• 제목/요약/키워드: plate

검색결과 18,526건 처리시간 0.036초

Elastic bending analysis of irregular-shaped plates

  • Sakiyama, T.;Huang, M.
    • Structural Engineering and Mechanics
    • /
    • 제7권3호
    • /
    • pp.289-302
    • /
    • 1999
  • An approximate method for analyzing the bending problems of irregular-shaped plates is proposed. In this paper irregular-shaped plates are such plates as plate with opening, circular plate, semi-circular plate, elliptic plate, triangular plate, skew plate, rhombic plate, trapezoidal plate or the other polygonal plates which are not uniform rectangular plates. It is shown that these irregular-shaped plates can be considered finally as a kind of rectangular plates with non-uniform thickness. An opening in a plate can be considered as an extremely thin part of the plate, and a non-rectangular plate can be translated into a circumscribed rectangular plate whose additional parts are extremely thin or thick according to the boundary conditions of the original plate. Therefore any irregular-shaped plate can be replaced by the equivalent rectangular plate with non-uniform thickness. For various types of irregular-shaped plates the convergency and accuracy of numerical solution by proposed method are investigated.

Numerical Analysis of Vertical Plate Absorber for Optimal Design

  • Yoon, Jung-In;Moon, Choon-Geun;Phan, Thanh-Tong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권2호
    • /
    • pp.252-262
    • /
    • 2004
  • A model of simultaneous heat and mass transfer process in absorption of refrigerant vapor into a lithium bromide solution of water-cooled vertical plate absorber. which was considered to the change of refrigerant vapor pressure along the plate width direction. was developed to evaluate the compactness of plate absorber and supply basis data for optimal design of plate absorber. The effects of plate interval as well as the effect of capacity for one piece of plate absorber on plate absorber size such as plate height. plate heating area and plate absorber volume have been investigated. It is confirmed that there is exist an optimal plate interval minimizing plate absorber volume. And the smaller capacity for one piece of plate absorber. the smaller plate absorber volume is obtained.

목재 트러스 접합부의 toothed metal plate 접합과 plywood gusset plate 접합에 관한 연구 (Study on Metal Plate Connections and Plywood Gusset Plate Connections for Light-Frame Wood Truss Tension Joint)

  • 차재경
    • Journal of the Korean Wood Science and Technology
    • /
    • 제20권1호
    • /
    • pp.46-50
    • /
    • 1992
  • 본 연구는 잣나무 간벌재를 이용한 plywood gusset plate 접합과 toothed metal plate 접합에 대하여 인장력을 가해 조사하였다. plywood gusset plate 접합에 있어서는 합판과 부재 사이를 상온 경화제(초산 비닐 수지)로 접착한 후 6d 못으로 접합한 형태와 단지 합판만을 사용한 형태의 plywood gusset plate 접합 사이의 기계적 특성 차이를 조사했다. toothed metal plate 접합은 plywood gusset plate 접합보다 인장력에서 좋은 behavior를 보였다. 또한 접착제를 가한 plywood gusset plate 접합은 접합제를 가하지 않은 형태보다 큰 하중 지지력을 보였다.

  • PDF

과채류 재배에 사용되는 잔류성 농약의 돌연변이 유발성에 관한 연구 (Mutagenicity of residual pesticides using to cultivate the fruits and vegetables in the Salmonella typhimurium)

