• Title/Summary/Keyword: plasma synthesis

Search Result 464, Processing Time 0.024 seconds

Synthesis of C2 Chemicals from Methane in a Dielectric Barrier Discharge (DBD) Plasma Bed (메탄으로부터 촉매와 유전체 장벽 방전 반응기를 활용한 C2 화합물의 합성)

  • Oh, Ji-Hwan;Jeon, Jong Hyun;Jeoung, Jaekwon;Ha, Kyoung-Su
    • Korean Chemical Engineering Research
    • /
    • v.56 no.1
    • /
    • pp.125-132
    • /
    • 2018
  • The direct synthesis of $C_2$ chemical directly from methane was studied by employing catalysts with ordered mesopores in a dielectric barrier discharge plasma reactor. The reaction was carried out using MgO/OMA (ordered mesoporous alumina), $MgO/{\gamma}-Al_2O_3$ and $MgO/{\alpha}-Al_2O_3$ as catalysts. When MgO/OMA was applied, it showed excellent performance in the plasma reactor using pulse-type power supply and the selectivity of $C_2$ chemicals was measured as 67%. The effects of metal oxide type, textural property of support, alumina phase and power supply type on catalytic performance were investigated especially in terms of $C_2$ chemical formation. BET (Brunauer, Emmett, Teller), X-ray diffraction, transmission electron microscope and thermogravimetric analysis were used to investigate the characterization of the catalyst before and after the reaction.

Conversion Characteristics of CH4 and CO2 in an Atmospheric Pressure Plasma Reactor (대기압 플라즈마 반응기에서의 CH4와 CO2의 전환처리 특성)

  • Kim, Tae Kyung;Lee, Won Gyu
    • Applied Chemistry for Engineering
    • /
    • v.22 no.6
    • /
    • pp.653-657
    • /
    • 2011
  • Conversion characteristics of $CH_4$ and $CO_2$ was studied using an atmospheric pressure plasma for the preparation of synthesis gas composed of $H_2$ and CO. The effects of delivered power, total gas flow rate, and gas residence time in the reactor on the conversion of $CH_4$ and $CO_2$ were evaluated in a plasma reactor with the type of dielectric barrier discharge. The increase of reactor temperature did not affect on the increase of conversion if the temperature does not reach to the appropriate level. The conversion of $CH_4$ and $CO_2$ largely increased with increasing the delivered power. As the $CH_4/CO_2$ ratio increased, the $CH_4$ conversion decreased, whereas the $CO_2$ conversion increased. Generally, the $CH_4$ convesion was higher than the $CO_2$ conversion through the variation of the process parameters.

Effects of Dietary Fat Level and P/S Ratio on HDL-cholesterol, Total Cholesterol and Triglyceride in Plasma and Selected Tissues of Rats (식이의 총지방량과 P/S Ratio가 Plasma HDL-Cholesterol과 혈장 및 조직내의 지질함량에 미치는 영향)

  • Park, Hyun-Suh
    • Journal of Nutrition and Health
    • /
    • v.16 no.3
    • /
    • pp.200-208
    • /
    • 1983
  • The present studies were designed to compare the effects of both dietary fat levels and P / S ratio on lipid components in plasma and tissues. Changes in plasma HDL-cholesterol, cholesterol and TG, and also in tissue cholesterol and TG were determined in young rats fed diets providing total dietary fat as 10%, 25% or 45% of calories and P / S ratio as 0.2 or 4.0. Plasma cholesterol levels were getting higher as dietary fat levels increased at P / S 0.2. Plasma cholesterol was lower in rats fed dietary fat either 25% or 45 %, each with P / S 4.0. But at 10% no change in plasma cholesterol were observed by P / S 4.0 because of a possible insufficiency of the absolute amount of PUFA. HDL-cholesterol was rather less sensitive to the modification of dietary fat level, but was reduced in rats fed diets of P / S 4.0 at either 25% or 45% fat, even though HDL-cholesterol were increased in the group of 10% with P / S 0.2. Total cholesterol per g- liver were significantly increased as dietary fat levels increased. Liver cholesterol levels were higher in rats fed diets of P / S 4.0 at higher fat levels (25% or 45%) which possibly suggested that a reduction of plasma cholesterol by high PUFA diet was not at least from a decreased synthesis of cholesterol in liver. However, in muscle no significant differences were found by feeding high P / S ratio at each levels of fat. At 10% fat level, compared to 25% or 45%, cholesterol level was lower in g-liver but higher in g- muscle. Plasma TG was decreased as more dietary fat were supplied at P / S ratio, but no consistant response obtained at low P / S ratio. TG per g-liver were reduced by feeding P / S 4.0 diet at 10% or 45% fat level but no differences were found in muscle. P / S 4.0 diet was more efficient in lowering plasma cholesterol TG and HDL-cholesterolt levels only if fat level was more than 25% of the total calories And young rats were more resistant to dietary fat modification.

