• 제목/요약/키워드: polyvinyl siloxane

검색결과 21건 처리시간 0.021초

DENTIN BONDING AGENTS들의 상아세관 밀봉 효과에 관한 연구 (STUDY ON DENTINAL TUBULES SEALING EFFECTS OF DENTIN BONDING AGENTS)

  • 권오택;박동수
    • Restorative Dentistry and Endodontics
    • /
    • 제18권2호
    • /
    • pp.483-496
    • /
    • 1993
  • Dentin hypersensitivity medicaments such as Gluma, Scotchbond 2, All-Bond 2, which are resin adhesives, were used to compare the sealing effects of dentinal tubule under mechanical stress. Topical application of above medicaments on the dentin surfaces of extracted teeth followed by artificial tooth brushing for 6 weeks was performed for the comparison. The following conclusions on the degree of dentinal tubule exposure versus time by were reached by using polyvinyl siloxane impression material for taking the impression, epoxy resin for the duplication and SEM for observing the surface. 1. SEM was used to compare the accuracy of the duplicated surface, but no differences were found when teeth samples and the duplicated surfaces were observed. 2. After comparing the degree of dentinal tubules exposure with varnish applied contrast group, resin adhesive materials showed much less exposure as time went by. 3. The results indicated that AU-Bond 2 adhesive, under mechanical stress, showed lesser exposure of dentinal tubules comparing with Gluma and Scotchbond 2 adhesives After the results were put together, it was demonstrated that resin replica method is an useful way to evaluate the treatment effects of the dentinal tubule hypersensitivity medicaments. Also, it was noticed that under mechanical stress, All-Bond 2, classified as fourth generation, illustrated the best dentinal tubules sealing effects.

  • PDF

Accuracy of casts produced from conventional and digital workflows: A qualitative and quantitative analyses

  • Abduo, Jaafar
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권2호
    • /
    • pp.138-146
    • /
    • 2019
  • PURPOSE. Comparing the accuracy of casts produced from digital workflow to that of casts produced from conventional techniques. MATERIALS AND METHODS. Whole arch alginate (ALG) and polyvinyl siloxane (PVS) impressions were taken with stock trays and custom trays, respectively. The ALG impressions were poured with type III dental stone, while the PVS impressions were poured with type IV dental stone. For the digital workflow, IOS impressions were taken and physical casts were produced by 3D printing. In addition, 3D printed casts were produced from images obtained from a laboratory scanner (LS). For each technique, a total of 10 casts were produced. The accuracies of the whole arch and separated teeth were virtually quantified. RESULTS. Whole arch cast accuracy was more superior for PVS followed by LS, ALG, and IOS. The PVS and ALG groups were inferior in the areas more susceptible to impression material distortion, such as fossae and undercut regions. The LS casts appeared to have generalized errors of minor magnitude influencing primarily the posterior teeth. The IOS casts were considerably more affected at the posterior region. On the contrary, the IOS and LS casts were more superior for single tooth accuracy followed by PVS and ALG. CONCLUSION. For whole arch accuracy, casts produced from IOS were inferior to those produced from PVS and ALG. The inferior outcome of IOS appears to be related to the span of scanning. For single tooth accuracy, IOS showed superior accuracy compared to conventional impressions.

탄성고무인상재에 따른 초경석고 모형의 정밀도에 관한 연구 (ACCURACY OF IMPROVED STONE CASTS FROM ELASTOMERIC IMPRESSION MATERIALS)

  • 김기홍;장익태;임순호
    • 대한치과보철학회지
    • /
    • 제37권3호
    • /
    • pp.301-312
    • /
    • 1999
  • The purpose of this study was to compare the accuracy of currently used elastomeric impression materials for complete arch impression taking. Five elastomers (Impregum, Permlastic, Express, Extrude, Examix) and one Irreversible hydrocolloid (Aroma-fine) were tested. For each material, 5 impressions were made of stainless steel model to which five tapered posts were attached. Custom trays were used for polyether and polysulfide impression materials, and putty/wash two step technique was used for addition polyvinylsiloxane impression materials. Improved stone mod els were poured to all impressions. Accuracy of the materials was assessed by measuring ten distances on stone dies poured from impressions of the master model. All measurements for master and improved stone models were made with three dimensional measuring machine. The results were as follows 1. The dimensional accuracy of polyether, extrude, and examix were significantly superior to poly-sulfide, exress, and alginate in reproducing full arch mode (p<0.05) 2. There were no statistical differences in dimensional accuracy for full arch impression between polyether extrude and examix (p>0.05). 3. there were no statistical differences in dimensional accuracy between polysulfide, express, and alginate(p>0.05). 4. There were no statistical differences between addition polyvinyl siloxane materials (p>0.05) 5. There were no statistical differences between anterior-posterior and lateral dimensional changes of all impression materials (p>0.05).

