• Title/Summary/Keyword: point defects

Search Result 497, Processing Time 0.024 seconds

PRELAMINATED FREE FLAP FOR THE RECONSTRUCTION OF MAXILLARY DEFECTS (전판상화 유리조직판을 이용한 상악결손 재건)

  • Kim, Ji-Youn;Pang, Kang-Mi;Park, Jong-Chul;Kim, Sung-Min;Myoung, Hoon;Kim, Myung-Jin;Lee, Jong-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.1
    • /
    • pp.13-20
    • /
    • 2009
  • Background In contrast to defects of the mandible and mouth floor region, in the defect of maxilla, the availability of firmly attached oral and nasal mucosal linings is needed. In addition to it, in consider of operation field, operating convenience, and esthetics, reconstruction using prelaminated flap is strongly recommended. Therefore we consider the prelaminated flap through the cases that is reconstructed using prelaminated forearm flap and prelaminated scapular flap. Patients and Methods From 2001 to 2008, in OMFS SNUDH, there were 6 cases that had reconstruction using prelaminated forearm free flap and other 3 cases that had reconstruction using prelaminated scapular flap of maxilla. The average age of patients that were reconstructed using prelaminated forearm free flap was 47.5 years, the average prelaminated period (after $1^{st}$ operation ${\sim}$ until $2^{nd}$ operation) was 51.8 days and the average follow-up period after $2^{nd}$ operation was 35.3 months. As well, the average age of patients that were reconstructed using prelaminated scapular free flap was 37 years, the average prelaminated period (after $1^{st}$ operation ${\sim}$ until $2^{nd}$ operation) was 57 days and the average follow-up period after $2^{nd}$ operation was 42.3 months. Results Except 1 case that were reconstructed using prelaminated scapular flap, we could get firmly attached oral and nasal stable skin(mucosal like) lining, more adequate thickness flap than any other flap and improved esthetic and functional results in the other 8 cases that were reconstructed using prelaminated flap. The complications of the prelaminated forearm flap cases were inconvenient swallowing, sputum, limitation of mouth opening and difficult mastication. It came from flap shrinkage of the flap in some aspect, as well as other combined operations such as mass resection or RND. The difficult point of the reconstruction of prelaminated scapular flap was the possibility of vascular damage at preparation of flap in $2^{nd}$ surgery. The damage could cause the failure of the prelaminated scapular flap. And the skin-lining of the prelaminated flap had limitations, so it is needed to study about the cultured oral epithelium-lining flap instead of the skin-lining flap. Conclusion We considered about advantages, complications and notable things of prelaminated flap through maxillary reconstruction cases using prelaminated forearm flap and prelaminated scapular flap so far. Furthermore, we should go on studying for functional reconstruction of prelaminated fasciomucosal flap using cultured oral epithelium.

Periodontal healing using a collagen matrix with periodontal ligament progenitor cells in a dehiscence defect model in beagle dogs

  • Yoo, Seung-Yoon;Lee, Jung-Seok;Cha, Jae-Kook;Kim, Seul-Ki;Kim, Chang-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.4
    • /
    • pp.215-227
    • /
    • 2019
  • Purpose: To histologically characterize periodontal healing at 8 weeks in surgically created dehiscence defects in beagle dogs that received a collagen matrix with periodontal ligament (PDL) progenitor cells. Methods: The bilateral maxillary premolars and first molars in 6 animals were used. Standardized experimental dehiscence defects were made on the buccal side of 3 premolars, and primary culturing of PDL progenitor cells was performed on the molars. Collagen matrix was used as a scaffold and a delivery system for PDL progenitor cells. The experimental sites were grafted with collagen matrix (COL), PDL progenitor cells with collagen matrix (COL/CELL), or left without any material (CTL). Histologic and histomorphometric analyses were performed after 8 weeks. Results: The defect height from the cementoenamel junction to the most apical point of cementum removal did not significantly differ across the CTL, COL, and COL/CELL groups, at $4.57{\pm}0.28$, $4.56{\pm}0.41$, and $4.64{\pm}0.27mm$ (mean ${\pm}$ standard deviation), respectively; the corresponding values for epithelial adhesion were $1.41{\pm}0.51$, $0.85{\pm}0.29$, and $0.30{\pm}0.41mm$ (P<0.05), the heights of new bone regeneration were $1.32{\pm}0.44$, $1.65{\pm}0.52$, and $1.93{\pm}0.61mm$ (P<0.05), and the cementum regeneration values were $1.15{\pm}0.42$, $1.81{\pm}0.46$, and $2.57{\pm}0.56mm$ (P<0.05). There was significantly more new bone formation in the COL/CELL group than in the CTL group, and new cementum length was also significantly higher in the COL/CELL group. However, there were no significant differences in the width of new cementum among the groups. Conclusions: PDL progenitor cells carried by a synthetic collagen matrix may enhance periodontal regeneration, including cementum and new bone formation.

