• 제목/요약/키워드: pollutant source

검색결과 638건 처리시간 0.03초

A Study on the Discharge of Volatile Organic Compounds in Indoor Air of Newly-constructed Apartment Houses

  • Ryu, Jung-Min;Jang, Seong-Ki;Yang, Won-Ho;Cho, Tae-Jin;Son, Bu-Soon
    • 한국환경과학회지
    • /
    • 제18권5호
    • /
    • pp.479-487
    • /
    • 2009
  • Because of the building is made airtight, Indoor Air Quality(IAQ) is go from bad to worse. There are many source of indoor pollution in any home. These include irritation of the eyes, nose, and throat, headaches, dizziness, and fatigue. Such immediate effects are usually short-term and treatable. In this study was measured and analyzed VOCs exposure levels and characteristic of Indoor air pollutant from new apartments in Korea. VOCs were measured indoor pre-residential and residential in new apartment and analyzed GC/MS. The concentration levels of indoor respirable TVOC were found to be higher than those of outdoor TVOC for new apartments. Before occupation, the average indoor and outdoor concentrations were 1498.61 $ug/m^3$ and 468.38 $ug/m^3$, respectively. After being occupied, the average indoor and outdoor concentration were 847.04 $ug/m^3$ and 102.84, respectively. The concentrations of TVOC in new apartments before occupation were shown in the order of Toluene(328.12 $ug/m^3$) > m,p-Xylene(163.67 $ug/m^3$) > Ethy1benzene(80.70 $ug/m^3$>o-XYlene (67.04$ug/m^3$). In addition, the TVOCs concentrations after occupation were also found in the order of Toluene (272.28 $ug/m^3$) > m.p-Xylene(121.79 $ug/m^3$) > Ethylbenzene(53.92 $ug/m^3$)>O-Xylene(24.94 $ug/m^3$). As a result, the concentrations of VOCs in new apartment houses were shown to be affected by indoor environment according activity patterns. So new apartments need to be controled in indoor air quality so that the residents can have more comfortable and healthier living environment.

자동차를 통한 대기오염물질의 배출에 따른 민법상 불법행위책임의 성립 여부: 대법원 2014. 9. 4. 선고 2011다7437 판결을 중심으로 (Review of a Tort Case regarding Liability for the Production of Air Pollutant-emitting Vehicles: Supreme Court Decision 2011Da7437, Decided on September 4, 2014)

  • 이선구
    • 한국환경보건학회지
    • /
    • 제42권6호
    • /
    • pp.375-384
    • /
    • 2016
  • Objectives: This paper analyzes the intersection of tort law and environmental health in a recent court decision. Methods: This paper analyzes Supreme Court Decision 2011Da7437, Decided on September 4, 2014 and related lower court decisions. Results: The plaintiffs sought financial compensation from the defendants, arguing that air pollutants in gases emitted by vehicles produced by the defendants had caused them to acquire respiratory diseases. The district court highlighted the need to mitigate the burden of proof for the plaintiffs, but proceeded to review whether the plaintiffs proved the actual toxicity levels of the air pollutants, whether the defendant's vehicles were the main source of the emissions, the plaintiff's level of exposure to the pollutants, and causation between the emissions and the injury. By doing so, the district court required the plaintiffs to prove both indirect and direct facts of causation, increasing burden of proof for plaintiffs. The appellate court upheld the district court's decision, adding that the defendant's conduct did not constitute an illegal act because it did not violate the emissions standards set by environmental law. The Supreme Court upheld the appellate court's decision, reasoning that the epidemiological evidence cannot establish a direct causation for diseases that lack specificity. Conclusion: This case demonstrates that discussions in environmental health have significance in tort lawsuits. For each fact that the plaintiffs and defendants attempted to prove, environmental health research studies were offered as evidence. In addition, the courts decided the legality of the defendant's conduct based on emission standards set by environmental law.

