• 제목/요약/키워드: polyacrylate fiber

검색결과 9건 처리시간 0.02초

SPME-GC-MS를 이용한 DBCP 및 n-Butylbenzene의 분석 (Determination of DBCP and n-Butylbenzene using SPME with GC-MS)

  • 박현미;김영만;이대운;이강봉
    • 분석과학
    • /
    • 제14권6호
    • /
    • pp.471-475
    • /
    • 2001
  • $85{\mu}m$-polyacrylate(PA) 와 $100{\mu}m$-polydimethylsiloxane(PDMS) fiber를 사용하여 물증의 DBCP와 n-butylbenzene을 추출한 후 GC-MS로 분석하는 방법을 연구하였다. SPME 과정에 영향을 미치는 인자들, 즉 추출 시간, 주입 길이, 주입 온도, 탈착 시간 및 탈착 온도들에 대한 최적화 조건을 조사하였다. 검량선의 직선성(correlation coefficient, R)은 0.99 이상이었으며, 본 분석법의 검출한계는 1.5 와 $10.8{\mu}g/L$ 이었고, 분석법의 재현성은 RSD 10.4와 14.4 % 였다.

  • PDF

HS-SPME-GC/MS에 의한 혈액중 17종 유기인계 농약의 동시분석법 (Simultaneous Analysis of 17 Organophosphorous Pesticides in Blood by Automated Head Space-SPME GC/MS)

  • 이종숙;정진미;이한선;염혜선;이상기;박유신;정희선
    • 약학회지
    • /
    • 제54권6호
    • /
    • pp.429-440
    • /
    • 2010
  • HS-SPME-GC/MS was studied and optimized for the determination of 17 orgarnophosphorous pesiticides (OPPs: chlorpyrifos, chlorpyrifos-methyl, demeton-s-methyl, diazinon, dimethoate, EPN, fenitrothion, fenthion, malathion, methidathion, monocrotophos, parathion, phenthoate, phosphamidon, sulfotep, terbufos, triazophos) in blood. Optimum SPME parameters were selected: choice of SPME fiber (85 ${\mu}m$ polyacrylate), pH effect (0.5 N HCl), salt effect ($Na_2SO_4$, 0.2 g; 20%), headspace incubation temperature ($80^{\circ}C$), headspace incubation time (1 min), headspace adsorption time (30 min) and GC desorption time (2 min). These parameters were optimized using HS-SPME autosampler coupled with gas chromatography-mass spectrometry (GC-MS). Method validation was carried out in terms of linearity, limit of detection (LOD), limit of quantitation (LOQ) and recovery in blood. The assay was linear over 0.5~5.0 mg/l ($r^2$=0.955~1.000). Limit of detection (LOD) and limit of quantitation (LOQ) in blood were determined 0.03~0.3 mg/l (S/N=3) and 0.1~1.1 mg/l (S/N=10), respectively. Relative recovery with 0.5, 1 and 5 mg/l (in blood) were 90.8%, 98.5% and 94.1%, respectively. This method will be applied to the determination of the orgarnophosphorous pesticides in postmortem blood. The proposed protocol can be an attractive alternative to be used in routine toxicological analysis.

HS SPME-GC/MS를 이용한 혈액 중 유기염소계 농약의 분석법 개발 (Development of an analytical method of organochlorine pesticides in human bloods using head space-solid phase microextraction coupled with gas chromatography/mass spectrometry)

  • 강태우;표희수;홍종기
    • 분석과학
    • /
    • 제21권4호
    • /
    • pp.259-271
    • /
    • 2008
  • 혈액 내에 축적되어 있는 유기염소계 농약을 분석하기 위한 방법으로 기존에는 액체-액체 추출법과 고체상 추출법을 많이 사용하였으나 정제 및 많은 양의 시료 처리에 한계가 있다. 이를 극복하기 위한 방법으로 시료양이 적으며 간편한 고체상미량추출법을 사용하여 혈액 중 18종의 유기염소계 농약의 최적 추출법을 연구하였다. 흡착조건(fiber type, 흡착시간, 흡착온도, 염석효과)과 탈착조건(탈착시간, 탈착온도) 등 최적의 추출을 위해 여러 가지의 실험조건 등을 검토한 결과, fiber는 polyacrylate $85{\mu}m$, 흡착시간은 50분, 흡착온도는 $80^{\circ}C$, 염석효과는 NaCl 0.1 g, 탈착시간은 5분, 탈착온도는 $280^{\circ}C$에서 최적임을 확인하였다. 정확도, 정밀도 및 검출한계에 대한 타당성을 최적 실험조건에서 조사한 결과, 검출한계는 0.05~0.20 ng/mL, 정밀도는 5.59~13.39%, 정확도는 -0.5%~24.5%의 범위인 것으로 확인되었다.

