• Title/Summary/Keyword: point defects

Search Result 497, Processing Time 0.029 seconds

Investigation of the Thermo-mechanical Crack Initiation of the Gas Turbine Casing Using Finite Element Analysis (유한요소해석을 이용한 가스터빈 케이싱 열피로 균열발생 해석)

  • Kang, M.S.;Yun, W.N.;Kim, J.S.
    • Journal of Power System Engineering
    • /
    • v.13 no.5
    • /
    • pp.52-58
    • /
    • 2009
  • A gas turbine consists of an upstream compressor and a downstream turbine with a combustion chamber, and also the compressor and the turbine are generally coupled using a single shaft. Many casing bolts are used to assemble two horizontally separated casings, the gas turbine casing and the compressor casing, in both of axial and vertical directions. Because drilled holes for casing bolts in vertical direction are often too close to drilled holes for casing bolts in axial direction, one can observe cracks in the area frequently during operations of a gas turbine. In this study of the root cause analysis for the cracking initiating from the drilled holes of the casings of a gas turbine, the finite element analysis(FEA) was applied to evaluate the thermal and mechanical characteristics of the casings. By applying the field operation data recorded from combined cycle power plants for FEA, thermal and thermo-mechanical characteristics of a gas turbine are analyzed. The crack is initiated at the geometrical weak point, but it is found that the maximum stress is relieved when the same type of cracks is introduced on purpose during FEA. So, it is verified that the local fracture could be delayed by machining the same type of defects near the hole for casing flange bolts of the gas turbine, where the crack is initiated.

  • PDF

Development of Portable Cardiopulmonary Support System (이동형 심폐보조시스템의 개발)

  • Lee, Hyuk-Soo;Min, Byoung-Goo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.1
    • /
    • pp.94-99
    • /
    • 2007
  • Many cases of acute cardiac shock and cardiac arrest in emergency room and ICU have been increasing. In this case, ECMO with centrifugal pump has been used generally. However, due to the heavy weight and big size, the system is not adequate for emergency cases. And other defects of this system are that membrane oxygenator's pressure is high and blood are exposed to the air. There was some tries of ECMO using pulsatile pump, but it was found that the weak point of these system is high peak pressure and hemolysis. The mechanism of twin pulsatile pump is that Membrane oxygenator Outlet Pump(MOP) make negative pressure when Membrane oxygenator Inlet Pump(MIP) provides high positive pressure, and the negative pressure will decrease positive pressure of Membrane Oxygenator. Our group analyzed this advantage through In-Vitro and 12 Cases In-Vivo test.

Wire Rope Fault Detection using Probability Density Estimation (확률분포추정기법을 이용한 와이어로프의 결함진단)

  • Jang, Hyeon-Seok;Lee, Young-Jin;Lee, Kwon-Soon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1758-1764
    • /
    • 2012
  • A large number of wire rope has been used in various inderstiries as Cranes and Elevators from expanding the scale of the industrial market. But now, the management of wire rope is used as manually operated by rope replacement from over time or after the accident.It is caused to major accidents as well as economic losses and personal injury. Therefore its time to need periodic fault diagnosis of wire rope or supply of real-time monitoring system. Currently, there are several methods has been reported for fault diagnosis method of the wire rope, to find out the feature point from extracting method is becoming more common compared to time wave and model-based system. This method has implemented a deterministic modeling like the observer and neural network through considering the state of the system as a deterministic signal. However, the out-put of real system has probability characteristics, and if it is used as a current method on this system, the performance will be decreased at the real time. And if the random noise is occurred from unstable measure/experiment environment in wire rope system, diagnostic criterion becomes unclear and accuracy of diagnosis becomes blurred. Thus, more sophisticated techniques are required rather than deterministic fault diagnosis algorithm. In this paper, we developed the fault diagnosis of the wire rope using probability density estimation techniques algorithm. At first, The steady-state wire rope fault signal detection is defined as the probability model through probability distribution estimate. Wire rope defects signal is detected by a hall sensor in real-time, it is estimated by proposed probability estimation algorithm. we judge whether wire rope has defection or not using the error value from comparing two probability distribution.