  • 고용구
    • 환경위생공학
    • /
    • 제3권1호
    • /
    • pp.41-67
    • /
    • 1988
  • Salmonella typhimurium을 이용하는 Ames방법 (1973)에 따라 과채류 재배에 많이 사용되는 12종의 농약에 대하여 돌연변리 유발성을 검정한 결과를 요약하면 다음과 같다. 1) 잔류성 농약 12종에 대한 돌연변이유발성은 Dicofol을 제외한 11종의 농약에서 나타났다. 특히 쥐간 혼합추출물(S-9 mixture)로 活性化시쳤을 때 강한 돌연변이 유발성을 보였다. 2) 돌연변이 유발성은 다음과 같이 분류할 수 있었다. (1) 본 실험의 시료인 12종의 농약의 돌연변이유발성은 Salmonella typhimuriumTA 100에서 EPN과 Dicofol을 제외한 10종의 농약에서 감응성을 나타내였으며 특히 S-9 mixture로 활성화 시켰을 경우에는 강한 감응성을 보였다. 각 농약의 가장 높은 감응성을 나타낸 농약별 농도를 보면, Thalonil은 $0.2{\mu}g/plate(710),\;Monopho$$0.05{\mu}g/plate(1,260),\;Tedion$$1.0{\mu}l/plate(9,900),\;Danoton$$1.0{\mu}l/plate(4,910),\;Ometon$$0.10{\mu}l/plate(4,980),\;prosing$$0.20{\mu}g/plate(283),\;Phentoate$$1.0{\mu}g/plate(494),\;Parathion$$0.05{\mu}l/plate(145),\;Sappiran$$0.05{\mu}g/plate(295)$ 및 Captan은 $1.0{\mu}g/plate(2,700)$이었다. (2) Salmonella typhimurium TA98에서는 Dicofol과 Captan을 제외한 10종의 농약에서 반응성을 보였다. 각 농약의 가장 높은 감응성을 나타낸 농약별 농도를 보면, Thalonil은 $0.05{\mu}g/plate(1,237),\;Monopho$$1.0{\mu}g/plate(1,737),\;Tedion$$1.0{\mu}l/plate(4,937),\;Danoton$$0.5{\mu}l/plate(2,000),\;Ometon$$0.10{\mu}l/plate(112),\;prosing$$0.50{\mu}g/plate(670),\;EPN$$0.05{\mu}l/plate(440),\;phentoate$$0.01{\mu}g/plate(540),\;parathion$$0.05{\mu}g/plate(910)$ 및 Sappiran은 $0.02{\mu}g/plate(1,210)$이었다. (3) Salmonella typhimurium TA1535 TA1538에서는 TA100과 TA98에 비하여 대체적으로 낮은 감응성을 나타내었는데, TA1535에서는 Canoton이 $0.02{\mu}l/plate(148),\;Tedion$$1.0{\mu}l/plate(295)$ 및 Captan이 $1.0{\mu}g/plate(170)$이었고, TA 1538에서는 Thalonil $0.2{\mu}g/plate(1,233),\;Monopho$$0.1{\mu}g/plate(1,783),\;Tedion$$1.0{\mu}l/plate(483),\;EPN$$1.0{\mu}l/plate(180),\;phentoate$$0.05{\mu}g/plate(142)$이었다. 3) Salmonella typhimurium TA100과 TA98에서 공통적으로 높은 감응성을 보이는 농약은 Thalonil, Monopho, Tedion, Danoton, Prosing, Phentoate, Parathion 및 Sappiran이었다. Ometon은 TA100, EPN은 TA98에서만 활성을 보였다. 4) Dicofol을 제외한 11종의 농약이 과피를 식용하는 과실류 및 채소류에 사용하는 것은 식품위생상 문제가 있다고 판단되며 앞으로 이에 대하여는 더욱 연구검토되어야 한다고 생각된다.

  • PDF

Topology optimization of steel plate shear walls in the moment frames

  • Bagherinejad, Mohammad Hadi;Haghollahi, Abbas
    • Steel and Composite Structures
    • /
    • 제29권6호
    • /
    • pp.771-783
    • /
    • 2018
  • In this paper, topology optimization (TO) is applied to find a new configuration for the perforated steel plate shear wall (PSPSW) based on the maximization of reaction forces as the objective function. An infill steel plate is introduced based on an experimental model for TO. The TO is conducted using the sensitivity analysis, the method of moving asymptotes and SIMP method. TO is done using a nonlinear analysis (geometry and material) considering the buckling. The final area of the optimized plate is equal to 50% of the infill plate. Three plate thicknesses and three length-to-height ratios are defined and their effects are investigated in the TO. It indicates the plate thickness has no significant impact on the optimization results. The nonlinear behavior of optimized plates under cyclic loading is studied and the strength, energy and fracture tendency of them are investigated. Also, four steel plates including infill plate, a plate with a central circle and two types of the multi-circle plate are introduced with equal plate volume for comparing with the results of the optimized plate.

바이올린 플레이트의 도장처리(塗裝處理)가 흡습성(吸濕性)과 진동모드에 미치는 영향(影響) (Effects of Finishing of Violin Plate on Its Adsorption and Vibration Modes)

  • 권주용;정희석
    • Journal of the Korean Wood Science and Technology
    • /
    • 제26권3호
    • /
    • pp.16-25
    • /
    • 1998
  • This study was carried out to compare vibrational properties and adsorption among shellac, cashew finished plate and untreated plate of Sitka spruce(Picea sitchensis Carr). By the method of statistical regression modeling, the fundamental resonance frequency of finished plate was higher than that of untreated plate. The fundamental resonance frequency of cashew finished plate was higher than that of shellac finished plate. By the method of modal analysis, mode frequency ratio of cashew finished plate was higher than that of shellac finished plate. Amounts of adsorption of finished plate was lower than that of untreated plate, and amount of adsorption of cashew finished plate was lower than that of shellac finished plate. It was clarified that the vibrational properties and adsorption of finished plate were superior to those of untreated plate. The vibrational properties and adsorption of cashew finished plate was superior to those of shellac finished plate.

  • PDF

양축 면내 압축하중 하의 이중판보강 선박판부재의 설계시스템 구축 (Development of Ship Plate Member Design System Reinforced by Doubler Plate Subjected to Biaxial In-plane Compressive Load)

