• Title/Summary/Keyword: pollutant removal efficiency

Search Result 208, Processing Time 0.025 seconds

The Experimental Study on the Removal of Diesel Engine Pollutant Emissions Using DC Non-Thermal-Plasma(NTP) (DC 저온플라즈마를 이용한 디젤엔진 유해 배기가스 저감에 관한 실험적 연구)

  • Chae, Jae-Ou;Hwang, Jae-Won;Jung, Jee-Yong;Han, Jung-Hee;Hwang, Hwa-Ja;Kim, Seok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.2
    • /
    • pp.35-42
    • /
    • 2001
  • The diesel engine exhaust gas is know as one of the causes to produce photochemical smog, which causes damage on environmental. However, due to the high thermal efficiency and low carbon dioxide emission, the usage of a diesel engine is prevailed. In this study, the DC non-thermal plasma technology used to the particulate matter (PM) aftertreatment. The exhaust gas characteristics and energy density were investigated on the dynamometer test bed and chassis dynamometer with CVS-75 mode in a passenger diesel car. It was reported that the smoke removal efficiency has around the 70% in the dynamometer test with 80W energy consumption and the PM removal efficiency has the 68% in the real car test. The NOx also reduced the 20% according to electrode type respectively. Considering these results, plasma technology is one of the ways to simultaneously removing method the particulate matter (PM) and NOx.

  • PDF

Analysis of water purification in the FWS wetland for Agreculture Area (농업지역 내 FWS 인공습지의 수질정화효율 분석)

  • Kang, Chang-Guk;Maniquiz, Marla C.;Son, Young-Gyu;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.12 no.3
    • /
    • pp.39-47
    • /
    • 2010
  • Annually, the scale of agricultural areas in Korea were being reduced as the lands were converted to other land uses. While the rate of productivity were either being maintained or increased, the pollution load from these areas were still greater in magnitude. Although the levels of pollutant concentration released in the agricultural watersheds were minimal, the combined quantities mostly from diffuse sources were high. As a consequence, the Ministry of Environment (MOE) in Korea adopted the use of free water surface (FWS) flow constructed wetlands to reduce the pollutant loadings emitted from agricultural watersheds for the improvement of water quality and protection of aquatic ecosystems. In this study, a constructed wetland treating stream water in an agricultural watershed was monitored since April 2009 subsequent to its completion in December 2008. Satisfactory performance was achieved for TSS, BOD and TP with 26%, 28% and 39% pollutant removal rates, respectively. In addition, the effluent water quality was improved and achieved compliance the national water quality criteria. Results of this study can be useful to establish design parameters and employ proper removal techniques of similar natural treatment systems for future implementation in the country.

Effect of Pollutant Loading and Flow Distance to Wastewater Treatment Efficiency in the Constructed Wetland System (오염부하량 및 유하거리가 인공습지에 의한 폐수처리 효율에 미치는 영향)

  • 김형중;김선주;윤춘경
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.5
    • /
    • pp.97-108
    • /
    • 1997
  • Natural wastewater treatment systems using the constructed wetland system were evaluated for the wastewater from the industrial complex in rural areas. For the treatment of wastewater from the industrial complex in rural area, a pilot plant of the constructed wetland system was installed at Baeksuk agri-industrial complex in ChunahnCity, Chunchungnam-Do. The experiment with this pilot plants was performed for 1996 and 1997. Results of the study were summarized as follows. For the BOD and COD, when the pollutant loading of them was about 1 3.8g/$m^2$. day (the concentration was l24.0mg/${\ell}$) arid 24.4g/$m^2$.day(the concentration was 220.Omg/${\ell}$), the removal rate of them was high, 90.2% and 93.4%, respectively. For the SS, the effluent concentration was consistently lower than the water quality standard even though the influent concentration varied significantly, which showed that SS was removed by the system effectively which consist of soil and plants. For the T-N and T-P, when the influent pollutant loading of them were moderately high, 2.8g/$m^2$.day to 7.4g/$m^2$. day(concentration 25.0mg/${\ell}$ to 49.7mg/${\ell}$) for T-N and 1.0g/$m^2$.day to 2.6g /$m^2$.day(concentration 8.6mg/${\ell}$ to 14.7mg/${\ell}$) for T-P, the removal rate of them were 86.5% and 94.0%, respectively. The removal rate by the flow distance increased rapidly in the first 4m from the inlet zone, and gradually there after. The width of system was 2m. Overall, the result showed that constructed wetland system is a feasible alternative for the treatment of wastewater from industrial complex in rural areas. Compared to existing systems, this system is quite competitive because it requires low capital cost, almost no energy and maintenance, and therefore, very cost effective.

