• 제목/요약/키워드: polymethylmethacrylate (PMMA)

검색결과 140건 처리시간 0.027초

Color alterations of a PMMA resin for fixed interim prostheses reinforced with silica nanoparticles

  • Kotanidis, Alexandros;Kontonasaki, Eleana;Koidis, Petros
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권4호
    • /
    • pp.193-201
    • /
    • 2019
  • PURPOSE. The aim of the present study was to evaluate the color changes of an autopolymerizing PMMA resin used for interim fixed restorations, reinforced with $SiO_2$ nanoparticles. MATERIALS AND METHODS. Silica nanoparticles were blended with the PMMA resin powder through high-energy ball milling. Four shades of PMMA resin were used (A3, B3, C3, D3) and total color differences were calculated through the equations ${\Delta}E_{ab}=[({\Delta}L*)^2+({\Delta}a*)^2+({\Delta}b*)^2]^{1/2}$ and ${\Delta}E_{00}=[(\frac{{\Delta}L^{\prime}}{K_LS_L})^2+(\frac{{\Delta}C^{\prime}}{K_CS_C})^2+(\frac{{\Delta}H^{\prime}}{K_HS_H})^2+R_T(\frac{{\Delta}C^{\prime}}{K_CS_C})(\frac{{\Delta}H^{\prime}}{K_HS_H})]^{1/2}$. Statistically significant differences between ${\Delta}E_{ab}$ and the clinically acceptable values of 3.3 and 2.7 and those between ${\Delta}E_{00}$ and the clinically acceptable value of 1.8 were evaluated with one sample t-test (P<.05). Differences among the different shades were assessed through One-Way ANOVA and Bonferroni multiple comparison tests. RESULTS. Significantly lower values were detected for all groups concerning ${\Delta}E_{ab}$ compared to the intraorally clinical acceptable values of 3.3 and 2.7. Significantly lower mean values were detected for groups B3, C3, and D3, concerning ${\Delta}E_{00}$ compared to the intraorally clinical acceptant value of 1.8. Color pigments in red-brown (A3) and red-grey (D3) shades affect the total color change to a greater extent after the reinforcement with $SiO_2$ nanoparticles compared to the red-yellow (B3) shade. CONCLUSION. Within the limitations of this in vitro study, it can be suggested that reinforcing PMMA with $SiO_2$ nanoparticles at 0.25 wt% slightly affects the optical properties of the PMMA resin without being clinically perceivable.

인젝션 몰딩 기술을 이용한 마이크로 구조물 성형 (Micro Structure Fabrication Using Injection Molding Method)

  • 제태진;신보성;정석원;조진우;박순섭
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2002년도 금형가공 심포지엄
    • /
    • pp.253-259
    • /
    • 2002
  • Micro cell structures with high aspect ratio were fabricated by injection molding method. The mold inserts had dimension $1.9cm\times8.3cm$ composed of a lot of micro posts and were fabricated by LIGA process. The size of the micro posts was $157{\mu}m\times157{\mu}m\times500{\mu}m$ and the gaps between two adjacent posts were $50{\mu}m$. Using Polymethylmethacrylate (PMMA) injection molding was performed. The key experimental variables were temperature, pressure, and time. By controlling these, good shaped mim cell structures with $50{\mu}m$ in wall thickness and $500{\mu}m$ in depth were obtained. In order to understand micro molding mechanism, shape changes of molded PMMA were studied with experimental variables. And the durability of mold insert was investigated, too. The results show that the most important factor in molding processes was the mold temperature that is closely related to the filling of the melt into the micro cavity. And the holding time before cooling showed a great effect on the quality of molded PMMA.

  • PDF

Repeat Vertebroplasty for the Subsequent Refracture of Procedured Vertebra

  • Choi, Sang Sik;Hur, Won Seok;Lee, Jae Jin;Oh, Seok Kyeong;Lee, Mi Kyoung
    • The Korean Journal of Pain
    • /
    • 제26권1호
    • /
    • pp.94-97
    • /
    • 2013
  • Vertebroplasty (VP) can effectively treat pain and immobility caused by vertebral compression fracture. Because of complications such as extravasation of bone cement (polymethylmethacrylate, PMMA) and adjacent vertebral fractures, some practitioners prefer to inject a small volume of PMMA. In that case, however, insufficient augmentation or a subsequent refracture of the treated vertebrae can occur. A 65-year-old woman visited our clinic complaining of unrelieved severe low back and bilateral flank pain even after she had undergone VP on the $1^{st}$ and $4^{th}$ (L1 and L4) lumbar vertebrae a month earlier. Radiologic findings showed the refracture of L1. We successfully performed the repeat VP by filling the vertebra with a sufficient volume of PMMA, and no complications occurred. The patient's pain and immobility resolved completely three days after the procedure and she remained symptom-free a month later. In conclusion, VP with small volume cement impaction may fail to relieve fracture-induced symptoms, and the refracture of an augmented vertebral body may occur. In this case, repeat VP can effectively resolve both the persistent symptoms and problems of new onset resulting from refracture of the augmented vertebral body due to insufficient volume of bone cement.

