• 제목/요약/키워드: plastic limit

검색결과 508건 처리시간 0.028초

소성영역 진전효과를 고려한 공간 뼈대구조의 비탄성 해석 (Inelastic Analysis of Space Steel Frames Considering Spread of Plasticity)

  • 한재영;김성보
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.45-52
    • /
    • 2003
  • A finite element procedure to estimate ultimate strength of space frames considering spread of plasticity is presented. The improved displacement field is introduced based on inclusion of second order terms of finite rotations. All the nonlinear terms due to bending and torsional moment as well as axial force are precisely considered. The concept of plastic hinge is introduced and the incremental load/displacement method is applied for the elasto-plastic analysis. The initial yield surface is defined based on the residual stress and the full plastification surface is considered under the combined action of axial force, bending and torsional moments. The elasto-plastic stiffness matrices are derived using the flow rule and the normality condition of the limit function. Finite element solutions for ultimate strength of space frames are compared with available solutions and experimental results.

  • PDF

FOA (first-order-analysis) model of an expandable lattice structure for vehicle crash energy absorption of an inflatable morphing body

  • Lee, Dong-Wook;Ma, Zheng-Dong;Kikuchi, Noboru
    • Structural Engineering and Mechanics
    • /
    • 제37권6호
    • /
    • pp.617-632
    • /
    • 2011
  • A concept of crash energy absorbing (CEA) lattice structure for an inflatable morphing vehicle body (Lee et al. 2008) has been investigated as a method of providing rigidity and energy absorption capability during a vehicular collision (Lee et al. 2007). A modified analytical model for the CEA lattice structure design is described in this paper. The modification of the analytic model was made with a stiffness approach for the elastic region and updated plastic limit analysis with a pure plastic bending deformation concept and amended elongation factors for the plastic region. The proposed CEA structure is composed of a morphing lattice structure with movable thin-walled members for morphing purposes, members that will be locked in designated positions either before or during the crash. What will be described here is how to model the CEA structure analytically based on the energy absorbed by the CEA structure.

이상화 구조요소법에 의한 골조구조물의 최종강도해석에 관한 연구 (A Study on the Ultimate Strength Analysis of Frame Structures by Idealized Structural Unit Method)

  • 백점기;임화규
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1990년도 가을 학술발표회 논문집
    • /
    • pp.28-33
    • /
    • 1990
  • This paper presents an efficient and accurate method for nonlinear analysis of frame structures by idealized structural unit method. The main idea behind the present method is to minimize the cost of the computational effort by reducing the number of unknowns. An explicit form of the tangential elastic stiffness matrix of the element is derived by using updated Lagrangian approach. An ultimate limit state of the element is judged on the basis of the formation of a plastic hinge mechanism. The elasto-plastic stiffness matrix and the post-ultimate stiffness matrix of the element are formulated by plastic node method. A comparison between the present method is very efficient and accurate because the computing time required is very small while giving the accurate solution.

  • PDF

집중하중을 받는 Grillage의 소성 붕괴하중 산정 및 일반식 도출 (Formulation of General Equations for Plastic Collapse Loads of Grillages under a Lateral Point Load)

  • 홍기섭;김기성
    • 대한조선학회논문집
    • /
    • 제41권6호
    • /
    • pp.91-101
    • /
    • 2004
  • For the grillage which is common types of structures in marine and land-based structural system, the elastic response and design methods are usually applied. However, plastic analysis and design methods are considered Tn those structures to maintain the structural stability at the limit states. In grillage design, the central intersection point load may be used as a worst loading condition. However, a point load may often move around on the grid system. in such case, the worst load point would not necessarily be at the central point. To investigate the variation of plastic collapse load according to the location of moving load between intersections, the plastic collapse loads are obtained for the three types of grillages with simply-supported ends. From the result of each case, it is confirmed that the worst load point is located between intersections. General formulae related with plastic collapse loads for the three groups of grillages with simply-supported boundaries are derived. Those plastic collapse formulae for the grillages are applied to the design of pontoon deck, and optimum design procedure is illustrated. Consequently, general formulae for the plastic collapse of grillages derived from this study can be easily applied to the plastic analysis and optimum design of similar grillages.

