• 제목/요약/키워드: polymer-based coating

검색결과 168건 처리시간 0.026초

Evaluation of Corrosion Resistance Properties of Hexagonal Boron Nitride Based Polymer Composite Coatings for Carbon Steel in a Saline Environment

  • Alabdullah, Fadhel T.;Ali, C.;Mishra, Brajendra
    • Corrosion Science and Technology
    • /
    • 제21권1호
    • /
    • pp.41-52
    • /
    • 2022
  • Herein, we report polyvinyl butyral composites coatings containing various loadings of 72-h bath sonicated hexagonal boron nitride particles (5 ㎛) to enhance barrier properties of coatings. Barrier properties of coatings were determined in 3.5 wt% NaCl after different time periods of immersion via electrochemical techniques such as open circuit potential, electrochemical impedance spectroscopy, and potentiodynamic polarization test. Coatings containing sonicated hexagonal boron particles exhibited improved corrosion resistance for longer periods of immersion compared to neat coating. We also discussed effects of hexagonal boron nitride on healing properties of polyvinyl butyral. Coatings containing 1.0 wt% loading of sonicated hexagonal boron nitride showed improved long-term barrier properties than coatings with other compositions. The presence of hexagonal boron nitride also affected the healing properties of polyvinyl butyral coatings besides their barrier properties. Such improved barrier properties of composites coatings were attributed to the high aspect ratio, plate-like shape, and electrically insulated nature of the filler.

분산코팅에 의해 형성된 Poly(vinylidene fluoride)와 Poly(methyl methacrylate) 블렌드 코팅층의 표면 특성 (Surface Characterization of Poly(vinylidene fluoride) and Poly(methyl methacrylate) Blend Coatings Prepared by Dispersion Coating)

  • 석광희;하종욱;이수복;박인준;김형중
    • 폴리머
    • /
    • 제37권2호
    • /
    • pp.177-183
    • /
    • 2013
  • 본 연구에서는 poly(ethylene terephthalate)(PET) 필름을 기재로 하여 분산코팅에 의해 형성된 poly(vinylidene fluoride)(PVDF)와 poly(methyl methacrylate)(PMMA) 블렌드 코팅의 표면 특성을 관찰하였다. 분산코팅의 특성상 저온에서 형성된 블렌드 코팅은 PVDF 입자의 형태와 결정구조가 그대로 유지되었으나 $120^{\circ}C$ 이상의 코팅온도에서 형성된 코팅의 경우 블렌드에 포함되어 있는 PVDF의 양에 따라 다양한 표면 특성을 나타내었다. 블렌드 중 PVDF의 양이 80 wt% 이상인 경우 PVDF의 ${\alpha}$-결정구조에 의한 특성이 확실히 관찰되는 반면에 PMMA의 양이 증가하면 표면 형태와 결정구조의 변화가 변화하는 것을 관찰하였다. 또한 코팅층의 최외각 표면에 대한 XPS 분석결과는 분산코팅에서도 PVDF의 표면 이행성이 나타남을 보여준다.

Protection Method for Diameter-downsized Fiber Bragg Gratings for Highly Sensitive Ultraviolet Light Sensors

  • Seo, Gyeong-Seo;Ahn, Tae-Jung
    • Current Optics and Photonics
    • /
    • 제2권3호
    • /
    • pp.221-225
    • /
    • 2018
  • We suggested the use of miniature hollow glass tubes having high ultraviolet (UV) transmission characteristics for the protection of optical-fiber-type UV sensors. We have recently proposed a highly sensitive optical sensor in the UV spectral range, using a fiber Bragg grating (FBG) coated with an azobenzene polymer as the photoresponsive material. In this study, we used UV-transparent miniature glass tubes to protect the etched FBG with the azobenzene polymer coating. This technique will be very useful for protecting various fiber-based UV sensors.

