• 제목/요약/키워드: plastic joint

검색결과 594건 처리시간 0.03초

현가장치 볼 조인트의 동적 모델 연구 (Dynamic Modeling of Ball Joint in Suspension)

  • 김숙희;한형석;노규석;김명규;김기훈
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1561-1564
    • /
    • 2003
  • In the dynamic analysis model of full vehicles, the ball joint is usually modeled as an ideal joint. Searching a ball joint, the engineering plastic covers metal and the plastic has little compliance. It is expected that the compliance will physically have an influence on load transfer. This thesis presents a dynamic model considering the compliance of a ball joint, and studies an influence related to load transfer. It models the compliance of a ball joint to 3 directional spring. Likewise, it researches the load of a ball joint via a four-post simulation of a full vehicle, comparing with a model considered compliant and the model of an ideal joint. As a result, the difference between the compliance and the ideal joint model was determined. For this reasons, to conduct precision load prediction for durability analysis, dynamic analysis considering the compliance of bali joint should be required.

  • PDF

Orthognathic treatment of facial asymmetry due to temporomandibular joint ankylosis

  • Gulsen, Ayse;Sibar, Serhat;Ozmen, Selahattin
    • Archives of Plastic Surgery
    • /
    • 제45권1호
    • /
    • pp.74-79
    • /
    • 2018
  • The aim of this study was to present a case series of the orthognathic treatment of facial asymmetry due to temporomandibular joint (TMJ) ankylosis and to characterize the current treatment modalities through a literature review. Four patients who presented with facial asymmetry due to TMJ ankylosis between 2010 and 2014 were included in this study. TMJ ankylosis was surgically treated before bimaxillary surgery with advancement genioplasty in some of the cases. In 2 cases, 3-dimensional (3D) models were used for diagnosis and treatment planning, as 3D models are very important tools for planning surgical maneuvers. Aesthetically pleasant facial symmetry and a good facial profile were obtained in all the cases.

BLP 패키지의 솔더 조인트의 신뢰성 연구 (Solder Joint Reliability of Bottom-leaded Plastic Package)

  • 박주혁
    • 한국마이크로전자및패키징학회:학술대회논문집
    • /
    • 한국마이크로전자및패키징학회 2002년도 춘계 기술심포지움 논문집
    • /
    • pp.79-84
    • /
    • 2002
  • The bottom-leaded plastic(BLP) packages have attracted substantial attention since its appearance in the electronic industry. Since the solder materials have relatively low creep resistance and are susceptible to low cycle fatigue, the life of the solder joints under the thermal loading is a critical issue for the reliability The represent study established a finite element model for the analysis of the solder joint reliability under thermal cyclic loading. An elasto-plastic constitutive relation was adopted for solder materials in the modeling and analysis. A 28-pin BLP assembly is modeled to investigate the effects of various epoxy molding compound, leadframe materials on solder joint reliability. The fatigue life of solder joint is estimated by the modified Coffin-Hanson equation. The two coefficients in the equation are also determined. A new design for lead is also evaluated by using finite element analysis. Parametric studies have been conducted to investigate the dependence of solder joint fatigue life on various package materials.

  • PDF

Volar plate avulsion fracture alone or concomitant with collateral ligament rupture of the proximal interphalangeal joint: A comparison of surgical outcomes

  • Kim, Yong Woo;Roh, Si Young;Kim, Jin Soo;Lee, Dong Chul;Lee, Kyung Jin
    • Archives of Plastic Surgery
    • /
    • 제45권5호
    • /
    • pp.458-465
    • /
    • 2018
  • Background Volar plate avulsion fracture of the proximal interphalangeal (PIP) joint is one of the most common hand injuries. In this study, we divided patients into two groups: patients with pure volar plate avulsion fracture, and patients with volar plate avulsion fracture concomitant with collateral ligament rupture. The purpose of this study was to compare long-term surgical outcomes between the two groups. As a secondary measure, the Mitek bone anchoring and polydioxanone (PDS) bone suturing techniques were compared. Methods A single-institutional retrospective review of the surgical treatment of volar plate avulsion fracture was performed. The cases were divided into those with pure volar plate avulsion fracture (group A, n=15) and those with volar plate avulsion fracture concomitant with collateral ligament rupture (group B, n=15). Both groups underwent volar plate reattachment using Mitek bone anchoring or PDS bone suturing followed by 2 weeks of immobilization in a dorsal protective splint. Results The average range of motion of the PIP joint and extension lag were significantly more favorable in group A (P<0.05). Differences in age; follow-up period; flexion function; visual analog scale scores; disabilities of the arm, shoulder, and hand scores; and the grip strength ratio between the two groups were non-significant. No significant differences were found in the surgical outcomes of Mitek bone anchoring and PDS bone suturing in group A. Conclusions Overall, the surgical outcomes of volar plate reattachment were successful irrespective of whether the collateral ligaments were torn. However, greater extension lag was observed in cases of collateral ligament injury.

