• 제목/요약/키워드: polarization estimation

Search Result 89, Processing Time 0.033 seconds

Effect of Anode Gas Channel Height on Gas Diffusion and Cell Performance in a Molten Carbonate Fuel Cell (용융탄산염 연료전지 연료극 기체 유로 높이에 따른 가스 확산 및 단전지 성능 변화 연구)

  • Lee, Jung-Hyun;Kim, Do-Hyung;Kim, Beum-Ju;Kang, Seung-Won;Lim, Hee-Chun
    • Journal of Hydrogen and New Energy
    • /
    • v.20 no.6
    • /
    • pp.479-484
    • /
    • 2009
  • The effect of anode gas channel height on gas diffusion and cell performance in a 100 $cm^2$ class molten carbonate single cell is investigated. Single cell separators with three different channel height are used. The effect of the gas channel height on the distribution of the reactive gas concentration is evaluated by the two-dimensional concentration diffusion equation. The overpotential caused by concentration drop with different channel height is estimated by the voltage decay related to diffusion of reactants, well known as concentration polarization, using limiting current density. The estimation could have the possibility to identify the reactant mass transfer polarization in the complicate factors of the overall electrodes.

The Recognition and Segmentation of the Road Surface State using Wavelet Image Processing (웨이블릿 영상처리에 의한 도로표면상태 인식 및 분류)

  • Han, Tae-Hwan;Ryu, Seung-Ki;Song, Wonseok;Lee, Seung-Rae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.26-34
    • /
    • 2008
  • This study focus on segmentation process that classifies road surfaces into 5 different categories, dry, wet water, icy, and snowy surfaces by analyzing asphalt-paved road images taken in daylight. By using the polarization coefficients, the proportions of horizontally polarized components to vertically polarized components, regions with over 1.3 polarization coefficients are classified as wet surfaces. Except for wet surfaces, the decision process a lies time-frequency analysis to other parts by using the third order wavelet packet transform. In addition, by using the average frequency characteristics of dry and icy surfaces from image templates, decide which is closer to a test image, and finally identify dry and icy surfaces. It is confirmed that the reposed estimation and segmentation of recognition on various images. This can be interpreted as an indication that image-only mad surface condition supervision is probable.

Degradation Damage Evaluation of High Temperature Structural Components by Electrochemical Anodic Polarization Test (전기화학적 양극분극시험에 의한 고온 설비부재의 열화손상 평가)

  • Yu, Ho-Seon;Song, Mun-Sang;Song, Gi-Uk;Ryu, Dae-Yeong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.6 s.177
    • /
    • pp.1398-1407
    • /
    • 2000
  • The structural steels of power plant show the decrease of mechanical properties due to degradation such as temper embrittlement, creep damage and softening during long-term operation at high temper ature. The typical causes of material degradation damage are the creation and coarsening of carbides(M23C6, M6C) and the segregation of impurities(P, Sb and Sn) to grain boundary. It is also well known that material degradation induces the cleavage fracture and increases the ductile-brittle transition temperature of steels. So, it is very important to evaluate degradation damage to secure the reliable and efficient service condition and to prevent brittle failure in service. However, it would not be appropriate to sample a large test piece from in-service components. Therefore, it is necessary to develop a couple of new approaches to the non-destructive estimation technique which may be applicable to assessing the material degradation of the components with not to influence their essential strength. The purpose of this study is to propose and establish a new electrochemical technique for non-destructive evaluation of material degradation damage for Cr-Mo steels which is widely used in the high temperature structural components. And the electrochemical anodic polarization test results are compared with those of semi-nondestructive SP test.

A Study on Scattering Center Extraction Using Full Polarimetric Data (다중편파 데이터를 이용한 표적 산란점 추출에 대한 연구)

  • Jeong, Seong-Jae;Lee, Seung-Jae;Kim, Kyung-Tae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.5
    • /
    • pp.463-470
    • /
    • 2016
  • In this paper, we introduce a method of scattering centers extraction using the polarimetric data. VIRAF software based on the PO (Physical Optics) and PTD(Physical Theory of Diffraction) were used to calculate the surface scattering and the edge or wedge scattering, respectively. In addition, by using the unitary transformation, 4-channel data based on the linear polarization basis were converted to 2-channel data based on the left/vertical-circular polarization basis, leading to data compression coherently. The scattering mechanism was analyzed in terms of the polarization states and different look angles by using the scattering center of a target extracted by the 2D RELAX algorithm.

