A Study on the Hyperspectral Image Classification with the Iterative Self-Organizing Unsupervised Spectral Angle Classification (반복최적화 무감독 분광각 분류 기법을 이용한 하이퍼스펙트럴 영상 분류에 관한 연구)

  • Jo Hyun-Gee;Kim Dae-Sung;Yu Ki-Yun;Kim Yong-Il
    • Korean Journal of Remote Sensing
    • /
    • v.22 no.2
    • /
    • pp.111-121
    • /
    • 2006
  • The classification using spectral angle is a new approach based on the fact that the spectra of the same type of surface objects in RS data are approximately linearly scaled variations of one another due to atmospheric and topographic effects. There are many researches on the unsupervised classification using spectral angle recently. Nevertheless, there are only a few which consider the characteristics of Hyperspectral data. On this study, we propose the ISOMUSAC(Iterative Self-Organizing Modified Unsupervised Spectral Angle Classification) which can supplement the defects of previous unsupervised spectral angle classification. ISOMUSAC uses the Angle Division for the selection of seed points and calculates the center of clusters using spectral angle. In addition, ISOMUSAC perform the iterative merging and splitting clusters. As a result, the proposed algorithm can reduce the time of processing and generate better classification result than previous unsupervised classification algorithms by visual and quantitative analysis. For the comparison with previous unsupervised spectral angle classification by quantitative analysis, we propose Validity Index using spectral angle.

Study on the Crack and Thermal Degradation of GFRP for UPE Gelcoat Coated Underground Pipes Under the High Temperature Water-Immersion Environment (고온 수침 환경에서 UPE 겔코트 코팅된 지중 매설 파이프용 GFRP의 열화 및 크랙 발생 특성에 관한 연구)

  • Kim, Daehoon;Eom, Jaewon;Ko, Youngjong;Lee, Kang-Il
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.4
    • /
    • pp.169-177
    • /
    • 2018
  • Glass fiber reinforced polyester (GFRP) composites are widely used as structural materials in harsh environment such as underground pipes, tanks and boat hulls, which requires long-term water resistance. Especially, these materials might be damaged due to delamination between gelcoat and composites through an osmotic process when they are immersed in water. In this study, GFRP laminates were prepared by surface treatment of UPE (unsaturated polyester) gelcoat by vacuum infusion process to improve the durability of composite materials used in underground pipes. The composite surface coated with gelcoat was examined for surface defects, cracking, and hardness change characteristics in water-immersion environments (different temperatures of $60^{\circ}C$, $75^{\circ}C$, and $85^{\circ}C$). The penetration depth of cracks was investigated by micro CT imaging according to water immersion temperature. It was confirmed that cracks developed into the composites material at $75^{\circ}C$ and $85^{\circ}C$ causing loss of durability of the materials. The point at which the initial crack initiated was defined as the failure time and the life expectancy at $23^{\circ}C$ was measured using the Arrhenius equation. The results from this study is expected to be applied to reliability evaluation of various industrial fields where gelcoat is applied such as civil engineering, construction, and marine industry.

A Study on the Need for Separation of Software Completeness Appraisal and Software Ready-made Appraisal (소프트웨어 완성도 감정과 기성고 감정 분리 필요성에 대한 고찰)

  • Kim, DoWan
    • Journal of Software Assessment and Valuation
    • /
    • v.17 no.2
    • /
    • pp.11-17
    • /
    • 2021
  • In this study, problems of software completeness appraisal are pointed out and their solutions are presented by analyzing appraisal cases and judicial precedents. Completeness appraisal, ready-made appraisal, defect appraisal, and cost appraisal have been classified as and have been evaluated with extant software completeness appraisals. From a legal point of view, and in judicial precedents, however, there is a big difference between the definition of completeness and the completion rate. This is because the degree of completeness is evaluated under the premise that the software's development is complete, whereas the ready-made appraisal inspects the development progress of unfinished software. Often, in cases involving software completion rate, the total completion level is calculated by weighting each step of the software development process. However, completeness evaluations use the software's realization-operation as its sole criterion. In addition, another issue not addressed in existing software completeness appraisal cases is that there is no mention of who is responsible for software defects, whereas in case law, the responsible party is determined by finding who caused the dispute. In this paper, we systematically classify these problems, and present a novel evaluation method that separates software completeness evaluations from software completion evaluations.

