• Title/Summary/Keyword: polymer-cement composites

Search Result 42, Processing Time 0.023 seconds

RC 구조물의 균열 보수용 폴리머 시멘트 복합체의 점도와 유동성에 관한 연구 (A Study on the Viscosity and Flowability of Polymer-Cement Composites for Repairing Cracks of RC Structures)

  • 홍대원;김상혁;권우찬;조영국
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.166-167
    • /
    • 2021
  • The purpose of this study is to evaluate the viscosity and flowability of polymer-cement composites for repairing cracks of RC structures. The viscosity and flowability of the polymer cement composites differed greatly depending on the type of polymer and the polymer cement ratio, and the polymer cement composites could be produced that could repair fine cracks in the RC structure without material separation by adjusting the proper water-cement ratio. In particular, the mixing of high viscosity EVA-modified polymer composites could be adjusted.

  • PDF

경량골재를 사용한 콘크리트 복합체의 단열성능에 관한 연구 (A Study on the Thermal Insulation Property of Concrete Composites using Light-weight Aggregate)

  • 소승영
    • 한국건축시공학회지
    • /
    • 제4권3호
    • /
    • pp.93-100
    • /
    • 2004
  • In recent years, it has widely been studied on the light-weight composites for the purpose of the large space and thermal insulation of building structures. The purpose of this study is to evaluate the properties of light-weight composites made by binders as cement, resin and polymer cement slurry. The concrete composites are prepared with various conditions such as polymer-cement ratio, void-filling ratio, type of resin, filler content and light-weight aggregate content, tested for thermal conductivity. From the test results, the thermal conductivity of concrete composites with the binder of cement tends to decrease with increasing polymer-cement ratio, and to increase with increasing void-filling ratio. The thermal conductivity of concrete composites with the binder of resin are markedly affected by the light-weight aggregate content, type of resin and filler content. The composites made by polymer-modified concrete and polymer cement slurry have a good thermal insulation property. From the this study, we can recommend the proper mix proportions for thermal insulation Panel or concrete. Expecially. the thermal conductivity of concrete composites made by polyurethane resin is almost the same as that of the conventional expanded polystyrene resin.

복합열화 환경을 받는 콘크리트 시설물을 위한 보수용 폴리머 시멘트 복합체의 내구성능 향상에 관한 연구 (Enhanced Durability Performance of Polymer Modified Cement Composites for Concrete Repair Under Combined Aging Conditions)

  • 원종필;박찬기
    • 한국농공학회논문집
    • /
    • 제47권6호
    • /
    • pp.27-34
    • /
    • 2005
  • The purpose of this study is to improve the durability performance of polymer modified cement composites for repair of concrete under combined aging conditions. The experimental procedure was divided into three parts. First, the replacement level of mineral admixtures in polymer modified cement composites were determined in an experimental study based on a Box Behnken design. Second, the flow value, compressive strength and chloride permeability test of sixteen types of mixtures were conducted. Test results show that the polymer modified cement composites were effected on the improvement of the compressive strength and permeability performance. Third, the effects on the replacement level of silica fume mixture was evaluated by the compressive strength, chloride permeability, chemical resistance and repeated freezing and thawing cycles test. They demonstrated that the polymer modified cement composites using mixture of silica fume, fly ash, and blast furnace slag improved the durability performance.

균열보수용 폴리머 시멘트 복합체의 휨접착 성능에 관한 연구 (A Study on the Adhesion in Flexure Property of Polymer-Cement Composites for Crack Repair)

  • 권우찬;박동엽;조영국
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.159-160
    • /
    • 2022
  • The purpose of this study is to evaluate the adhesion in flexure depending on the cement type, polymer type, polymer-cement ratio, and silica fume ratio of the polymer-cement composites(PCCs) for crack repair in RC structures to induce optimal mix proportions. The adhesion in flexure of PCCs for crack repair of RC structure has a significant effect on the polymer type and polymer-cement ratio, and the adhesion in flexure is generally improved with mixing of silica fume as a mixture. The adhesion in flexure according to the type of polymer is slightly higher in the order of SAE, EVA, and SBR, and it is relatively high at the polymer-cement ratio of 60% or 80%. In addition, the adhesion in flexure of PCCs with silica fume ratio of 10% or 20% to the cement weight is higher than that without silica fume. In order to improve the adhesion in flexure of PCCs for repairing cracks in RC structures, the optimal mix design is to properly adjust the cement type, polymer type, polymer-cement ratio, and silica fume ratio.