Development of rotational pulse-echo ultrasonic propagation imaging system capable of inspecting cylindrical specimens

  • Ahmed, Hasan;Lee, Young-Jun;Lee, Jung-Ryul
    • Smart Structures and Systems
    • /
    • v.26 no.5
    • /
    • pp.657-666
    • /
    • 2020
  • A rotational pulse-echo ultrasonic propagation imager that can inspect cylindrical specimens for material nondestructive evaluations is proposed herein. In this system, a laser-generated ultrasonic bulk wave is used for inspection, which enables a clear visualization of subsurface defects with a precise reproduction of the damage shape and size. The ultrasonic waves are generated by a Q-switched laser that impinges on the outer surface of the specimen walls. The generated waves travel through the walls and their echo is detected by a Laser Doppler Vibrometer (LDV) at the same point. To obtain the optimal Signal-to-Noise Ratio (SNR) of the measured signal, the LDV requires the sensed surface to be at a right angle to the laser beam and at a predefined constant standoff distance from the laser head. For flat specimens, these constraints can be easily satisfied by performing a raster scan using a dual-axis linear stage. However, this arrangement cannot be used for cylindrical specimens owing to their curved nature. To inspect the cylindrical specimens, a circular scan technology is newly proposed for pulse-echo laser ultrasound. A rotational stage is coupled with a single-axis linear stage to inspect the desired area of the specimen. This system arrangement ensures that the standoff distance and beam incidence angle are maintained while the cylindrical specimen is being inspected. This enables the inspection of a curved specimen while maintaining the optimal SNR. The measurement result is displayed in parallel with the on-going inspection. The inspection data used in scanning are mapped from rotational coordinates to linear coordinates for visualization and post-processing of results. A graphical user interface software is implemented in C++ using a QT framework and controls all the individual blocks of the system and implements the necessary image processing, scan calculations, data acquisition, signal processing and result visualization.

A Legal Study on the Standard for Conformity of the Goods in the International Sale of Goods (국제물품매매계약상(國際物品賣買契約上) 물품일치성(物品一致性)의 기준(基準)에 관한 법리적(法理的) 고찰(考察))

  • Song, Myeong-Bok
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.12
    • /
    • pp.133-162
    • /
    • 1999
  • The international sale transaction is in essence a sale of goods and presents all those commercial and legal problems in any sale of goods. As a result, A International sales contract imposes several duties on the parties : the seller must deliver the goods and transfer ownership in them, while the buyer must pay the price and take delivery of the goods. However, there are several problems which impede a active transaction between seller and buyer who have their places of business in other countries each other. Therefore, It is necessary to provide the concept on the conformity of goods in the Int'l Sale of Goods. Especially, In our consideration for the point of time when defects occurs, the existence of non-conformity of goods should be judged on the basis of time of delivery rather than time of contract. Moreover, The burden of proof about nonconformity of goods is another fact which make an international dispute between the contractual parties in an international trade. Thus, The consistency in the interpretation of law must be maintained betweened the warranty and seller's liability. In the Uniform Commercial Code and UN Convention, non-conformity of contract is made of contract liability. And in our civil and commercial law provisions of warranty should be understand as the special ones of the provisions of general non-performance of obligation liability. As a result, More concrete study of them is required because they may have a great influence especially on international trade. As a result, We should be our best in finding a helpful and systematic structure that the dualistic structure of nonperformance of obligation liability and warranty liability must be unified by studying the theories of English and American warranty and our legal system, as well as international practice and usage being used in an international trade.

