• Title/Summary/Keyword: polyamide membrane

Search Result 89, Processing Time 0.026 seconds

Fabrication of Reverse Osmosis Membrane with Enhanced Boron Rejection Using Surface Modification (표면개질을 이용하여 붕소 제거율이 향상된 역삼투막의 제조)

  • Lee, Deok-Ro;Kim, Jong Hak;Kwon, Sei;Lee, Hye-Jin;Kim, In-Chul
    • Membrane Journal
    • /
    • v.28 no.2
    • /
    • pp.96-104
    • /
    • 2018
  • With the rapid increase in seawater desalination, the importance of boron rejection is rising. This study was conducted to investigate the effect of hydrophilic compounds on surface modification to maximize water flux and increase boron rejection. First, polyamide active layer was fabricated by interfacial polymerization of polysulfone ultrafiltration membrane with M-phenylenediamine (MPD) and trimesoyl chloride (TMC) to obtain Control polyamide membrane. Next, D-gluconic acid (DGCA) and D-gluconic acid sodium salt (DGCA-Na) were synthesized with glutaraldehyde (GA) and hydrochloric acid (HCl) by modifying the surface of Control polyamide membrane. XPS analysis was carried out for the surface analysis of the synthesized membrane, and it was confirmed that the reaction of surface with DGCA and DGCA-Na compounds was performed. Also, FE-SEM and AFM analysis were performed for morphology measurement, and polyamide active layer formation and surface roughness were confirmed. In the case of water flux, the membrane fabricated by the surface modification had a value of 10 GFD or less. However, the boron rejection of the membranes synthesized with DGCA and DGCA-Na compounds were 94.38% and 94.64%, respectively, which were 12.03 %p and 12.29 %p larger than the Control polyamide membrane, respectively.

Hypochlorite treatment of polyamide membrane for improved reverse osmosis performance

  • Shao, P.;Kurth, C.J.
    • Membrane and Water Treatment
    • /
    • v.4 no.1
    • /
    • pp.69-81
    • /
    • 2013
  • The pH-dependent inter-conversion of the three free chlorine species ($Cl_2$, HOCl, OCl-) present in the aqueous hypochlorite solution was theoretically investigated. Each species was found overwhelmingly present in a characteristic pH range. Hypochlorite treatment of the polyamide membrane was carried out over these pH ranges and various membrane responses were observed. As pH is less than 8, membrane tends to be N-chlorinated by $Cl_2$ and HOCl, and N-chlorinated membrane showed reduced water permeance and salt rejection. As pH rises to 10-12, $OCl^-$ appears to be the dominating chlorine species. Membrane hydrolysis was found to well interpret the improved water permeance and salt rejection. When the pH is between 8-10, both N-chlorination and hydrolysis contribute to the response of the membrane, and the treated membrane showed improved salt rejection but reduced water permeation. Excessive hydrolysis occurred while the membrane was treated at pH 13 for the much stronger alkalinity.

A Study on Chlorine Resistance Improvement of Reverse Osmosis Membrane by Surface Modification (역삼투 분리막의 표면개질을 이용한 내염소성 향상에 관한 연구)

  • Kim, Younggil;Kim, Nowon;Lee, Yong-Taek
    • Membrane Journal
    • /
    • v.15 no.4
    • /
    • pp.320-329
    • /
    • 2005
  • Polyamide membrane degradation by chlorine has been studied to improve membrane durability. In this study, it was found that the salt rejection was reduced rapidly and flux of the membrane was increased slowly far membrane treated under chlorine condition. In order to improve resistance to chlorine of the polyamide reverse osmosis membrane, fluorine-containing silane coupling agent (FSCA) was introduced to surface modification. Surface properties and chlorine resistance of silane modified membrane were compared with virgin membrane. It was found that the surface of silane modified membrane has dense structure according to FSCA concentration increasing. The results of surface analysis suggest that FSCA retrieved a severe change in the hydrophobicity and surface roughness. In addition, it appears that FSCA can enhance chlorine resistance due to the interaction of such substance with free radical chlorine.