Influence of kilovoltage- peak and the metal artifact reduction tool in cone-beam computed tomography on the detection of bone defects around titanium-zirconia and zirconia implants

  • Fontenele, Rocharles Cavalcante;Nascimento, Eduarda Helena Leandro;Imbelloni-Vasconcelos, Ana Catarina;Martins, Luciano Augusto Cano;Pontual, Andrea dos Anjos;Ramos-Perez, Flavia Maria Moraes;Freitas, Deborah Queiroz
    • Imaging Science in Dentistry
    • /
    • v.52 no.3
    • /
    • pp.267-273
    • /
    • 2022
  • Purpose: The aim of this study was to assess the influence of kilovoltage- peak (kVp) and the metal artifact reduction (MAR) tool on the detection of buccal and lingual peri-implant dehiscence in the presence of titanium-zirconia (Ti-Zr) and zirconia (Zr) implants in cone-beam computed tomography (CBCT) images. Materials and Methods: Twenty implant sites were created in the posterior region of human mandibles, including control sites (without dehiscence) and experimental sites (with dehiscence). Individually, a Ti-Zr or Zr implant was placed in each implant site. CBCT scans were performed using a Picasso Trio device, with variation in the kVp setting (70 or 90 kVp) and whether the MAR tool was used. Three oral radiologists scored the detection of dehiscence using a 5-point scale. The area under the receiver operating characteristic (ROC) curve, sensitivity, and specificity were calculated and compared by multi-way analysis of variance (α=0.05). Results: The kVp, cortical plate involved (buccal or lingual cortices), and MAR did not influence any diagnostic values (P>0.05). The material of the implant did not influence the ROC curve values(P>0.05). In contrast, the sensitivity and specificity were statistically significantly influenced by the implant material (P<0.05) with Zr implants showing higher sensitivity values and lower specificity values than Ti-Zr implants. Conclusion: The detection of peri-implant dehiscence was not influenced by kVp, use of the MAR tool, or the cortical plate. Greater sensitivity and lower specificity were shown for the detection of peri-implant dehiscence in the presence of a Zr implant.

A Study of Coloration of Topaz(I): Mineralogical and Chemical Study on the Topaz Selected from Some Localities of the World (토파즈의 人工着色 處理를 위한 硏究(I) : 世界 主要 産地別 토파즈의 鑛物學的 및 化學的 特性)

  • Han, Yi-Kyeong;Park, Maeng-Eon;Jang, Yong-Nam
    • Journal of the Mineralogical Society of Korea
    • /
    • v.5 no.2
    • /
    • pp.109-121
    • /
    • 1992
  • For the purpose of mineralogical and chemical study on the topazes from various localities of world(Brzail, China, India, Nigeria and Sri Lanka), electron microprobe analysis(EPMA), neutron activation analysis(NAA), X-ray diffractometry, Raman spectroscopy, etch test, scanning electron microscopy, refractive index, specific gravity, fluid inclusion were performed. The chemical composition in topaz was discussed along with its physical and structural properties. Variations in the unit-cell dimension and physical properties of topaz were found to have a close relations in the unit-cell dimension and physical properties of topaz were found to have a close relationship with extent of substitution of $OH^-\;for\;F^-$. According to neutron activation analyses, the trace elements had no effects on the physical properties of topaz. Raman spectra showed that the peaks of topaz were different in intensity from one locality to another. Etching defects in topaz includes negative crystal defect o point-bottom pit(India, Nigeria) and net work defect of curl-bottom pit(Brazil, China). Fluid inclusions in topaz may be classiffied into liquid $CO_2$-bearing inclusion, gaseous inclusion, halite, sylvite-bearing inclusion and liquid inclusion. The results of this study can be useful to devising artificial coloring methods for topaz with different mineralogical compositions.

