• Title/Summary/Keyword: plastic scintillator-based radiation detector

Search Result 9, Processing Time 0.023 seconds

Development of a muon detector based on a plastic scintillator and WLS fibers to be used for muon tomography system

  • Chanwoo Park;Kyu Bom Kim;Min Kyu Baek;In-soo Kang;Seongyeon Lee;Yoon Soo Chung;Heejun Chung;Yong Hyun Chung
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.1009-1014
    • /
    • 2023
  • Muon tomography is a useful method for monitoring special nuclear materials (SNMs) such as spent nuclear fuel inside dry cask storage. Multiple Coulomb scattering of muons can be used to provide information about the 3-dimensional structure and atomic number(Z) of the inner materials. Tomography using muons is less affected by the shielding material and less harmful to health than other measurement methods. We developed a muon detector for muon tomography, which consists of a plastic scintillator, 64 long wavelength-shifting (WLS) fibers attached to the top of the plastic scintillator, and silicon photomultipliers (SiPMs) connected to both ends of each WLS fiber. The muon detector can acquire X and Y positions simultaneously using a position determination algorithm. The design parameters of the muon detector were optimized using DETECT2000 and Geant4 simulations, and a muon detector prototype was built based on the results. Spatial resolution measurement was performed using simulations and experiments to evaluate the feasibility of the muon detector. The experimental results were in good agreement with the simulation results. The muon detector has been confirmed for use in a muon tomography system.

Radionuclide identification based on energy-weighted algorithm and machine learning applied to a multi-array plastic scintillator

  • Hyun Cheol Lee ;Bon Tack Koo ;Ju Young Jeon ;Bo-Wi Cheon ;Do Hyeon Yoo ;Heejun Chung;Chul Hee Min
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3907-3912
    • /
    • 2023
  • Radiation portal monitors (RPMs) installed at airports and harbors to prevent illicit trafficking of radioactive materials generally use large plastic scintillators. However, their energy resolution is poor and radionuclide identification is nearly unfeasible. In this study, to improve isotope identification, a RPM system based on a multi-array plastic scintillator and convolutional neural network (CNN) was evaluated by measuring the spectra of radioactive sources. A multi-array plastic scintillator comprising an assembly of 14 hexagonal scintillators was fabricated within an area of 50 × 100 cm2. The energy spectra of 137Cs, 60Co, 226Ra, and 4K (KCl) were measured at speeds of 10-30 km/h, respectively, and an energy-weighted algorithm was applied. For the CNN, 700 and 300 spectral images were used as training and testing images, respectively. Compared to the conventional plastic scintillator, the multi-arrayed detector showed a high collection probability of the optical photons generated inside. A Compton maximum peak was observed for four moving radiation sources, and the CNN-based classification results showed that at least 70% was discriminated. Under the speed condition, the spectral fluctuations were higher than those under dwelling condition. However, the machine learning results demonstrated that a considerably high level of nuclide discrimination was possible under source movement conditions.

Light Collection Efficiency of Large-volume Plastic Scintillator for Radiation Portal Monitor (방사선 포털 모니터용 대용적 플라스틱 섬광체 내부 빛 수집 효율 평가)

