• Title/Summary/Keyword: point-of-care diagnostic

Search Result 56, Processing Time 0.021 seconds

Implementation of point-of-care platforms for rapid detection of porcine circovirus type 2

  • Chiao-Hsu Ke;Mao-Yuan Du;Wang-Ju Hsieh;Chiu-Chiao Lin;James Mingjuh Ting;Ming-Tang Chiou;Chao-Nan Lin
    • Journal of Veterinary Science
    • /
    • v.25 no.2
    • /
    • pp.28.1-28.11
    • /
    • 2024
  • Background: Porcine circovirus type 2 (PCV2) infection is ubiquitous around the world. Diagnosis of the porcine circovirus-associated disease requires clinic-pathological elements together with the quantification of viral loads. Furthermore, given pig farms in regions lacking access to sufficient laboratory equipment, developing diagnostic devices with high accuracy, accessibility, and affordability is a necessity. Objectives: This study aims to investigate two newly developed diagnostic tools that may satisfy these criteria. Methods: We collected 250 specimens, including 170 PCV2-positive and 80 PCV2-negative samples. The standard diagnosis and cycle threshold (Ct) values were determined by quantitative polymerase chain reaction (qPCR). Then, two point-of-care (POC) diagnostic platforms, convective polymerase chain reaction (cPCR, qualitative assay: positive or negative results are shown) and EZtargex (quantitative assay: Ct values are shown), were examined and analyzed. Results: The sensitivity and specificity of cPCR were 88.23% and 100%, respectively; the sensitivity and specificity of EZtargex were 87.65% and 100%, respectively. These assays also showed excellent concordance compared with the qPCR assay (κ = 0.828 for cPCR and κ = 0.820 for EZtargex). The statistical analysis showed a great diagnostic power of the EZtargex assay to discriminate between samples with different levels of positivity. Conclusions: The two point-of-care diagnostic platforms are accurate, rapid, convenient and require little training for PCV2 diagnosis. These POC platforms can discriminate viral loads to predict the clinical status of the animals. The current study provided evidence that these diagnostics were applicable with high sensitivity and specificity in the diagnosis of PCV2 infection in the field.

Facile and Effective Detection of Vitamin C on a Paper Based Kit (종이기반 소수성 채널에서의 효율적이고 간편한 비타민 C의 검출기술 개발)

  • Hwang, Jangsun;Seo, Youngmin;Choi, Jonghoon
    • KSBB Journal
    • /
    • v.31 no.1
    • /
    • pp.46-51
    • /
    • 2016
  • Recently paper based diagnostic kits have drawn great interest in the point-of-care testing market (POCT). The paper based detection systems provide inexpensive, rapid and safe analyses for disease markers and/or pathogens. Vitamin C (i.e., ascorbic acid) regulates body's immune system as an antioxidant agent. Humans, however, do not have enough amounts of enzymes involved in the synthesis of vitamin C that it is required to be obtained from their diets (e.g., beverages and/or supplements). Here, we have prepared a paper based kit to detect the concentration of Vitamin C presented in commercially available beverages. The evaluation provides the fast, simple and accurate results for detecting Vitamin C in the prepared paper based kit.

Biosensors (바이오센서)

  • 김의락
    • KSBB Journal
    • /
    • v.15 no.5
    • /
    • pp.423-427
    • /
    • 2000
  • Intense research on biosensors has been performed in a number of different institution over the past 15 years, but relatively few commercial products have resultingly, the blood glucose sensor is a good example of a product which penetrated the market. However recently, the development of electrochemical and optical technologies has accelerated the turnover of the research as is illustrated by a rapid increase in the number of point-of-care diagnostic systems and analytical devices. Examples of such biosensors used in the fields of medical diagnostics, bioprocess control, and environmental monitoring are described, and summarized in an introduction to their characteristics, structures, and functions, given.