  • PDF

Analysis of improvement directions on the Current Appraisal System of Public Records in Electronic Record Environments: Focusing on Appraisal Methods and Appraisal System (전자기록 환경 하의 현행 평가제도 개선방향 분석 - 평가방식 및 평가체제를 중심으로 -)

  • Kim, Myoung-Hun
    • The Korean Journal of Archival Studies
    • /
    • no.19
    • /
    • pp.103-151
    • /
    • 2009
  • Appraisal in electronic record environments is performed focusing on not content but function in which the records are created. Functional appraisal is practically supported in that electronic records composed of 0 and 1 of the bit-stream is unable to be evaluated individually. But the most important reason functional appraisal is performed in electronic record environments is that functional appraisal can select electronic records which assure business context and recordness, and need to run organization and perform business. In Korea, functional appraisal has adopted in course of renovation of national record and archive management system, but methods and logics of functional appraisal have numerous problems. To do so, this article discusses current appraisal system and methods of korea which has renovated confronting with electronic record environments, and then proposes the improvement directions on appraisal system and methods of Korea in electronic record environments from the perspective of long-term views. In this respect, this article proposes the improvement directions on current appraisal system and methods of Korea as follows. First, business functional analysis of each agency in functional appraisal should greatly strengthen. Second, it is necessary to devise proper methods for selecting primary values at current stage of electronic records, and to reinforce appraisal of records as knowledges and informations. Finally, functional appraisal, which inevitably carries out for appraising electronic records, has defects in aspect of selecting archives important in a national point of views. Therefore this article suggests the necessity of archival appraisal strategies that complement functional appraisal. This appraisal system is able to establish a base of the regime of archival appraisal which will harmonize primary value at current stage with secondary value at non-current stage in a national point of views.

The Study in Objectification of the diagnosis of Sasang Constitution(According to Analysis of the Past Questionnaires) (사상체질진단(四象體質診斷)의 객관화(客觀化)에 관한 연구(硏究)(기존(旣存) 설문지(說問紙)의 분석(分析)을 중심(中心)으로))

  • Kim, Young-woo;Kim, Jong-won
    • Journal of Sasang Constitutional Medicine
    • /
    • v.11 no.2
    • /
    • pp.151-183
    • /
    • 1999
  • The object of this study was 200 patients who had been treated in the Oriental Medical Hospital at Dong Eui Medical Center during 9 months from Jan. 1999 to sept. 1999. We proceeded the judgment of Sasang Constitution according to 'Questionnaire of Sasang Constitution Classification (I)', and 'Questionnaire of Sasang Constitution Classification II(QSCCII)' and the diagnosis by a medical specialist. The following conclusion were made in comparison with Sasang Constitution and Questionnaire. 1. We selected the 84 subjects what had the statistical value out of the 196 subjects('Questionnaire of Sasang Constitution Classification (I)' had the 71 subjects and 'Questionnaire of Sasang Constitution Classification II(QSCCII)', had the 121 subjects). And we selected again the 73 subjects('Questionnaire of Sasang Constitution Classification (I)', had the 33 subjects and 'Questionnaire of Sasang Constitution Classification II (QSCC II)' had the 40 subjects) out of the 84 subjects, because it had a repeated subjects. 2. We made the Questionnaire what has the 85 subjects, including the subjects what was approved its statistical value by 'A CLINICAL STUDY OF THE JUDGMENT OF SASANG CONSTITUTION ACCORDING TO QUESTIONNAIRE' and 'A CLINICAL STUDY OF THE TYPE OF DISEASE AND SYMPTOM ACCORDING TO SASANG CONSTITUTION CLASSIFICATION'. The subject what ask the physique and the body form was 7, the subject what ask the external appearance and the posture was 7, the subject what ask the habit and the character was 3, the subject what ask the physiology and the pathology was 3, the subject what ask the phenomenon that he has frequency was 4, the subject what ask the eating was 3, the subject what ask the symptom that he has frequency was 14, the subject what ask the work and the qualities-defects was 6, the subject what ask the friendly intercourse was 7, the subject what ask the usual mind was 5, the subject what ask the emotional inclination was I, the subject what ask the behavioral inclination was 10, the subject what ask the character was 15. 3. In the new Questionnaire, the subject what has relevance to Soyang was 84, the subject what has relevance to Soeum was 87, the subject what has relevance to Taeeum was 70. And we made the point of subject with the statistical ratio. The total point of Soyang was 7785.04, the total point of Soeum was 7742.80, the total point of Taeeum was 7746.60. 4. As a result of judgment of Sasang Constitution between the clinical diagnosis by a medical specialist and the new Questionnaire, the diagnostic accuracy of new Questionnaire was 73.33%. The diagnostic accuracy of Soyang was low, the others was high. And the Taeyang was excepted.