  • 함주혁
    • 한국해양공학회지
    • /
    • 제30권4호
    • /
    • pp.294-302
    • /
    • 2016
  • Because of the importance of steel material saving and rational ship structural design due to the rapid increase in steel prices, a ship structural design system was developed for plate members reinforced by doubler plates subjected to biaxial in-plane compressive loads. This paper mainly emphasizes the design system improvement and upgrade according to the change in the in-plane loading condition of the doubler plate from the single load discussed in a previous paper to the biaxial in-plane compressive load discussed in this paper. A direct design process by a structural designer was added to this developed optimized system to increase the design efficiency and provide a way of directly inserting a designer's decisions into the design system process. As the second stage of preliminary steps of doubler design system development, design formulas subjected to these biaxial loads used in the doubler plate design system were suggested. Based on the introduction of influence coefficients $K_t_c$, $K_t_d$, $K_b_d$ and $K_a_d$ based on the variations in the doubler length, breadth, doubler thickness, and average corrosion thickness of the main plate reinforced by the doubler plate, respectively, the design formulas for the equivalent plate thickness of the main plate reinforced by the doubler plate were also developed, and a hybrid design system using these formulas was suggested for the doubler plate of a ship structure subjected to a biaxial in-plane compressive load. Using this developed design system for a main plate reinforced by a doubler plate was expected to result in a more rational reinforced doubler plate design considering the efficient reinforcement of ship plate members subjected to these biaxial loads. Additionally, a more detail structural analysis through local strength evaluations will be performed to verify the efficiency of the optimum structural design for a plate member reinforced by a doubler plate.

Plate/Plate, Truncated Cone/Plate 센서를 이용한 시멘트반죽 유변학적 특성에 대한 개선된 측정 (Improved Measurements of the Rheological Property of Cement Paste using Plate/Plate and Truncated cone/Plate Sensors)

  • 민병현
    • 유변학
    • /
    • 제7권1호
    • /
    • pp.10-18
    • /
    • 1995
  • Plate/plate 및 Truncated cone/plate 감지부를 이용한 시멘트반죽의 유변학적 특성 을 측정함에 있어 관련된 오차에 대한 실험 및 이론적 분석이 보고된다. 주요인자로는 감지 부 직경과 상하 감지부 사이의 간격이 고려되었다. Cone/plate 감지부의 원추끝을 깍아 간 격의 크기를 늘린 Truncated cone/plate 감지부의 토르크 분포에 대한 이론적 분석결과 원 추 간격이 0.7mm 까지 절단되더라도 8.5%의 오차범위내에서는 cone/plate 감지부의 역할을 수행하는 것으로 판단된다. 실험결과는 샘플주변의 상대습도가 결과에 영향을 끼치고 감지 부의 기하학적 요인에도 매우 민감함을 보여준다. 이결과는 정지시간을 포함한 오랜실험기 간동안 미소변형하에서 유변학적 특성을 연구하는데 도움이 될것으로 판단된다.

  • PDF

정수장침전지 경사판의 저류판부착에 관한 연구 (A Study on the stick fin of Water inclination plate settler)

  • 양원영;탁성제;김성순
    • 상하수도학회지
    • /
    • 제12권4호
    • /
    • pp.106-111
    • /
    • 1998
  • In this paper,to know sedimentation efficiency compared with sedimentation efficiency's experiment result by general and inclination plate settler, its and fin stick of inclination plate. Experiment result is inclination plate settler increase sedimentation efficiency's 6.96% than general settler, When fin stick of inclination plate is the optimum condition of one side, inclination plate's angle $60^{\circ}$, fin's width 67mm, fin's interval 200mm, sedimentation efficiency of many experimental condition increase 6.63% than inclination plate settler. A studdy on the site plottage through the result, Water inclination plate settler of the present's application reduce 30% of its than general settler. According to the above statements, fin stick of inclination plate's sedimentation efficiency is 0.95 times of inclination plate settler's. Concluding remarks, Fin stick of inclination plate reduce 28.5% of its than inclination plate settler.

  • PDF

Clinical and Radiologic Results Comparing the Periarticular Proximal Humerus Locking Plate and Polarus Nail for Displaced Proximal Humerus Fractures

  • Min, Young-Kyoung;Lee, Seung-Jun;Gwak, Heui-Chul;Kang, Sang-Woo;Suh, Kuen-Tak
    • Clinics in Shoulder and Elbow
    • /
    • 제20권4호
    • /
    • pp.208-216
    • /
    • 2017
  • Background: This study compared the clinical and radiological outcomes of the single calcar screw plate and Polarus nail techniques for the treatment of the proximal humerus fractures. Methods: Seventy-two patients diagnosed with displaced proximal humerus fracture were enrolled for the study. Of these, 50 patients underwent the locking plate surgery with a single calcar screw (plate group), whereas 22 patients underwent the Polarus nail surgery (nail group). The plate group was further divided into plate 1 group (with medial support), and plate 2 group (without medial support). The radiological and functional results of both groups were compared to the nail group. Results: The ${\alpha}$ angle 1 year after surgery was significantly different between plate 1 and plate 2, and plate 2 and nail groups (p=0.041, p=0.043, respectively). The ratio that does not satisfy the reference value of ${\gamma}$ angle was 2.8% in plate 1, 7.1% in plate 2 and 22.7% in nail group (p=0.007); there was a significant difference between plate 1 and nail group, and plate 2 and nail group (p=0.014, p=0.033, respectively). Conclusions: No significant differences were observed in the clinical results between locking plate and Polarus nail. However, in the plate 2 group and nail group, the rate of failure to maintain reduction during the 1-year period after surgery was statistically and significantly higher than the plate 1 group (level of evidence: level IV, case series, treatment study).