수정 다층 모델을 이용한 이력곡선의 묘사 (Description of Hysteresis Loops using Modified Overlay Model)

  • 윤삼손;홍성구;이순복
    • 대한기계학회논문집A
    • /
    • 제27권11호
    • /
    • pp.1856-1863
    • /
    • 2003
  • Overlay model had several advantages to describe hysteretic behavior of material and showed good capability for many engineering materials. However, this model is only applicable to material obeying Masing postulate. Some materials such as 316L stainless steel do not follow Masing postulate and show cyclic hardening(or softening) and strain range dependence. Low cycle fatigue tests of 316L stainless steel at 600$^{\circ}C$ were performed to investigate the characteristics of cyclic behavior of non-Masing material. From all tests cyclic softening was observed. There were differences in elastic limit of hysteresis loop according to applied strain range. To consider these features, modified overlay model was developed. Yield stresses of subelements were divided into isotropic and anisotropic part to describe the non-Masing behavior. The plastic strain range memorization was introduced to consider the strain range dependence. The prediction using modified overlay model showed a good accordance to actual hysteresis loops.

특수합금 사각봉 모넬 소재의 탄성영역 압출 및 인발 특성 비교 해석 (Comparative Analysis on Characteristics of Extrusion and Drawing for Monel Material of Special Alloy with Rectangular Bar in Elastic Limit)

  • 양영준
    • 한국산업융합학회 논문집
    • /
    • 제27권3호
    • /
    • pp.573-580
    • /
    • 2024
  • Recently, the special alloy, for instance, such as Monel and Inconel, is used for valves, bolt/nuts, and fittings in semiconductor facility, FCEV(fuel cell electric vehicle) and hydrogen gas station, to reduce the hydrogen embrittlement. Even though the Monel material has high cost, it is recommended to use for the cases of ultra high pressure, ultra high leak-proof and so on. The purpose of this study is to investigate the characteristics of Monel material within elastic limit through the comparative analysis when Monel material is extruded or drawn. As the results, the deformation of Monel material was increased as the number of pass was increased, further, the deformation of Monel material by drawing was larger than that by extrusion. In the safety factor, the case that load is less than 420kN, the plastic deformation due to drawing could be happened faster than that due to extrusion. However, the case of more than 420kN, it showed that the plastic deformation for extrusion and drawing was almost similar.

원형 감육이 발생한 중수로 피더관의 한계하중 평가 (Limit Loads for Circular Wall-Thinned Feeder Pipes Subjected to Bending and Internal Pressure.)

  • 제진호;이국희;정하주;김종성;김윤재
    • 대한기계학회논문집A
    • /
    • 제34권11호
    • /
    • pp.1675-1680
    • /
    • 2010
  • 캐나다형 중수로에서 피더관은 가동 중에 유동 가속 부식에 의해 감육이 발생한다. 피더관에 감육이 발생하면 배관 건전성이 떨어진다. 본 논문은 원형 감육이 발생한 피더관에서의 기기신뢰성 평가를 위한 한계 하중을 연구하였다. 유한요소 해석을 통하여 면내 굽힘 하중과 내압을 받는 경우에 대하여 연구하였다. 재료는 대변형 효과를 고려하고 탄성-완전소성 재료로 가정하였다. 원형 감육이 발생한 피더관에 대하여 내압과 닫힘 방향, 열림 방향 굽힘 하중에 대하여 한계하중해를 제시하였다.

어린이 제품 중 가스 크로마토그래피를 이용한 알러지 유발 방향성 물질의 동시분석법 (Simultaneous determination of aromatic material causing allergic in children's products by Gas Chromatography)