  • PDF

실란계 혼화제를 활용한 소수성 시멘트 모르타르의 기초물성 연구 (A Study on the Fundamental Mechanical Properties of Hydrophobic Cementeous Mortar using Silane Admixtures)

  • 오홍섭
    • 한국건설순환자원학회논문집
    • /
    • 제6권2호
    • /
    • pp.79-86
    • /
    • 2018
  • 본 연구에서는 폴리비닐 알코올 계면활성제와 폴리메틸 하이드로 실록산을 혼합하여 에멀젼 형태의 소수성 혼화제를 제조하였으며, 이를 적용한 모르타르의 강도와 역학적 성질을 평가하였다. 개발된 소수성 혼화제는 강도 감소가 나타나지 않았으며, 산화마그네슘 혼입 모르타르는 조기에 강도가 발현되는 것으로 나타났다. 수밀성의 경우에는 모르타르에 소수성 혼화제를 직접 배합한 경우에 투수계수가 크게 감소하는 것으로 분석되었으나, 메타카올린에 의한 효과는 크지 않은 것으로 관찰되었다. 표면의 소수성은 표면을 코팅한 시편에서 접촉각이 증가하여 소수성 표면을 만드는 것은 확인되었으며, 혼화제에 사용된 섬유와 메타카올린의 혼입율이 최적화되지 않아 초소수성 표면을 갖지는 못하는 것으로 분석되었다.

Strain gauge를 사용한 임플랜트 인상법의 정확도 비교 (A COMPARATIVE ANALYSIS OF THE ACCURACY OF IMPLANT IMPRESSION TECHNIQUES BY USING STRAIN GAUGE)

  • 한인택;김영수;김창회
    • 대한치과보철학회지
    • /
    • 제33권3호
    • /
    • pp.539-549
    • /
    • 1995
  • The purpose of this study was to determine the accuracy of 3 implant impression methods by using strain gauge. The models used for this study were partially edentulous mandibular acrylic resin casts Model A, with two abutment analogs in #46,47 extraction site, represented two implant parallel to to the adjacent natural tooth. Model B represent an anterior implant parallel to the adjacene natural tooth and a posterior implant exhibiting a 15-degree lingual inclination. Master framework were fabricated on the master model, and 3 strain gauges were attached to a master framwork to determine the passivity of fit of the framework to sample casts made by the three impression techniques. The master framework was attached to each sample cast with gold screws, which were tightened with the torque driver to ensure a consistent toque application of 10 Ncm. Universal Digital Measuring System UCAM-5BT was used for strain measuring. Impression techniques studid were : 1. unsplinted tapered impression coping, polyvinyl siloxane, stock tray 2. unsplinted squared impression coping, polyether, custom tray 3. squared impression coping splinted with Duralay resin, polyether, custom tray Through analysis on data from this study, the following conclusions were obtained. 1. There were no statistically significant differences between the mean strain recorded from the sample casts made with the tree impression. But only strain values of model A(parallel group) Y-axis was signifcantly differed between Technique 1 and 3(P<0.05). 2. There was no statistically significant difference between model A(parallel group) and model B(15-degree divergent group).

  • PDF

부가중합 실리콘 인상재 및 모형재의 젖음성에 관한 비교 연구 (WETTABILITY OF POLYVINYLSILOXANE IMPRESSION MATERIALS AND IMPROVED STONE MATERIALS)