  • PDF

A Revision Restoring Projection after Nipple Reconstruction by Burying Four Triangular Dermal Flaps

  • Kim, Ji Hun;Ahn, Hee Chang
    • Archives of Plastic Surgery
    • /
    • v.43 no.4
    • /
    • pp.339-343
    • /
    • 2016
  • Background Numerous techniques have been used to achieve long-term projection of the nipple following nipple-areola reconstruction. However, the reconstructed nipple loses projection over time. We describe a technique that uses local flaps to improve the lost projection of reconstructed nipples. Methods Between November 2013 and March 2015, nine patients (11 nipples) underwent revisional nipple reconstruction for lost projection. Only C-H nipple reconstructions were included in this study. The medical history of each patient was reviewed and photographs were taken in front and lateral views. All patients attended routine follow-up visits. Deepithelialized triangular flaps were made on all four sides of the nipple and buried in the opposite corners in order to augment the volume of the nipple. Anchoring sutures were used to attach each triangular flap on the side opposite their point of origin, and the resulting defects were closed directly. Results This procedure was used successfully in nine patients (11 nipples). Adequate projection was achieved in all patients and no complications occurred. The average nipple height was 3 mm before operation, 7 mm one day after operation, 5 mm at the six-month follow-up, and 5 mm at the 12-month follow-up. The average nipple-areolar angle was $164^{\circ}$ before the operation, $111^{\circ}$ one day after the operation, $130^{\circ}$ at the six-month follow-up, and $133^{\circ}$ at the 12-month follow-up. Conclusions The method described provides a solution to the loss of projection in reconstructed nipples. We recommend this technique because it leads to better projection, greater volume, and a more natural shape.

Reconstruction of the Soft Tissue Defect of the Lower Leg by Distally Based Superficial Sural Artery Fasciocutaneous Island Flap Using Supercharged Vein (원위기저 도서형 천비복동맥 근막피판으로 하지 재건 시 과급정맥문합의 이용)

  • Ha, Young In;Choi, Hwan Jun;Choi, Chang Yong;Kim, Yong Bae
    • Archives of Plastic Surgery
    • /
    • v.35 no.2
    • /
    • pp.208-213
    • /
    • 2008
  • Purpose: Distally based superficial sural artery island flap has some disadvantages such as postoperative flap edema, congestion, and partial necrosis of the flap margin. Venous congestion is an area of considerable concern in distally based superficial sural artery fasciocutaneous flap and is one of the main reasons for failure, particularly when a large flap is needed. However, we could decrease these disadvantages by means of venous superdrainage. Methods: From June of 2006 to June of 2007, a total of two patients with soft tissue defects of lower one third of the leg underwent venous supercharging distally based superficial sural artery island flap transfer. The distal pivot point of this flap was designed at septocutaneous perforator from the peroneal artery of the posterolateral septum, which was 5 cm above the tip of the lateral malleolus. Briefly, this technique is performed by anastomosing the proximal end of the lesser saphenous vein and collateral vein to any vein in the area of the recipient defect site. Results: No venous congestion was noted in any of the two cases. No other recipient or donor-site complications were observed, except for minor wound dehiscence in one case. In 3 to 6 months follow-up, patients had minor complaints about lack of sensation in the lateral dorsal foot. Conclusion: The peroneal artery perforator is predictable and reliable for the design of a distally based superficial sural artery island flap. Elevation of the venous supercharging flap is safe, easy, and less time consuming. In conclusion, the venous supercharging distally based superficial sural artery island flap offers an alterative to free tissue transfer for reconstruction of the lower extremity.

A Study on Precision Measurement of Rock Joint Using 3D-Laser Scanner (3D-Laser scanner를 이용한 암반 절리의 정밀측정에 관한 연구)

  • 이승호;황영철;김세현;심석래;정태영
    • Explosives and Blasting
    • /
    • v.22 no.3
    • /
    • pp.103-111
    • /
    • 2004
  • The existing methods that can be adopted for measuring joints involve either to use borehole or photogrammetry. Due to restricted space, acquisition of data in limited area, and measurement errors, above methods have limitations acquiring the objective and correct results. To get over defects of existing joint measurement methods, joints have been measured using 3D-Laser scanner with accuracy and efficiency. This research aims to investigate an accuracy and applicabiliy of 3D-Laser scanner for measuring rock slope joints. Measurement of rock slope joints has been executed using 3D-Laser scanner & clinometer and then, results from both methods are compared. Results from both methods indicate that they show nearly equal features for joint distributions and numbers of joint information obtained by 3D-Laser scanner are much more than ones measured using clinomer. Therefore, 3D-Laser scanner turns out to be very effective by the fact that it contributes to reduce investigation costs & periods, objectify data from rock slope joints.

