New technique for strengthening reinforced concrete beams with composite bonding steel plates

  • Yang, Su-hang;Cao, Shuang-yin;Gu, Rui-nan
    • Steel and Composite Structures
    • /
    • 제19권3호
    • /
    • pp.735-757
    • /
    • 2015
  • Composite bonding steel plate (CBSP) is a newly developed type of structure strengthened technique applicable to the existing RC beam. This composite structure is applicable to strengthening the existing beam bearing high load. The strengthened beam consists of two layers of epoxy bonding prestressed steel plates and the RC beam sandwiched in between. The bonding enclosed and prestressed U-shaped steel jackets are applied at the beam sides. This technique is adopted in case of structures with high longitudinal reinforcing bar ratio and impracticable unloading. The prestress can be generated on the strengthening steel plates and jackets by using the CBSP technique before loading. The test results of full-scale CBSP strengthened beams show that the strength and stiffness are enhanced without reduction of their ductility. It is demonstrated that the strain hysteresis effect can be effectively overcome after prestressing on the steel plates by using such technique. The applied plates and jackets can jointly behave together with the existing beam under the action of epoxy bonding and the mechanical anchorage of the steel jackets. The simplified formulas are proposed to calculate the prestress and the ultimate capacities of strengthened beams. The accuracy of formulas was verified with the experimental results.

대공간 교육시설 축조를 위한 프리스트레스트 보에 사용되는 접합 강재의 성능평가에 대한 연구 (A Study for Structural Capacity Evaluation of Embedded Steel Plate Connected with Prestressed Concrete Beam to Build Large Space Educational Facilities)

  • 이경훈
    • 교육녹색환경연구
    • /
    • 제10권2호
    • /
    • pp.1-7
    • /
    • 2011
  • An experimental study to evaluate structural capacity of an embedded plate connected with prestressed concrete beam was performed. Embedded steel plates and prestressed concrete beam were connected with stud-bolts at the ends of concrete beam specimens. About 1,000 kN concentrated load was applied at 450mm away from the end of beam specimen. A 3,000 kN capacity static Oil-jack was used to direct concentrated load. The maximum strain of stud-bolt recorded $90{\times}10^{-6}$(mm/mm) and wide width cracks were not founded. Any falling failures of concrete and large deformations were not founded either between steel plate and prestressed concrete specimen. As a result, construction performance can be improved using this embedded steel plate connection system apply to large space educational facilities.

CFRP 보강공법에 따른 RC보의 휨성능 개선효과 (Development of Flexural Capacity of RC Beam by CFRP Strengthening Methods)

  • 홍기남;한상훈;김형수;우상균;송영철;김형진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.133-136
    • /
    • 2005
  • Experimental research was conducted to investigate the characteristic of various CFRP strengthening methods. A total of 4 specimens of 3.3m length were tested in four point bending after strengthening them with externally bonded CFRP plates. The CFRP plates were bonded without prestress or with prestress levels of CFRP plate strain $0.5\%$. The non-prestressed specimen without anchor plate failed by separation of the plate from the beam due to premature debonding while the non-prestressed specimen with anchor plate failed by CFRP fracture and showed the significant increase of ductility capacity. In addition, the prestressed specimens failed by concrete compression failure. The maximum load and ductility capacity were most significantly increased.

  • PDF

프리스트레스를 가한 CFRP판으로 보강한 철근콘크리트 보의 휨성능 개선 (Improvement in Flexure Capacities of Reinforced Concrete Beams Strengthened with Prestressed CFRP Plates)

  • 김형수;홍기남;우상균;송영철;한상훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.471-474
    • /
    • 2005
  • This thesis presents the results of a study on improvement in flexure capacities of reinforced concrete beams strengthened with prestressed CFRP plates. Test variables included the type of strengthening, steel ratio and prestressing level. The experimental results show that proposed methods can increase the flexure capacity such as strength, stiffness of the beam remarkably.

