• 제목/요약/키워드: point-contact

검색결과 1,217건 처리시간 0.028초

Multi-point displacement monitoring of bridges using a vision-based approach

  • Ye, X.W.;Yi, Ting-Hua;Dong, C.Z.;Liu, T.;Bai, H.
    • Wind and Structures
    • /
    • 제20권2호
    • /
    • pp.315-326
    • /
    • 2015
  • To overcome the drawbacks of the traditional contact-type sensor for structural displacement measurement, the vision-based technology with the aid of the digital image processing algorithm has received increasing concerns from the community of structural health monitoring (SHM). The advanced vision-based system has been widely used to measure the structural displacement of civil engineering structures due to its overwhelming merits of non-contact, long-distance, and high-resolution. However, seldom currently-available vision-based systems are capable of realizing the synchronous structural displacement measurement for multiple points on the investigated structure. In this paper, the method for vision-based multi-point structural displacement measurement is presented. A series of moving loading experiments on a scale arch bridge model are carried out to validate the accuracy and reliability of the vision-based system for multi-point structural displacement measurement. The structural displacements of five points on the bridge deck are measured by the vision-based system and compared with those obtained by the linear variable differential transformer (LVDT). The comparative study demonstrates that the vision-based system is deemed to be an effective and reliable means for multi-point structural displacement measurement.

Development of a Handheld Sheet Resistance Meter with the Dual-configuration Four-point Probe Method

  • Kang, Jeon-Hong;Lee, Sang-Hwa;Yu, Kwang-Min
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권3호
    • /
    • pp.1314-1319
    • /
    • 2017
  • A handheld sheet resistance meter that can easily and quickly measure the sheet resistance of indium tin oxide films was developed. The dual-configuration four-point probe method was adopted for this instrument, which measured sheet resistance in the range from $0.26{\Omega}/sq$. to $2.6k{\Omega}/sq$. with 0.3 % ~ 0.5 % uncertainty. The screen of the instrument displayed the sheet resistance when the probe was in contact with the sample surface and the value continued to be displayed during the probe contact. Even after separating the probe from the surface, the value was still displayed on the screen and could be read easily. A feature of the instrument was the use of the dual-configuration technique to reduce edge effects markedly compared with the single-configuration technique and its ease of operation without applying correction factors for sample size and thickness.

비접촉식 자외선 반응조에서 자외선 강도 분포의 광학적 특성 (Optical characteristics of the UV intensity distribution in a non-contact type UV photoreactor)

  • 전화봉;윤정원;김성홍
    • 상하수도학회지
    • /
    • 제26권2호
    • /
    • pp.257-264
    • /
    • 2012
  • The concept of a non-contact type of UV disinfection system was introduced in this study. UV lamps and their quartz sleeves hang over the water surface and there is no interface between the sleeve and water. Obviously, there is no fouling. Based on optical laws and other UV distribution models, a detail mathematical model for a non-contact type UV disinfection system was developed in this study. Pathway length of UV light in a non-contact type photoreactor is longer than that in a submerged type photoreactor because the light is more refractive while passing through 3 interfaces of medium. But the pathway length passing through the water media is not significantly longer than that in a submerged type photoreactor so, the absorption of UV light by water is not significantly different from the other system. Due to the reflection effect, UV intensity is rapidly decreased as the horizontal distance from the light source is increased. The reflective attenuation in a non-contact type photoreactor is higher than that in a submerged type photoreactor. These mean that the short photoreactor is advantageous than the narrow-long photoreactor for the non-contact type photoreactor in an optical point of view.

선 충격 량과 공의 회전 속도와의 상관관계 (Correlation between the linear impulse and ball spin rate)

  • 노우진;이종원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.870-874
    • /
    • 2007
  • Golf ball spin rate after impact with club is created by the contact force, which is greatly influenced by ball and club mass, material, impact speed, and club loft angle. Previous studies showed that the contact force is determined as the resultant force of the reaction forces normal and tangential to the club face at the contact point. The normal force causes the compression and restitution of the ball, and the tangential force creates the spin. Especially, the tangential force takes either positive or negative values as the ball rolls and slides along the club face during impact. Although the positive and negative tangential forces are known to create and reduce the back spin rate, respectively, the mechanism of ball spin creation has not yet been discussed in detail. It is shown in this work that the linear impulse of the tangential force is directly related to generation of back spin rate of golf ball. The linear impulse can be calculated from the tangential force, which depends upon many factors such as ball and club mass, material, impact speed, and club loft angle. In this research, the influence of the contact force between golf club and ball is investigated to analyze the mechanism of impact. For this purpose, the contact force and the contact time at impact between golf club head and ball are computed using FEM.