  • PDF

Research of Diffusion Bonding of Tungsten/Copper and Their Properties under High Heat Flux

  • Li, Jun;Yang, Jianfeng
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.14-14
    • /
    • 2011
  • W (tungsten)-alloys will be the most promising plasma facing armor materials in highly loaded plasma interactive components of the next step fusion reactors due to its high melting point, high sputtering resistance and low deuterium/tritium retention. The bonding technology of tungsten to Cu alloy was one of the key issues. In this paper, W/CuCrZr diffusion bonding has been performed successfully by inserting pure metal interlay. The joint microstructure, interfacial elements migration and phase composition were analyzed by SEM, EDS, XRD, and the joint shear strength and micro-hardness were investigated. The mock-ups were fabricated successfully with diffusion bonding and the cladding technology respectively, and the high heat flux test and thermal fatigue test were carried out under actively cooling condition. When Ni foil was used for the bonding of tungsten to CuCrZr, two reaction layers, Ni4W and Ni(W) layer, appeared between the tungsten and Ni interlayer with the optimized condition. Even though Ni4W is hard and brittle, and the strength of the joint was oppositely increased (217 MPa) due primarily to extremely small thicknesses (2~3 ${\mu}m$). When Ti foil was selected as the interlayer, the Ti foil diffused quickly with Cu and was transformed into liquid phase at $1,000^{\circ}C$. Almost all of the liquid was extruded out of the interface zone under bonding pressure, and an extremely thin residual layer (1~2 ${\mu}m$) of the liquid phase was retained between the tungsten and CuCrZr, which shear strength exceeded 160 MPa. When Ni/Ti/Ni multiple interlayers were used for bonding of tungsten to CuCrZr, a large number of intermetallic compound ($Ni_4W/NiTi_2/NiTi/Ni_3T$) were formed for the interdiffusion among W, Ni and Ti. Therefore, the shear strength of the joint was low and just about 85 MPa. The residual stresses in the clad samples with flat, arc, rectangle and trapezoid interface were estimated by Finite Element Analysis. The simulation results show that the flat clad sample was subjected maximum residual stress at the edge of the interface, which could be cracked at the edge and propagated along the interface. As for the rectangle and trapezoid interface, the residual stresses of the interface were lower than that of the flat interface, and the interface of the arc clad sample have lowest residual stress and all of the residual stress with arc interface were divided into different grooved zones, so the probabilities of cracking and propagation were lower than other interfaces. The residual stresses of the mock-ups under high heat flux of 10 $MW/m^2$ were estimated by Finite Element Analysis. The tungsten of the flat interfaces was subjected to tensile stresses (positive $S_x$), and the CuCrZr was subjected to compressive stresses (negative $S_x$). If the interface have a little microcrack, the tungsten of joint was more liable to propagate than the CuCrZr due to the brittle of the tungsten. However, when the flat interface was substituted by arc interfaces, the periodical residual stresses in the joining region were either released or formed a stress field prohibiting the growth or nucleation of the interfacial cracks. Thermal fatigue tests were performed on the mock-ups of flat and arc interface under the heat flux of 10 $MW/m^2$ with the cooling water velocity of 10 m/s. After thermal cycle experiments, a large number of microcracks appeared at the tungsten substrate due to large radial tensile stress on the flat mock-up. The defects would largely affect the heat transfer capability and the structure reliability of the mock-up. As for the arc mock-up, even though some microcracks were found at the interface of the regions, all microcracks with arc interface were divided into different arc-grooved zones, so the propagation of microcracks is difficult.