UV 임프린팅법에 의한 필름형 광도광판의 제조 및 특성 연구 (Fabrication and Characterization of Film Type Light Guide Plates by UV Imprint Lithography)

  • 김형관;김소원;이희철
    • 한국표면공학회지
    • /
    • 제49권2호
    • /
    • pp.178-185
    • /
    • 2016
  • In this study, we have fabricated light guide plates (LGPs) in thin film form for edge type back light unit (BLU) by using UV imprint lithography. In the LGPs, the pattern of functional resins on PC and PMMA substrates were successfully transferred from original master mold through PVC stamp. Optimized pattern arrays with slowly-sloped density were designed to obtain high brightness and uniformity. We could obtain a relatively improved brightness of $950cd/m^2$ and a uniformity of 87.3% by using the NP-S20 functional resins at an input power of 1.3 W because NP-S20 resin could show high formability after UV hardening process. The LGP prepared on polymethylmethacrylate (PMMA) substrate exhibited higher brightness than that on polycarbonate (PC) substrate because PMMA has lower refractive index resulting in more refraction toward the vertical direction.

극미세 점 구조체 제작을 위한 열간나노압입 공정에서의 평판형 PMMA의 크립현상에 관한 연구 (A study on Creep of Plate PMMA in Thermal-Nanoindentation Process for Hyperfine pit structure Fabrication)

  • 이은경;정유나;강충길
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2008년도 춘계학술대회 논문집
    • /
    • pp.273-276
    • /
    • 2008
  • Thermoplastic resin takes place stress relaxation and creep according to temperature and time. In room temperature, time dependent deformation (TDD) of polymer was carried out at previous study. In this study, it evaluates time dependent deformation to relate temperature. Nanoscale indents can be used as cells for molecular electronics and drug delivery, slots for integration into nanodevices, and defects for tailoring the structure and properties. Therefore, it is important to control pattern depth for change of indent depth by creep when using Nanoindenter. For evaluating TDD at high temperature, it is occurred thermal-nanoindentation test by changing hold time at maximum load. Temperature is putted at $90^{\circ}C$, hold time at maximum loads are putted at 1, 10, 50, 100, 200, 300 and 500s.

  • PDF

Evaluating the absorption loading technique to acrylic resin for drug delivery

  • Al-Kaabi, Arshad F.;Hamid, Mohammed A.
    • Advances in materials Research
    • /
    • 제11권2호
    • /
    • pp.165-170
    • /
    • 2022
  • Acrylic resin or polymethylmethacrylate (PMMA) is one of the most attractive materials to be used for dental appliances manufacturing. It has been introduced as a biomaterial during the last century. This study aims to evaluate the compounds absorption and release through acrylic resin to be used for drug delivery as well. The study specimens were 10 pieces of heat-cured clear acrylic resin with dimensions of 10 × 10 × 2 mm. The specimens were dipped in methylene blue solution at a powder-water ratio of 1:20 for 5 days. The samples were removed and dipped in 5 ml distilled water vials for 24 hours. Then the specimens were replaced into new 5 ml vials and the process lasted for 4 days. The extracted solutions were analyzed by the visible light spectroscopy for absorbance. The statistical results showed a gradual increase in stain release from day 1 to day 4 with a significant difference between day 1 and day 4 solutions. The study showed that PMMA resin is able to absorb and release some compounds constantly and the absorption drug-loading technique is applicable to this material.

등쪽 관골절구 결손을 가진 진도견의 인공 대퇴 관절 전치환술 (Total Hip Replacement in a Jindo Dog with Dorsal Acetabular Rim Deficiency: a Case Report)

  • 허수영;이해범
    • 한국임상수의학회지
    • /
    • 제31권2호
    • /
    • pp.121-124
    • /
    • 2014
  • 7년령의 암컷 진도견이 뒷다리 파행을 주증으로 내원하였다. 신체검사상에서 대퇴관절의 신전시 염발음과 통증을 보였고 방사선 검사상에서 양측 대퇴 관절 이형성증에 의한 퇴행성 관절염과 오른쪽 부위의 전측 대퇴 탈구를 보여 주었다. 오른쪽 관절의 탈구의 치료를 위해 인공 대퇴 관절 전치환 술을 실시하였다. 수술 중 오른쪽 등쪽 관절절구의 결손으로 인한 인공 관절절구 컵의 탈구의 위험성을 확인하고 등쪽 관절절구의 결손을 잠김 금속판과 골시멘트를 이용하여 보강하였다. 수술 후 환자는 성공적인 결과를 보여주었다. 또한 오른쪽 대퇴관절의 관절 운동 범위과 근육량이 개선 되었다. 등쪽 관골절구 결손을 가진 대퇴 관절 탈구에서 잠김 금속판과 골시멘트 이용하여 인공 대퇴관절 전치환술을 성공적으로 실시하였다. 본 증례와 같은 수술 기법이 등쪽 관골절구 결손이 있을 시 사용될 수 있다고 생각된다.