  • PDF

Review on Diagnostic Criteria of Neurasthenia : Suggesting Pathway of Culture-bound dieases

  • Lee, Myeong Hun;Kim, Yunna;Cho, Seung-Hun
    • Journal of Pharmacopuncture
    • /
    • v.20 no.4
    • /
    • pp.230-234
    • /
    • 2017
  • Objective: Neurasthenia is a disease which consists of increased fatigue or bodily weakness and exhaustion plus pantalgia, dizziness, headache and other symtoms relevant to autonomic nerve dysfunction. There are plenty of studies investigating the history of diagnostic criteria of neurasthenia, which is influenced by diverse cultural(or social) environment. The obejective of this study is to provide review of the previous studys on the changes of neurasthenia diagnoses in the context of local area to find meanings of these transition and improve health care for psychiatric patient. Methods: Literature review was conducted on studies demonstrating diagnostic criteria of neurasthenia with cultural(or social) environment. We investigated the literature reviews or observative studies which described alteration of diagnostic criteria of neurasthenia and assessed its significance. After selecting eligible studies, the authors read the articles and summarized the meaningful contents those were significant in clinical practice. Results: Transformation of Chinese Classification of Mental Disorder(CCMD) integrated with internationally utilized DSM-IV or ICD-10 is controversial about its significance in that it had limited effect on public health care due to the variables of sociocultural context, but primarily differentiated neurasthenia from other disorders. The latter one can be the directing point of the diagnostic criteria of other culture-bound diseases, which is the traits of not outstanding mood(or affect) than other neurotic disorders. Conclusion: As diagnostic criteria of neurasthenia varies, the significance of this variation is controversial, but could be the paragon of other culture-bound diseases.

Diagnostic Accuracy of the Quidel Sofia Rapid Influenza Fluorescent Immunoassay in Patients with Influenza-like Illness: A Systematic Review and Meta-analysis

  • Lee, Jonghoo;Song, Jae-Uk;Kim, Yee Hyung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.84 no.3
    • /
    • pp.226-236
    • /
    • 2021
  • Background: Although the Quidel Sofia rapid influenza fluorescent immunoassay (FIA) is widely used to identify influenza A and B, the diagnostic accuracy of this test remains unclear. Thus, the objective of this study was to determine the diagnostic performance of this test compared to reverse transcriptase-polymerase chain reaction. Methods: A systematic literature search was performed using MEDLINE, EMBASE, and the Cochrane Central Register. Pooled sensitivity, specificity, diagnostic odds ratio (DOR), and a hierarchical summary receiver-operating characteristic curve (HSROC) of this test for identifying influenza A and B were determined using meta-analysis. A sensitivity subgroup analysis was performed to identify potential sources of heterogeneity within selected studies. Results: We identified 17 studies involving 8,334 patients. Pooled sensitivity, specificity, and DOR of the Quidel Sofia rapid influenza FIA for identifying influenza A were 0.78 (95% confidence interval [CI], 0.71-0.83), 0.99 (95% CI, 0.98-0.99), and 251.26 (95% CI, 139.39-452.89), respectively. Pooled sensitivity, specificity, and DOR of this test for identifying influenza B were 0.72 (95% CI, 0.60-0.82), 0.98 (95% CI, 0.96-0.99), and 140.20 (95% CI, 55.92-351.54), respectively. The area under the HSROC for this test for identifying influenza A was similar to that for identifying influenza B. Age was considered a probable source of heterogeneity. Conclusion: Pooled sensitivities of the Quidel Sofia rapid influenza FIA for identifying influenza A and B did not quite meet the target level (≥80%). Thus, caution is needed when interpreting data of this study due to substantial betweenstudy heterogeneity.