A Polarimetric Study of Long-Period Comet C/2013 US10 (Catalina) and Estimation of Its Gas Contamination in Optical and Near-Infrared Wavelengths

  • Kwon, Yuna Grace;Ishiguro, Masateru;Kuroda, Daisuke;Hanayama, Hidekazu;Kawabata, Koji S.;Akitaya, Hiroshi;Itoh, Ryosuke;Nakaoka, Tatsuya
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.48.1-48.1
    • /
    • 2016
  • Polarimetric study of light scattering from cometary dust particles can provide us opportunity to decipher their characteristics, such as sizes, structures, compositions of dust grains, etc. Herein, we present the results of our polarimetric study of long-period comet, C/2013 US10 (Catalina), in optical and near-infrared wavelengths which appeared at large phase angle (52.7 degrees) around the mid-December, 2015. We performed polarimetric and spectroscopic observations with HONIR, attached to the 1.5-m telescope at Higashi-Hiroshima Observatory, on UT 2015 December 17-18 and also obtained optical imaging data sets by the Ishigakijima Astronomical Observatory (IAO) and Okayama Astrophysical Observatory (OAO) taken between 2014-2015. By measuring the intensities of gas emission lines with respect to dust continuum and considering transmittance of each filter, we estimated that the percentages of gas contamination are approximately 10 percents in $R_C$-band and 3 percents in $I_C$-band. With these results, we derive the degree of linear polarization scattered solely from dust components in the coma. At this presentation, we will compare the phase-angle dependence of the degree of linear polarization with those of previous archive data in a wide coverage of wavelengths from $R_C$-band to $K_S$-band. Finally, we are supposed to discuss the spatial variations in polarization within the coma.

  • PDF

Evaluation of hydrological applicability for rainfall estimation algorithms of dual-polarization radar (이중편파 레이더의 강우 추정 알고리즘별 수문학적 적용성 평가)

  • Lee, Myungjin;Lee, Choongke;Yoo, Younghoon;Kwak, Jaewon;Kim, Hung Soo
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.1
    • /
    • pp.27-38
    • /
    • 2021
  • Recently, many studies have been conducted to use the radar rainfall in hydrology. However, in the case of weather radar, the beam is blocked due to the limitation of the observation such as mountain effect, which causes underestimation of the radar rainfall. In this study, the radar rainfall was estimated using the Hybrid Sacn Reflectivity (HSR) technique for hydrological use of weather radar and the runoff analysis was performed using the GRM model which is a distributed rainfall-runoff model. As a result of performing the radar rainfall correction and runoff simulation for 5 rainfall events, the accuracy of the dual-polarization radar rainfall using the HSR technique (Q_H_KDP) was the highest with an error within 15% of the ground rainfall. In addition, the result of runoff simulation using Q_H_KDP also showed an accuracy of R2 of 0.9 or more, NRMSE of 1.5 or less and NSE of 0.5 or more. From this study, we examined the application of the dual-polarization radar and this results can be useful for studies related to the hydrological application of dual-polarization radar rainfall in the future.

Estimation of Electric Properties of Insulating Silicone Rubbers Added Reinforcing Fillers (보강성 충전제를 첨가한 절연용 실리콘 고무의 전기 특성 평가)

  • Lee, Sung-Ill
    • Elastomers and Composites
    • /
    • v.32 no.5
    • /
    • pp.309-317
    • /
    • 1997
  • Estimation of the dielectric properties of insulating silicone rubbers added reinforcing fillers $(SiO_2,\;0{\sim}140phr)$ are very important to investigate the polymer structure. The characteristies of the dielectric absorption in insulating silicone rubbers were studied in the frequency range from 30Hz to 1MHz at the temperature range from $0{\sim}170^{\circ}C$. In the case of non-filled specimen, the dielectric loss is due to the syloxane which is the main chain of silicone rubber at the low temperature below $50^{\circ}C$ and the frequency at 330Hz, and is due to methyl and vinyl radical over the frequency of 1MHz. It is confirmed that the methyl radical or the vinyl radical becomes thermal oxidation at the high temperature over $100^{\circ}C$ and then the dielectric disperssing owing to the carboxyl radical Is appeared. In the case of filled specimen, the dielectric constant is in creased with the additives of reinforcing fillers due to the effect of interfacial polarization explained by MWS(Maxwell-Wagner-Sillars)'s law. The dielectric loss is decreased by the disturbance of reinforcing fillers that is permeated between networks.