파이버 레이저를 이용한 LNG선용 STS316L의 용접특성 (Weldability of STS316L for LNG Carrier by Fiber Laser)

  • 김종도;이재범;이창제;송무근;남기정
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권8호
    • /
    • pp.1061-1068
    • /
    • 2012
  • 오늘날 지구온난화, 환경오염 및 주요 에너지원인 화석연료의 고갈에 대한 우려가 높아지면서, 전세계적으로 신재생에너지 및 청정에너지에 대한 관심이 급격하게 증가하고 있다. 따라서 화석연료의 대체 및 SOX, NOX와 같은 오염물질을 적게 배출하는 청정에너지로써 LNG가 폭넓게 사용되고 있다. 그로인해 LNG의 소비는 급격하게 증가하고 있으며, 그것을 운반하기 위한 LNG선의 수요 또한 수십 년 동안 크게 증가하였다. 본 연구에서는 LNG선의 생산성을 향상시키기 위해 LNG선용 스테인리스강에 대한 용접에 고출력 파이버 레이저를 이용하였다. 사용된 재료는 탄소 함유량이 0.03% 이하의 STS316L이며 두께는 8mm이다. 최대출력 5kW의 파이버 레이저를 열원으로 사용하여 비초점거리, 겹치기 용접 그리고 맞대기 용접에 대한 실험을 진행하였다. 실험결과, 겹치기 용접의 경우 2.0m/min, 맞대기 용접의 경우 3.0m/min의 용접속도까지 접합이 가능하였다.

가솔린 연료형 SOFC시스템 성능 평가에 관한 연구 (Performance Analysis of Gasoline Fueled Marine Solid Oxide Fuel Cell System)

  • 오진숙;이경진;김선희;박상균;김만응;임태우;김종수;오세진;김명환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권6호
    • /
    • pp.740-749
    • /
    • 2011
  • 온실가스 및 대기오염물질 배출 규제는 고효율 및 친환경에 적합한 새로운 선박용 동력장치의 필요성을 제기하고 있다. 최근 이와 같은 문제들을 근본적으로 해결하기 위한 지속가능한 방법으로서 연료전지를 선박의 동력발생장치로 도입하고자 하는 검토가 진행되고 있다. 본 논문은 가솔린 연료를 기반으로 한 고체산화물형 연료전지시스템의 성능 특성을 분석한 것으로 스택의 작동온도, 전류밀도, S/C, 예열기 온도효율, 수소연료 이용률의 영향을 시뮬레이션으로 검토하고 있으며, 그 결과를 기체연료인 메탄의 경우와 비교하고 있다. 그 결과로 유기전압과 산소이용률이 시스템의 성능에 미치는 영향이 크며 가솔린 연료 시스템의 효율은 메탄의 경우보다 높지 않다는 것을 확인하였다.

LID 기법 적용에 의한 SCS-CN값 변화가 강우유출특성에 미치는 영향 분석 (The Analysis of Runoff Characteristics by Alterations of SCS-CN Value using LID Method)

  • 권준희;박인혁;하성룡
    • 환경영향평가
    • /
    • 제19권1호
    • /
    • pp.49-57
    • /
    • 2010
  • The objective of the research is to analyze changing trend of water discharge in precipitation, according to changing land use, through an environment-friendly urban development method called LID. The study chose S1 basin (Separated Sewer districts) in Cheongju region for survey. Among LID methods, relatively more applicable methods of green rooftop space and parking lot with permeable material were selected to construct plausible scenarios. Curve Number (CN) value was calculated due to land use patterns in each scenario, and SWMM model simulation were conducted during 2008 for comparative analysis. For Case 1, only parking lot with permeable material was applied to the scenario. Green rooftop space I and II were applied to Case 2 and 3 respectively. For Case 4 and 5, green rooftop space I and II were applied, in addition to parking lot with permeable material, Calculation of CN value showed that for S1 basin, the value was 88.1 (prior to scenario application), 86.5 (Case 1), 81.9 (Case 2), 68.5 (Case 3), 80.4 (Case 4) and 67.2 (Case 5). Changing pattern of rain water discharge was analyzed for each scenario. For Case 1, the change was not remarkable before and after application of scenario. In Case 2 and 4, the impact of rain water discharge as source of pollutant fell to 20~30%. The rate dropped to 30~50% in Case 3 and 5 respectively. The result demonstrates that the amount of rain water discharge, amount and frequency of sewer overflow, frequency of rain water discharge, and pollution load decreased in accordance with declining CN value in each scenario. In installing green rooftop space, the effect was twice greater when rain water discharge was directly infiltrated into soil.