The Effect of Thermal Annealing and Growth of CdIn2Te4 Single Crystal by Bridgeman Method (Bridgeman 법에 의한 CdIn2Te4단결정 성장과 열처리 효과)

  • Hong, K.J.;Lee, S.Y.;Moon, J.D.
    • Korean Journal of Materials Research
    • /
    • v.13 no.3
    • /
    • pp.195-199
    • /
    • 2003
  • The $p-CdIn_2$$Te_4$single crystal was grown in the three-stage vertical electric furnace by using Bridgman method. The quality of the grown crystal has been investigated by the x-ray diffraction and the photoluminescence measurements. From the photoluminescence spectra of the as-grown $CdIn_2$$Te_4$crystal and the various heat-treated crystals, the ($D^{\circ}$, X) emission was found to be the dominant intensity in the photoluminescence spectrum of the $CdIn_2$T $e_4$:Cd, while the ($A^{\circ}$, X) emission completely disappeared in the $CdIn_2$T $e_4$:Cd. However, the ($A^{\circ}$, X) emission in the photoluminescence spectrum of the $CdIn_2$T $e_4$:Te was the dominant intensity like an as-grown $CdIn_2$T $e_4$crystal. These results indicated that the ($D^{\circ}$, X) is associated with $V_{Te}$ acted as donor and that the ($A^{\circ}$, X) emission is related to $V_{cd}$ acted as acceptor, respectively. The $p-CdIn_2$T $e_4$crystal was found to be obviously converted into the n-type after annealing in the Cd atmosphere. The origin of ( $D^{\circ}$, $A^{\circ}$) emission and its TO phonon replicas is related to the interaction between donors such as $V_{Te}$ or $Cd_{int}$, and accepters such as $V_{cd}$ or T $e_{int}$. Also, the In in the $CdIn_2$X$CdIn_4$was confirmed not to form the native defects because it existed in the stable form of bonds.

Sliding Wear Properties of Carbon Fiber Reinforced $Si_3N_4$ Ceramics (탄소섬유강화 질화규소 세라믹스의 마찰마모 특성)

  • Park Yi-Hyun;Yoon Han-Ki;Kim Bu-Ahn;Park Won-Jo
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.347-351
    • /
    • 2004
  • [ $Si_3N_4$ ] composites have been extensively studied for engineering ceramics, because it has excellent room and high temperature strength, wear resistance properties, good resistance to oxidation, and good thermal and chemical stability. In the present work, carbon short fiber reinforced $Si_3N_4$ ceramics were fabricated by hot press method in $N_2$ atmosphere at $1800^{\circ}C$ using $Al_2O_3\;and\;Y_2O_3$ as sintering additives. Content of carbon short fiber was $0\%,\;0.1\%\;and\;0.3\%$. The composites were evaluated in terms of density, flexural strength and elastic modulus through the 3-point bending test at room temperature. Also, The wear behavior was determined by the pin on disk wear tester using silicon nitride ball. Experimental density and flexural strength decreased with increasing content of carbon fiber. But specific modulus increased with increasing content of carbon fiber. In addition, friction coefficient and specific wear loss decreased with increasing content of carbon short fiber by reason of interfacial defects between matrix and fiber.

  • PDF

Diatally-Based Medial Crural Adipofascial Flap for Coverage of Medial Foot and Ankle

