a wide tuning range (> 4 nm) that are sufficient for biosensor applications based on ORRB. The reflection spectrum of a plastic based ORRB chip was measured by the fabricated portable photonic biosensor reader using the VCSEL and wavelength meter. Although the reader is the size of a palmtop device, it could make a precise measurement of the peak wavelength on equal terms with a conventional bulky optical spectrometer.

Linear Tapered Slot Rectifying Antenna for Portable UHF-Band RFID System (휴대용 UHF대역 RFID 시스템을 위한 선형 테이퍼드 슬롯 정류 안테나)

  • Pyo, Seongmin
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.368-371
    • /
    • 2020
  • In this paper, we propose a linear tapered slot rectifying antenna for a portable UHF-band RFID system. Since the proposed rectifying antenna does not use a dielectric substrate, the planar antenna is implemented with a thin metal thickness. The rectifier circuit converts input RF power into output DC voltage using a voltage doubler circuit based on two anti-parallel schottky diodes. The rectifying antenna is integrated by the voltage doubler circuit into a linear tapered slot antenna. For conjugate impedance matching of the rectifying circuit and the linear tapered slot antenna, the source-pull method was utilized by adjusting the angle of the tapered slot and the length of the antenna feed line. The proposed antenna prototype has been verified with the electrical and radiation characteristics through RF-DC conversion and far-field radiation test in open space measurement environment. Finally, the proposed antenna is realized to 0.23-wavelength (75 mm) and 0.18-wavelength (60 mm) at 915 MHz center frequency.

A Study on Smart Accuracy Control System based on Augmented Reality and Portable Measurement Device for Shipbuilding (조선소 블록 정도관리를 위한 경량화 측정 장비 및 증강현실 기반의 스마트 정도관리 시스템 개발)

  • Nam, Byeong-Wook;Lee, Kyung-Ho;Lee, Won-Hyuk;Lee, Jae-Duck;Hwang, Ho-Jin
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.1
    • /
    • pp.65-73
    • /
    • 2019
  • In order to increase the production efficiency of the ship and shorten the production cycle, it is important to evaluate the accuracy of the ship components efficiently during the drying cycle. The accuracy control of the block is important for shortening the ship process, reducing the cost, and improving the accuracy of the ship. Some systems have been developed and used mainly in large shipyards, but in some cases, they are measured and managed using conventional measuring instruments such as tape measure and beam, optical instruments as optical equipment, In order to perform accuracy control, these tools and equipment as well as equipment for recording measurement data and paper drawings for measuring the measurement position are inevitably combined. The measured results are managed by the accuracy control system through manual input or recording device. In this case, the measurement result is influenced by the work environment and the skill level of the worker. Also, in the measurement result management side, there are a human error about the lack of the measurement result creation, the lack of the management sheet management, And costs are lost in terms of efficiency due to consumption. The purpose of this study is to improve the working environment in the existing accuracy management process by using the augmented reality technology to visualize the measurement information on the actual block and to obtain the measurement information And a smart management system based on augmented reality that can effectively manage the accuracy management data through interworking with measurement equipment. We confirmed the applicability of the proposed system to the accuracy control through the prototype implementation.