• Title/Summary/Keyword: polymeric materials

Search Result 850, Processing Time 0.026 seconds

INTUMESCENT INORGANIC AND ORGANIC COATINGS

  • Kodolov, V.I.;Mikhalkina, T.M.;Shuklin, S.G.;Bystrov, S.G.;Larionov, K.I.
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.130-137
    • /
    • 1997
  • Intumescent inorganic and organic coatings which dintr one from the other by the type of gas formers and the mechanisms of foam formation have been obtained and investigated. Inorganic intumescent coatings are the compositions based on water glass and mineral additives with different dispersity. Mineral additives contain adsorbed and absorbed water and carbonates which are destructed with the carbon dioxide and water evolution during the flame action on coating. The decreasing of mineral additives particle sizes under the mechanical milling with the fraction precipitation promotes the foam coke formation with less defects. Here the main structure of comparing compositions does not change. In organic coatings based on epoxy-polymers the polyammonium phosphate additive is used. It is the cabonization catalyst and the foam agent. The polyammonium phosphate of various dispersity employed is uniformly distributed on the polymeric matrix. The decreasing of the particle sizes leads to the increasing of the fire resistant properties of the intumescent coa-ting. The fire resistant analysis of the coating during more than an hour: the coating back side the temperature on plastic or wooden materials does not exceed 423K, and on metal-573K.

  • PDF

Removal of textile dyes in wastewater using polyelectrolytes containing tetrazole groups

  • Caldera-Villalobos, Martin;Pelaez-Cid, Alejandra-Alicia;Martins-Alho, Miriam-Amelia;Herrera-Gonzalez, Ana-Maria
    • Korean Journal of Chemical Engineering
    • /
    • v.35 no.12
    • /
    • pp.2394-2402
    • /
    • 2018
  • Textile dyes are some of the pollutants which have received the most attention because of the large volume of wastewater generated by the textile industry. Removal by means of adsorption is one of the most versatile alternatives to treat these effluents. Even though different adsorbents such as activated carbons and mineral materials have been proposed, polymeric adsorbents are a viable alternative. This work reports for the first time the use of polyelectrolyte PTZ and macroelectrolyte MTZ containing tetrazole groups as adsorbents useful in the textile dyes removal present in aqueous solutions and wastewater. Because of the anionic character of the tetrazole group, MTZ exhibits selective adsorption capabilities for cationic dyes of up to $156.25mg{\cdot}g^{-1}$. The kinetic study of the process of adsorption shows that PTZ and MTZ fit a pseudo second-order model. MTZ also shows utility as a flocculant agent in the treatment of wastewater containing dyes Indigo Blue and Reactive Black. The results showed that PTZ and MTZ may be used in the treatment of wastewater in a process of coagulation-flocculation followed by the treatment by adsorption. This two-stage treatment removed up to 95% of the dye present in the wastewater. As well as removing the dyes, the values for COD, suspended solids, pH, and color of the wastewater decreased, thus significantly improving its quality.

Surface Modification of Polymeric Material Using Atmospheric Plasma (대기압 플라즈마를 이용한 고분자 소재의 표면개질)

  • Sim, Dong-Hyun;Seul, Soo-Duk
    • Polymer(Korea)
    • /
    • v.32 no.5
    • /
    • pp.433-439
    • /
    • 2008
  • An atmospheric plasma pre-treatment method was applied to polyurethane foam (density: 0.27) and rubber (butadiene rubber) to improve its contact angle and adhesion using atmospheric plate type reactor. In order to investigate the optimum reaction condition of plasma treatment, type of treatment gas (nitrogen, argon, oxygen, air), rate of gas flow ($30{\sim}100\;mL/min$), and treated time ($0{\sim}30\;s$) were examined in a plate plasma reactor. The result of the surface modification with respect to the treatment procedure was characterized by using SEM and ATR-FTIR. Due to a decrease of the contact angle of various materials, the greatest adhesion strength was achieved at optimum condition such as flow rate of 100 mL/min, reaction time of polyurethane foam 10 s and rubber 3 s for an atmosphere nitrogen gas. Consequently, the atmospheric plasma treatment reduced the wettability of the polyurethane foam and rubber also resulted in the improvement of the adhesion.