  • PDF

Thermal Plasma Synthesis of Nano Composite Particles (열플라즈마에 의한 복합 나노 입자 제조)

  • Jeong, Min-Hee;Kim, Heon-Chang
    • Applied Chemistry for Engineering
    • /
    • v.21 no.6
    • /
    • pp.676-679
    • /
    • 2010
  • Nano composite particles were synthesized from a bulk ZrVFe alloy ingot by transferred DC thermal plasma. Effects of plasma gas flow rate on the characteristics of the produced nano composite particles were investigated. The characteristics of the synthesized powder were analyzed by field scanning electron microscopy (FE-SEM), light scattering particle size analyzer (PSA), energy dispersive X-ray spectroscopy (EDS), X-ray diffractometer (XRD), and Brunauer-Emmett-Teller (BET) surface area analyzer. As the flow rate of plasma gas increased from 20 L/min to 40 L/min, the average particle size decreased from 91 nm to 55 nm, the particle size distribution became narrower, the surface area increased from $200\;m^2/g$ to $255\;m^2/g$, the particle composition was nearly unaffected, and the particle crystallinity was improved.

Synthesis of nano-crystalline Si films on polymer and glass by ICP-assisted RF magnetron sputtering

  • Shin, Kyung-S.;Choi, Yoon-S.;Choi, In-S.;Han, Jeon-G.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.203-203
    • /
    • 2010
  • Nano-crystalline Si thin films were deposited on polymer and glass by inductively coupled plasma (ICP) - assisted RF magnetron sputtering at low temperature in an argon and hydrogen atmosphere. Internal ICP coil was installed to increase hydrogen atoms dissociated by the induced magnetic field near the inlet of the working gases. The microstructure of deposited films was investigated with XRD, Raman spectroscopy and TEM. The crystalline volume fraction of the deposited films on polymer was about 70% at magnetron RF power of 600W and ICP RF power of 500W. Crystalline volume fraction was decreased slightly with increasing magnetron RF power due to thermal damage by ion bombardment. The diffraction peak consists of two peaks at $28.18^{\circ}$ and $47.10^{\circ}\;2{\theta}$ at magnetron RF power of 600W and ICP RF power of 500W, which correspond to the (111), (220) planes of crystalline Si, respectively. As magnetron power increase, (220) peak disappeared and a dominant diffraction plane was (111). In case of deposited films on glass, the diffraction peak consists of three peaks, which correspond to the (111), (220) and (311). As the substrate temperature increase, dominant diffraction plane was (220) and the thickness of incubation (amorphous) layer was decreased.

  • PDF

Plasma Phospholipids, including Plasmalogens, after Consumption of Diets Enriched in Long-chain n-3 Fatty Acids

  • Yeo, Young-K.;Kim, Jong-S.;Lee, Jong-R.;Lee, Ji-Y.;Chung, Sang-W.;Kim, Hyo-J.;Horrocks, Lloyd A.;Park, Young-S.
    • BMB Reports
    • /
    • v.33 no.6
    • /
    • pp.499-505
    • /
    • 2000
  • The level of long-chain n-3 fatty acids in chicken and pork can be increased by changing the diet of the animals. Increased levels of these essential fatty acids improve cardiovascular health in humans. The purpose of this study was to study the effects of the consumption of pork and chicken enriched in docosahexaenoic acid (DHA) on plasma lipids. The consumption of these products decreased the levels of two cardiovascular risk factors, LDL-cholesterol and triacylglycerols, in the plasma of female college students. The effect on LDL-cholesterol differed from that of fish oil, which does not affect the level of LDL-cholesterol. The proportions of DHA in the triacylglycerols and the glycerophospholipids were increased markedly. The greatest changes in the glycerophospholipids were in the ether types of the ethanolamine glycerophospholipids. Dietary DHA appears to be incorporated preferentially into the plasma ethanolamine plasmalogens, which can act as antioxidants. This agrees with our hypothesis that DHA stimulated the transcription of the genes for peroxisomal enzymes that are required for plasmalogen synthesis.

  • PDF

Simultaneous Determination of α-Amanitin and β-Amanitin in Mouse Plasma Using Liquid Chromatography-High Resolution Mass Spectrometry

  • Bang, Young Yoon;Lee, Min Seo;Lim, Chang Ho;Lee, Hye Suk
    • Mass Spectrometry Letters
    • /
    • v.12 no.3
    • /
    • pp.112-117
    • /
    • 2021
  • α-Amanitin and β-amanitin are highly toxic bicyclic octapeptides responsible for the poisoning of poisonous mushrooms such as Amanita, Galerina, and Lepiota by inhibiting RNA polymerase II, DNA transcription, and protein synthesis. A sensitive, simple, and selective liquid chromatography-high resolution mass spectrometric method using parallel reaction monitoring mode was developed and validated for the simultaneous determination of α- and β-amanitin in mouse plasma to evaluate the toxicokinetics of α- and β-amanitin in mice. Protein precipitation of 5 μL mouse plasma sample with methanol as sample clean-up procedure and use of negative electrospray ionization resulted in better sensitivity and less matrix effect. The calibration curves for α- and β-amanitin in mouse plasma were linear over the range of 0.5-500 ng/mL. The intra- and inter-day coefficient of variations and accuracies for α- and β-amanitin at four quality control concentrations were 3.1-14.6% and 92.5-115.0%, respectively. The present method was successfully applied to the toxicokinetic study of α- and β-amanitin after an oral administration of α- and β-amanitin at 1.5 mg/kg dose to male ICR mice.

