• Title/Summary/Keyword: pore analysis

Search Result 1,250, Processing Time 0.027 seconds

Taxonomic Study of the Genus Pholiota (Strophariaceae, Basidiomycota) in Korea

  • Lee, Jun Won;Park, Myung Soo;Park, Ji-Hyun;Cho, Yoonhee;Kim, Changmu;Kim, Chang Sun;Jo, Jong Won;Lim, Young Woon
    • Mycobiology
    • /
    • v.48 no.6
    • /
    • pp.476-483
    • /
    • 2020
  • The genus Pholiota (Strophariaceae, Basidiomycota) is made up of wood-rotting saprotrophic mushrooms characterized by a yellow or brown pileus with scales and/or slimy, and by a brownish smooth spore with a germ pore. However, these features are not enough to distinguish its species, or separate the genus Pholiota from other brown-spored wood-rotting genera such as Hypholoma and Stropharia. Although internal transcribed spacer (ITS) sequencebased identification has improved identification accuracy for species of Pholiota, most Pholiota species in Korea are reported based on morphological features. To evaluate the taxonomy of Pholiota species, we investigated 62 specimens collected from 1999 to 2019 in Korea using ITS sequence analysis and morphological observation. Twelve of the 16 recorded Pholiota species in Korea were identified. While eight species were clearly separated, the ITS analysis did not distinguish three in the Pholiota adiposa complex. Therefore, further investigation is required to distinguish these three species. ITS sequences deposited in GenBank confirm that P. highlandensis exists in Korea. The presence of the other four Pholiota species could not be confirmed through specimens or sequence information in GenBank. A taxonomic key and the ITS sequence data for Korean Pholiota species are included and can be good baselines for further research on Pholiota taxonomy and diversity.

The Analysis of Single Piles in Weathered Soil with and without Ground Water Table under the Dynamic Condition (지진 시 풍화지반(건조/포화)에 근입된 단말뚝의 동적거동 분석)

  • Song, Su-Min;Park, Jong-Jeon;Jeong, Sang-Seom
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.1
    • /
    • pp.17-33
    • /
    • 2022
  • This study describes the effect of ground water table on the dynamic analysis of single piles subjected to earthquake loading. The dynamic numerical analysis was performed for different dry and saturated soils with varying the relative densities of surrounding weathered soils (SM). The test soil was a weathered soil encountered in the engineering field and bender element tests were conducted to estimate the dynamic properties of test soil. The Mohr-Coulomb model and Finn model were used for soil, dry and saturated conditions, respectively. These models validated with results of centrifuge tests. When compared with the results from the soil conditions, saturated cases showed more lateral displacement and bending moment of piles than dry cases, and this difference caused from the generation of excess porewater pressure. It means that the kinematic effect of the soil decreased as the excess pore water pressure was generated, and it was changed to the inertial behavior of the pile.

Performance Evaluation of OGS-FLAC Simulator for Coupled Thermal-Hydrological-Mechanical Analysis (열-수리-역학적 연계해석을 위한 OGS-FLAC 시뮬레이터의 성능 평가)

  • Park, Dohyun;Park, Chan-Hee
    • Tunnel and Underground Space
    • /
    • v.32 no.2
    • /
    • pp.144-159
    • /
    • 2022
  • The present study developed a sequential approach-based numerical simulator for modeling coupled thermal-hydrological-mechanical (THM) processes in the ground and investigated the computational performance of the coupling analysis algorithm. The present sequential approach linked the two different solvers: an open-source numerical code, OpenGeoSys for solving the thermal and hydrological processes in porous media and a commercial code, FLAC3D for solving the geomechanical response of the ground. A benchmark test of the developed simulator was carried out using a THM problem where an analytical solution is given. The benchmark problem involves the coupled behavior (variations in temperature, pore pressure, stress, and deformation with time) of a fully saturated porous medium which is subject to a point heat source. The results of the analytical solution and numerical simulation were compared and the validity of the numerical simulator was investigated.