점진성형공구 코팅처리 및 소재에 따른 성형품 표면품질 분석 (Surface Quality of Products according to the Material and Coating Condition of the Forming Tool in Incremental Sheet Forming)

  • 윤형원;박남수
    • 소성∙가공
    • /
    • 제32권6호
    • /
    • pp.360-366
    • /
    • 2023
  • This study is concerned with the surface quality of products according to the material and coating condition of the forming tool in incremental sheet forming. Three forming tools, SKD11 with and without diamond-like-coating (DLC) and polymer tool tip, were used to form conical and pyramidal geometries to take into account the influence of friction between the forming tool and the sheet on the surface quality including geometric accuracy of deformed samples. Each test was performed using SUS304 with a thickness of 0.4 mm according to different incremental depths per lap of 0.5 mm, 1.0 mm, and 1.5 mm for the contour tool path, considering the increase in normal force which is associated with the frictional behavior during local deformation. The surface quality was then investigated through surface roughness measured with KEYENCE VR-6000 and relative strain distribution including deformed shape analyzed with ARGUS which is a non-contact optical strain measurement system. Differences between 3D CAD surfaces and captured geometry from experiments were evaluated to compare the effect of friction on geometric accuracy. From comparisons of experimental results, it was revealed that the polymer-based tool tip can improve surface quality and geometric accuracy by reducing the undesired material flow due to local friction in the increment sheet forming process.

Effect of Curing and Compression Process on the Drug Release of Coated Ion-Exchange Resin Complexes

  • Jeong, Seong-Hoon;Wang, Hun-Sik;Koo, Ja-Seong;Choi, Eun-Joo;Park, Ki-Nam
    • Journal of Pharmaceutical Investigation
    • /
    • 제41권2호
    • /
    • pp.67-73
    • /
    • 2011
  • Ion exchange resins can be one of the good carriers for sustained drug release. However, the sustained release may not be enough only with themselves and hence film coating with rate controlling polymers can be applied to have a further effect on the drug release. Due to the environmental and economic issues of organic solvent for the polymer coating, aqueous polymeric systems were selected to develop dosage forms. Among the many aqueous polymeric dispersions for the film coating, EC (ethylcellulose) based polymers such as Aquacoat$^{(R)}$ ECD and Surelease$^{(R)}$ were evaluated.A fluid-bed coating was applied as a processing method. The drug release rate was quite dependent on the coating level so the release rate could be modified easily by changing different levels of the coating. The drug release rate in the Aquacoat$^{(R)}$ coated resin particles was strongly dependent on curing, which is a thermal treatment to make homogeneous films and circumvent drug release changes during storage. After dissolution test using the compressed tablets in which the coated resin particles are contained, inhomogeneous coating and even pores could be observed showing that the mechanical properties of EC were not resistant to granulation and compaction process. However, when tablets were prepared in different batches, the release profiles were almost identical showing the feasibility of the coated resin particle as incorporated into the tablet formulation.

Thermosensitive Hydrogels Based on IPNs and Emulsion Blends of Poly (N-isopropylacrylamide) and Polyurethane

  • Cho, Sung-Man;Kim, Byung-Kyu
    • 한국고분자학회:학술대회논문집
    • /
    • 한국고분자학회 2006년도 IUPAC International Symposium on Advanced Polymers for Emerging Technologies
    • /
    • pp.374-374
    • /
    • 2006
  • Poly (N-isopropylacrylamide) (PNIPAAm) shows a lower critical solution temperature (LCST) at $32^{\circ}C$. Consequently, its thermosensitivity has extensively been investigated in coating materials as well as biomedical and agricultural industry. However, mechanical properties of the swollen gels are generally poor and reinforcement is often desired. A series of interpenetrating polymer networks (IPNs) and emulsion blends hydrogels of polyurethane (PU) and PNIPAAm were prepared in order to overcome the shortcomings of a normal PNIPAAm hydrogels. Regarding the mechanical reinforcement of swollen gel, a significant increase in compression and tensile properties has been obtained by incorporating PU.

  • PDF

Application of poly(vinyl acetate) and poly(1,4-butylene adipate) hydrophobic surface coatings on cementitious mortar specimens

  • Sanal, Irem;Yalcin, Bestenur;Yalcin, Ibrahim Ertugrul;Arda, Lutfi
    • Advances in concrete construction
    • /
    • 제11권4호
    • /
    • pp.323-333
    • /
    • 2021
  • The main objective of this study is to characterize and evaluate the hydrophobic performance of polymer-based water-repellent coatings on cementitious mortar surfaces. Different concentrations of poly(vinyl acetate) (PVAc) and poly(1,4-butylene adipate) (PBA) were prepared in the laboratory and their applicability and performance was tested experimentally by water absorption test and analysis of surface contact angles of cementitious mortar specimens. According to the results of this study, it can be stated that incorporation of nano polymer particles on the surface of cementitious mortar specimens can enhance contact angles and reduce water absorption by increasing hydrophobicity. However, a dosage limit exists for polymer materials in coating, and observed hydrophobic improvements decreases when polymer dosage reached beyond the limit. Additionally, it is observed that water absorption of polymer coated cementitious mortars is closely related with the results of surface contact angle.

