• Title/Summary/Keyword: poor connection

Search Result 139, Processing Time 0.027 seconds

Deformation Capacity of Steel Moment Connections with RHS Column (각형강관 기둥을 가진 철골모멘트 접합부의 변형능력)

  • Kim, Young-Ju;Oh, Sang-Hoon;Ryu, Hong-Sik
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.249-258
    • /
    • 2006
  • In this paper, deformation capacity of steel moment connections with RHS column was investigated. Initially, non-linear finite element analysis of five bate steel beam models was conducted. The models were designed to have different detail at their beam-to-column connection, so that the flexural moment capacity was different respectively. Analysis results showed 4hat the moment transfer efficiency of the analytical model with RHS-column was poor when comparing to model with WF(Wide flnage)-column due to out-of-plane deformation of the RHS-column flange. The presence of scallop and thin plate of RHS column was also a reason of the decrease of moment transfer efficiency, which would result in a potential fracture of tile steel beam-to-column connections. Further test on beam-to-column connections with RHS column revealed that the moment transfer efficiency of a beam web decreased due to the out-of-plane deformation of column flange, which led to premature failure of the connection.

  • PDF

Quality of Life of Older Adult with Home Health Services - Applied PRECEDE Model - (취약계층 노인의 삶의 질에 영향을 미치는 요인 - PRECEDE 모형 적용 -)

  • Park, Kum-Hwa;Choi, Yeon-Hee
    • The Korean Journal of Rehabilitation Nursing
    • /
    • v.13 no.1
    • /
    • pp.32-43
    • /
    • 2010
  • Purpose: The purpose of this study was to determine factors that affect poor quality of life (QOL) of older adults who received home health service. Method: The sample 492 older adults participated in the study. The QOL was measured using the scale of QOL of Ware and other data were collected through face-to-face interviews from September to August, 2009. Results: The level of QOL was moderate (Mean 24.4, SD 7.4). The QOL was poorer in older adults (p<.05) and in those living alone (p<.01) compared to older adults and those living with couple or family respectively. The QOL was positively correlated with a sense of mastery (r=.213, p<.05), connection of health (r=.160, p<.05) and a cognitive function (r=.119, p<.01), and negatively correlated with Activities of Daily Living (r=-.266, p<.01) and Instrumental Activities of Daily Living (r=-.339, p<.01). Sense of mastery, connection of health & welfare, and IADL were significant predictors of QOL. Conclusion: Finding suggest that home health service program should incorporate strategies for increasing sense of mastery and capability of performing IADL, and strengthening connection of health service that may improve QOL of older home health service recipients.

Experimental Study on Seismic Performance Enhancement of Exposed Column-base Plate Strong-axis Connections for Small-Sized Steel Buildings (소규모 철골조건축물 강축방향 노출형 주각부의 내진성능 향상을 위한 실험 연구)

  • You, Young-Chan
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.12
    • /
    • pp.11-20
    • /
    • 2018
  • The purpose of this study is to investigate the seismic performance of exposed column-base plate strong-axis connections for small-sized steel buildings. Even though the seismic design for small-sized buildings became mandatory since Dec.2017, the arbitrary connection details in steel structure have been applied at the construction site, which is considered to be very insufficient to secure structural safety and stability considering the increased seismic risk. Therefore, a series of experimental test programs had been carried out to develop enhanced connection details in order to ensue the adequate seismic safety of small buildings. The hysteretic behavior of the exposed column-base plate connections commonly used in Korea seem to be very pure poor due to the "Rocking" phenomena between anchor plate and concrete by the residual plastic deformation of anchor bolts. A series of hysteretic tests were conducted to find the solution to overcome the "Rocking" phenomena of the exposed column-base plate connections, finally the stable seismic behavior was obtained by uisng at least 8 anchor bolts with good bonding strength to the protptype specimen.