Investigation on Water Leakage-Induced Tunnel Structure and Ground Responses Using Coupled Hydro-Mechanical Analysis (수리역학 연계해석을 이용한 누수로 인한 터널 구조물 및 지반 거동의 분석)

  • Dohyun Park
    • Tunnel and Underground Space
    • /
    • v.33 no.4
    • /
    • pp.265-280
    • /
    • 2023
  • Water leakage in tunnels is a defect that can affect tunnel stability and the ground movement by changing the stress and pore water pressure of the surrounding ground. Long-term or large-scale water leaks may lead to damage of tunnel structure and the surrounding environment, such as tunnel lining instability and ground surface settlement. The present study numerically investigated the effects of water leakage on the structural stability of a tunnel and the ground behavior. The tunnel was assumed to be under undrained conditions for preventing the inflow of the surrounding water and leaks occurred in the concrete lining after completion of the tunnel construction. A coupled hydro-mechanical analysis using a TOUGH-FLAC simulator developed in Python was conducted for assessing the leakage induced-behavior of the tunnel structure and ground under different conditions of the amount and location of water leak. Additionally, the effect of hydro-mechanical coupling terms on the results of coupled response was investigated and discussed.

Stochastic Seepage Analysis of Dam (확률론적 댐 침투거동 해석)

  • Cho Sung-Eun
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.4
    • /
    • pp.73-83
    • /
    • 2006
  • Seepage analysis through unsaturated zone based on the theory of unsaturated flow is commonly performed to evaluate dam safety. However, the concepts of unsaturated soil behavior have not been transferred into the hands of practicing geotechnical engineers since the problems involving unsaturated soils often have the appearances of being extremely complex. There is variability and uncertainty associated with the unsaturated hydraulic properties that in turn will lead to variability in predicting unsaturated soil behavior such as seepage rate and the pore water pressure distribution. In this paper, measurements of the soil-water characteristic curve and saturated hydraulic conductivity for the core material of dam were conducted. Then, finite element stochastic analysis was used to capture the effect of unsaturated hydraulic properties on the seepage behavior of dam. It is observed that the amount of seepage increases, as the values of unsaturated soil parameters a and n increase. The values of m and p showed opposite trend.

Determination of OCR on the Deltaic Clay of the Nakdong River (낙동강 삼각주 점토에 대한 과압밀비의 평가)

  • 정성교;김규종;이대명;조기영
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.4
    • /
    • pp.85-97
    • /
    • 1999
  • For a deltaic clay in the mouth of the Nakdong river, OCR was investigated through methods using the results of field measurement, laboratory and field soil tests. As a result, OCRs were obtained around the range of 0.95 to 1.20 by analysis of field measurements, although they were estimated around the values of 0.4 to 0.7 by the results of conventional consolidation tests for the clay. From the dissipation test it was found out that the excess pore pressures scarcely existed in the clay deposit and then the soil was not in the underconsolidated condition. And the OCRs obtained through methods of Mayne(1991) and Cao et al(1996) using the piezocone test and of Mayne & Kemper(1988) using the cone penetration test were in good agreement with those of field measurement.

  • PDF

Biofilter pretreatment for the control of microfiltration membrane fouling

  • Park, Jae-Hyung;Satoshi Takizawa;Hiroyuki Katayama;Shinichiro Ohgaki
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2003.05a
    • /
    • pp.31-38
    • /
    • 2003
  • A pilot scale biofilter pretreatment-microfiltration system (BF-MF) was operated to investigate the effect of biofilter treatment in fouling reduction of microfiltration. Biofiltration was expected to reduce the membrane fouling by removal of turbidity and metal oxides. The hollow-fiber MF module with a nominal pore size of 0.1$\mu$m and a surface area of 8m$^2$ was submerged in a filtration tank and microfiltration was operated at a constant flux of 0.5 m/d. Biofiltration using polypropylene pellets was performed at a high filtration velocity of 320 m/d. Two experimental setups composed of MF and BF/MF, i.e., without and with biofilter pretreatment, were compared. Throughout the experimental period of 9 months, biofilter pretreatment was effective to reduce the membrane fouling, which was proved by the result of time variations of trans-membrane pressure and backwash conditions. The turbidity removal rate by biofiltration varied between 40% to 80% due to the periodic washing for biofilter contactor and raw water turbidity. In addition to turbidity, metals, especially Mn, Fe and Al were removed effectively with average removal rates of 89.2%, 67.8% and 64.9%, respectively. Further analysis of foulants on the used membranes revealed that turbidity and metal removal by biofiltration was the major effect of biofiltration pretreatment against microfiltration fouling.