  • 조리라;정경호;김경남
    • 대한치과보철학회지
    • /
    • 제38권2호
    • /
    • pp.191-199
    • /
    • 2000
  • Wettability of addition silicone impression material is very important property for making an accurate restoration. This study examined the impression quality in clinical condition and the wettability of impression and die material. Four commercially available addition silicone impression material (Express, Examix, Contrast, Perfect) and three die materials (Die-Keen, Vel-Mix, Fuji-Rock) were studied. A total of 50 putty/wash and heavy body/wash impressions of wet intact permanent molar teeth were examined for definition of the gingival sulcus reproduction and then classified in quality ranking. The percentage of the sulcus reproduction ability of each material was calculated from the sulcus depths of cross-sectioned epoxy resin casts from the impressions and clinically measured sulcus depths, The same impression materials were used to produce 3 groups of die stone casts form void entrapment die had been exposed to milk. Voids in the impression body and stone casts ere counted under a stereoscopic microscope. From the experiment, the following results were obtained : 1. Sulcus reproduction ability of additional silicone impression material were diminished in order of Express, Examix, Perfect, Contrast. The significant difference was found between Perfect and other material. Heavy body/wash combination was superior In putty/wash method n Perfect impression material. 2. In direct observation, Contrast showed least void in impression body but correlations ere not found between sulcus reproduction and void production. 3. In void entrapment laboratory test, wettability were diminished in order of Examix, Contrast, Express, Perfect. Clinical impression recording seems not to correlate with laboratory test. 4. The wettability of die material to impression material was not different in Express, Examix, Contrast. But, in Perfect, Die-Keen had superior wettability to others.

  • PDF

Accuracy of intraoral scans of edentulous jaws with different generations of intraoral scanners compared to laboratory scans

  • Kontis, Panagiotis;Guth, Jan-Frederik;Schubert, Oliver;Keul, Christine
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권5호
    • /
    • pp.316-326
    • /
    • 2021
  • PURPOSE. Purpose of this in vitro study was to determine the accuracy of different intraoral scans versus laboratory scans of impressions and casts for the digitization of an edentulous maxilla. MATERIALS AND METHODS. A PEEK model of an edentulous maxilla, featuring four hemispheres on the alveolar ridges in region 13, 17, 23 and 27, was industrially digitized to obtain a reference dataset (REF). Intraoral scans using Cerec Primescan AC (PRI) and Cerec AC Omnicam (OMN), as well as conventional impressions (scannable polyvinyl siloxane) were carried out (n = 25). Conventional impressions (E5I) and referring plaster casts were scanned with the inEOS X5 (E5M). All datasets were exported in STL and analyzed (Geomagic Qualify). Linear and angular differences were evaluated by virtually constructed measurement points in the centers of the hemispheres (P13, P17, P23, P27) and lines between the points (P17-P13, P17-P23, P17-P27). Kolmogorov-Smirnov test and Shapiro-Wilk test were performed to test for normal distribution, Kruskal-Wallis-H test, and Mann-Whitney-U test to detect significant differences in trueness, followed by 2-sample Kolmogorov-Smirnov test to detect significant differences in precision (P < .008). RESULTS. Group PRI showed the highest trueness in linear and angular parameters (P < .001), while group E5I showed the highest precision (P < .001). CONCLUSION. Intraoral scan data obtained using Primescan showed the highest trueness while the indirect digitization of impressions showed the highest precision. To enhance the workflow, indirect digitization of the impression itself appears to be a reasonable technique, as it combines fast access to the digital workflow with the possibility of functional impression of mucosal areas.

광개시제에 따른 실험용 3D 프린팅 의치상 레진의 기계적 성질과 생체적합성 비교 (Comparison between mechanical properties and biocompatibility of experimental 3D printing denture resins according to photoinitiators)

  • 박다령;손주리
    • 대한치과기공학회지
    • /
    • 제42권4호
    • /
    • pp.355-361
    • /
    • 2020
  • Purpose: In this study, we added two kinds of photoinitiators (CQ and TPO) to prepare two kinds of denture base resins (Bis-GMA series and UDMA series) for three-dimensional (3D) printing to compare and analyze their mechanical and biological properties and to find the optimal composition. Methods: Control specimens were made using the mold made of polyvinyl siloxane of the same size. Light curing was performed twice for 20 seconds on both the upper and lower surfaces with LED (light emitting diode) light-curing unit (n=10). Experimental 3D printing dental resins were prepared, to which two photoinitiators were added. Digital light processing type 3D printer (EMBER, Autodesk, CA, USA) was used for 3D printing. The specimen size was 64 mm×10 mm×3.3 mm according to ISO 20795-1. The final specimens were tested for flexural strength and flexural modulus, and MTT test was performed. Furthermore, one-way analysis of variance was performed, and the post-test was analyzed by Duncan's test at α=0.05. Results: The flexural strength of both Bis-GMA+CQ (97.12±6.47 MPa) and UDMA+TPO (97.40±3.75 MPa) was significantly higher (p<0.05) in the experimental group. The flexural modulus in the experimental group of UDMA+TPO (2.56±0.06 GPa) was the highest (p<0.05). MTT test revealed that all the experimental groups showed more than 70% cell activity. Conclusion: The composition of UDMA+TPO showed excellent results in flexural strength, flexural modulus, and biocompatibility.