소사육시설에서 가을철과 겨울철의 암모니아 플럭스 및 배출계수 산정에 관한 연구 (Estimation of Ammonia Flux and Emission Factor from the Cattle Housing of Fall and Winter)

  • 사재환;전의찬
    • 환경영향평가
    • /
    • 제19권1호
    • /
    • pp.1-13
    • /
    • 2010
  • Ammonia ($NH_3$) is an important pollutant that plays a key role in several air pollution problems. It can create odors and have negative impacts on animal and human health. The largest source contributing to Ammonia emission is the agricultural production, in particular animal operation, in Korea. The present study evaluated flux profiles of Ammonia emitted from the cattle housing using a dynamic flux chamber. We have developed the emission factor of Ammonia from the cow housing. Analysis of Ammonia flux variation was made with respect to manure surface temperature, pH, and ammonium concentration. Ammonia has been measured from calf and cattle housing between October and December in 2007. In the fall, average Ammonia flux from calf and cattle housing was estimated 1.342(${\pm}0.728$) and 1.323(${\pm}0.655$)mg/$m^2$/min, respectively. In the winter, average Ammonia flux was estimated 0.889(${\pm}0.362$)mg/$m^2$/min from the calf housing and 0.925(${\pm}0.511$)mg/$m^2$/min from the cattle housing. The correlation coefficient between Ammonia flux and ammonium concentration showed stronger relationship than the relationship between manure pH and temperature. In the fall, Ammonia emission factor from calf and cattle housing was estimated 4.46(${\pm}2.39$) and 6.03(${\pm}3.27$)kg-$NH_3$/animal/yr, respectively. In the winter, average Ammonia flux was estimated 2.88(${\pm}1.53$) from the calf housing and 4.24({$\pm}1.63$)kg-$NH_3$/animal/yr from the cattle housing.

낙동강 중·하류 지역의 수변 특성에 관한 연구 (Riparian Area Characteristics of the Middle and Lower Reaches of the Nakdong River, Korea)

  • 강대석;성기준;여운상;정용현;이석모
    • 환경영향평가
    • /
    • 제17권3호
    • /
    • pp.189-200
    • /
    • 2008
  • As a transition zone between terrestrial and aquatic ecosystems, riparian areas of rivers and streams play significant roles in production and decomposition for river and stream systems. Understanding of the physical and ecological characteristics of riparian areas are, therefore, important for the management of river and stream systems. It is especially important to understand the characteristics of riparian areas for the Nakdong River in Korea which has a large watershed area and diverse land uses. This study aimed at collecting field data, according to stream types, which are essential for the management of riparian areas of the middle and lower reaches of the Nakdong River, Korea. Most riparian areas surveyed in this study had roads within 100 meters from river edges. Distances from water edge to banks were less than 1m for most riparian areas neighboring agricultural lands, indicating that those areas might be very vulnerable to pollutant inputs from non-point sources. Water quality data indicated that soil erosion in the riparian areas could be a major source of phosphorus input to the Nakdong River and land use patters might have a significant influence on nitrogen concentration in the river. Heavy metal concentrations in soils of the riparian areas of the river were below soil quality standards, except arsenic and chromium. Vegetation surveys showed that therophytes were the most frequently occurred riparian plants in the Nakdong River. Number of aquatic plant species increased downstream, with the most diverse aquatic plants observed in wetlands and irrigation canals of the West Nakdong River. Occurrence rate of naturalized plants and urbanization index were high in the survey sites adjacent to urban and agricultural areas.