  • PDF

Effect of Ozone Treatment for Nakdong River Raw Water - II. Removal of VOCs and Algae in Raw Water by Conducting Batch Test of Ozonation Experiments - (낙동강 상수원수의 오존처리 효과 - II. 회분식 오존처리에 의한 휘발성유기화합물 및 조류제거 효과 -)

  • 임영성;이홍재;이도진;허종수;손보균;조주식
    • Journal of Environmental Science International
    • /
    • v.11 no.12
    • /
    • pp.1267-1274
    • /
    • 2002
  • This study was carried out to evaluate the pollutant removal efficiencies of the advanced drinking water treatment using ozonation process. For raw water, Nakdong River was used. By conducting batch test of ozonation, the following results were obtained. When ozone dosage of $5 mg/{\ell}$ was used, ozone transfer and utilization efficiencies of the ozonation were 94 to 92%, respectively. Removal efficiencies of single VOC compound or mixed VOC compounds in the raw water were 80% to 90% by the ozonation with $2 mg/{\ell}$ dosage and 10 minutes contact time. Removal efficiencies of ABS by the ozonation with $1 mg/{\ell}$, $3 mg/{\ell}$ dosage and 20 minutes contact time were 83% to 96%, respectively. Almost 67% of chlorophyll-a at the concentration of $38.4\mu\textrm{g}/{\ell}$ was removed by ozonation at ozone dosage of $1 mg/{\ell}$ for 20 min. Considering the efficiency of ozone utilization and water treatment, the most effective ozonation could be obtained with high ozone dosage and short contact time.

Nitrogen Removal from Wastewater by a Multi-stage Bio-reactor (다단 생물반응기에 의한 질소제거)

  • 최규철;정일현
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.1
    • /
    • pp.91-103
    • /
    • 1998
  • Design data for COD and nitrogen removal from wastewater were collected from Pilot's Multi-stage Bio-reactor. Hyraulic conditions and pollutant loadings were varied in order to optimize the biological and operational parameters. Pilot's experimental results summarize as followings. 1. T-N removal efficiency in the organic volumetric loading 0.2 kgCOD/m$^{3}$·d was obtained as maxium of 85% at internal recycle ratio 2.5 and in more ratio than this it was decreased. Organic removal efficiency was about 91% under the overall experimental conditions and not influenced by recycle ratio.. 2. Nitrification reaction was shown as maxium in the SCOD$_{cr}$/NH$^{+}$-N ratio of 6.5 and in more ratio than this it was decreased. Denitrification rate was the maxium as 85% in more than 7.5 of SCOD$_{cr}$/NO$_{x}$-N ratio and in the ratio over this ratio it becomes constant. 3. By utilizing an applied new model of Stover-Kincannon from Monod's kinetic model, concentration of T-N in the effluent according to flow quanity in the influent was estimated as 8.74 and -67.5 respectively. The formula for estimating T-N concentration of effluent was obtained like this: N$_e$=N$_0$(1- $\frac{8.74}{(QN$_0$/A)-67.05}$)

  • PDF

NDMA(N-nitrosodimethylamine) Removal Uising Membrane at Aerobic and Anaerobic Conditions (호기/혐기 조건에서 Membrane을 이용한 NDMA(N-nitrosodimethylamine)제거)

  • Kim, Hui-Joo;Chung, Jin-Wook;Choi, Chang-Kyoo;Kim, Moon-Il
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.417-420
    • /
    • 2008
  • Recently, the interest in NDMA(N-nitrosodimethylamine) has increased due to its recognition as a pollutant by Ontario Ministry of Environment and Energy and California Department of Health Sciences. It is, in fact, one of the DBPs(Disinfection By-products) which appears due to chlorination and is reported to be fatal if exposed continuously to human body. Due to uncertainty in mechanism to remove it, its treatment is not yet carried out. In this experiment, treatment of biological NDMA is carried out by letting it adsorbed on Granular Sludge and then filtering the medium through MF(Microfiltration) and UF(Ultrafiltration) membranes. Granular Sludge is adapted to aerobic and anaerobic conditions for 7 days and the experimental conditions are MLSS of 8000mg/L, COD of 250mg/L, TN of 12.5mg/L, and TP of 2.5mg/L. Several batch tests were carried out and samples were collected with the interval of 1 hour. Samples were measured by LSC(Liquid scintillation counter) after filtering by MF and UF. In batch test with granular sludge the permeate concentrations(removal efficiencies) of NDMA by MF and UF were 71.7ng/L(32.0%) and 62.0ng/L(43.7%) at aerobic state, and 52.0ng/L(49.2%) and 47.6ng/L(58.9%) at anaerobic state, respectively. Hence, UF membrane showed about 10% more removal efficiency than MF and removal efficiency at anaerobic condition was 15% more than that at aerobic condition.