인공관절 전치환 성형 수술 전후의 일상활동 장애정도 및 삶의 만족도 비교연구 - 관절 질환 환자를 중심으로 - (A Comparative Study of the Handicaps in and Satisfaction with the Ordinary Life before and after the Plastic Operation for Artificial Joint Replacement-Centering around Those Who suffer from Joint Diseases)

  • 강신화
    • 근관절건강학회지
    • /
    • 제3권1호
    • /
    • pp.37-49
    • /
    • 1996
  • The joint diseases threaten modern people's healthy life. They bring about a long pain, an anasarca, loss of joint function or even deformation and rigidity of joint, limiting people's ordinary activities much. The chronic joint patients may be subject to some hypochondria caused by anxiety for their life, social isolation, financial problem and physical disability. Therefore, this population should continue to be duely taken care of by medical personnels. In particular, nurses should adequately help these people to recover and improve their health through suitable adaptations. With such basic conceptions in mind, this study was aimed at reviewing these patients' conditions in their ordinary life before and after a plastic operation for artificial joint replacement as well as their satisfaction with their life. For this purpose, those patients who underwent some plastic operations for artificial joint replacement at university hospitals in Seoul from January 2, 1993 to June 30, 1995 were selected as the population of this study. Among them, 87 people were randomly sampled to answer a questionnaire designed specially. For the surveying tools, Jette's (1980) scale was applied to address the sample people's inconveniences experienced and supports received in their ordinary life, while the scale of Wood, Wylie & Sheafer was used to measure their satisfaction with their life. The collected data were analyzed for percentiles, means, SD, t-test and Pearson's correlations. The results of survey can be summarized as follows ; As a result of t-test the frequencies of other people's support before and after the plastic operation, it was disclosed that those who underwent the operation were supported less frequently. In addition, as a result of t-testing their satisfaction with life before and after the operation, it was found that the operation increased their satisfaction with life significantly. Meanwhile, as a result of t-test inconveniences, frequencies of supports and life satisfaction before and after the plastic operation for artificial knee replacement, it was disclosed that only the inconveniences were significantly reduced after the operation. In contrast, the t-test the variables before and after the plastic operation for artificial hip replacement, it was found that only the frequencies of other people's supports were significant reduced after the operation. Furthermore, the differences 6 months, one year and two years after the plastic operation for artificial joint replacement were t-tested on the variables. As a result, it was disclosed that people's inconvenience, frequencies of supports and life satisfaction were not improved 6 months after the operation but their frequencies of supports decreased significantly one year after, while their inconveniences and life satisfaction were significantly improved two years after. As a result of analyzing the variables with Pearson's correlations, inconveniences and frequency of supports were negatively correlated significantly with the life satisfaction. In conclusion, the plastic operation for artificial joint replacement significantly improved people's living inconveniences, reduced their frequency of other people's support and enhanced their satisfaction with life. To break don the plastic operation for artificial knee replacement improved patients' inconveniences, while the plastic operation for artificial hip replacement not only improved patients' inconveniences but reduced the frequencies of other people's support also. Finally, the finding that the plastic operation for artificial joint replacement brought about the improvement two years after suggests that this period is needed for the patients to adapt themselves to the post-operation conditions.

  • PDF

수지 첨부 절단창의 재접합술 시 원위지 관절 고정과 운동 범위의 관계 (A Comparative Study of Range of Motion With or Without Distal Interphalangeal Joint Fixation in Replantation of the Amputated Fingertips)

  • 한승규;노시영;김진수;이동철;기세휘;양재원
    • Archives of Reconstructive Microsurgery
    • /
    • 제20권1호
    • /
    • pp.18-25
    • /
    • 2011
  • Purpose: In the process of replantation of the amputated fingertips, the primary concern was given to survival of the amputees, while the functional aspect of digits after the surgery has been easily neglected. Although an internal fixation with a K-wire is often a part of replantation of the amputated fingertips, little consideration had been given to the study of relationship between distal interphalangeal joint fixation and post operative range of motion. A comparative study in relation to post operative range of motion was done on two different groups, one group with K-wire insertion and the other group without a K-wire insertion at the distal interphalangeal joint. Materials and Methods: The study was done on the cases of a single digit amputation conducted at our institute (the age in the range of 10 to 60) in about four-year of time span from March of 2005 to March of 2009. The cases with a thumb replantation, osteomyelitis or articular surface injury have been excluded from this study. The cases of both head and shaft fracture, except the insertion site of tendon, of distal phalanx of internal fixation with a single K-wire were reviewed for this study. A group of 24 cases without distal interphalangeal joint fixation in comparison to a group of 22 cases with distal interphalangeal joint fixation was reviewed to assess the postoperative range of motion at distal interphalangeal joint on the 6th week after the surgery. And, on the 30th month after the surgery, a group of 10 cases without distal interphalangeal joint fixation in comparison to a group of 10 cases with joint fixation was reviewed. A K-wire was removed in about 5 weeks after the fracture was reunited under the radiographic image, immediately followed by a physical therapy. Result: The active range of motion for a group without interphalangeal joint fixation was measured $49.0^{\circ}$ on average, while $28.6^{\circ}$ was measured for a group with interphalengeal fixation on the 6th week after the surgery. On the 30th month after the surgery, the active range of motion was measured $52.0^{\circ}$ and $55.0^{\circ}$ on average for a group without and with interphalangeal fixation respectively. Conclusion: In the process of replantation of the amputated fingertips, short-term(on the 6th week) improvement of postoperative active motion of range can be expected in the cases without distal interphalangeal fixation in comparison to the cases of interphalangeal joint fixation with a K-wire. However, there seems to be no difference on motion of range in a long-term (on the 30th month) follow up period.