Study on the Yo Bae Byoung Hoo of the Je Bung Won Hu Ron (제병원후론ㆍ요배병제후에 대한 연구)

  • An Min Sik;Jeong Heon Young
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.17 no.3
    • /
    • pp.624-628
    • /
    • 2003
  • JebyeongwonhuronㆍYobaebyeonjehu is well organized and detailed is stated of classification and cause, mechanism of lumbago. That is divided into nine classes according to cause and symptoms of lumbago and described those respectively. Although there is some different, classification of lumbago after ages is based on this method in the main. The outbreak mechanism of lumbago can be stated that wicked germ invade into the body in condition that spirit and energy, especially the kidney energy is poor through various reason. That is stressed on interior factors. In the relation to organs, it is inferred that outbreak of lumbago have connection with the kidney deeply.

The Analysis of Deterioration Characteristics by Poor Contact at the Connection Part of Power Cord (전원코드 접속부에서의 접촉불량에 의한 열화특성 분석)

  • Kim, Hyang-Kon;Lee, Ki-Yoen;Moon, Hyun-Wook;Kim, Hyeog-Soo;Kim, Myung-Soo;Kim, Man-Geon
    • Congress of the korean instutite of fire investigation
    • /
    • 2010.06a
    • /
    • pp.66-81
    • /
    • 2010
  • In this study, we experimented and analyzed deterioration characteristics of outlets and power cord sets caused by poor contact. Electrical waveforms were measured according to load size and elapsed time. After that, surface structure and deteriorated characteristics of conductive materials and insulators were analyzed. We hope that the results will be applicable to electrical fire prevention and accidents analysis.

  • PDF

Study on Multi Parameter Measurement and Analysis of Distribution High Voltage Cable Connection Part (배전용 특고압 케이블 접속재의 다변수 측정 분석 연구)

  • Song, Ki-Hong;Bae, Young-Chul;Kim, Yi-Gon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.1
    • /
    • pp.53-60
    • /
    • 2021
  • High voltage CV cables have been widely installed underground due to their convenience and urban aesthetics. However, cable accidents have occurred frequently owing to poor construction and natural degradations. This paper proposes the method to measure the multi parameter measurement for optimum diagnostics of high voltage cable connection parts and verifies its technical usefulness. This measurement is intended to diagnose degradations of cable connection parts by using simultaneous vibration and thermography as well as partial discharge(PD). The experiment in a shielded laboratory was carried out to verify the usefulness of the multi parameter measurement. The experiment defined the degradation of the cable connection part as 12 types, and produced each degradation sample. As a result of experiment, it was possible to check the correlation of vibration signals with regard to progress in some defects. In the case of thermography, the coherence with regard to the progress of some defects was found. We figure that the proposed method would be useful also in the noise environment.

Fire Mechanism in Power Connection Points of Outlets and Suggestion of a New Identification Method (콘센트 전원 접속구 화재 발생 메커니즘 고찰과 새로운 감식 방법 제시)

  • Park, Jin-Young;Bang, Sun-Bae;Eun, Hee-Rim;Oh, Se-Hyeok;Lee, Yoo-Bin;Ko, Young-Ho
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.76-84
    • /
    • 2020
  • Most outlet fires occur around plug pins and plug pin receivers. However, no research has been conducted on ignitions at power connection points. This study confirms the possibility of ignition after incomplete connection, using a stranded wire, to the power connection point of an outlet. The experiment was divided into basic and reproducing experiments. The basic experiment confirmed the possibility of ignition according to the number of wire strands connected to the power connection point, and it identified the characteristics of the residue after the fire. In the reproducing experiment, lamps, vacuum cleaners, and heaters were connected to an outlet to check if the ignition at the connection advanced into a fire. The fire advanced due to the heat and arc generated at the connection point, and partial losses were identified in the U-type holder and clip. Accordingly, the results demonstrate that a fire may occur when the stranded wire is incompletely connected to the outlet. Moreover, it was confirmed that the cause of a fire can be determined based on the characteristics of the residue.