3D 프린팅을 이용한 양악 총의치 제작 증례 (Fabrication of complete denture using 3D printing: a case report)

  • 이은수;박찬;윤귀덕;임현필;박상원
    • 대한치과보철학회지
    • /
    • 제60권2호
    • /
    • pp.202-210
    • /
    • 2022
  • 최근 디지털 치의학의 발달로, Computer-aided design-Computer-aided manufacturing (CAD-CAM)을 이용한 의치 제작이 증가하는 추세이다. CAD 소프트웨어를 통해 디자인된 의치를 제작하는 방식에는 밀링을 이용한 절삭가공방식과 3D 프린팅과 같은 적층가공방식이 있으며, 적층가공방식은 보다 복잡한 구조를 재현하는데 유리하게 사용될 수 있다. 본 증례는 뇌경색으로 인해 신체적 장애를 갖게 된 상·하악 완전무치악 환자에서 제작 기간과 내원 간격을 단축하기 위해 광경화 Stereolithography (SLA) 기반의 3D 프린팅을 이용한 디지털 제작 방식의 양악 총의치 수복 증례이다. 최종인상채득을 위해 기존 임시의치를 디지털 방식으로 복제 및 출력하여 개인트레이로 활용하였고, 부가중합형 실리콘 인상재로 채득한 최종인상체에는 수직고경과 중심위, 상악 전치부의 각도 및 길이에 대한 정보가 포함되었다. 또한 임시의치를 장착하고 촬영한 안면 스캔 데이터를 추가로 획득하여 기공 작업 시 교합평면 결정이나 인공치 배열에 참고할 수 있도록 하였다. 인상체를 3차원 스캔 후 CAD 프로그램을 통해 인공치를 배열하였고, 연마면을 형성하여 의치 디자인을 완성하였다. 시적 의치 및 최종 의치는 FDA 승인을 받은 액체 광경화성 레진을 이용하여 SLA 기반 3D 프린터로 출력하였고, 최종 의치는 적절한 안정과 유지, 지지를 보였으며, 기능적, 심미적으로 만족스러운 결과를 얻을 수 있었다. 최종 의치의 전달까지 3회의 내원 횟수를 필요로 하였으며, 기공시간의 단축으로 내원 간격을 줄임으로써 환자의 만족도를 증진시켰다.

하악 편위 환자에서 디지털 방식을 이용한 총의치 제작 증례 (Fabrication of complete denture using digital technology in patient with mandibular deviation: a case report)

  • 이은수;박주영;박찬;윤귀덕;임현필;박상원
    • 구강회복응용과학지
    • /
    • 제38권1호
    • /
    • pp.34-41
    • /
    • 2022
  • 최근 디지털 기술과 Computer-aided design/Computer-aided manufacturing (CAD/CAM) 작업 환경은 의치 제작에 있어 임상의의 진료 과정의 변화를 가져왔다. CAD/CAM 기술을 이용한 의치 제작 방식은 진료 및 기공 과정을 단순화하여 오류의 발생을 감소시키며, 임상적인 효율성과 편리함을 제공한다. 본 증례는 하악 편위를 가진 상·하악 완전 무치악 환자에서 광경화 SLA 기반의 3D 프린팅을 이용한 디지털 제작 방식의 양악 총의치 수복 증례이다. 구강 스캐너로 채득한 디지털 모형에서 기록상을 제작하였고 교합제에 악간관계를 기록한 후 부가 중합형 실리콘 인상재로 폐구 정밀 인상을 채득하였다. 또한 교합제를 장착하고 촬영한 안면 스캔 데이터를 추가로 획득하여 기공 작업 시 교합 평면 결정이나 인공치 배열에 참고할 수 있도록 하였다. 인상체를 3차원 스캔 후 CAD 프로그램을 통해 인공치를 배열하였고, 연마면을 형성하여 의치 디자인을 완성하였다. 시적 의치 및 최종 의치는 미국식품의약국(Food and Drug Administraion, FDA) 승인을 받은 액체 광경화성 레진을 이용하여 stereolithography (SLA) 기반 3D 프린터로 출력하였고, 최종 의치는 적절한 안정과 유지, 지지를 보였으며 기능적, 심미적으로 만족스러운 결과를 얻을 수 있었다.