THE EFFECTS OF SEALING ON THE PLASMA-SPRAYED OXIDE-BASED COATINGS

  • Kim, Hyung-Jun;Sidoine Odoul;Kweon, Young-Gak
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.53-58
    • /
    • 2002
  • Electrical insulation and mechanical properties of the plasma sprayed oxide ceramic coatings were studied before and after the sealing treatment of the ceramic coatings. Plasma sprayed A1$_2$O$_3$-TiO$_2$ coating as the reference coating was sealed using three commercial sealants based on polymer. Penetration depth of the sealants to the ceramic coating was evaluated directly from the optical microscope using a fluorescent dye. It is estimated that the penetration depth of the sealants to the ceramic coating is from 0.2 to 0.5 mm depending on the sealants used. The preliminary test results with a DC puncture tester imply that the dielectric breakdown voltage mechanism of plasma sprayed ceramic coatings has been determined to be a corona mechanism. Dielectric breakdown voltage of the as-sprayed and as-ground samples have shown a linear trend with regard to the thickness showing an average dielectric strength of 20 kV/mm for the thickness scale studied. It is also shown that grinding the coating before sealing and adding fluorescent dye do not agent the penetration depth of sealants. All of the microhardness, two-body abrasive wear resistance, bond strength, and surface roughness of the ceramic coating after the sealing treatment are improved. The extent of improvement is different from the sealants used. However, three-point bending stress of the ceramic coating after the sealing treatment is decreased. This is attributed to the reduced micro-crack toughening effect since the cracks propagate easily through the lamellar of the coating without crack deflection and/or branching after the sealing treatment.

  • PDF

옥타데실트리클로로실란 코팅에 의한 실리콘 표면 특성 변화 (Surface Characteristics of Silicon Substrates Coated with Octadecyltrichlorosilane)

  • 유희재;김수경;김진홍;강호종
    • 폴리머
    • /
    • 제27권6호
    • /
    • pp.555-561
    • /
    • 2003
  • 미세전자기계 시스템에 사용되는 실리콘 기판의 표면 특성 조절을 위하여 옥타데실트리클로로실란 (OTS)을 실리콘에 자기조립 단분자층 (SAMs)으로 형성시켜, 코팅 조건 및 코팅 용액 조성에 따른 표면특성 변화를 살펴보았다. OTS와의 솔-젤 반응을 위하여 실리콘 표면을 sulfuric peroxide mixture (SPM) 용액으로 처리한 결과, 실리콘 표면에 -OH기가 형성되어 친수성이 증가됨을 알 수 있었으며 상온에서 황산의 비가 85%인 SPM 용액에서 솔-젤 반응을 위한 최적의 산화막이 형성됨을 알 수 있었다. SPM 처리에 의하여 발현된 실리콘 표면의 -OH기는 솔-젤 반응에 의하여 OTS의 -CI와 반응하여 Si-O 화학결합을 형성하며 이에 따라 표면은 소수성으로 변화됨을 확인할 수 있었다 이 때 코팅 온도 및 시간 그리고 용액의 조성은 솔-젤 반응에 영향을 미쳐 SAMs표면의 소수성을 조절하는 인자로 작용하였다.

Epitaxial Growth of Polyurea Film by Molecular Layer Deposition

  • 최성은;강은지;이진석
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.264.2-264.2
    • /
    • 2013
  • Molecular layer deposition (MLD) is sequential, self-limiting surface reaction to form conformal and ultrathin polymer film. This technique generally uses bifunctional precursors for stepwise sequential surface reaction and entirely organic polymer films. Also, in comparison with solution-based technique, because MLD is vapor-phase deposition based on ALD, it allows epitaxial growth of molecular layer on substrate and is especially good for surface reaction or coating of nanostructure such as nanopore, nanochannel, nanwire array and so on. In this study, polyurea film that consisted of phenylenediisocyanate and phenylenediamine was formed by MLD technique. In situ Fourier Transform Infrared (FTIR) measurement on high surface area SiO2 substrate was used to monitor the growth of polyurethane and polyurea film. Also, to investigate orientation of chemical bonding formed polymer film, plan-polarized grazing angle FTIR spectroscopy was used and it showed epitaxial growth and uniform orientation of chemical bones of polyurea films.

  • PDF