  • Lee, Jin Hyung;Kim, Jong Bum
    • Journal of Radiation Industry
    • /
    • v.11 no.3
    • /
    • pp.157-165
    • /
    • 2017
  • In this paper, we calculate the light photons collection efficiency of large-volume plastic scintillation detector mainly used for radiation portal monitor (RPM). A Monte Carlo light photon transport code, DETECT2000, were used to quantitatively evaluate light collection efficiency of plastic scintillation detector. DETECT2000 calculated the placement of light collection efficiency based on the energy spectrum. We calculated the light collection efficiency relative to the position of the energy spectrum that proportional to the placement of the source. The $850{\times}285{\times}65mm^3$ size of polyvinyl toluene (PVT) scintillator was used for measurements. Through DETECT2000 simulation, the light collection efficiency of $5{\times}5$ arrays were calculated and verification was performed by comparing with experimentally measured. And then, the corrected MCNP simulation by applying the light collection efficiency in $21{\times}13$ arrays was compared and analyzed. Comparing the Monte Carlo simulation with measured results, it shows an average difference of 10.1% in $5{\times}5$ arrays. Particularly, about twice of the difference was found in the edge of first column, which coupled with PMT. In whole $5{\times}5$ array, the overall ratio was the same except for the first column. And then comparing the energy spectra of the $21{\times}13$ array with and without the light collection efficiency, it shows a difference of 6.69% in Compton edge area. The DETECT2000 based light collection efficiency simulation showed well agreement with the point source experiment. And comparing with measured energy spectra, we could compare the differences according to whether or not the light collection efficiency was applied. As a results, it is possible to increase the accuracy and reliability of Monte Carlo simulation results by pre-calculating the light collection efficiency according to the PVT geometry by using the DETECT2000.

Characteristics of Radiation-Resistant Real-Time Neutron Monitor for Accelerator-Based BNCT

  • Nakamura, Takemi;Sakasai, Kaoru;Nakashima, Hiroshi;Takamiya, Koichi;Kumada, Hiroaki
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.105-109
    • /
    • 2016
  • Background: For an accelerator-based BNCT, we have fabricated a new detector consisting of quartz optical fibers that have excellent radiation-resistant characteristics. Materials and Methods: The developed detectors were irradiated at Kyoto University Research Reactor. Results and Discussion: The experimental results showed that the new detector had good output linearity for the neutron intensity, and the response of the new detector did not decrease during the irradiation. Conclusion: The new detector consisting of quartz optical fibers can be applied to measurement of neutron field of an accelerator-based BNCT.

Fabrication of 7-Diethylamino-4-methylcoumarin-based Scintillator for Gamma Radiation Detection (7-Diethylamino-4-methylcoumarin 기반 섬광체 제작 및 방사능 검출특성평가)

  • Sujung Min;Changhyun Roh;Bumkyoung Seo;Sangbum Hong
    • Journal of Radiation Industry
    • /
    • v.17 no.1
    • /
    • pp.69-73
    • /
    • 2023
  • Commercially used organic scintillation materials (1,4 di[2-(5phenyloxazolyl)] benzene) have low solubility in solvents and a wide emission energy range, which causes a decrease in detection efficiency. In this study, an organic liquid scintillator with improved detection efficiency was developed using 7-Diethylamino-4-methylcoumarin material to compensate for the disadvantages of existing organic scintillation detectors. And to evaluate the applicability of radiation measurement, the performance of a commercial plastic detector was compared. As a result of analyzing the 60Co detection characteristics by applying 7-Diethylamino-4-methylcoumarin as an alternative to 1,4 di[2-(5phenyloxazolyl)] benzene, the detection efficiency was improved around 2% compared with commercial scintillator when the 7-Diethylamino-4-methylcoumarin content was 0.04 wt%. Based on the results of this study, the possibility of improving detection efficiency through scintillator material modification was confirmed. In addition, since it is possible to discriminate nuclide through the spectrum correction algorithm, it will be possible to inspect and classify various decommissioning wastes generated during the decommissioning process.

Design and characterization of a Muon tomography system for spent nuclear fuel monitoring

  • Park, Chanwoo;Baek, Min Kyu;Kang, In-soo;Lee, Seongyeon;Chung, Heejun;Chung, Yong Hyun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.601-607
    • /
    • 2022
  • In recent years, monitoring of spent nuclear fuel inside dry cask storage has become an important area of national security. Muon tomography is a useful method for monitoring spent nuclear fuel because it uses high energy muons that penetrate deep into the target material and provides a 3-D structure of the inner materials. We designed a muon tomography system consisting of four 2-D position sensitive detector and characterized and optimized the system parameters. Each detector, measuring 200 × 200 cm2, consists of a plastic scintillator, wavelength shifting (WLS) fibers and, SiPMs. The reconstructed image is obtained by extracting the intersection of the incoming and outgoing muon tracks using a Point-of-Closest-Approach (PoCA) algorithm. The Geant4 simulation was used to evaluate the performance of the muon tomography system and to optimize the design parameters including the pixel size of the muon detector, the field of view (FOV), and the distance between detectors. Based on the optimized design parameters, the spent fuel assemblies were modeled and the line profile was analyzed to conduct a feasibility study. Line profile analysis confirmed that muon tomography system can monitor nuclear spent fuel in dry storage container.