  • PDF

고관절 내외회전 가동범위 검사에 대한 범용플라스틱 측각기의 동시타당도와 임상적 유용성 (Concurrent Validity and Clinical Usefulness of Universal Plastic Goniometer for Hip Internal and External Rotation Range Measurement)

  • 김용욱
    • 대한물리의학회지
    • /
    • 제13권1호
    • /
    • pp.99-105
    • /
    • 2018
  • PURPOSE: The aim of this study was to evaluate the concurrent validity and clinical usefulness of the universal plastic goniometer to measure the range of motion of the internal and external rotation of the hip joint using the three dimensional motion analysis which can analyze the joints and segment movements in the most objective and quantitative method. METHODS: Clinical and kinematic data were collected from thirty individuals using a universal plastic goniometer and a ten camera motion analysis system. Passive hip rotation range was obtained three trials for left and right hip joints using two measure methods simultaneously. RESULTS: There were significant differences between all matching measures of the two measures of internal and external rotation of the hip joint (p<.05). The relationship between the two tests for all measurements of the internal and external rotation of the hip was statistically significant with correlation coefficient form r=.87 to .96. (p<.01). CONCLUSION: Clinical measurement of the internal and external rotation of the hip using a universal plastic goniometer is effective to assess the hip condition. However, application of universal plastic goniometer requires careful attention in more accurate evaluation and research verification of the internal and external rotation of hip joint.

Pedicled Perforator Flaps for Reconstruction of Bilateral Knee Defects: A Case Report

  • Park, Joo Seok;Hong, Joon Pio;Oh, Tae Suk
    • Archives of Reconstructive Microsurgery
    • /
    • 제23권2호
    • /
    • pp.101-104
    • /
    • 2014
  • Reconstruction of soft tissue defects of the knee has always been a challenging task for plastic surgeons. Various reconstructive choices are available depending on the location, size, and depth of the defect relative to the knee joint. Defects on the knee joint have several characteristic features. The use of a free flap is preferred for reconstructions involving obliteration of large-cavity defects, but recipient pedicle isolation can be difficult because of the extent of the injury zone. Furthermore, the true defect during knee joint flexion is larger than during knee joint extension, and a durable flap is necessary for joint movement. We report for the first time on the use of pedicled perforator flaps for reconstruction of bilateral knee defects in a 76-year-old woman. The operative procedure required skeletonizing the perforators of an antero-lateral thigh flap and antero-medial thigh flap and rotating the flap in the defect. The patient returned to normal daily activity and had a full range of motion two months after the accident. The shorter operating time with decreased donor site morbidity and its durability make this flap a valuable alternative for soft tissue reconstruction of the knee.

직접전단시험모델에 의한 뿌리말뚝의 탄소성조인트 유한요소해석 (Elasto-plastic Joint Finite Element Analysis of Root-pile Using the Direct Shear Test Model)

  • 한중근
    • 한국환경복원기술학회지
    • /
    • 제5권4호
    • /
    • pp.19-30
    • /
    • 2002
  • The stability of slope using root-pile like to the reinforcements is affected by the interaction behavior mechanism of soil-reinforcements. Through the studying on the interaction in joint of its, therefore, the control roles can be find out in installed slope. In study, the stress level ratio based on the insert angle of installed reinforcements in soil used to numerical analysis, which was results from the duty direct shear test in Lab. The maximum shear strain variation on the reinforcements was observed at insert angle, which was approximately similar to the calculated angle based on the equation proposed by the Jewell. The elasto-plastic joint model on the contact area of soil-reinforcements was presumed, the reinforced soil assumed non-linear elastic model and the reinforcements supposed elastic model, respectively. The finite element analysis of assumed models was performed. The shear strain variation of non-reinforced state obtained by the FEM analysis including elasto-plastic joint elements were shown the rationality of general limit equilibrium analysis for the slope failure mode on driving zone and resistance zone, which based on the stress level step according to failure ratio. Through the variation of shear strain for the variation of inserting angle of reinforcements, the different mechanism on the bending and the shear resistance of reinforcements was shown fair possibility.