• Title/Summary/Keyword: point source model

Search Result 587, Processing Time 0.033 seconds

Effect of Acupuncture applied to Hand Yang Meridian on the Rat Model of Ankle Sprain Pain (수양경(手陽經) 경혈(經穴) 자침(刺鍼)이 백서(白鼠)의 족과 염좌(捻挫) 통증(痛症)에 미치는 영향(影響))

  • Kim, Il;An, Sung-Hun;Koo, Sung-Tae;Kim, Sun-Young;Kim, Kyung-Sik;Sohn, In-Chul
    • Korean Journal of Acupuncture
    • /
    • v.21 no.4
    • /
    • pp.69-82
    • /
    • 2004
  • Objectives : In the present study, the effect of electroacupuncture (EA) applied to hand yang meridian on the ankle sprain model was examined. Methods & Results : A common source of persistent pain in humans is the lateral ankle sprain. To model this condition, the rat's right ankle was bent repeatedly, overextending lateral ligaments, for 4 min under halothane anesthesia. The rat subsequently showed swelling of the ankle and a reduced stepping force of the affected limb for the next several days. The reduced stepping force of the limb was presumably due to a painful ankle. EA was applied to the several acupuncture point on the contralateral forelimb for 30 min under gaseous anesthesia. After the termination of EA, behavioral tests measuring stepping force were periodically conducted during the next 4 h. EA applied to SI-6 point produced a significant improvement of stepping force of the sprained foot lasting for at least 2 h. However, neigher LI-4 point nor TE-3 point produced any significant increase of weight bearing force. The improvement of stepping pressure was interpreted as an analgesic effect. The analgesic effect was specific to the acupuncture point since the analgesic effect on the ankle sprain pain model could not be mimicked by EA applied to a nearby point, LI-4 or TE-3. The analgesic effect of EA applied to SI-6 was more powerful when EA was applied by low-frequency and high-intensity stimulation. In addition, this effect need to be stimulated more than 15 min. Conclusions : These data suggest that EA produces a potent analgesic effect on the ankle sprain pain model in the rat. This analgesic effect is produced by applying EA to a Tae-Yang meridian at opposite side from the painful area in a stimulus point-specific way.

  • PDF

Predicting of Ignition Time and Critical Distance for Ignition of Douglas fir by Radiant Heat of Incandescent Lamp (백열전구 복사열에 의한 미송판의 발화 임계거리 및 발화시간 예측)

  • Lee, Heung-Su;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.2
    • /
    • pp.18-25
    • /
    • 2016
  • The incandescent lamp is an electric light fixture with a tungsten filament heated to a high temperature, by passing an electric current through it, until it glows with visible light. The hot filament is protected from oxidation with a glass bulb that is filled with inert gas. The incandescent lamp has fire risk when combustible materials are close to its glass bulb. Because its lamp has the property which converts 90~95 percents of the electric power to heat energy. 2015 national fire statistics show that fires caused by lighting fixtures were 652 cases, and incandescent lamps(44 cases) and halogen lamps(53 cases) accounted for 15 percents in those of high heating light fixtures. Since incandescent lamp fires account for about 45 percents in the high heating light fixture, we could not overlook the fire risks by the incandescent lamp. Although many studies related with those have been conducted, incandescent lamp fires are continuously occurred. This study was carried out to study the fire risk of ignition of wood due to radiant heat of incandescent lamp. Radiant heat flux of the incandescent lamp was predicted by applying point source model, and critical distance for ignition of wood was calculated by applying integral model. The results from this study could applied to fire prevention activities related to light bulb, and it could be used in fire cause investigations related to radiant heat of incandescent lamp.