  • Kim, Min Bom;Lee, Young Ho;Choi, Ho Sung;Kim, Dong Hwan;Lee, Jung Hyun;Baek, Goo Hyun
    • Archives of Reconstructive Microsurgery
    • /
    • v.24 no.2
    • /
    • pp.56-61
    • /
    • 2015
  • Purpose: We report on the clinical result after coverage of a soft tissue defect on the medial foot and ankle with an adipofascial flap based on the perforator from the posterior tibia artery. Materials and Methods: Nine patients with soft tissue defects on the medial foot and ankle area from March 2009 to May 2014 underwent the procedure. Average age was 54 years old (range, 8~82 years). There were five male patients and four female patients. The causes of the defect were trauma (4), tumor (3), and infection (2). The pivot point of transposition of this flap is the lower perforator originating from the posterior tibia artery. The fatty tissue side of this flap could be used to resurface the defect. The donor site was closed primarily with the preserved skin, and a small caliber drain tube was used. The split-thickness skin graft was grafted to the flap and the wound. If the wound was still infected, this skin graft could be performed at a later date. Results: All flaps survived and normal soft tissue coverage was obtained for the medial foot and ankle of all patients after the skin graft. Normal footwear was possible for all cases because of thin coverage. There was an extension contracture on the medial ray of the foot, which was resolved by contracture release and skin graft. Conclusion: For the medial foot and ankle soft tissue defect, the medial crural adipofascial flap based on a perforator branch of the posterior tibia artery could be a good option to cover it.

Detection of furcation involvement using periapical radiography and 2 cone-beam computed tomography imaging protocols with and without a metallic post: An animal study

  • Salineiro, Fernanda Cristina Sales;Gialain, Ivan Onone;Kobayashi-Velasco, Solange;Pannuti, Claudio Mendes;Cavalcanti, Marcelo Gusmao Paraiso
    • Imaging Science in Dentistry
    • /
    • v.47 no.1
    • /
    • pp.17-24
    • /
    • 2017
  • Purpose: The purpose of this study was to assess the accuracy, sensitivity, and specificity of the diagnosis of incipient furcation involvement with periapical radiography (PR) and 2 cone-beam computed tomography (CBCT) imaging protocols, and to test metal artifact interference. Materials and Methods: Mandibular second molars in 10 macerated pig mandibles were divided into those that showed no furcation involvement and those with lesions in the furcation area. Exams using PR and 2 different CBCT imaging protocols were performed with and without a metallic post. Each image was analyzed twice by 2 observers who rated the absence or presence of furcation involvement according to a 5-point scale. Receiver operating characteristic (ROC) curves were used to evaluate the accuracy, sensitivity, and specificity of the observations. Results: The accuracy of the CBCT imaging protocols ranged from 67.5% to 82.5% in the images obtained with a metallic post and from 72.5% to 80% in those without a metallic post. The accuracy of PR ranged from 37.5% to 55% in the images with a metallic post and from 42.5% to 62.5% in those without a metallic post. The area under the ROC curve values for the CBCT imaging protocols ranged from 0.813 to 0.802, and for PR ranged from 0.503 to 0.448. Conclusion: Both CBCT imaging protocols showed higher accuracy, sensitivity, and specificity than PR in the detection of incipient furcation involvement. Based on these results, CBCT may be considered a reliable tool for detecting incipient furcation involvement following a clinical periodontal exam, even in the presence of a metallic post.

Reconstruction for the Soft Tissue Defect of Heel using Free Lateral Arm Neurosensory Flap (유리 외측 상박 감각신경 피판술을 이용한 종부 연부조직 결손의 재건)

  • Kim, Dong-Churl;Kim, Sang-Soo;Ha, Dae-Ho;Yoo, Hee-Jun;Lee, Dong-Hoon
    • Archives of Reconstructive Microsurgery
    • /
    • v.8 no.1
    • /
    • pp.15-21
    • /
    • 1999
  • Soft tissue defect on heel area of the foot present difficult problems particularly because of anatomic property of plantar surface of the foot. There is a paucity of available local tissue in the foot for coverage. In addition to having little expandable tissue, the foot's plantar surface has a unique structure, making its replacement especially challenging. Plantar skin is attached to the underlying bone by fibrous septa, preventing shear of the soft-tissue surfaces from the underlying skeleton. Plantar surface of foot is in constant contact with the environment. Protective sensibility also would be maintained or restored in the ideal reconstruction. So the ideal flap for reconstruction of the heel should include thin, durable hairless skin with potential for reinnervation. The aim of this article is to present a clinical experience of free lateral arm neurosensory flap for reconstruction of the heel. From March 1995 to December 1997, a total 16 lateral arm free flaps were performed to soft tissue defects on the weight-bearing area of the hindfoot. we used tibial nerve as recepient nerve in 11 and calcaneal branch of tibial nerve in 5 for restoration of sensibility of flap. All cases survived completely. A static two-point discrimination of 14 to 34mm was detected in the flap. Radial nerve palsy which was caused by hematoma in donor site occured in one case, but recorverd in 3 weeks later completely. In conclusion, the lateral arm free flaps are versatile, reliable and sensible cutaneous flap and especially indicated for soft tissue defect on plantar surface of the hindfoot which are not good indications for other better-known flaps.