Fire Cause Analysis on Electric Pad Due to Defect of Hot Wires (전기장판 열선 결함에 의한 전기화재 원인분석)

  • Song, J.Y.;Sa, S.H.;Nam, J.W.;Kim, J.P.;Cho, Y.J.;Oh, B.Y.
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.2
    • /
    • pp.7-12
    • /
    • 2012
  • This paper describes electrical fire on electric pad caused by defect of hot wires. We analyzed two type electric pad using by carbon type hot wire and magnetic shielded type hot wire. First, a carbon type hot wires electric pad is virtually impossible to connect hot wire as a method of electrical welding or soldering. In order to connect between hot wires, that has to splice carbon type material connector. If junction of hot wires was occurrence of poor connection on electric pad, it increase contact resistance on this junction point. With increasing contact resistance, junction of hot wires on electric pad generates local heating and finally leads to electrical fire. An electric pad using by a magnetic shielded type hot wire happened local heating on signal wire for sensing temperature-rise caused by applying current for magnetic shielded. With increasing local heating of signal wire, insulated coating of hot wire was melted. Finally the magnetic shielded type hot wire electric pad lead to electrical fire with breakdown between signal wire and hot wire. In this paper, we analyzed shape of damage in hot wire caused by electrical local heating and investigated fire cause on electric pad due to defect of hot wires.

Adolescent' Internet Utilization Status of Dietary Information in Kyungnam (경남일부 청소년의 인터넷 식생활 정보이용에 관한 연구)

  • 이경혜;강현진;허은실
    • Journal of Nutrition and Health
    • /
    • v.35 no.1
    • /
    • pp.115-123
    • /
    • 2002
  • This study was carried out to investigate the utilization status of internet dietary information by gender(boys: 363, girls: 366) in adolescent(middle & high school students). The results were summarized as follows. The internet using frequency of 6-7times per week had 45.0% of subjects and the using time of internet per a time was shown mainly'<2hours(68.5%)'. The main place for internet use was home(79.0%) and favorite search engine was 'Yahoo'(45.7%) and 'Daum'(19.3%). As main purpose using internet were mentioned 'social intercourse'(45.0%) and data search'(24.8%). The organization that offer to reliable internet information was educational institution'(49.4%). The problems in using information site were 'poor information'(26.4%), 'slow connection speed'(22.6%), and 'don't arouse interest'(18.8%). The search experience about dietary information had only 27.9% of subjects and search purpose was 'for homework'(33.3%) and 'for health'(32.0). The satisfaction degree of dietary information was not high. The connection motive to dietary information was mainly 'by site navigation casualty'(55.7%). Only 7.7% of subjects had experience of nutrition counseling using internet, and the motive of nutrition counseling was also 'by site navigation causally'(55.8%). The purpose of counseling was 'for diet'(41.5%) and 'for health problem'(30.2%), and the satisfaction degree of counseling result was very low. As the ask of improvement for counseling site were pointed out 'poor in answer content'(44.8%) and 'lazy answer'(31.0%). The subjects wanted to get the dietary information about 'growth in status'(41.4%), 'diet related skin beauty'(14.6%), the update period less 1 month, and the way of 'free board'(32.3%), 'game'(21.1%) and 'animation'(19.3%) as offer tool. The results of this study showed that although the internet using percent and frequency of subjects was high, they used dietary information very seldom and they are dissatisfied with internet nutritional information. Therefore, the information donor should consider which dietary information was needed and what is the optimal tool for adolescent.

TAS: TCP-Aware Sub-layer over IEEE 802.11-based wireless LANs (IEEE 802.11 기반 무선랜에서 TCP 인진서브 계층 TAS)

  • Choi, Nak-Jung;Jung, Ha-Kyung;Ryu, Ji-Ho;Seok, Yong-Ho;Choi, Yang-Hee;Kwon, Tae-Kyoung
    • Journal of KIISE:Information Networking
    • /
    • v.33 no.5
    • /
    • pp.355-368
    • /
    • 2006
  • This paper introduces a new split-TCP approach for improving TCP performance over IEEE 802.11-based wireless LANs. TCP over wireless LANs differently from wired networks is not aggressive, which is a fundamental reason for poor performance. Therefore, we propose TAS (TCP-Aware Sub-layer) to migigate this problem. Our scheme extends the split-connection approach that divides a connection into two different connections at a split point such as an access point (AP). Using TAS, a wireless node emulates TCP ACK packets using MAC ACK frames, instead of receiving real TCP ACK packets. We compared TAS with both normal TCP and I-TCP (Indirect TCP) by NS2 simulation. Results show that TAS achieves higher throughput, more fair resource allocation and, in power-saving mode, shorter delays.