공단지역의 대기배출시설을 대상으로 한 악취성분의 처리효율에 관한 연구 - 반월공단 지역을 중심으로 (A Study of Control Efficiency for Odorous Pollutants in Various Emission Control Units in the Ban-Wall Industrial Complex)

  • 최여진;전의찬;김기현
    • 한국대기환경학회지
    • /
    • 제23권1호
    • /
    • pp.110-124
    • /
    • 2007
  • In this study, the control efficiency of odorous compounds was measured from diverse control process units of 14 individual companies located within the Ban-Wall industrial complex of Ansan city, Korea (January to July 2005), To quantify the control efficiency levels of major odorous compounds, we collected odor samples from both the front and rear side of 17 control process units ($N=17{\times}2=34$). If the control efficiency is compared for each of 32 compounds between different process units, wet scrubber (WS) was found to be the most effective unit in terms of the sum of pollutants showing the positive control signals. Although the WS system shows generally a good control pattern for VOC, it is not the case for most index odorous pollutants; only 3 out of 12 index compounds were found to show positive control efficiencies. The results of the study also indicated that the control efficiency differ greatly between different industrial sectors and/or control process types. In the case of leather industry, carbonyl compounds were found to exhibit the highest control efficiency with its values varying from 19 to 90%. On the other hand, in the case of metal production sector, VOC recorded the maximum control efficiency with values varying from 18 to 79%. According to this study, most air pollution control facilities operated in most companies show fairly poor control efficiencies for most malodor compounds. Hence, to obtain best control efficiency of odorous pollutant emission, acquisition of better information on source characteristics and establishment of effective control technologies are highly demanding.

WEPP 모형을 이용한 골프장 잔디 관리에 따른 유출특성 모의 (Evaluation of Runoff Prediction from Managed Golf Course using WEPP Watershed Model)

  • 최재완;신민환;류지철;금동혁;강현우;천세억;신동석;임경재
    • 한국물환경학회지
    • /
    • 제28권1호
    • /
    • pp.1-9
    • /
    • 2012
  • It has been known that Golf course could impose negative impacts on water-ecosystem if pollutant-laden runoff is not treated well. It is important to control non-point source and re-use treated wastewater from the golf course to secure water quality of receiving waterbodies. At golf courses, the rainfall-runoff is affected by various practices to manage grasses. In many hydrological modelings, especially in simple rainfall-runoff modeling, effects on runoff of plant growth and cutting are not considered. In the study, the water erosion prediction project (WEPP), capable of simulating plant growth and various management, was evaluated for its runoff prediction from golf course under grass cutting and irrigation. The %Difference, $R^2$ and the NSE for runoff comparisons were 1.15%, 0.93 and 0.92 for calibration, and 18.12%, 0.82 and 0.88 for validation period, respectively. In grass cutting scenario, grass height was managed to be 18~25 mm. The estimated runoff was decreased by 27%. The difference in estimated total runoff was 11.8% depending on irrigation. As shown in this study, if grass management and irrigation are well-controlled, water quality of downstream areas could be obtained.

도시유역 저류형 시스템 설계를 위한 CSOs 산정 (Storm-Water CSOs for Reservoir System Designs in Urban Area)

  • 조덕준;김명수;이정호;박무종;김중훈
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2005년도 학술발표회 논문집
    • /
    • pp.1199-1203
    • /
    • 2005
  • Combined sewer overflows(CSOs) are themselves a significant source of water pollution. Therefore, the control of urban drainage for CSOs reduction and receiving water quality protection is needed. Examples in combined sewer systems include downstream storage facilities that detain runoff during periods of high flow and allow the detained water to be conveyed by an interceptor sewer to a centralized treatment plant during periods of low flow. The design of such facilities as stormwater detention storage is highly dependant on the temporal variability of storage capacity available(which is influenced by the duration of interevent dry periods) as well as the infiltration capacity of soil and recovery of depression storage. As a result, a contiunous approach is required to adequately size such facilities. This study for the continuous long-term analysis of urban dranage system used analytical Probabilistic model based on derived probability distribution theory. As an alternative to the modeling of urban drainage system for planning or screening level analysis of runoff control alternatives, this model have evolved that offer much ease and flexibility in terms of computation while considering long-term meteorology. This study presented rainfall and runoff characteristics or the subject area using analytical Probabilistic model. Runoff characteristics manifasted the unique characteristics of the subject area with the infiltration capacity of soil and recovery of depression storage and was examined appropriately by sensitivity analysis. This study presented the average annual COSs and number of COSs when the interceptor capacity is in the range 3xDWF(dry weather flow). Also, calculated the average annual mass of pollutant lost in CSOs using Event Mean Concentration. Finally, this study presented a dicision of storage volume for CSOs reduction and water quality protection.

  • PDF