Fabrication of Miniature Radiation Sensor Using Plastic Optical Fiber for Medical Usage (플라스틱 광섬유를 이용한 초소형 의료용 방사선 센서 제작)

  • Hwang, Young-Muk;Cho, Dong-Hyun;Cho, Hyo-Sung;Kim, Sin;Lee, Bong-Soo
    • Journal of radiological science and technology
    • /
    • v.28 no.1
    • /
    • pp.9-12
    • /
    • 2005
  • In this study, film type radiation sensor tips are fabricated for remote sensing of X or g-ray with inorganic scintillators and plastic optical fiber. The visible range of light from the inorganic scintillator that is generated by X and g-ray is guided by the plastic optical fiber and is measured by optical detector and power-meter. It is expected that the fiber-optic radiation sensor which is possible to be developed based on this study is used for remote, fast and exact sensing of X or g-ray because of its characteristics such as very small size, light weight and no interference to electromagnetic fields.

  • PDF

Planning and Dosimetric Study of Volumetric Modulated Arc Based Hypofractionated Stereotactic Radiotherapy for Acoustic Schwannoma - 6MV Flattening Filter Free Photon Beam

  • Swamy, Shanmugam Thirumalai;Radha, Chandrasekaran Anu;Arun, Gandhi;Kathirvel, Murugesan;Subramanian, Sai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.12
    • /
    • pp.5019-5024
    • /
    • 2015
  • Background: The purpose of this study was to assess the dosimetric and clinical feasibility of volumetric modulated arc based hypofractionated stereotactic radiotherapy (RapidArc) treatment for large acoustic schwannoma (AS >10cc). Materials and Methods: Ten AS patients were immobilized using BrainLab mask. They were subject to multimodality imaging (magnetic resonance and computed tomography) to contour target and organs at risk (brainstem and cochlea). Volumetric modulated arc therapy (VMAT) based stereotactic plans were optimized in Eclipse (V11) treatment planning system (TPS) using progressive resolution optimizer-III and final dose calculations were performed using analytical anisotropic algorithm with 1.5 mm grid resolution. All AS presented in this study were treated with VMAT based HSRT to a total dose of 25Gy in 5 fractions (5fractions/week). VMAT plan contains 2-4 non-coplanar arcs. Treatment planning was performed to achieve at least 99% of PTV volume (D99) receives 100% of prescription dose (25Gy), while dose to OAR's were kept below the tolerance limits. Dose-volume histograms (DVH) were analyzed to assess plan quality. Treatments were delivered using upgraded 6 MV un-flattened photon beam (FFF) from Clinac-iX machine. Extensive pretreatment quality assurance measurements were carried out to report on quality of delivery. Point dosimetry was performed using three different detectors, which includes CC13 ion-chamber, Exradin A14 ion-chamber and Exradin W1 plastic scintillator detector (PSD) which have measuring volume of $0.13cm^3$, $0.009cm^3$ and $0.002cm^3$ respectively. Results: Average PTV volume of AS was 11.3cc (${\pm}4.8$), and located in eloquent areas. VMAT plans provided complete PTV coverage with average conformity index of 1.06 (${\pm}0.05$). OAR's dose were kept below tolerance limit recommend by American Association of Physicist in Medicine task group-101(brainstem $V_{0.5cc}$ < 23Gy, cochlea maximum < 25Gy and Optic pathway <25Gy). PSD resulted in superior dosimetric accuracy compared with other two detectors (p=0.021 for PSD.