Effects of Softwood Log Property and Veneer Defect on Veneer-and Plywood Manufacturing Yield (침엽수재(針葉樹材)의 원목형질(原木形質)과 단판결함(單板缺陷)이 단판(單板) 및 합판제조수율(合板製造收率)에 미치는 영향(影響))

  • Suh, Jin-Suk;Park, Jong-Young;Jo, Jae-Myeong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.40-47
    • /
    • 1988
  • Our plywood manufacturing industries which entertained prosperous stage in late 1970's have come to be in face of the problems of conceedingly obtaining good quality logs and yield up-grading, which is considered by future-replaceable forest resources. In view of this point, manufacturing characteristic on softwood plywood using Japanese larch, pitch pine as domestic plantation species, and western hemlock as foreign species was studied. In this study, veneer- and plywood manufacturing yields were discussed in relation to log properties and veneer defects (knots). The summarized conclusions were as follows: 1. The majority of sample logs belonged to second grade on the standard. And, eccentricity of larch was the highest 11%, about 2 times those of pitch pine, hemlock. 2. Knot frequency of occurrence of larch reached 19% within log height 8m, and pitch pine 13% within 4m. Correspondingly, the log height of larch available for plywood manufacture was higher by about 2 times that of pitch pine. 3. In the knot types, most of knots of larch appeared dead, whereas those of pitch pine and hemlock appeared live. In size of knots, larch and hemlock showed relatively small 1-2cm dia. by 70% or more and pitch pine did the larger 24cm by 65%. Generally the more knot emerged in the inner side of veneer than the outer. 4. Plywood manufacturing yields by peeling with spindle revolution lathe were 37% in larch > 32% in hemlock> 26% in pitch pine. S. Jointed core veneer yields by peeling with outer perimeter back-up lathe were 55% in hemlock> 53% in larch> and 48% in pitch pine.

  • PDF

Reconstruction of Fingertip Amputation by Using Digital Artery Perforator Flap (수부동맥 관통 피판을 이용한 손가락끝 절단의 재건)

  • Ha, Young In;Jung, Sung Gyun;Shin, Ho Seong;Park, Eun Soo;Park, Jang Woo;Choi, Hwan Jun
    • Archives of Plastic Surgery
    • /
    • v.35 no.4
    • /
    • pp.483-486
    • /
    • 2008
  • Purpose: Fingertip injuries are the most common hand injuries and may lead to significant disability. Knowledge of fingertip anatomy is mandatory to treat these injuries effectively. All surgical techniques used for coverage of fingertip injuries must be based on the nature of the injury and the patient's age. Many authors have studied the method of fingertip reconstruction because goals of these treatments should include maintaining length, sensibility, motions, and appearance. The purpose of this study is to evaluate the effect of digital artery perforator flap for fingertip reconstruction without aesthetic and functional problems. Methods: From November 2006 to March 2007, the authors performed fingertip reconstruction on 3 fingers of 3 patients, aged between 41 to 54 years (average age, 47 years) using digital artery perforator flap. Results: All fingers recovered successfully and there were no necrosis of the flap. We followed up 3 cases more than 5 months. Light touch and temperature sensation could be detected in all flaps and the static two-point discrimination test was 8 mm. Conclusion: This flap is an alternative choice for coverage of fingertip defects. This method also takes short time to procedure and to recovery. The digital artery perforator flap has never been reported in Korea, however it is considered as a useful method for treatment of fingertip injury.