  • PDF

시멘트 페이스트의 특성에 미치는 흡수성폴리머의 영향 (Effects of Absorbent Polymer on the Moisture Resistance and Hydration Characteristics of Cement Pastes)

  • 나종균;김창은;이승규
    • 한국세라믹학회지
    • /
    • 제36권5호
    • /
    • pp.539-546
    • /
    • 1999
  • Absorbent polymer-cement composites were fabricated by the semi-powder mixing OPC(ordinary Portland cement) with an absorbent polymer. The effects of absorbent polymer on the mechanical properties and the hydration characteristics were observed and the polymer-cement interaction also discussed. Absorbent polymer-cement composites showed the value of total porosity of 8vol% the value of 28 days flexural strength was up to 280 Kgf/cm2 in the case of absorbent polymer-cement composite at 1 wt% absorbent polymer content and microstructure of absorbent polymer-cement composite has been observed more dense than that of OPC paste. Accordingly the permeability of compositewas improved and so the moisture resistance was also increased. Adding polymer did not retard the hydration of OPC. It was considered from the results of IR(infrared) analysis that the functional group of absorbent polymer would be changed from unidentate to bidentate during by the hydration of cement minerals.

  • PDF

균열보수용 폴리머 시멘트 복합체의 폴리머 종류에 따른 점도와 충전성에 관한 연구 (A Study on the Viscosity and Compaction of Polymer-Cement Composites According to Types of Polymer for Crack Repair)

  • 박동엽;권우찬;조영국
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.161-162
    • /
    • 2022
  • The purpose of this study is to determine the viscosity of the polymer-cement composites(PCCs) for crack repair of RC structures and to investigate its compaction. According to the study on the viscosity and compaction property of PCCs for crack repair, the viscosity of PCCs varies greatly depending on the polymer type and polymer cement ratio, and by mixing silica fume into PCCs, appropriate viscosity and excellent flow can be controlled without separation of cement and water. As a result of this study, basic data on the viscosity, fluidity, and compaction properties of PCCs for crack repair of RC structure can be obtained.

  • PDF

폴리머-콘크리트 복합재료 개발(I) - 폴리머-시멘트 콘크리트의 물성 - (Development of Polymer-Concrete Composite(I) - Physical Properties of Polymer-Cement Concrete Composites -)

  • 황의환;길덕수;오인석
    • 공업화학
    • /
    • 제8권6호
    • /
    • pp.979-984
    • /
    • 1997
  • 폴리머 혼화제로서 styrene-butadiene rubber(SBR)라텍스, ethylene-vinyl acetate(EVA)에멀젼 및 polyacrylic ester(PAE)에멀젼을 사용하여 동일한 스럼프에서 폴리머-시멘트비를 변화시켜 공시체를 제조하여, 압축과 휨강도시험, 흡수시험, 세공분포측정 및 미세구조 관찰 등을 실시하였다. 그 결과 폴리머-시멘트비의 증가와 더불어 압축과 휨강도 모두 향상되었고, 동해에 큰 영향을 주는 모세관 공극범위의 세공량은 감소되었으며, 폴리머 시멘트비 15wt% 이상에서 연속적인 폴리머필름이 형성되었다.