  • PDF

긴장된 CFRP판으로 보강된 대규모 RC 슬래브의 휨성능 평가 (Evaluation of Flexural Strength Capacity of Large Scale RC Slabs Strengthened with Prestressed CFRP Plate)

  • 홍기남;한상훈;이병노;권용길
    • 한국안전학회지
    • /
    • 제25권3호
    • /
    • pp.71-77
    • /
    • 2010
  • This paper presents the results of a study on flexural capacity of large size RC slabs strengthened with carbon fiber reinforced polymer(CFRP) plates. A total of 5 specimens of 6.0m length were tested in four point bending after strengthening them with externally bonded CFRP plates. The CFRP plates were bonded without prestress and with two prestress levels, 0.4% and 0.6% of CFRP plate strain. Test variables included the type of strengthening, prestressing level, and the effects according to each test variables are analysed. The experimental results show that proposed methods can increase significantly the flexural capacity such as strength, stiffness of the beam and the increase ranged between 36.2% and 63.2% of the load-carrying capacity of the control beams. The non-prestressed specimen failed by separation of the plate from the beam due to premature debonding while most of the prestressed specimens failed by CFRP plate fracture. And the cracking loads and maximum loads were increased proportionally to the prestress level.

비부착 프리스트레스트 CFRP 판으로 보강된 콘크리트 거더의 비선형 해석 (Nonlinear Analysis of Concrete Girders Strengthened with Unboded Prestressed CFRP Plates)

  • 최규천;이재석
    • 대한토목학회논문집
    • /
    • 제30권6A호
    • /
    • pp.495-502
    • /
    • 2010
  • 이 논문에서는 비부착 프리스트레스트 CFRP 판으로 보강된 콘크리트 거더의 비선형 휨거동에 대한 해석방법을 제시하였다. 비부착 프리스트레스트 CFRP 판으로 보강된 콘크리트 거더는 CFRP 판의 슬립(slip)으로 인해 인장력이 재분배되어 CFRP 판이 콘크리트에 부착된 경우에 비해 복잡한 비선형 거동을 보이게 된다. 따라서 이 논문에서는 비부착 프리스트레스트 CFRP 판을 여러 개의 곡선 요소로 모사하고, 화이버 뼈대요소의 각 절점에서 힘의 평형 관계를 이용하여 CFRP 판의 인장력을 재분배함으로써 슬립효과를 고려하였다. 이 논문에서 제시한 해석방법을 비부착 프리스트레스트 CFRP 판으로 보강된 콘크리트 보의 해석에 적용하여 해석방법의 정당성을 확인하였다. 또한 비부착 CFRP 판의 보강시점과 보강 전후에 발생한 콘크리트의 시간의존적 변형은 보의 처짐 거동에는 영향을 미치나 극한내력에는 영향을 미치지 않음을 확인하였고, 비부착 CFRP 판으로 보강하기 전에 발생한 콘크리트의 균열유무도 비부착 CFRP 판으로 보강한 후의 보의 극한거동에는 거의 영향을 미치지 않음을 확인하였다.

Strengthening of steel-concrete composite beams with prestressed CFRP plates using an innovative anchorage system

  • Wan, Shi-cheng;Huang, Qiao;Guan, Jian
    • Steel and Composite Structures
    • /
    • 제32권1호
    • /
    • pp.21-35
    • /
    • 2019
  • This study investigates the flexural behavior of steel-concrete composite beams strengthened with prestressed carbon fiber-reinforced polymer (CFRP) plates. An innovative mechanical anchorage system was developed. The components of the system can be easily assembled on site before applying a prestressing force, and removed from the structures after strengthening is completed. A total of seven steel-concrete composite specimens including four simply supported beams strengthened at the positive moment region and three continuous beams strengthened at the negative moment region were tested statically until failure. Experimental results showed that the use of prestressed CFRP plates enhanced the flexural capacity and reduced the mid-span deflection of the beams. Furthermore, by prestressing the CFRP laminates, the material was used more efficiently, and the crack resistance of the continuous composite specimens at the central support was significantly improved after strengthening. Overall, the anchorage system proved to be practical and feasible for the strengthening of steel-concrete composite beams. The theoretical analysis of ultimate bearing capacity is reported, and good agreement between analytical values and experimental results is achieved.