Nanofiltration of Dye Solutions Through Polyamide Composite Membranes

  • Jonggeon Jegal;Baek, Kyung-Sook;Lee, Kew-Ho
    • Korean Membrane Journal
    • /
    • v.4 no.1
    • /
    • pp.12-19
    • /
    • 2002
  • Nanofiltration of aqueous dye solutions was carried out using polyamide (PA) nanofiltration (NF) composite membranes. The PA composite membranes were prepared by the interfacial polymerization of piperazine (PIP) and trimesoyl chloride (TMC) on the surface of microporous polysulfone (PSf) ultrafi1tration (UF) membranes. After characterization in terms of their permeation performance and surface ionic property, they were used for the separation of dye solutions such as Direct Red 75, 80, 81, and Direct Yellow 8 and 27. The separation conditions were varied to study the factors affecting on the permeation performance of the membranes: different concentrations of dye solutions, operating temperature and time, and flow rate of a feed solution. The surface property of the membrane, especially its ionic property, as a function of operating time was examined with a zeta-potentiometer and the relationship between the surface chemistry of the membrane and its permeation properties was also studied.

Combined Effects of Metal Coagulants and Monochloramine on Polyamide RO Membrane Performance (금속성 응집제와 모노클로라민의 상호작용이 Polyamide계 RO막 성능에 미치는 영향)

  • Kim, Kyunghwa;Hong, Seungkwan;Park, Chanhyuk;Yoon, Seongro;Hong, Seongpyuo;Lee, Jonghwa
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.4
    • /
    • pp.637-643
    • /
    • 2006
  • The bench-scale chlorine exposure study was performed to investigate the effect of pretreatment by free chlorine and monochloramine ($NH_2Cl$) on the performance of RO membranes made of polyamide (PA). Feed monochloramination at 2mg/L did not cause significant productivity loss compared to free chlorine. However, metal coagulants reacted with monochloramine, the PA membrane suffered from a gradual loss of membrane integrity by chlorine oxidation, which was characterized as a decrease in salt rejection. Especially, RO membranes exposed to alum coagulants with monochloramine revealed the salt rejection lower than those exposed to iron coagulants. XPS membrane surface analysis demonstrated that the chlorine uptake on the membrane surface increased and carbon peaks were shifted significantly when exposed to alum coagulants with monochloramine.

Preparation of poly(vinyl alcohol)-coated Composite Nanofiltration Membranes on Various Support Membranes (다양한 지지체 분리막 위에 poly(vinyl alcohol)이 코팅된 나노복합막의 제조)

  • Lee Kew-Ho;Kim In-Chul
    • Membrane Journal
    • /
    • v.15 no.1
    • /
    • pp.34-43
    • /
    • 2005
  • The poly(vinyl alcohol) (PVA)-based thin film composite nanofiltration (NF) membranes were prepared by coating polysulfone ultrafiltration membranes, sulfonated polyethersulfone and polyamide NF membranes with aqueous PVA solution by a pressurizing method. The PVA was cross-linked with aqueous glutaraldehyde solution. The NF membranes coated with a very low concentration of PVA on all the support membranes was successfully prepared. With increasing the hydrophilicity of the support membranes, the water flux increased. Especially, ζ-potential of negatively charged polyamide NF membrane was reduced by coating the membrane with PVA. A fouling experiment was carried out with positively charged surfactant, humic acid, complex of humic acid and calcium ion and bovine serum albumin. A non-coated polyamide NF membrane was significantly fouled by various foulants. The fouling process when using humic acid and protein occurred at the isoelectric point. There was severe fouling when using humic acid and adding bivalent cations. By coating the polyamide NF membrane with aqueous PVA solution, fouling was reduced. The polyamide NF membrane coated with PVA was resistant to the acidic and basic solution.

Phenol removal by tailor-made polyamide-fly ash composite membrane: Modeling and optimization

  • Vandana, Gupta;Anandkumar, J.
    • Membrane and Water Treatment
    • /
    • v.10 no.6
    • /
    • pp.431-440
    • /
    • 2019
  • A novel composite membrane was synthesized using crosslinked polyamide and fly ash ceramic substrate for phenol removal. Glutaraldehyde was used as crosslinker. Characterization shows that synthesized membrane possesses good permeability ($0.184l.m^{-2}.h^{-1}.kPa^{-1}$), MWCO (1.7 kDa), average pore size (1.08 nm) and good chemical stability. RSM was adopted for phenol removal studies. Box-Behnken-Design using quadratic model was chosen for three operating parameters (feed phenol concentration, pH and applied pressure) against two responses (phenol removal, flux). ANOVA shows that model is statistically valid with high coefficient of determination ($R^2$)value for flux (0.9897) and phenol removal (0.9302). The optimum conditions are obtained as pH 2, $46mg.l^{-1}$ (feed phenol concentration) and 483 kPa (applied pressure) with 92.3% phenol removal and $9.2l.m^{-2}.h^{-1}$ flux. Data validation with deviation of 4% confirms the suitability of model. Obtained results reveal that prepared composite membrane can efficiently separate phenol from aqueous solution.