  • PDF

선 충격량과 공의 회전 속도와의 상관관계 (Correlation between the Linear Impulse and Ball Spin Rate)

  • 노우진;이종원
    • 한국소음진동공학회논문집
    • /
    • 제17권11호
    • /
    • pp.1127-1132
    • /
    • 2007
  • Golf ball spin rate after impact with club is created by the contact force, which is greatly influenced by ball and club mass, material, impact speed, and club loft angle. Previous studies showed that the contact force is determined as the resultant force of the reaction forces normal and tangential to the club face at the contact point. The normal force causes the compression and restitution of the ball, and the tangential force creates the spin. Especially, the tangential force takes either positive or negative values as the ball rolls and slides along the club face during impact. Although the positive and negative tangential forces are known to create and reduce the back spin rate, respectively, the mechanism of ball spin creation has not yet been discussed in detail. It is shown in this work that the linear impulse of the tangential force is directly related to generation of back spin rate of golf ball. The linear impulse can be calculated from the tangential force, which depends upon many factors such as ball and club mass, material, impact speed, and club loft angle. In this research, the influence of the contact force between golf club and ball is investigated to analyze the mechanism of impact. For this purpose, the contact force and the contact time at impact between golf club head and ball are computed using FEM.

종자계형 진공 인터럽터에서 접점전극 슬릿의 영향에 관한 연구 (A Study on the Effect of the Contact Electrode Slits in the Vacuum Interrupter with Axial Magnetic Field Type)

  • 하덕용;강형부;최승길;최경호
    • 한국전기전자재료학회논문지
    • /
    • 제15권9호
    • /
    • pp.822-829
    • /
    • 2002
  • This paper deals with the distribution characteristics of the current density and axial magnetic flux density for each slits made on the contact electrode in the vacuum interrupter with axial magnetic field type using 3-dimension finite element analysis. It has been known that the presence of an axial magnetic field parallel to the current flow in the arc plasma can increase the high current breaking capacity of vacuum interrupter by carrying out the arc plasma from constricted mode to diffusion mode. The axial magnetic field is created of itself by current flow in the segments of coil electrode behind the contact electrode. The analyzed results show that if the slits are made in the contact electrode, they can increase the current density and axial magnetic flux density in the contact electrode surface and at the gap distance, which is due to decrease the effect of eddy currents flowing in the contact electrode. The phase shift due to eddy currents, defined 3s time difference between the maximum value of current and axial magnetic field, is decreased still more by increasing the number of slits made in the contact electrode at the center point of gap distance. These results demonstrate that 3-dimension finite element analysis has a great deal of merits in the development and evaluation of new electrode at the design of vacuum interrupter.

보철물 수복 형태에 따른 T-Scan Novus와 Dental prescale II를 이용한 교합력 평가 활용 증례 (Evaluation of occlusal strength using T-Scan Novus and Dental prescale II in dental prosthodontic treatments: A case report)

  • 최수현;최유성;이종혁;하승룡
    • 대한치과보철학회지
    • /
    • 제61권2호
    • /
    • pp.160-178
    • /
    • 2023
  • 보철 치료 시 교합관계의 진단과 분석은 중요한 요소 중 하나이다. 치료 시행 전 면밀한 교합분석 및 평가가 선행되어 안정적인 악간 관계를 회복시켜 주어야 하며, 치료 과정 및 정기 검진 시에도 이에 대한 평가는 필수적이다. 최근, 치과용 기기와 디지털 처리 방식의 발달로 환자의 교합관계를 기록할 수 있는 새로운 정량적 분석 방법들이 소개되고 있다. 그 중 T-Scan Novus (Tekscan Inc., S. Boston, MA, USA)는 압력측정센서를 이용하여 상하악 치아의 초기접촉점과 교합접촉점의 상대적인 강도를 나타내며 치아의 교합접촉 시간, 교합력의 전후방, 좌우균형을 비교할 수 있다. Dental prescale II (GC Co., Tokyo, Japan)는 압력감지필름을 이용하여 교합접촉점을 스캔하여 접촉점의 밀도를 분석하는 방법으로 최대한 자연스러운 교합상태 치열의 교합력 분포와 강도를 측정할 수 있다. 환자의 치아 상실 부위와 범위에 따라 4-unit 고정성 국소의치, 가철성 국소의치, 총의치, 완전구강회복술을 시행하였다. 적절한 교합 분석을 위해, 초진, 각 치료 단계, 치료 직후 및 정기검진 시의 환자의 교합을 T-Scan Novus와 Dental prescale II를 이용하여 정량적으로 비교, 평가하였다. 보철수복 치료과정에서 교합 분석에 대한 이해도를 제고할 수 있었고, 기능 및 심미적으로 환자와 술자 모두 만족할 만한 결과를 얻었기에 이를 보고하고자 한다.