  • PDF

Prenatal Diagnosis of the 22q11.2 Duplication Syndrome

  • Lee, Moon-Hee;Park, So-Yeon;Lee, Bom-Yi;Choi, Eun-Young;Kim, Jin-Woo;Park, Ju-Yeon;Lee, Yeon-Woo;Oh, Ah-Rum;Lee, Shin-Young;Yang, Jae-Hyug;Ryu, Hyun-Mee
    • Journal of Genetic Medicine
    • /
    • v.6 no.2
    • /
    • pp.175-178
    • /
    • 2009
  • The 22q11.2 duplication syndrome is an extremely variable disorder with a phenotype ranging from normal to congenital defects and learning disabilities. Recently, the detection rate of 22q11.2 duplication has been increased by molecular techniques, such as array CGH. In this study, we report a familial case of 22q11.2 duplication detected prenatally. Her first pregnancy was terminated because of 22q11.2 duplication detected incidentally by BAC array CGH. The case was referred due to second pregnancy with same 22q11.2 duplication. We perfomed repeat amniocentesis for karyotype and FISH analysis. Karyotype analysis from amniocytes and parental lymphocytes were normal, while FISH analysis of interphase cells presented a duplication of 22q11.2 in the fetus and phenotypically normal mother. The fetal ultrasound showed grossly normal finding. After genetic counseling about variable phenotype with intrafamilial variability with 50% recurrence rate, the couple decided to continue the pregnancy. The newborn had no apparent congenital abnormalities until 2 weeks after birth. We recommend that family members of patients with a 22q11.2 duplication be tested by the interphase FISH analysis. Also, we point out the importance of genetic counseling and an evaluation of the clinical relevance of diagnostic test results.

  • PDF

SURFACE CHANCE OF EXTERNAL HEXAGON OF IMPLANT FIXTURE AND INTERNAL HEXAGON OF ABUTMENT AFTER REPEATED DELIVERY AND REMOVAL OF ABUTMENT (지대주의 반복적인 착탈에 따른 임플랜트 고정체의 external hexagon과 지대주 internal hexagon의 변화에 관한 연구)

  • Jung Seok-Won;Kim Hee-Jung;Chung Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.528-543
    • /
    • 2005
  • Statement of problem: Repeated delivery and removal of abutment cause some changes such as wear, scratch or defect of hexagonal structure. It may increase the value of rotational freedom(RF) between hexagonal structures. Purpose: The purpose of this study was to evaluate surface changes and rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment after repeated delivery and removal under SEM and toolmaker's microscope. Materials and methods: Implant systems used for this study were 3i and Avana. Seven pail's of implant fixture, abutment and abutment screws for each system were selected and all fixtures were perpendicularly mounted in liquid unsaturated polyesther with dental surveyor. Each one was embedded beneath the platform of fixture. Surfaces of hexagonal structure before repeated closing and opening of abutment were observed using SEM and rotational freedom was measured by using toolmaker's microscope. Each abutment was secured to the implant future by each abutment screw with recommended torque value using a digital torque controller and was repeatedly delivered and removed by 20 times respectively. After experiment, evaluation for the change of hexagonal structures and measurement of rotational freedom were performed. Result : The results were as follows; 1. Wear of contact area between implant fixture and abutment was considerable in both 3i and Avana system. Scratches and defects were frequently observed at the line-angle of hexagonal structures of implant fixture and abutment. 2. In the SEM view of the external hexagon of implant fixture, the point-angle areas at the corner edge of hexagon were severely worn out in both systems. It was more notable in the case of 3i systems than in that of Avana systems. 3. In the SEM view of the internal hexagon of abutment, Gingi-Hue abutment of 3i systems showed severe wear in micro-stop contacts that were machined into the corners to prevent rotation and cemented abutment of Avana systems showed wear in both surface area adjacent to the corner mating with external hexagon of implant fixture. 4 The mean values of rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment were 0.48$\pm$0.04$^{\circ}$ in pre-tested 3i systems and 1.18$\pm$0.25$^{\circ}$ after test, and 1.80$\pm$0.04$^{\circ}$ in pre-tested Avana systems and 2.61$\pm$0.16$^{\circ}$ after test. 5. Changes of rotational freedom after test shouted statistical)y a significant increase in both 3i and Avana systems(P<0.05, paired t-test). 6. Statistically, there was no significant difference between amount of increase in the rotational freedom of 3i systems and amount of increase in that of Avana ones(P>0.05, unpaired t-test). Conclusion: Conclusively, it was considered that repeated delivery and remove of abutment by 20 times would not have influence on screw joint stability. However, it caused statistically the significant change of rotational freedom in tested systems. Therefore, it is suggested that repeated delivery and remove of abutment should be minimal as possible as it could be and be done carefully Additionally, it is suggested that the means or treatment to prevent the wear of mating components should be devised.