Source and LVis based coincidence summing correction in HPGe gamma-ray spectrometry

  • Lee, Jieun;Kim, HyoJin;Kye, Yong Uk;Lee, Dong Yeon;Kim, Jeung Kee;Jo, Wol Soon;Kang, Yeong-Rok
    • Nuclear Engineering and Technology
    • /
    • v.54 no.5
    • /
    • pp.1754-1759
    • /
    • 2022
  • The activity of gamma-ray emitting nuclides is calculated assuming that each gamma-ray is detected individually; thus, the magnitude of the coincidence summing signal must be considered during activity calculations. Here, the correction factor for the coincidence summing effect was calculated, and the detection efficiencies of two HPGe detectors were compared. The CANBERRA Inc. GC4018 high-purity Ge detector provided an estimate for the peak-to-total ratio using a point source to determine the coincidence summing correction factor. The ORTEC Inc. GEM60 high-purity Ge detector uses EFFTRAN in LVis to obtain the parameters of the detector and source model and the gamma-gamma and gamma-X match estimates, in order to determine the coincidence summing correction factor. Nuclide analyses, radioactivity comparisons, and analyses of reference material samples were performed utilizing certified reference materials to accurately determine the detection efficiencies. For both Co-60 and Y-88, the detection efficiency for a point source increased by an average of at least 12-13%, whereas the detection efficiency determined using LVis increased by an average of at least 13-15%. The calculated radioactivity values of the certified reference material and reference material samples were accurate to within 3% and 6% of the measured values, respectively.

Performance of ISC model-Predicting short-term concentrations around waste incinerator plant (ISC모델의 적용성 평가 - 소각장 주변지역의 단기농도예측)

  • 정상진
    • Journal of Environmental Science International
    • /
    • v.12 no.7
    • /
    • pp.809-816
    • /
    • 2003
  • The short-term version of Industrial Source Complex Model(ISCST3) was evaluated for estimating short-term concentrations using criteria pollutant(SO$_2$, NO$_2$, CO, PM10) data from emission inventory of Young Tong area in Suwon for the year 2002. The contribution of pollutant concentration from point, line, area sources was found 21.8, 76.5 and 1.6%. Statistical parameters, such as correlation coefficient, index of agreement(IA), normalized mean square error(NMSE) and fractional bias(FB) were calculated for each pollutants. The model performance were found good for PM10(82%) and NO$_2$(69%), but poor for SO$_2$(34%) and CO(13%).

The Center Locus Estimation of the Evoked Potential Distributions During Visual Stimulation in Human (시각 자극 동안의 유발성 전위분포 의 중심점 추적에 관한 연구)

  • Park, Gwang-Seok;Min, Byeong-Gu;Lee, Chung-Ung
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.20 no.3
    • /
    • pp.6-12
    • /
    • 1983
  • The visual evoked potentials were measured using 19 electrodes attached to the scalp in 5 normal and 4 abnormal subjects during visual stimulation and these data were sampled for computer processing with 500 Hz sampling frequency. The center of potential distributions and its time-dependent locus were estimated from these potential distributions using weighting matrix which was determined by the electrodes' position coordinates. In normal subjects these estimated electrical signals were shown to propagate from the frontal lobe to the occipital lobe of the cortex following the known visual pathway. In abnormal subjects, there were significant differences in these estimated propagation pathway. The relationships among this model, the point source model and the dipole source model were analyzed.

  • PDF

Gaussian Model for Laser Image on Curved Surface

  • Annmarie Grant;Sy-Hung Bach;Soo-Yeong Yi
    • Current Optics and Photonics
    • /
    • v.7 no.6
    • /
    • pp.701-707
    • /
    • 2023
  • In laser imaging, accurate extraction of the laser's center is essential. Several methods exist to extract the laser's center in an image, such as the geometric mean, the parabolic curve fitting, and the Gaussian curve fitting, etc. The Gaussian curve fitting is the most suitable because it is based on the physical properties of the laser. The width of the Gaussian laser beam depends on the distance from the laser source to the target object. It is assumed in general that the distance remains constant at a laser spot resulting in a symmetric Gaussian model for the laser image. However, on a curved surface of the object, the distance is not constant; The laser beam is narrower on the side closer to the focal point of the laser light and wider on the side closer to the laser source, which causes the distribution of the laser beam to skew. This study presents a modified Gaussian model in the laser imaging to incorporate the slant angle of a curved object. The proposed method is verified with simulation and experiments.