  • 고경목;유찬주;김종원;이석기
    • 분석과학
    • /
    • 제31권1호
    • /
    • pp.23-30
    • /
    • 2018
  • 어린이 제품 중 22 종의 알러지 유발 방향성 물질들을 기체 크로마토그래피 불꽃 이온화 검출기(GC-FID)와 기체 크로마토그래피 질량 분석기(GC-MSD)를 사용하여 분석하였다. 분석물질들은 자동속슬렛 추출장치를 사용하여 추출하였으며, 고속 냉동 원심분리기에서 10분동안 원심분리 후 상징액을 2 mL vial 옮겨 Split mode로 주입하여 분석하였다. 확립된 조건에서 검정곡선은 0.996 이상의 상관계수를 갖는 직선성을 보였으며, 감도의 경우는 6.7~1,859,839로서 물질별로 기기특성 및 검출기에 따라 상당히 넓은 범위의 감도를 나타내었다. 기기검출한계는 $0.0032{\sim}0.0335{\mu}g/mL$로서 최대 약 $0.1{\mu}g/mL$이하의 기기검출한계를 나타내었고, 방법검출한계는 $0.0033{\sim}0.1161{\mu}g/mL$의 범위를 나타내었다. 또한 정량한계는 $0.0100{\sim}0.5422{\mu}g/mL$의 범위를 보였고, 정밀도는 0.21~4.89 %, 정확도는 89~111%의 범위를 나타내었다. 본 연구에서 개발한 분석법으로 시판품에 실제 적용하였다.

성형외과 의원의 평면 결정 요인에 관한 연구 - 2000년 이후 국내 사례를 중심으로 - (A Study on the factors for determining the layout of plan in Plastic Surgical Clinic - Focused on the after 2000's in domestic cases -)

  • 박보혜;문정묵
    • 한국실내디자인학회논문집
    • /
    • 제17권6호
    • /
    • pp.161-169
    • /
    • 2008
  • Recently, appearance is recognized as competitiveness as well as self expressing means, so understanding of general people have been rapidly changed. Also, since modem people have interest in an operation as well as various cosmetic treatment fields, a plastic surgery clinic is expanding its region to laser treatment and skin care for modem people. However, the plastic surgery clinic is not located in a building for only hospitals, but located in general neighborhood living facilities or an office building, so medical treatment is performed at the place. It is often found that a building plan can not conform to conditions that the hospital requires. This study is to understand a plane deciding factor of the plastic surgery clinic by analyzing it in a limit of building space and functional aspects of the plastic surgery clinic. A study method is first to investigate space composition according to the function, area allocation according to the function and a space privacy region after classifying study objects into large, middle, small scales so as to understand a functional role of the plastic surgery clinic, and secondly to analyze on the base of length of long and short edges of space and a moving line system after classifying common space types of the plastic surgery clinic through plane analysis of the study objects. As a result of the study, functional space difference according to the scale was shown, and the common space types were affected by length of the long and short edges, and it can influence space composition.

Reducing the donor site morbidity in radial forearm free flaps by utilizing a narrow radial forearm free flap

  • Shaikh, Safdar Ali;Bawa, Amber;Shahzad, Noman;Yousufzai, Zara;Ghani, Muhammad Shahab
    • Archives of Plastic Surgery
    • /
    • 제45권4호
    • /
    • pp.345-350
    • /
    • 2018
  • Background The radial forearm free flap (RFFF) has remained a leading choice of many plastic surgeons as a fasciocutaneous flap due to its versatility, pedicle length, and simple elevation technique. However, donor site morbidity has led many reconstructive surgeons to limit their use of the RFFF and to use other flaps instead. We propose that using a narrow RFFF (nRFFF) decreases the aesthetic and functional morbidity of the donor site. Methods We report our experiences with the nRFFF from April 2012 through May 2015 at the Department of Plastic, Reconstructive, and Hand Surgery at Liaquat National Hospital, Karachi. The donor defects were closed primarily. The Stony Brook Scar Evaluation Scale and comparison with the contralateral hand were used to assess aesthetic and functional outcomes, respectively. Results A total of 24 patients underwent nRFFF procedures during the study period. The donor arm showed excellent motor function in 22 cases (91.7%), and very good function in the remaining two cases (8.3%). The aesthetic outcomes were excellent in four patients (16.6%), very good in eight patients (33.3%), good in 10 patients (41.6%), and fair in two patients (8.3%) who developed a hypertrophic scar. All flaps were successful and there were no cases of partial or complete loss. Conclusions For small to medium-sized soft tissue defects, the nRFFF had acceptable outcomes due to its thinness, pliability, and major reduction in donor site aesthetic and functional morbidity.