  • PDF

Heat and mass transfer analysis in air gap membrane distillation process for desalination

  • Pangarkar, Bhausaheb L.;Sane, Mukund G.
    • Membrane and Water Treatment
    • /
    • v.2 no.3
    • /
    • pp.159-173
    • /
    • 2011
  • The air gap membrane distillation (AGMD) process was applied for water desalination. The main objective of the present work was to study the heat and mass transfer mechanism of the process. The experiments were performed on a flat sheet module using aqueous NaCl solutions as a feed. The membrane employed was hydrophobic PTFE of pore size 0.22 ${\mu}m$. A mathematical model is proposed to evaluate the membrane mass transfer coefficient, thermal boundary layers' heat transfer coefficients, membrane / liquid interface temperatures and the temperature polarization coefficients. The mass transfer model was validated by the experimentally and fitted well with the combined Knudsen and molecular diffusion mechanism. The mass transfer coefficient increased with an increase in feed bulk temperature. The experimental parameters such as, feed temperature, 313 to 333 K, feed velocity, 0.8 to 1.8 m/s (turbulent flow region) were analyzed. The permeation fluxes increased with feed temperature and velocity. The effect of feed bulk temperature on the boundary layers' heat transfer coefficients was shown and fairly discussed. The temperature polarization coefficient increased with feed velocity and decreased with temperature. The values obtained were 0.56 to 0.82, indicating the effective heat transfer of the system. The fouling was observed during the 90 h experimental run in the application of natural ground water and seawater. The time dependent fouling resistance can be added in the total transport resistance.

Experimental Study on Carbon Corrosion of Gas Diffusion Layer in PEM Fuel Cell (고분자전해질형 연료전지 가스확산층의 탄소 부식에 관한 실험적 분석)

  • Ha, Taehun;Cho, Junhyun;Park, Jaeman;Min, Kyoungdoug;Lee, Eunsook;Jyoung, Jy-Young
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.76.1-76.1
    • /
    • 2010
  • Recently, many efforts to solve the durability problem of PEM fuel cell are carried on constantly. However, despite this attention, durability researches of gas diffusion layer (GDL) are not much reported yet. Generally, GDL of PEM fuel cell experiences three external attacks, which are dissolution of water, erosion of gas flow, corrosion of electric potential. In this study, among these degradation factors, carbon corrosion of electric potential was focused and investigated with accelerated carbon corrosion test. Through the test, it is confirmed that carbon corrosion occurred at GDL, and corroded GDL decreased a performance of operating fuel cell. The property changes of GDL were measured with various methods such as air permeability meter, pore distribution analyzer, thermo gravimetric analyzer, and tensile stress test to discover the effects of carbon corrosion. Carbon corrosion caused not only loss of weight and thickness, but also degradation of mechanical strength of GDL. In addition, to analysis the reason of GDL property changes, a surface and a cross section of GDL were observed with scanning electron microscope. After 100 hours test, the GDL showed serious damage in center of layer.

  • PDF

Preparation of Silica Nanoparticles via Two-Step Process Utilizing Mixed Chlorosilane Residues

  • Su, Yonghong;Xu, Bugang;Cai, Jixiang;Chen, Liang;Huang, Bing
    • Journal of the Korean Ceramic Society
    • /
    • v.55 no.6
    • /
    • pp.562-569
    • /
    • 2018
  • We propose an economic and facile method for the preparation of silica nanoparticles through a two-step process utilizing chlorosilane residues. Mixed chlorosilane residue was alcoholized with absolute ethanol as a first step to form tetraethoxysilane (TEOS). The TEOS was then utilized as a silicon source to synthesize silica nanoparticles in a sol-gel method. The alcoholysis process was designed and optimized utilizing the Taguchi experimental design method and the yield of TEOS was as high as 82.2% under optimal synthetic conditions. Similarly, the Taguchi method was also utilized to study the effects of synthesis factors on the particle size of silica nanoparticles. The results of statistical analysis indicate that the concentration of ammonia has a greater influence on particle size compared to the mass fractions of TEOS and polyethylene glycol (4.6% and 9.7%). The purity of the silica particles synthesized in our experiments is high, but the specific surface area and pore volume are small.