  • PDF

Efficiency Estimation of Toxicity Free Eire Resistance Cable

  • Yoon, Hun-Ju;Hon, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.3 no.3
    • /
    • pp.34-38
    • /
    • 2002
  • In this paper, efficiency estimation of toxicity fee fire resistance cable experiments was measured smoke density of toxicity free fire resistance polyolefin insulation material and electric field dependence of tree shape in low density polyethylene (LDPE). One of the most serious causes of failure in high-voltage cables, can be an electrical discharge across an internal gab or void in the insulating material. Treeing due to partial discharge is one of the main causes of breakdown in the insulating materials and reduction of the insulation life. Therefore the necessity for establishing a method to diagnose the aging of insulation materials and to predict the breakdown of insulation and research of the fire resistance character has become important. First, we have studied on electric field dependence of tree shape in LDPE about treeing phenomena occurring on the high electrical field. Second, the measurement method is the attenuation quantity of irradiation by smoke accumulating with in a closed chamber due to non-flaming heat decomposition and flaming combustion. A main cause of fire-growth and generating toxic gas when, it bums, should be dealt with great care in life. safety design. The fire gases were occurred carbon monoxide and decomposition than in polyolefin due to incomplete combustion of PVC, which has high content of carbon in chemical compound.

Estimation of Paddy Rice Growth Parameters Using L, C, X-bands Polarimetric Scatterometer (L, C, X-밴드 다편파 레이더 산란계를 이용한 논 벼 생육인자 추정)

  • Kim, Yi-Hyun;Hong, Suk-Young;Lee, Hoon-Yol
    • Korean Journal of Remote Sensing
    • /
    • v.25 no.1
    • /
    • pp.31-44
    • /
    • 2009
  • The objective of this study was to measure backscattering coefficients of paddy rice using a L-, C-, and X-band scatterometer system with full polarization and various angles during the rice growth period and to relate backscattering coefficients to rice growth parameters. Radar backscattering measurements of paddy rice field using multifrequency (L, C, and X) and full polarization were conducted at an experimental field located in National Academy of Agricultural Science (NAAS), Suwon, Korea. The scatterometer system consists of dual-polarimetric square horn antennas, HP8720D vector network analyzer ($20\;MHz{\sim}20\;GHz$), RF cables, and a personal computer that controls frequency, polarization and data storage. The backscattering coefficients were calculated by applying radar equation for the measured at incidence angles between $20^{\circ}$ and $60^{\circ}$ with $5^{\circ}$ interval for four polarization (HH, VV, HV, VH), respectively. We measured the temporal variations of backscattering coefficients of the rice crop at L-, C-, X-band during a rice growth period. In three bands, VV-polarized backscattering coefficients were higher than hh-polarized backscattering coefficients during rooting stage (mid-June) and HH-polarized backscattering coefficients were higher than VV-, HV/VH-polarized backscattering coefficients after panicle initiation stage (mid-July). Cross polarized backscattering coefficients in X-band increased towards the heading stage (mid-Aug) and thereafter saturated, again increased near the harvesting season. Backscattering coefficients of range at X-band were lower than that of L-, C-band. HH-, VV-polarized ${\sigma}^{\circ}$ steadily increased toward panicle initiation stage and thereafter decreased, and again increased near the harvesting season. We plotted the relationship between backscattering coefficients with L-, C-, X-band and rice growth parameters. Biomass was correlated with L-band hh-polarization at a large incident angle. LAI (Leaf Area Index) was highly correlated with C-band HH- and cross-polarizations. Grain weight was correlated with backscattering coefficients of X-band VV-polarization at a large incidence angle. X-band was sensitive to grain maturity during the post heading stage.

Device Characteristics of MFSFET with the Fatigue of the Ferroelectric Thin Film (강유전박막의 피로현상을 고려한 MFSFET 소자의 특성)

  • 이국표;강성준;윤영섭
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.191-194
    • /
    • 1999
  • Switching behaviour of the ferroelectric thin film and device characteristics of the MFSFET (Metal-Ferroelectric-Semiconductor FET) are simulated with taking into account the accumulation of oxygen vacancies near interface between the ferroelectric thin film and the bottom electrode caused by the progress of fatigue. We show net switching current decreases due fatigue in the switching model. It indicates that oxygen vacancy strongly suppresses polarization reversal. The difference of saturation drain current of the device before fatigue is shown by the dual threshold voltages in I$_{D}$-V$_{D}$ curve as 6㎃/$\textrm{cm}^2$ and decreases as much as 50% after fatigue. Our simulation model is expected to play an important role in estimation of the behavior of MFSFET device with various ferroelectric thin films.lms.

  • PDF