Layer-by-layer assembled polymeric thin films as prospective drug delivery carriers: design and applications

  • Park, Sohyeon;Han, Uiyoung;Choi, Daheui;Hong, Jinkee
    • Biomaterials Research
    • /
    • v.22 no.4
    • /
    • pp.290-302
    • /
    • 2018
  • Background: The main purpose of drug delivery systems is to deliver the drugs at the appropriate concentration to the precise target site. Recently, the application of a thin film in the field of drug delivery has gained increasing interest because of its ability to safely load drugs and to release the drug in a controlled manner, which improves drug efficacy. Drug loading by the thin film can be done in various ways, depending on type of the drug, the area of exposure, and the purpose of drug delivery. Main text: This review summarizes the various methods used for preparing thin films with drugs via Layer-by-layer (LbL) assembly. Furthermore, additional functionalities of thin films using surface modification in drug delivery are briefly discussed. There are three types of methods for preparing a drug-carrying multilayered film using LbL assembly. First methods include approaches for direct loading of the drug into the pre-fabricated multilayer film. Second methods are preparing thin films using drugs as building blocks. Thirdly, the drugs are incorporated in the cargo so that the cargo itself can be used as the materials of the film. Conclusion: The appropriate designs of the drug-loaded film were produced in consideration of the release amounts and site of the desired drug. Furthermore, additional surface modification using the LbL technique enabled the preparation of effective drug delivery carriers with improved targeting effect. Therefore, the multilayer thin films fabricated by the LbL technique are a promising candidate for an ideal drug delivery system and the development possibilities of this technology are infinite.

A Review on Ceramic Based Membranes for Textile Wastewater Treatment (염색폐수의 처리를 위한 세라믹 분리막에 대한 고찰)

  • Kwak, Yeonsoo;Rajkumar, Patel
    • Membrane Journal
    • /
    • v.32 no.2
    • /
    • pp.100-108
    • /
    • 2022
  • Among various industries, the textile industry uses the largest amount of water for coloring textiles which leads to a large amount of wastewater containing various kinds of dye. There are various methods for the removal of dye such as flocculation, ozone treatment, adsorption, etc. But these processes are not much successful due to the issue of recycling which enhances the cost. Alternatively, the membrane separation process for the treatment of dye in wastewater is already documented as the best available technique. Polymeric membrane and ceramic membrane are two separate groups of separation membranes. Advantages of ceramic membranes include the ease of cleaning, long lifetime, good chemical and thermal resistance, and mechanical stability. Ceramic membranes can be prepared from various sources and natural materials like clay, zeolite, and fly ash are very cheap and easily available. In this review separation of wastewater is classified into mainly three groups: ultrafiltration (UF), microfiltration (MF), and nanofiltration (NF) process.

Development of bio-inspired hierarchically-structured skin-adhesive electronic patch for bio-signal monitoring (생체정보 진단을 위한 생체모사 계층구조 기반 피부 고점착 전자 패치 개발)

  • Kim, Da Wan
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.5
    • /
    • pp.749-754
    • /
    • 2022
  • High adhesion and water resistance of the skin surface are required for wearable and skin-attachable electronic patches in various medical applications. In this study, we report a stretchable electronic patch that mimics the drainable structure pattern of the hexagonal channels of frog's pads and the sucker of an octopus based on carbon-based conductive polymer composite materials. The hexagonal channel structure that mimics the pads of frogs drains water and improves adhesion through crack arresting effect, and the suction structure that mimics an octopus sucker shows high adhesion on wet surfaces. In addition, the high-adhesive electronic patch has excellent adhesion to various surfaces such as silicone wafer (max. 4.06 N/cm2) and skin replica surface (max. 1.84 N/cm2) in dry and wet conditions. The high skin-adhesive electronic patch made of a polymer composite material based on a polymer matrix and carbon particles can reliably detect electrocardiogram (ECG) in dry and humid environments. The proposed electronic patch presents potential applications for wearable and skin-attachable electronic devices for detecting various biosignals.

Recent Development Based on 2D Composite Membrane for Pervaporation (투과증발을 위한 2차원 복합막 기반의 최근 개발)

  • Seungwoo Ha;Rajkumar Patel
    • Membrane Journal
    • /
    • v.33 no.4
    • /
    • pp.158-167
    • /
    • 2023
  • The increasing concerns for environmental pollution and depletion of natural resources have prompted the development of environmentally sustainable technologies. Pervaporation has garnered attention in recent decades due to its low energy consumption, environmental impact, and performance efficiency. This method has been used to separate chemical species and dehydrate organic solvents, as the membranes can be fine-tuned to fulfill the desired selectivity. Several separation processes, such as reverse osmosis and distillation, are being utilized in both experimental settings and industrial applications. However, pervaporation has several advantages, such as low operating pressure and temperature and a higher rejection rate. Nonetheless, the current state of membrane technology alone can't suffice the demands of practical applications. Composite membranes, on the other hand, can leverage the benefits of both organic and inorganic materials. Many studies have effectively incorporated inorganic nanomaterials such as graphene oxide (GO) and MXene (MX) in polymeric membranes to tackle the current limitations. This review investigates the recent development of 2D composite membranes in pervaporation and evaluates performance enhancement.