A PANORAMIC VIEW OF THE ASTEROIDS IN THE INNER SOLAR SYSTEM WITH AKARI

  • Usui, F.;Kuroda, D.;Muller, T.G.;Hasegawa, S.;Ishiguro, M.;Ootsubo, T.;Ueno, M.;AKARI SOSOS team, AKARI SOSOS team
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.4
    • /
    • pp.153-159
    • /
    • 2012
  • We constructed an unbiased asteroid catalog from the mid-infrared part of the All-Sky Survey with the Infrared Camera (IRC) on board AKARI. About 20% of the point source events recorded in the IRC All-Sky Survey observations were not used for the IRC Point Source Catalog in its production process because of a lack of multiple detection by position. Asteroids, which are moving objects on the celestial sphere, are included in these "residual events" We identified asteroids out of the residual events by matching them with the positions of known asteroids. For the identified asteroids, we calculated the size and albedo based on the Standard Thermal Model. Finally we had a new brand of asteroid catalog, which contains 5,120 objects, about twice as many as the IRAS asteroid catalog.

EXPERIMENTAL DEMONSTRATION OF ADVANTAGE OF MOTION INDUCED SYNTHETIC APERTURE RADIOMETER

  • Park, Hyuk;Kim, Sung-Hyun;Lee, Ho-Jin;Moon, Nam-Won;Yu, Hwan-Wook;NamGoong, Up;Sim, Won-Seon;Kim, Yong-Hoon
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.22-25
    • /
    • 2008
  • Aperture synthesis with platform motion has been presented as a useful tool to achieve the high spatial resolution imaging. Using a motion induced synthetic aperture radiometer (MISAR), a passive microwave image can be achieved with a small number of antennas. Moreover, the MISAR is capable of imaging better than the case without motion, using the same configuration of antenna array. With a platform motion, visibility can be sampled more efficiently, and as a result the imaging performance of the MISAR shows higher quality than the case without platform motion. In this paper, the advantage of MISAR is demonstrated experimentally. Using a laboratory model of inteferometric radiometer, the point source images are obtained under the condition with platform motion and without platform motion. In the experimental results, the point source response of the MISAR shows better quality of sidelobe level and beam efficiency than the case without platform motion.

  • PDF

Case study of the large switching software metrics and their fault analysis (대형 교환 소프트웨어의 복잡성과 고장분석 사례 연구)

  • 이재기;남상식;김창봉;이규대
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.10C
    • /
    • pp.887-901
    • /
    • 2002
  • Software management model divided into the software project model and design estimation model, software matrices model, reliability growth model, process improvement model(or process maturity model) etc. Among these software management models, software complexity model make an estimated of the product software. For a practice of software managed, need to guideline of the static analysis of software. Especially, Software complexity model introduced for the estimation of software quantity and program complexity. In case of measurement the software matrices, its need for us to analysis of software quality and products. On the other hand, we known that complexity program include many defects and consuming of source cost. So, we apply to complexity model using of the program complexity, control structure and volume matrices, interface metrics, process complexity metrics method. In this paper, we represent that the analysis of fault data detected during the system test. Also, we analysis of program control structure and interface, volume matrices in various aspect of switching software. Others, their results utilized similar of project and system development.

Change of Groundwater Quality derived from Contaminant Sources (오염원에 의한 지하수 수질의 변화)

  • Bae, Sang-Kuen
    • Journal of Environmental Science International
    • /
    • v.4 no.5
    • /
    • pp.75-75
    • /
    • 1995
  • In order to provide for the guidance on groundwater quality monitoring network design and also, to suggest the index to the solution of the contaminated groundwater remediation problems in the lake watershed, it is necessary to analyze the contaminant transport in the groundwater. The solute transport was analyzed in the lake watershed to investigate the behavior of the injected contaminant sources depend on the relationships between the point of contaminant sources and position of the lake. Three hypothetical groundwater flow systems, which is composed of a flow-through lake and two solute sources, were considered. The lakes located in the upper, middle, and lower portions of a watershed respectively. The transported contaminant was numerically simulated for five years by using MT3D contaminant transport model under the three-dimentional steady state conditions. From the above simulations, it can be concluded that the contaminant concentration was high as the contaminant source located at the upper position of a watershed, and the influence of the contaminant injection was large as the solute source located at the lower position. When the injection of contaminant was continued for one year without regard to the position of contaminant source and the lake, the influence of contaminant source was reached to bedrock.