Nanofiltration of Dyeing Wastewater Using Polyamide Ro-Membranes after the Pretreatment with Chemical Coagulants

  • Hwang Jeong-Eun;Jegal Jonggeon;Mo Joonghwan;Kim Jaephil
    • Korean Membrane Journal
    • /
    • v.7 no.1
    • /
    • pp.58-66
    • /
    • 2005
  • Nanofiltration (NF) of a dyeing wastewater was carried out using polyamide NF-membranes. Before applying the wastewater to the membrane process, it was pretreated with various chemical coagulants such as alum, ferric chloride and HOC-100A. In order to see the effect of the pretreatment of the wastewater using chemical coagulants on the membrane separation process, the optimum conditions for the coagulation and sedimentation process using the chemical coagulants were sought. By the pretreatment, despite the different coagulants used, the chemical oxygen demand (COD) and UV-absorbance of the wastewater were lowered by more than $70\%$. The pretreated wastewater was then applied to the membrane process. The effect of the coagulants used for the pretreatment on the membrane fouling was studied. From this study, it was found that the HOC-100A was the best out of the coagulants used far the removal of the materials that could cause membrane fouling.

Interpretation of Permeation Characteristics and Membrane Transport Models Through Polyamide Reverse Osmosis Membrane (Polyamide 역삼투막의 투과성능과 막 이동 모델의 해석)

  • 김노원;김영길;이용택
    • Membrane Journal
    • /
    • v.14 no.1
    • /
    • pp.75-84
    • /
    • 2004
  • In this study, we present a noble study far membrane transport models using chlorine resistance of polyamide RO membranes. Membrane transport mechanism is investigated by the comparison of membrane permeation performance under the continuous and Intermittent operation modes with mixed feed solution containing NaOCl and NaCl. Analysis of permeation performance indicates that solution-diffusion model and preferential adsorption-capillary flow model are relatively efficient according to operation mode. Under the continuous flow state, mass transfer depends on preferential adsorption-capillary flow model rather than solution-diffusion model. On the other hand, it prefers solution-diffusion model to preferential adsorption-capillary flow model under the stationary state. SEM images of NaOCl treated membrane surfaces strongly support these conclusions. These surface images reveal that NaOCl treated membrane in continuous operation mode exhibits ridge and valley structure in some fraction of the surface area, whereas that in intermittent operation mode shows surface degradation entirely.

Introduction of vinyl Compounds Containing Hydroxyl Group into Polyamide Reverse Osmosis Membrane

  • 염민오;김학상;김성수;김재진
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.10a
    • /
    • pp.54-55
    • /
    • 1995
  • 현재 수처리용 분리막으로 널리 사용되고 있는 상업용 polyamide membrane은 주사슬을 이루고 있는 amide bond가 chlorine에 쉽게 분해됨으로써 주쇄의 절단이 일어나므로 막이 파괴되는 결과를 초래하여 역삼투 분리막의 기능이 저하되는 문제점을 갖고 있다. 또한 분리막의 성능으로써 수투과도의 향상도 기존의 분리막의 개선점으로 지적되고 있다. 본 연구에서는 재료 자체의 친수성이 강한 hydroxyl group을 가진 vinyl계 화합물을 기존의 amine계 monomer와 혼합하여 가교반응을 시킴으로써 전체적인 분리막의 수투과도 및 내염소성의 향상을 도모하였다. 기존의 polyamide 분리막의 소재인 1,3-phenylenediamine(MPDA)에 친수성기인 hydroxyethylmethacrylate(HEMA) monomer를 첨가하고 가교제인 trymesoyl chloride(TMC)로 이를 가교시켜 HEMA 및 PVA의 친수성에 의한 수투과도 및 내염소성의 향상을 유도하여 보았다.

  • PDF