Effect of Filled Hole on Strength Behavior of CFRP Composites at Cold Temperature Dry and Elevated Temperature Wet (저온건조($-55^{\circ}C$) 및 고온다습 조건($108.3^{\circ}C$)의 기계적 체결 홀이 탄소섬유강화 복합재의 강도 특성에 미치는 영향 연구)

  • Kim, Hyo-Jin
    • Composites Research
    • /
    • v.22 no.3
    • /
    • pp.82-88
    • /
    • 2009
  • The effect of open and filled holes on the strength behavior of carbon fiber reinforced polymeric (CFRP) composites was investigated. The strength was measured at room temperature dry, cold temperature dry, $-55^{\circ}C$, and elevated temperature wet, $108.3^{\circ}C$ on several different laminate configurations. Based on the experimental data presented, it is shown that the filled hole tensile strength is larger than that of open hole by reducing damage around the hole due to the constraint imposed by the fastener. The tensile strength at cold temperature dry, $-55^{\circ}C$ is increased with the brittleness by the thermal expansion coefficient of fiber and matrix. The compressive strength at elevated temperature wet, $108.3^{\circ}C$ is decreased by the cause of interfacial deterioration between fiber and matrix with moisture absorption.

Effect of Cold Temperature Dry and Elevated Temperature Wet on Mechanical Properties of CFRP Composites (냉각($-55^{\circ}C$) 및 고온다습 조건($82.2^{\circ}C$)이 탄소섬유강화 복합재의 기계적 특성에 미치는 영향 연구)

  • Kim, Hyo-Jin;Lee, Sih-Joong;Han, Sang-Ho;Kim, Sang-Kuk;Park, Seong-Jun
    • Composites Research
    • /
    • v.22 no.3
    • /
    • pp.60-65
    • /
    • 2009
  • The mechanical behavior of carbon fiber reinforced polymeric (CFRP) composites was investigated. Both strength and modulus were measured at room temperature dry, cold temperature dry, $-55^{\circ}C$, and elevated temperature wet, $82.2^{\circ}C$ on seven different laminate configurations consisting of $[0_6]_T$, $[90_{12}]_T$, $[0_{16}]_T$ and $[90_{16}]_T$ unidirectional laminates, $[{\pm}45]_{5S}$ angle-ply laminate, $[0/90_{12}/0]_T$ cross-ply laminate, a 36-ply laminate $[0/45/-45/45/-45/0]_{3S}$. Based on the experimental data presented, it is shown that the strength at cold temperature dry, $-55^{\circ}C$ is increased with the brittleness of fiber or matrix. Moreover, it is shown that both shear strength and modulus at elevated temperature wet, $82.2^{\circ}C$ are decreased by the cause of interfacial deterioration between fiber and matrix with moisture absorption.

Flow characteristics and alkalinity of novel bioceramic root canal sealers

  • Anastasios Katakidis;Konstantinos Sidiropoulos;Elisabeth Koulaouzidou;Christos Gogos;Nikolaos Economides
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.4
    • /
    • pp.42.1-42.9
    • /
    • 2020
  • Objective: This study aimed to examine the physical properties (pH and flow) of 2 novel bioceramic sealers. Materials and Methods: The tested sealers were a calcium hydroxide sealer (Sealapex) and 2 bioceramic sealers (BioRoot RCS and TotalFill BC Sealer). Flow measurements were conducted according to ISO 6876/2012, with a press method of 0.05 mL of sealer. The pH of fresh samples was tested immediately after manipulation, while set samples were stored for 3 times the recommended setting time. The predetermined time intervals ranged from 3 minutes to 24 hours for fresh samples and from 10 minutes to 7 days and 4 weeks for the set samples. Analysis of variance was performed, with p = 0.05 considered indicating significance. Results: The mean flow values were 26.99 mm for BioRoot, 28.19 for Sealapex, and 30.8 mm for TotalFill BC Sealer, satisfying the ISO standard. In the set samples, BioRoot RCS had higher pH values at 24 hours to 1 week after immersion in distilled water. At 2 weeks, both bioceramic sealers had similar pH values, greater than that of Sealapex. In the fresh samples, the bioceramic sealers had significantly higher initial pH values than Sealapex (p < 0.05). At 24 hours post-immersion, all sealers showed an alkaline pH, with the highest pH observed for TotalFill. Conclusions: The TotalFill BC Sealer demonstrated the highest flow. The bioceramic sealers initially presented higher alkaline activity than the polymeric calcium hydroxide sealer. However, at 3 and 4 weeks post-immersion, all sealers had similar pH values.