• Title/Summary/Keyword: pollutant concentration

Search Result 859, Processing Time 0.02 seconds

Study on the Discharge Characteristics of Non-point Pollutant Source in the Urban Area of the Youngsan-River Basin (영산강 유역 도시지역의 비점오염원 배출특성에 관한 연구)

  • Jin, Young-Hoon;Park, Sung-Chun
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.4
    • /
    • pp.605-613
    • /
    • 2006
  • Discharge characteristics of non-point source pollutant and load amount of the discharge in the urban area were investigated in the Pungyeongjeong-stream basin and the Yongbong-stream basin in this present study. The land use of the studied basins were divided into paddy field, industrial complex area, combined sewage system, separate sewer system and point sources discharge. The descriptive statistics on the event mean concentrations (EMCs) of non-point pollutants by the the land use showed in the range of 4.43-32.28 mg/L for BOD and 8.27~56.17 mg/L for COD. The highest concentration was shown from the combined sewage system. The EMC of SS at the paddy field in the Pungyeongjeong-stream basin showed the highest range with the values ~ from 35.76 to 358.86 mg/L, which might have been influenced by a levee construction in the adjacent of the area. The relatively high concentration values of 4.43~32.28 mg/L and 1.617.13 mg/L emerged from TN and TP,respectively, at the discharge points of the both stream basins.

Modelling the Dispersion Behavior of Conservative Pollutants within Daechung Dam using EFDC-Hydro (EFDC를 이용한 대청댐내 보존성 오염물질 확산 모델링에 관한 연구)

  • Park, No-Suk;Kim, Seong-Su;Chong, Sun-A;Kim, Jong-Oh;Kim, Do-Hwan;Kang, Moon-Sun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.5
    • /
    • pp.705-712
    • /
    • 2012
  • Selecting Daechung Dam as a sample study site, this study simulates virtual water quality incident which can be occurred using EFDC maintained by USEPA. In order to predict the behavior and diffusion of leaked conservative pollutant within dam under the worst condition, the hydrological data and information from 2008 were used. EFDC was successfully calibrated for observed water level obtained from the above sources. From the results of simulations, even though the concentrations (500 ppm, 1,000 ppm and 10,000 ppm) of leaked pollutant were different with each other at the same sources, the travel time of each peak concentration appeared similar. Also, changing the leak source point from dam gate(0 km) to 7 km, it was found that as leak source point was nearer to the dam gate, the travel time of each peak concentration showed up sooner. It was simulated to take 1 day to 15 days for initial appearance of the leaked pollutant according to the leaked points, and 3 days to 25 days for the reach of the peak concentration, respectively.

The characteristics of discharged non-point pollutants on Hwa-sung lake inflow streams on precipitation (화성호 유입하천의 강우시 비점오염물질 유출특성)

  • Lee, Sang Eun;Choi, I Song;Lee, In Ho;Hong, Dae Byuk;Oh, Jong Min
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.5
    • /
    • pp.651-661
    • /
    • 2011
  • The purpose of this study is to estimate the characteristics and pollutant loadings of non-point pollutants that flowed in the streams on precipitation for pollutant loading reduction of Hwa-sung lake inflow streams. Although it has been made an effort to improve the water quality of Hwa-sung basin through the strategies for the preservation of water quality, it is shown that the water quality is not greatly improved. Because it has been industrialized and urbanized near Hwa-sung basin so that it is difficult to reduce the water pollution due to the increase in pollutant loadings of point and non-point sources. In this study, it is investigated the outflow characteristics of non-point pollutants that discharged with storm runoff and estimated the effect of runoff on Hwa-sung basin. The final goal of this study is to utilize the basic information for proper management and strategies of non-point sources on Hwa-sung basin. At the result of inflow streams, Ja-an stream that has the greatest pollutant loadings on precipitation is strongly influenced on the water quantity of Hwa-sung basin. On the other hand, it is shown that Nam-yang stream is strongly influenced on the SS concentration of Hwasung basin among them. Also, all streams; Nam-yang, Ja-ahn, Ah-eun stream; has the degree of slope more than or near 1 in the correlation results so that they have strong pollutant loading impact and the concentration of SS is the highest among other pollutants. So, specific studies on initial rain phenomena are more necessary to manage the pollutants economically. Also, the proper control of SS concentration is required to manage the effluent pollutants effectively on precipitation. So, it is necessary to consider the strategies for non-point pollutants as well as point pollutants when the new management is imposed to reduce the pollutant load for improvement of Hwa-sung basin.