레이온/폴리에틸렌옥사이드 분리막과 하이드로겔 전해질이 적용된 활성탄 수퍼커패시터 특성 (Electrochemical Properties of Activated Carbon Supercapacitor Adopting Rayon/Poly(Ethylene Oxide) Separator and a Hydrogel Electrolyte)

  • 이해수;김광만;장윤석;김광영;유정준;김종휘;고장면
    • 전기화학회지
    • /
    • 제18권3호
    • /
    • pp.115-120
    • /
    • 2015
  • Rayon 분리막에 poly(ethylene oxide) (PEO)를 코팅하고 potassium polyacrylate (PAAK)-KOH 하이드로겔 전해질을 사용하여 기계적 강도 및 전기화학적 성질을 시험하였고, 이를 활성탄 수퍼커패시터에 적용하여 커패시터 특성을 조사하였다. PEO 코팅량의 증가에 따라 기계적 강도는 증가하였으며, PEO 함량을 5 wt.% 이하로 유지하면 이온전도도가 $10^{-2}S\;cm^{-1}$ 이상을 유지하여 실제 커패시터에의 활용이 가능하였다. 결과적으로 Rayon/PEO 분리막과 PAAK/KOH 전해질을 적용한 활성탄 수퍼커패시터는 $1000mV\;s^{-1}$의 높은 스캔속도에서도 비축적용량이 1000 사이클까지 안정하게 나타나는데, 이는 PEO 코팅이 Rayon의 장섬유 필라멘트간 엉킴점을 고정시켜 고출력 안정성을 얻을 수 있기 때문이다.

Synthesis and Characterization of Sodium Acrylate and 2-Acrylamido-2- Methylpropane Sulphonate (AMPS) Copolymer Gels

  • Jassal, Manjeet;Chattopadhyay, Ritwik;Ganguly, Debojyoti
    • Fibers and Polymers
    • /
    • 제5권2호
    • /
    • pp.95-104
    • /
    • 2004
  • A series of superabsorbents based on acrylic acid (AA), sodium acrylate, 2-acrylamido-2-methylpropane sulphonic acid, N,N'-methylene bis-acrylamide (MBA) were prepared by inverse suspension polymerization. These hydrogels were further crosslinked on the surface with polyethylene glycol-600 (PEG-600). The water absorbency or swelling behaviors for these xerogels in water and 0.9% saline solutions, both under free condition and under load were investigated. Absorption characteristics of these hydrogels were found to depend on nature and concentration of crosslinker in the system. It was also found that the saline absorption was significantly improved as the incorporation of AMPS in the polymer was increased. The surface crosslinking introduced in the polymers was found to improve the absorption under load characteristics without lowering the free water absorption capacities of the polymer to a considerable extent.

Optimization of Headspace Sampling Using Solid Phase Microextraction For Volatile Organic Acids in Different Tobacco Types

  • Lee, Jang-Mi;Lee, Jeong-Min;Son, Seong-Ae;Kwon, Young-Ju;Jang, Gi-Chui;Kim, Young-Ho
    • 한국연초학회지
    • /
    • 제35권1호
    • /
    • pp.7-12
    • /
    • 2013
  • A Solid-phase micro extraction(SPME) was evaluated as a tool for headspace sampling of tobacco samples. Several experimental parameters (sampling temperature, pH, and type of SPME fibers) were optimized to improve sampling efficiency in two aspects ; maximum adsorption and selective adsorption of volatile organic acids onto SPME fibers. Among four types of SPME fibers such as PDMS(Polydimethylsiloxane), PA(Polyacrylate), Car/PDMS (Carboxen/Polydimethylsiioxane) and PDMS/DVB(Polydimethylsiioxane/Divinylbenzene) which were investigated to determine the selectivity and adsorption efficiency. A variety of tobacco samples such as flue cured, burley and oriental were used in this study. The effect of these parameters was often dominated by the physical and chemical nature (volatility, polarity) of target compounds. This method allowed us to make important improvements in selectivity and sensitivity. The Car/PDMS fiber was shown to be the most efficient at extracting the 10 selected volatile organic acids. The parameters were optimized: $80^{\circ}C$ adsorption temperature, 30 min of adsorption time, $240^{\circ}C$ desorption temperature, 1 min of adsorption time.