Analysis of Blood Cell Images Using Smartphone-based Mobile SmartScope (스마트폰 기반 Mobile SmartScope를 이용한 혈구 영상 분석)

  • Park, Choonho;Cho, Myoung-Ock;Lee, Donghee;Kim, Jung Kyung
    • Journal of the Korean Society of Visualization
    • /
    • v.10 no.2
    • /
    • pp.25-31
    • /
    • 2012
  • High-performance smartphones, equipped with a digital camera and an application software, can render conventional bench-top laboratory instruments mobile at affordable costs. As the smartphone-based devices are portable and wireless, they have wide applications especially in providing point-of-care (POC) tests in resource-constrained areas. We developed a hand-held diagnostic system, Mobile SmartScope, which consists of a small optical unit integrated with a smartphone. The performance of the SmartScope was favorably compared with that of conventional light microscopy in detecting and quantifying red blood cells. We also evaluated the fluorescence detection limit of the SmartScope incorporated with a blue light-emitting diode and appropriate optical filters by using fluorescently labeled microbeads for intensity calibration.

Recent Advances in a Microfluidic Paper-based Analytical Devices and its Point of Care Testing Applications (종이기반 미세유체 분석소자를 활용한 현장검사 기술과 그 응용)

  • Yoo, Yong Kyoung;Kim, Cheonjung;Lee, Junwoo;Lee, Jeong Hoon
    • Ceramist
    • /
    • v.21 no.3
    • /
    • pp.293-301
    • /
    • 2018
  • Paper-based analytical devices (${\mu}PAD$) are highly advantageous for portable diagnostic systems owing to their low costs and ease of use. ${\mu}PADs$ are considered as the best candidates for realizing the World Health Organization (WHO) ASSURED criteria: affordable, sensitive, specific, user-friendly, rapid and robust, equipment-free, and deliverable to end users. However, they have several limitations such as low sensitivity and accuracy. This article reports a mini review for a micro-fluidic paper-based analytical devices (${\mu}PAD$), especially for addressing low sensitivity and accuracy issues.

An Evaluation of a New Quantitative Point-of Care Diagnostic to Measure Glucose-6-phosphate Dehydrogenase Activity

  • Bahk, Young Yil;Ahn, Seong Kyu;Jeon, Heung Jin;Na, Byoung-Kuk;Lee, Sung-Keun;Shin, Ho-Joon
    • Parasites, Hosts and Diseases
    • /
    • v.60 no.4
    • /
    • pp.281-288
    • /
    • 2022
  • Malaria continues to be one of the most crucial infectious burdens in endemic areas worldwide, as well as for travelers visiting malaria transmission regions. It has been reported that 8-aminoquinolines are effective against the Plasmodium species, particularly primaquine, for anti-hypnozoite therapy in P. vivax malaria. However, primaquine causes acute hemolytic anemia in individuals with glucose-6-phosphate dehydrogenase (G6PD) deficiency. Therefore, G6PD deficiency testing should precede hypnozoite elimination with 8-aminoquinoline. Several point-of-care devices have been developed to detect G6PD deficiency. The aim of the present study was to evaluate the performance of a novel, quantitative G6PD diagnostics based on a metagenomic blue fluorescent protein (mBFP). We comparatively evaluated the sensitivity and specificity of the G6PD diagnostic modality with standard methods using 120 human whole blood samples. The G6PD deficiency was spectrophotometrically confirmed. The performance of the G6PD quantitative test kit was compared with that of a licensed control medical device, the G6PD strip. The G6PD quantitative test kit had a sensitivity of 95% (95% confidence interval (CI): 89.3-100%) and a specificity of 100% (95% CI: 94.3-100%). This study shows that the novel diagnostic G6PD quantitative test kit could be a cost-effective and time-efficient, and universally mandated screening tool for G6PD deficiency.