화재 시 연소성 물질에 대한 화재 위험성 등급 평가 (Rating Evaluation of Fire Risk for Combustible Materials in Case of Fire)

  • 정영진;진의
    • 공업화학
    • /
    • 제32권1호
    • /
    • pp.75-82
    • /
    • 2021
  • 본 연구는 건자재용 목재 및 플라스틱의 화재위험성 평가에 대하여 새로 고안된 화재성능지수-III (FPI-III), 화재성장지수-III (FGI-III), 화재위험성지수-IV (FRI-IV)를 중심으로 조사하였다. 시험편은 삼나무, 적송, PMMA, PVC를 사용하였다. 화재 특성은 시험편에 대하여 콘칼로리미터(ISO 5660-1) 장비를 이용하여 조사하였다. 연소반응 후 측정된 화재성능지수-III는 PMMA를 기준으로 1.0~15.0으로 나타났다. 화재성능지수-III에 의한 화재위험성은 PVC, 적송, 삼나무, PMMA 순서로 증가하였다. 화재성장지수-III는 PMMA를 기준으로 0.5~3.3으로 나타났다. 화재성장지수-III에 의한 화재위험성은 PVC, PMMA, 적송, 삼나무의 순서로 증가하였다. 모든 시편의 CO 피크농도는 106~570 ppm으로 측정되었다. 결론적으로 체적밀도가 낮은 삼나무와 PMMA와 같이 휘발성 유기물질을 다량 함유한 재료는 화재성능지수-III가 낮고, 화재성장지수-III가 높으므로 화재로 인한 화재위험성이 높은 것으로 이해된다. 이는 화재위험성지수-IV와 일치하였다.

Color stability of 3D-printed denture resins: effect of aging, mechanical brushing and immersion in staining medium

  • Alfouzan, Afnan Fouzan;Alotiabi, Hadeel Minife;Labban, Nawaf;Al-Otaibi, Hanan Nejer;Taweel, Sara Mohammad Al;AlShehri, Huda Ahmed
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권3호
    • /
    • pp.160-171
    • /
    • 2021
  • Purpose. This in-vitro study evaluated and compared the color stability of 3D-printed and conventional heat-polymerized acrylic resins following aging, mechanical brushing, and immersion in staining medium. Materials and methods. Forty disc-shaped specimens (10 mm in diameter and 3 mm thick) were prepared from two 3D-printed [DentaBASE (DB) and Denture 3D+ (D3D)] and one conventional polymethylmethacrylate (PMMA) denture materials. The specimens were thermo-cycled, subjected to mechanical brushing, and were immersed in either coffee, lemon juice, coke, or artificial saliva (AS) to simulate one and two years of oral use. Color measurements of the specimens were recorded by a spectrophotometer at baseline (T0), and after one (T1) and two years (T2) of simulation. The color changes (ΔE) were determined and also quantified according to the National Bureau of Standards (NBS) units. Descriptive statistics, followed by factorial ANOVA and Bonferroni post-hoc test (α=.05), were applied for data analysis. Results. The independent factors, namely material, staining medium, and immersion time, and interaction among these factors significantly influenced ΔE (P<.009). Irrespective of the materials, treatments, and time, the highest and the lowest mean ΔEs were observed for PMMA in lemon juice (4.58 ± 1.30) and DB in AS (0.41 ± 0.18), respectively. Regarding the material type, PMMA demonstrated the highest mean ΔE (2.31 ± 1.37), followed by D3D (1.67 ± 0.66), and DB (0.85 ± 0.52), and the difference in ΔE between the materials were statistically significant (P<.001). All the specimens demonstrated a decreased color changes at T2 compared to T1, and this difference in mean ΔE was statistically significant (P<.001). Conclusion. The color changes of 3D-printed denture resins were low compared to conventional heat polymerized PMMA. All the tested materials, irrespective of the staining medium used, demonstrated a significant decrease in ΔE values over time.

DBR 다공성 실리콘/고분자 Composite 재료-이중적 광학특성 (DBR PSi/Polymer Composite Materials -Dual Photonic Characteristics)

  • 박철영;장승현;김지훈;박재현;고영대;김성진;고영춘;손홍래
    • 한국진공학회지
    • /
    • 제16권3호
    • /
    • pp.221-226
    • /
    • 2007
  • 광 발광성 (photoluminescence, PL)과 광 반사성(reflectivity)의 두 가지 광학적 성질을 동시에 가지고 있는 새로운 다층 DBR(distributed Bragg reflector) 다공성 실리콘 composite 필름을 개발하였다. 발광 효율이 높은 실리콘 고분자 폴리실올을 PMMA(polymethylmethacrylate)에 첨가하여 다층 DBR 다공성 실리콘 표면에 코팅을 한 composite 필름을 제조하였다. 이 composite 필름은 510 nm에서의 발광스펙트럼과 565 nm에서의 반사스펙트럼을 동시에 나타낸다. 이러한 composite 필름은 광학적 정보가 저장되어있고 물리적인 힘을 가하여도 그 광학적 정보를 잃지 않는 장점을 갖는다. 또한 다층 DBR 다공성 실리콘 필름은 쉽게 부서지는 단점 때문에 다루기가 어려운 반면 composite 필름은 고분자로 고형화 되어있으므로 기계적인 안정도를 증가시킬 수 있었다.