Effect of Pollutant Loading and Flow Distance to Wastewater Treatment Efficiency in the Constructed Wetland System (오염부하량 및 유하거리가 인공습지에 의한 폐수처리 효율에 미치는 영향)

  • 김형중;김선주;윤춘경
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.5
    • /
    • pp.97-108
    • /
    • 1997
  • Natural wastewater treatment systems using the constructed wetland system were evaluated for the wastewater from the industrial complex in rural areas. For the treatment of wastewater from the industrial complex in rural area, a pilot plant of the constructed wetland system was installed at Baeksuk agri-industrial complex in ChunahnCity, Chunchungnam-Do. The experiment with this pilot plants was performed for 1996 and 1997. Results of the study were summarized as follows. For the BOD and COD, when the pollutant loading of them was about 1 3.8g/$m^2$. day (the concentration was l24.0mg/${\ell}$) arid 24.4g/$m^2$.day(the concentration was 220.Omg/${\ell}$), the removal rate of them was high, 90.2% and 93.4%, respectively. For the SS, the effluent concentration was consistently lower than the water quality standard even though the influent concentration varied significantly, which showed that SS was removed by the system effectively which consist of soil and plants. For the T-N and T-P, when the influent pollutant loading of them were moderately high, 2.8g/$m^2$.day to 7.4g/$m^2$. day(concentration 25.0mg/${\ell}$ to 49.7mg/${\ell}$) for T-N and 1.0g/$m^2$.day to 2.6g /$m^2$.day(concentration 8.6mg/${\ell}$ to 14.7mg/${\ell}$) for T-P, the removal rate of them were 86.5% and 94.0%, respectively. The removal rate by the flow distance increased rapidly in the first 4m from the inlet zone, and gradually there after. The width of system was 2m. Overall, the result showed that constructed wetland system is a feasible alternative for the treatment of wastewater from industrial complex in rural areas. Compared to existing systems, this system is quite competitive because it requires low capital cost, almost no energy and maintenance, and therefore, very cost effective.

  • PDF

Estimation of Pollutant Loadings from Watershed into Lakes of Ganwol and Boonam (간월호 및 부남호의 유입 오염부하량 산정)

  • Lim, Kyeong-Ho;Lee, Young-Sin;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.8 no.4
    • /
    • pp.33-40
    • /
    • 2006
  • The water of rivers and lakes in Korea is the main sources for drinking, industrial and agricultural purposes. However, various pollutants washed-off from watershed area make worse and worse the water quality. Particularly, the changes of land uses in watershed area is the main pollutant sources in many cases in Korea, it is usually called to nonpoint pollution sources. In this reason, the Ministry of Environment are programing the total maximum daily load for four major large rivers in order to improve the water quality by controlling the watershed area. Therefore, this research was performed to estimate the total pollutant input from watershed areas to lakes of Ganwol and Boonam located in Chungnamdo. The AGNPS water quality model and monitoring were used to estimate the pollutant loading rates with unit pollutant concentration of each land use. The main landuse of the research area are forest, wet and dry paddy field and small urban area. The research shows that the pollutant sources in Ganwol and Boonam lakes are from the various landuses. In this manuscripts, the results will provide important informations for mitigating the pollutants to the lakes.

  • PDF

Odor Modeling of trimethyl amine in Gumi National Industrial Complex (구미국가산업단지의 트리메틸아민 악취모델링)

  • Lee, Eun Ju;Khan, Mousumee;Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.54 no.2
    • /
    • pp.187-199
    • /
    • 2016
  • In this study CALPUFF modeling was performed to predict a contribution of a separate single point pollutant source as well as of total point pollutant sources of major synthetic fiber manufacturers in Gumi national industrial complex to atmospheric trimethylamine concentration of the same area. In addition, a contribution of the separate single point pollution source to the atmospheric trimethylamine concentration of the same area was estimated relatively to the total point pollutant sources. As a result of the CALPUFF modeling, the maximum atmospheric concentration of trimethylamine in Gumi national industrial complex was appeared upon improving T company emission facility frequently in complex 3 in winter (January) and spring (April) while frequently in complex 1 in summer (July) and autumn (October). Besides, the predicted range of the maximum atmospheric concentration of trimethylamine in complex 1 was improved upon improving its emission facility. However, even though in complex 3 the upper bound of the predicted maximum atmospheric concentrations of trimethylamine was increased upon improving T company emission facility, the predicted value of their second upper bound below the upper bound was very similar to the upper bound of measured atmospheric trimethylamine concentrations in Gumi prior to improving its emission facility. Thus, the effect of improving T company emission facility was estimated huge in complex 1 while it was trivial in complex 3. These maximum concentrations of trimethylamine predicted to estimate the expected contribution of total point pollutant sources by CALPUFF modeling showed the similar values to those measured in the region of Gumi. Therefore, the expected contribution of total point pollutant sources to atmospheric trimethylamine concentration in the area of Gumi was validated.