Study of The Area of Nursing Need by the Family Developmental Stage (가족발달단계에 따른 간호요구영역에 관한 연구)

  • 최부옥
    • Journal of Korean Academy of Nursing
    • /
    • v.7 no.2
    • /
    • pp.43-59
    • /
    • 1977
  • The Community Health Service considers the family as a service unit and places the emphasis of its service on the health problems and the nursing needs of the family rather than the individual. From the conceptual point of view that tile community health service is both health maintenance and health promotion of the family, the community health nurse should have a knowledge of the growth and development of the family and be responsible for the comprehensive support of normal family development. The community health nurse often is in a position to make a real contribution to normal family development. In order to investigate the relationship between the areas of nursing need and family development, the following objectives were established 1. To discover the general characteristics of the study population by the stage of family development. 2. To discover specific nursing needs in relation to the family developmental stage, and to determine the intensity of the nursing needs and the ability of the family to cope with these needs. 3. To discover overall family health nursing problems in relation to the family developmental stage and determine the intensity of the nursing need and the problem solving ability of family. Definitions : The family developmental stages as classified by Dually were used stage 1. Married couples(without children) stage 2. Childbearing Families (oldest child birth to 30 months of age) stage 3. Families with preschool children (oldest child 2½-to 6 years) stage 4. Families with schoolchildren (oldest child 6 to 13 years). stage 5. Families with teenagers (oldest child 13 to 20 years) stage 6. Families as launching centers (first child gone to last child′s leaving home). stage 7. Middle- aged parents (empty nest to retirement) stage 8. Aging family member (retirement to death of both spouses) The areas of nursing need were defined as those used in the study, "A Comprehensive Study about Health and Nursing Need and a Social Diagram of the Community", by tile Nursing research Institute and Center for population. and Family Planning, July 1974. The study population defiled and selected were 260 nuclear families ill two myron of Kang Hwa Island. Percent, mean value and F- test were utilized in tile statistical analysis of the study result. Findings : 1. General characteristics of the study population by tile family developmental stage ; 1)The study population was distributed by the family developmental stage as follows : stage 1 : 3 families stage 2 : 13 families stage 3 : 24 families stage 4 : 41 families stage 5 : 50 families stage 6 : 106 families stage 7 : 13 families stage 8 : 10 families 2) Most families had 4 or 5 members except for those in stage, 1, 7, and 8. 3) The parents′ present age was older in the higher developmental stage and their age at marriage was also younger in the higher developmental stages. 4) The educational level of parents was primarily less than elementary school irrespective of the developmental stage. 5) More than half of parents′ occupations were listed as laborers irrespective of the developmental stage, 6) More than half of the parents were atheists irrespective of the developmental stage. 7) The higher the developmental stage(from stage 2 to stage 6 ), the wider the distribution of children′s ages. 8) More than half of the families were of middle or lower socio-economic level. 2. Problems in specific areas of nursing need by family developmental stage, the intensity of nursing need and the problem solving ability of the family : 1) As a whole, many problems, irrespective of the developmental stage, occurred in tile areas of Housing and Sanitation, Eating Patterns, Housekeeping, Preventive Measures and Dental care. Problems occurring ill particular stages included the following ; stage 1 : Prevention of Accident stage 2 : Preventive Vaccination, Family Planning. stage 3 : Preventive Vaccination, Maternal Health, Family Planning, Health of Infant and Preschooler. stage 4, 5 : Preventive Vaccination, Family Planning, Health of School Children. stage 6 : Preventive Vaccination, Health of School Children. 2) The intensity of the nursing need in the area of Acute and Chronic Diseases was generally of moderate degree or above irrespective of the developmental stages except for stage 1. Other areas of need listed as moderate or above were found in the following stages: stage 1 : Maternal Health stage 3 . Horsing and Sanitation, Prevention of Accident. stage 4 . Housing and Sanitation. stage 5 : Housing and Sanitation, Diagnostic and Medical Care. stage 6 : Diagnostic and Medical care stage 7 : Diagnostic and Medical Care, Housekeeping. stage 8 : Housing and Sanitation, Prevention of Accident, Diagnostic and Medical Care, Dental Care, Eating Patterns, Housekeeping. 3) Areas of need with moderate problem solving ability or less were as follows : stage 1 : Diagnostic and Medical Care, Maternal Health. stage 2 : Prevention of Accident, Acute and Chronic Disease, Dental Care. stage 3 : Housing and Sanitation, Acute and Chronic Disease, Diagnostic and Medical Care, Preventive Measure, Dental Care, Maternal Health, Health of Infant and preschooler, Eating Patterns. stage 4 : Housing and Sanitation, Prevention of Accident, Diagnostic and Medical Care, Preventive Measure, Dental Care, Maternal Health, Health of New Born, Health of Infant and Preschooler, Health of school Children, Eating Patterns, Housekeeping. stage 5 . Housing and Sanitation, Prevention of Accident, Acute and Chronic Disease, Diagnostic and Medical Care, Preventive Measure, Dental Care, Preventive Vaccination, Maternal Health, Eating Patterns. stage 7, 8 : Housing and Sanitation, Prevention of Accident, Acute and Chronic Disease, Diagnostic and Medical Care, Preventive Measures, Dental Care, Preventive Vaccination, Eating Patterns , Housekeeping. Problem occurrence, the degree of nursing need and the degree of problem solving ability 1 nursing need areas for the family as a whole were as follows : 1) The higher the stages(except stage 1 ), the lower the rate of problem occurrence. 2) The higher the stage becomes, the lower the intensity of the nursing need becomes. 3) The higher the stages (except stages 7 and 8), the higher. the problem solving ability. Conclusions ; 1) When the nursing care plan for the family is drawn up, depending upon the stage of family development, higher priority should be give to nursing need areas ① at which problems were shown to occur ② where the nursing need is shown to be above moderate degree and ③ where the problem solving ability was shown to be of moderate degree. 2) The priority of the nursing service should be Placed ① not on those families in the high developmental stage but on those families in the low developmental stage ② and on those areas of need shown in stages 7 and 8 where the degree nursing need was high and the ability to cope low.