Analysis of mechanical performance of continuous steel beams with variable section bonded by a prestressed composite plate

  • Tahar Hassaine Daouadji;Rabahi Abderezak;Benferhat Rabia
    • Steel and Composite Structures
    • /
    • 제50권2호
    • /
    • pp.183-199
    • /
    • 2024
  • In this paper, a closed-form rigorous solution for interfacial stress in continuous steel beam with variable section strengthened with bonded prestressed FRP plates and subjected to a uniformly distributed load is developed using linear elastic theory and including the variation of fiber volume fractions with a longitudinal orientation of the fibers of the FRP plates. The results show that there exists a high concentration of both shear and normal stress at the ends of the laminate, which might result in premature failure of the strengthening scheme at these locations. The theoretical predictions are compared with other existing solutions. Overall, the predictions of the different solutions agree closely with each other. A parametric study has been conducted to investigate the sensitivity of interface behavior to parameters such as laminate and adhesive stiffness, the thickness of the laminate and the fiber volume fractions where all were found to have a marked effect on the magnitude of maximum shear and normal stress in the composite member. This research gives a numerical precision in relating to the others studies which neglect the effect of prestressed plate and the shear lag impact. The physical and geometric properties of materials are taken into account, and that may play an important role in reducing the interfacial stresses magnitude.

Performance of damaged RC continuous beams strengthened by prestressed laminates plate: Impact of mechanical and thermal properties on interfacial stresses

  • Tahar, Hassaine Daouadji;Abderezak, Rabahi;Rabia, Benferhat;Tounsi, Abdelouahed
    • Coupled systems mechanics
    • /
    • 제10권2호
    • /
    • pp.161-184
    • /
    • 2021
  • Strengthening of reinforced concrete beams with externally bonded fiber reinforced polymer plates/sheets technique has become widespread in the last two decades. Although a great deal of research has been conducted on simply supported RC beams, a few studies have been carried out on continuous beams strengthened with FRP composites. This paper presents a simple uniaxial nonlinear analytical model that is able to accurately estimate the load carrying capacity and the behaviour of damaged RC continuous beams flexural strengthened with externally bonded prestressed composite plates on both of the upper and lower fibers, taking into account the thermal load. The model is based on equilibrium and deformations compatibility requirements in and all parts of the strengthened beam, i.e., the damaged concrete beam, the FRP plate and the adhesive layer. The flexural analysis results and analytical predictions for the prestressed composite strengthened damaged RC continuous beams were compared and showed very good agreement in terms of the debonding load, yield load, and ultimate load. The use of composite materials increased the ultimate load capacity compared with the non strengthened beams. The major objective of the current model is to help engineers' model FRP strengthened RC continuous beams in a simple manner. Finally, this research is helpful for the understanding on mechanical behaviour of the interface and design of the FRP-damaged RC hybrid structures.

Stress intensity factors for double-edged cracked steel beams strengthened with CFRP plates

  • Wang, Hai-Tao;Wu, Gang;Pan, Yu-Yang;Zakari, Habeeb M.
    • Steel and Composite Structures
    • /
    • 제33권5호
    • /
    • pp.629-640
    • /
    • 2019
  • This paper presents a theoretical and finite element (FE) study on the stress intensity factors of double-edged cracked steel beams strengthened with carbon fiber reinforced polymer (CFRP) plates. By simplifying the tension flange of the steel beam using a steel plate in tension, the solutions obtained for the stress intensity factors of the double-edged cracked steel plate strengthened with CFRP plates were used to evaluate those of the steel beam specimens. The correction factor α1 was modified based on the transformed section method, and an additional correction factor φ was introduced into the expressions. Three-dimensional FE modeling was conducted to calculate the stress intensity factors. Numerous combinations of the specimen geometry, crack length, CFRP thickness and Young's modulus, adhesive thickness and shear modulus were analyzed. The numerical results were used to investigate the variations in the stress intensity factor and the additional correction factor φ. The proposed expressions are a function of applied stress, crack length, the ratio between the crack length and half the width of the tension flange, the stiffness ratio between the CFRP plate and tension flange, adhesive shear modulus and thickness. Finally, the proposed expressions were verified by comparing the theoretical and numerical results.