  • PDF

A Study on the Treatment of Paper Mill Wastewater with the Addition of High Thermal Microbial Inoculants (고온성 종균제를 이용한 제지폐수 처리)

  • 이성호;임택준;조준형
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.34 no.2
    • /
    • pp.54-60
    • /
    • 2002
  • The Wastewater of toilet paper mill recycling recovered milk carton was used as a raw material for this study. According to the actual mill conditions, hydraulic retention time was adjusted to 12 hours and F/M (Food/Micro-organism) ratio was adjusted to 0.23. Temperature of aeration basin was varied from 2$0^{\circ}C$ to 5$0^{\circ}C$. The change of Micro-organisms and removal efficiency of pollutant were investigated at the varied temperature of basin. Aeration basin using high thermal microbial inoculants showed more removal efficiency of SS, COD than aeration basin using conventional microbial inoculants at high temperature. Floc consolidation of aeration basin using high thermal microbial inoculants added sludge was better than that of sludge from aeration basin using conventional microbial inoculants.

Evaluation of Green House Gases (GHGs) Reduction Plan in Combination with Air Pollutants Reduction in Busan Metropolitan City in Korea

  • Cheong, Jang-Pyo;Kim, Chul-Han;Chang, Jae-Soo
    • Asian Journal of Atmospheric Environment
    • /
    • v.5 no.4
    • /
    • pp.228-236
    • /
    • 2011
  • Since most Green House Gases (GHGs) and air pollutants are generated from the same sources, it will be cost-effective to develop a GHGs reduction plan in combination with simultaneous removal of air pollutants. However, effects on air pollutants reduction according to implementing any GHG abatement plans have been rarely studied. Reflecting simultaneous removal of air pollutants along with the GHGs emission reduction, this study investigated relative cost effectiveness among GHGs reduction action plans in Busan Metropolitan City. We employed the Data Envelopment Analysis (DEA), a methodology that evaluates relative efficiency of decision-making units (DMUs) producing multiple outputs with multiple inputs, for the investigation. Assigning each GHGs reduction action plan to a DMU, implementation cost of each GHGs reduction action plan to an input, and reduction potential of GHGs and air pollutants by each GHGs reduction action plan to an output, we calculated efficiency scores for each GHGs reduction action plan. When the simultaneous removal of air pollutants with the GHGs reduction were considered, green house supply-insulation improvement and intelligent transportation system (ITS) projects had high efficiency scores for cost-positive action plans. For cost-negative action plans, green start network formation and running, and daily car use control program had high efficiency scores. When only the GHGs reduction was considered, project priority orders based on efficiency scores were somewhat different from those when both the removal of air pollutants and GHGs reduction were considered at the same time. The expected action plan priority difference is attributed to great difference of air pollutants reduction potential according to types of energy sources to be reduced.

Hydrologic and Environmental Assessment of an Infiltration Planter for Roof Runoff Use (지붕 빗물이용을 위하여 개발된 침투화분의 환경·수문학적 평가)

  • Moon, So-Yeon;Choi, Ji-Yeon;Hong, Jung-Sun;Yu, Gi-Gyung;Jeon, Je-Chan;Flores, Precious Eureka D.;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.17 no.4
    • /
    • pp.325-331
    • /
    • 2015
  • Due to urbanization and increase in impervious area, changes in natural water circulation system have become a cause of groundwater recharge reduction, streamflow depletion and other hydrological problems. Therefore, this study developed the infiltration planter techniques applied in an LID facility treating roof stormwater runoff such as, performance of small decentralized retention and infiltration through the reproduction of natural water circulation system and use of landscape for cleaning water. Assessment of an infiltration planter was performed through rainfall monitoring to analyze the water balance and pollutant removal efficiency. Hydrologic assessment of an infiltration planter, showed a delay in time of effluent for roof runoff for about 3 hours and on average, 79% of facilities had a runoff reduction through retention and infiltration. Based on the analysis, pollutant removal efficiency generated in the catchment area showed an average of 97% for the particulate matter, 94% for the organic matter and 86-96% and 92-93% for the nutrients and heavy metals were treated, respectively. Comparative results with other LID facilities were made. For this study, facilities compared the SA/CA to high pollutant removal efficiency for the determination to of the effectiveness of the facility when applied in an urban area.

Ion Exchange Processes: A Potential Approach for the Removal of Natural Organic Matter from Water

  • Khan, Mohd Danish;Ahn, Ji Whan
    • Journal of Energy Engineering
    • /
    • v.27 no.2
    • /
    • pp.70-80
    • /
    • 2018
  • Natural organic matter (NOM) is among the most common pollutant in underground and surface waters. It comprises of humic substances which contains anionic macromolecules such as aliphatic and aromatic compounds of a wide range of molecular weights along with carboxylic, phenolic functional groups. Although the concentration of NOM in potable water usually lies in the range of 1-10 ppm. Conventional treatment technologies are facing challenge in removing NOM effectively. The main issues are concentrated to low efficiency, membrane fouling, and harmful by-product formation. Ion-exchangers can be considered as an efficient and economic pretreatment technology for the removal of NOM. It not only consumes less time for pretreatment but also resist formation of trihalomethanes (THMs), an unwanted harmful by-product. This article provides a comprehensive review of ion exchange processes for the removal of NOM.