  • PDF

Effect of Formaldehyde on the Water Resistance of MDF Cement Composites

  • Nho, Jun-Seok;Park, Choon-Keun;Park, Sang-Heul
    • The Korean Journal of Ceramics
    • /
    • 제5권3호
    • /
    • pp.278-283
    • /
    • 1999
  • Formaldehyde has widely been used for the cross-linking of polyvinyl alcohol polyvinyl alcohol polymer. The effects of formaldehyde on the water resistance of MDF cement composites were investigated as a function of types of catalyst, base or acid, and the amount of formaldehyde. The acetalization, reaction of OH group of PVA with aldehyde, was ended incompletely under base atmosphere. However, by addition of citric acid, the cross-linking of PVA polymer could be acheved through acetalization of PVA and formaldehyde. The effects of these different patterne according to the types of catalyst on the water resistance of MDF cement were studied by the preparation of PVA films and MDF composites. Thanks to the cross-linking reaction of PVA polymer chains by formaldehyde, the modified PVA films and MDF composites showed a good water-resistant propety. The modified MDF cement composite to which 3 wt% formaldehyde and 1 wt% cirtic acid were added showed 80% of initial flexural strength and good interfacial state between cement grain and polymer matrix. However, 4 wt% formaldehyde deteriorted the processing conditions, microstructures and eventually the flexural strength, causing sharp increase in the viscosity of sample dough during the mixing process. To study the relatins of flexural strength and interface of cement grain and polymer matrix, SEM and MIP measurement were performed.

  • PDF

Mechanical Properties of Carbon-Fiber Reinforced Polymer-Impregnated Cement Composites

  • Park, Seung-Bum;Yoon, Eui-Sik
    • KCI Concrete Journal
    • /
    • 제11권3호
    • /
    • pp.65-77
    • /
    • 1999
  • A portland cement was reinforced by incorporating carbon fiber(CF), silica powder, and impregnating the pores with styrene monomers which were polymerized in situ. The effects of type, length, and volume loading of CF, mixing conditions, curing time and, curing conditions on mechanical behavior as well as freeze-thaw resistance and longer term stability of the carbon-fiber reinforced cement composites (CFRC) were investigated. The composite Paste exhibited a decrease in flow values linearly as the CF volume loadings increased. Tensile, compressive, and flexural strengths all generally increased as the CF loadings in the composite increased. Compressive strength decreased at CF loadings above approx. 3% in CFRC having no impregnated polymers due to the increase in porosity caused by the fibers. However, the polymer impregnation of CFRC improved all the strength values as compared with CFRC having no Polymer impregnation. Tensile stress-strain curves showed that polymer impregnation decreased the fracture energy of CFRC. Polymer impregnation clearly showed improvements in freeze-thaw resistance and drying shrinkage when compared with CFRC having no impregnated polymers.

  • PDF

RC 구조물의 균열 보수용 폴리머 시멘트 복합체의 접착특성에 관한 연구 (A Study on the Adhesion Properties of Polymer-Cement Composites for Repairing Cracks in RC Structures)

  • 조영국;홍대원;권우찬;김완기
    • 한국건축시공학회지
    • /
    • 제22권1호
    • /
    • pp.23-34
    • /
    • 2022
  • 본 연구의 목적은 RC 구조물의 균열 보수용 폴리머 시멘트 복합체의 접착성능을 평가하기 위함이다. 폴리머 시멘트 복합체는 시멘트, 폴리머와 실리카흄으로 제조하였으며, 점도가 700mPa·s 이하가 되도록 물시멘트비와 AE 감수제의 혼입량을 조정하였다. 연구결과, Type-A 인장접착강도는 폴리머계 마감 재료의 접착기준인 1.0MPa을 상회하였으며, 폴리머 종류에 따라 SAE, EVA, SBR 순으로 높은 인장접착강도를 나타냈다. 또한 Type-B의 인장접착강도는 Type-A에 비해 최대 1/4.5의 낮은 강도를 나타냈으나 실리카흄의 혼입에 따른 상당한 강도개선 효과를 보였다. RC 구조물의 균열 보수에 필요한 점도와 접착성능을 위해 EVA와 SAE의 폴리머 시멘트비 80%~100% 범위에서 일정량의 실리카 흄을 혼입하는 조건을 최적배합설계로 제안할 수 있었다.