  • PDF

Investigation of Micromorphological Characteristics of Acupuncture Needle Tip Sold in Europe (유럽에서 유통되는 일회용침 끝의 미세 형태에 대한 관찰)

  • Jang, In-Soo;Lee, Tae-Ho;Lee, Chang-Hyun;Park, Jong-Bae
    • Korean Journal of Acupuncture
    • /
    • v.21 no.4
    • /
    • pp.43-51
    • /
    • 2004
  • Objectives : In order to ensure safe acupuncture treatment, the quality of the needle tip is essential. But, there have not been so many studies about the quality of the acupuncture needle tip. For this reason we have been already reported about the quality of acupuncture needle tip in Korea using scanning electron microscope(SEM) in 2002, 2003. In order to compare than other society, we investigated the current condition of the tips of the acupuncture needles sold in Europe. Methods : We obtained the needles made by 7 companies, which are sold currently in Europe, and selected 50 pieces out of 100 pieces from each company by randomized methods. And then we observed the tip of each needle using a scanning electron microscope at ${\times}800$ magnification. Results and Discussion : We found that needles had several defects such as scratch marks on the surface, metallic scuff, lumps and irregularities of the needle tips, stubbed or malformed tips, tips of point off-center, peeled off coated tips, same as Korean needles. There was much difference on the quality of needles among the manufacturers, and some needles seem to need thorough quality control. Allowing for the high price, the quality of some needle in Europe generally are better than that of Korean needles. But some Korean needles hold a top position than European ones in quality. We want a good industrial standard to be made in acupuncture manufacturing fields in the near future, because the safety is not less valuable than the efficacy in medicine.

  • PDF

A Basic Study on the Crack Arrest Phenomena (균열정지현상에 관한 기초적 연구)

  • 이억섭;김상철;송정일
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.1
    • /
    • pp.112-118
    • /
    • 1990
  • Catastrophic fracture cannot be avoided after cracks(initiated from pre-existing defects) propagate rapidly with speeds comparable to a sound wave velocity of the materials. Preventing catastropic failure, crack arrest fracture toughness defined from dynamic(or kinetic) fracture mechanics point of view has been introduced in determining accurate and/or proper crack arrest fracture toughness of a material. For the past decades, many studies have been carried out to render proper theoretical and experimental backgrounds on the use of the static plain strain crack arrest fracture toughness, $K_{1a}$ (which seems to be a material property). $K_{1a}$ has been used to predict the performance of thick walled structures and has been considered as a measure of the ability of a material to stop a fast running crack. Determination of such a material property is of prime importance to the nuclear reactor pressure vessel and bridge materials industries. However, standards procedures for measuring toughness associated with fast running cracks are yet to exist. This study intends to give insight on the determination of the crack arrest fracture toughness of materials such as polymethylmethacrylate(PMMA), SM45C-steel, and A1 7075-T6. The effects of crack jump lengths and fast crack initiation stress intensity factor on the determination of $K_{1a}$ have been experimentally observed.erved.

Medical Application of the Nondestructive Ultrasonic Tests: Diagnosis of Micro Bone Fractures using Ultrasonic C Scan Images (비파괴 초음파 검사법의 의학적 활용: 초음파 C 스캔 영상을 이용한 미세 골절의 진단)

  • Choi, Min-Joo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.4
    • /
    • pp.377-385
    • /
    • 2002
  • Ultrasonic tests employing non-ionizing radiation are preferred in nondestructive examinations since they are safe and simple in use. The same principles of the techniques have been taken as valuable tools in medical area for the diagnoses of diseases, in other words, defects of the human body. The paper overviews the principles of the medical diagnosis based on nondestructive ultrasonic tests, and then evaluates experimentally the clinical potential of C scan images not popular in medicine, for detecting the micro fractures of the cortical bone. In the experiment the micro bone fractures were created on the femurs of porks by loading three point bending forces (2-4kN) with the speed of 1 mm/min. As the extent of the fracture was altered, not only X ray images but also ultrasonic C scan images using a focused ultrasonic probe resonated at 25 MHz were obtained. The results showed that ultrasonic C scan images were capable of detecting the micro bone fractures which were not possible to identify by conventional X ray images.