Characteristics of Collected Sediments from Road Sweeping and Reduction in the Nonpoint Source Pollutants Loading (도로청소 수거퇴적물의 특성과 비점오염물질 저감효과)

  • Jeong, Kwon;Kang, Hee-Man;Ko, Seok-Oh
    • International Journal of Highway Engineering
    • /
    • v.13 no.2
    • /
    • pp.187-193
    • /
    • 2011
  • The stormwater runoff from road or expressway is known as one of important nonpoint pollution sources. To reduce the pollutants discharge from road or expressway, many best management practices(BMPs) have been applied and planned. Among the BMPs, road sweeping can be effective way to prevent pollutant washoff to environment. This study is performed to evaluate the characteristics of particles collected from the road by sweeping car. Size distribution and pollutant concentration of particles were analyzed. Based on the pollutant concentration and the specification of road such as length, width, and unit for pollutant generation, total amount of pollutant to be removed by road sweeping was estimated. Most of sediments collected by road sweeping was classified into sandy soil and fraction of fine grained soil was low. Although the concentrations of pollutants such as heavy metals in road sediments did not exceed the soil contamination criteria, washout of pollutants during sweeping work by spraying water might cause leaching of pollutants contained in sediments and thus resulted in low pollutant concentrations. Reduced amounts of pollutant by road sweeping showed 31.4% TSS reduction for ${\bigcirc}{\bigcirc}$ region and 7.7% TSS for ${\triangle}{\triangle}$ region. Other pollutants showed low reduction rate, because of their leaching by water spraying. Results from this study indicate that detailed and well-planned investigation for the road sweeping is necessary for the accurate estimation of pollutant reduction from road or expressway.

Wind Tunnel Experiments for Studying Atmospheric Dispersion in the Complex Terrain I.Dispersion in a mountainous Area (복잡한 지형내 오염물질의 대기확산 풍동실험: I. 산지지형에서의 확산)

  • 경남호;김영성;손재익
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.8 no.3
    • /
    • pp.169-178
    • /
    • 1992
  • Dispersion of pollutant in a mountainous area is simulated in a wind tunnel. In the northwest side of the terrain model, the sea level is assumed. Wind from the sea initially confronts hills along the shoreline, a line of large buildings next, and finally a valley between high mountains in the south and in the east. In the northwest wind conditions, severe flow separation occurs in the lee side of hills, even beyond the building area. Pollutant from the buildings is trapped in this region and its concentration is the highest. In the west wind conditions, pollutant from the buildings flows along the hills aslant the main wind direction in this case. Since large valley is located in the downstream, pollutant tends to disperse along the valley.

  • PDF

Water quality management of Jeiu Harbor using material cycle model(III) - Quantitative Management of Pollutant Loadings - (물질순환모델을 이용한 제주항의 수질관리(III) - 오염부하의 정량적 관리 -)

  • 조은일;강기봉
    • Journal of Environmental Science International
    • /
    • v.12 no.3
    • /
    • pp.307-317
    • /
    • 2003
  • In this study, the material cycle model was applied to suggest alternative management of water quality for Jeju Harbor. The distribution of COD, DIN (dissolved inorganic nitrogen) and DIP (dissolved inorganic phosphorus) concentrations was reasonably reproduced by simulations on the model area of the Jeju Harbor using a material cycle model. The simulations of COD, DIN and DIP concentrations were performed under the conditions of 20∼100% pollution loadings reductions from pollution sources. In case of the 100% reduction of the input loads from Sanzi river, concentrations of COD, DM and DIP were reduced to 39%, 78% and 52%, respectively at Jeju harbor. In contrast, in case of the pollutant loadings reductions from sediment, the effect of DIN and DIP reduction relatively seemed to increase around the center of study area. The 95% reduction of the pollutant loadings from river and sediment is required to meet the COD and nutrients concentration of second grade of ocean water quality criteria.

The Regional Characteristics of Nonpoint Source Pollutant Loads in Mid-stream of Nakdong River (낙동강 중류유역의 지역별 비점오염 특성)

  • Son, Seong-Ho;Choe, Gyeong-Suk
    • KCID journal
    • /
    • v.14 no.2
    • /
    • pp.181-193
    • /
    • 2007
  • The characteristics of non-point source pollutant loads in middle-stream of Nakdong River Were studied through analysis of pollutant loads of 8 sub-watersheds divided based on administrative district. The pollutant concentration of each sub-watershed was collected from Nakdong-River Water Research Institute and Daegu Regional Environmental Office, respectively. Pollution items analysed in this study were BOD, SS, T-N and T-P. High degree of non-point pollution was observed from Gumi, Goryeong, Gyeongsan, Daegu and Sungju, and pollution was usually increased during rainy season. This result indicates that a given pollution condition within the watershed can be more sensitive than location factor to the level of water quality. The main sources of non-point pollution were population and livestock, as well as landuse factor, and were found to significantly contribute to the water pollution. Alternative solutions for controlling pollution sources, therefore, should be provided to meet target levels of water quality in this region.

  • PDF