  • PDF

Evaluation of the Accuracy of the $EasyTest^{TM}$ Malaria Pf/Pan Ag, a Rapid Diagnostic Test, in Uganda

  • Chong, Chom-Kyu;Cho, Pyo Yun;Na, Byoung-Kuk;Ahn, Seong Kyu;Kim, Jin Su;Lee, Jin-Soo;Lee, Sung-Keun;Han, Eun-Taek;Kim, Hak-Yong;Park, Yun-Kyu;Cha, Seok Ho;Kim, Tong-Soo
    • Parasites, Hosts and Diseases
    • /
    • v.52 no.5
    • /
    • pp.501-505
    • /
    • 2014
  • In recent years, rapid diagnostic tests (RDTs) have been widely used for malaria detection, primarily because of their simple operation, fast results, and straightforward interpretation. The Asan $EasyTest^{TM}$ Malaria Pf/Pan Ag is one of the most commonly used malaria RDTs in several countries, including Korea and India. In this study, we tested the diagnostic performance of this RDT in Uganda to evaluate its usefulness for field diagnosis of malaria in this country. Microscopic and PCR analyses, and the Asan $EasyTest^{TM}$ Malaria Pf/Pan Ag rapid diagnostic test, were performed on blood samples from 185 individuals with suspected malaria in several villages in Uganda. Compared to the microscopic analysis, the sensitivity of the RDT to detect malaria infection was 95.8% and 83.3% for Plasmodium falciparum and non-P. falciparum, respectively. Although the diagnostic sensitivity of the RDT decreased when parasitemia was ${\leq}500\;parasites/{\mu}l$, it showed 96.8% sensitivity (98.4% for P. falciparum and 93.8% for non-P. falciparum) in blood samples with parasitemia ${\geq}100\;parasites/{\mu}l$. The specificity of the RDT was 97.3% for P. falciparum and 97.3% for non-P. falciparum. These results collectively suggest that the accuracy of the Asan $EasyTest^{TM}$ Malaria Pf/Pan Ag makes it an effective point-of-care diagnostic tool for malaria in Uganda.