Analysis of Agrochemical Residues in Tobacco Using Solid Phase Microextraction-Gas Chromatography with Different Mass Spectrometric Techniques

  • Lee, Jeong-Min;Jang, Gi-Chul;Kim, Hyo-Keun;Hwang, Geon-Joong
    • 한국연초학회지
    • /
    • 제30권2호
    • /
    • pp.117-124
    • /
    • 2008
  • A solid phase microextraction (SPME) method in combination with gas chromatography/mass spectrometric techniques was used for the extraction and quantification of 12 selected agrochemical residues in tobacco. The parameters such as the type of SPME fiber, adsorption/desorption time and the extraction temperature affecting the precision and accuracy of the SPME method were investigated and optimized. Among three types of fibers investigated, polyacrylate (PA), polydimethylsiloxane (PDMS) and polydimethylsiloxane-divinylbenzene (PDMS-DVB), PDMS fiber was selected for the extractions of the agrochemicals. The SPME device was automated and on-line coupled to a gas chromatograph with a mass spectrometer. Mass spectrometry (MS) was used and two different instruments, a quadrupole MS and triple quadrupole MS-MS mode, were compared. The performances of the two GC-MS instruments were comparable in terms of linearity (in the range of 0.01$\sim$0.5 $\mu$g/mL) and sensitivity (limits of detection were in the low ng/mL range). The triple quadrupole MS-MS instrument gave better precision than that of quadrupole MS system, but generally the relative standard deviations for replicates were acceptable for both instruments (< 15%). The LODs was fully satisfied the requirements of the CORESTA GRL. Recoveries of 12 selected agrochemicals in tobacco yielded more than 80% and reproducibility was found to be better than 10% RSD so that SPME procedure could be applied to the quantitative analysis of agrochemical residues in tobacco.

SPME-GC-MS를 이용하여 풍선에 포함된 가소제의 분석 (Determination of Plasticizers included in Balloon by Solid Phase Microextraction and Gas Chromatography with Mass Spectrometric Detection)

  • 박현미;김지현;류재천;김영만;이강봉
    • 분석과학
    • /
    • 제14권1호
    • /
    • pp.44-49
    • /
    • 2001
  • GC-MS와 연결된 $85{\mu}m$ 폴리 아크릴레이트 fiber의 SPME가 풍선 시료 중에 포함된 가소제를 분석하는데 사용되었다. 풍선은 IR 분광법에 의해 폴리이소프렌으로 만들어진 것으로 판명되었다. 한시간 동안 아세톤이 첨가된 물 용매에서 추출된 풍선의 가소제는 9종류의 가소제가 포함된 외부표준법에 의해 정량 하였다. 정량법은 $0.25-25{\mu}g/g$의 농도범위에서 표준 가소제들에 대하여 유효화 과정을 거쳤으며, 검출한계는 가소제에 따라 $0.11-0.38{\mu}g/g$이었고, 이러한 정량법에 의한 재현성의 RSD는 3.7-14.2%이었다. 이들 풍선 중에는 우려할만한 수준의 환경호르몬성 가소제가 검출되는 제품도 포함되어 있어 이들에 대한 규제의 필요성이 있다.

  • PDF

추출방법에 따른 잎담배 종류별 휘발성 향기성분 특성비교 (Comparison of the volatile flavor compounds in different tobacco types by different extraction methods)

  • 이장미;이정민;이창국;복진영;황건중
    • 한국연초학회지
    • /
    • 제32권2호
    • /
    • pp.77-87
    • /
    • 2010
  • Traditional simultaneous distillation extraction(SDE) and solid-phase micro extraction(SPME) methods using GC/MS were compared for their effectiveness in the extraction of volatile flavor compounds from different tobacco leaves types(flue-cured, burley, oriental). The major volatile flavor compounds of flue-cured and burley tobacco were similar such as neophytadiene, solanone, megastigmatrienone isomers, ${\beta}$-damascenone and ${\beta}$-ionone. On the other hand, volatile flavor compounds such as norambreinolide, sclareolide were specifically identified in oriental tobacco. Each method was used to evaluate the responses of some analytes from real samples and standards in order to provide sensitivity comparisons between two techniques. Among three types of SPME fibers such as PDMS(Polydimethylsiloxane), PA(Polyacrylate) and PDMS/DVB (Polydimethylsiloxane/Divinylbenzene) which were investigated to determine the selectivity and adsorption efficiency, PDMS/DVB fiber was selected for the extractions of the volatile flavor compounds due to its effectiveness. The qualitative analysis showed that the total amount of volatile flavor compounds in SDE method(130 species) was much more than that in SPME method(85 species). SPME method was more efficient for all the highly volatile compounds than SDE method, but on the other hand, low-volatile compounds such as fatty acids or high-molecular hydrocabons were detected in SDE method. SPME method based on a short-time sampling can be adjusted to favor a selected group compounds in tobacco. Furthermore this results could be used to estimate the aroma characteristics of cigarette blending by using a different type of tobacco with more effectiveness and convenience.