Associations among plasma vitamin C, epidermal ceramide and clinical severity of atopic dermatitis

  • Shin, Jihye;Kim, You Jin;Kwon, Oran;Kim, Nack-In;Cho, Yunhi
    • Nutrition Research and Practice
    • /
    • v.10 no.4
    • /
    • pp.398-403
    • /
    • 2016
  • BACKGROUND/OBJECTIVES: Atopic dermatitis (AD), a chronic inflammatory skin disease, is accompanied by disruption of the epidermal lipid barrier, of which ceramide (Cer) is the major component. Recently it was reported that vitamin C is essential for de novo synthesis of Cer in the epidermis and that the level of vitamin C in plasma is decreased in AD. The objective of this study was to determine the associations among clinical severity, vitamin C in either plasma or epidermis, and Cer in the epidermis of patients with AD. SUBJECTS/METHODS: A total of 17 patients (11 male and 6 female) aged 20-42 years were enrolled. The clinical severity of AD was assessed according to the SCORAD (SCORing Atopic Dermatitis) system. Levels of vitamin C were determined in plasma and biopsies of lesional epidermis. Levels of epidermal lipids, including Cer, were determined from tape-stripped lesional epidermis. RESULTS: The clinical severity of patients ranged between 0.1 and 45 (mild to severe AD) based on the SCORAD system. As the SCORAD score increased, the level of vitamin C in the plasma, but not in the epidermis, decreased, and levels of total Cer and Cer2, the major Cer species in the epidermis, also decreased. There was also a positive association between level of vitamin C in the plasma and level of total Cer in the epidermis. However, levels of epidermal total lipids including triglyceride, cholesterol, and free fatty acid (FFA) were not associated with either SCORAD score or level of vitamin C in the plasma of all subjects. CONCLUSIONS: As the clinical severity of AD increased, level of vitamin C in the plasma and level of epidermal Cer decreased, and there was a positive association between these two parameters, implying associations among plasma vitamin C, epidermal Cer, and the clinical severity of AD.

Synthesis of Nanostructured Si Coatings by Hybrid Plasma-Particle Accelerating Impact Deposition (HP-PAID) and their Characterization (하이브리드 플라즈마 입자가속 충격퇴적(Hybrid Plasma - Particle Accelerating Impact Deposition, HP-PAID) 프로세스에 의한 Si 나노구조 코팅층의 제조 및 특성평가)

  • 이형직;권혁병;정해경;장성식;윤상옥;이형복;이홍림
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.12
    • /
    • pp.1202-1207
    • /
    • 2003
  • Using a recently developed Hybric Plasma-Particle Accelerating Impact Deposition (HP-PAID) process, synthesis of nanostructured silicon coatings has been investigated by injecting vapor-phase TEOS (tetraethosysilane, (C$_2$H$\_$5/O)$_4$Si) into an Ar hybrid plasma. The plasma jet with reactants was expanded through nozzle into a deposition chamber, with the pressure dropping from 700 to 10 torr. Ultrafine particles accelerated in the free jet downstream of the nozzle, deposited by an inertial impaction onto a temperature controlled substrate. By using this process, nanostructured amorphous silicon coatings with grain size smaller than 10 nm could be synthesized. These samples were annealed in an Ar and crystallized at 900$^{\circ}C$ for 30 min. TEM analysis showed that the annealed coatings were also composed of nanoparticles smaller than 10 nm, which showed a good consistency that the average grain size of 7 nm was also estimated from a peak shift of 2.39 cm$\^$-1/ and Full Width at Half Maximum (FWHM) 5.92 cm$\^$-1/ of Raman analysis. The noteworthy is that a strong PL peak at 398 nm was also obtained for this sample, which indicates that the deposited coatings also contained 3∼4 nm nanostructured grains.

Characterization and Construction of Chemical Vapor Deposition by using Plasma (rf 플라즈마 화학기상증착기의 제작 및 특성)

  • 김경례;김용진;현준원;이기호;노승정;최병구
    • Journal of the Korean institute of surface engineering
    • /
    • v.33 no.2
    • /
    • pp.69-76
    • /
    • 2000
  • The rf plasma chemical vapor deposition is a common method employed for diamond or amorphous carbon deposition. Diamond possesses the strongest bonding, as exemplified by a number of unique properties-extraordinary hardness, high thermal conductivity, and a high melting tempera tore. Therefore, it is very important to investigate the synthesis of semiconducting diamond and its use as semiconductor devices. An inductively coupled rf plasma CVD system for producing amorphous carbon films were developed. Uniform temperature and concentration profiles are requisites for the deposition of high quality large-area films. The system consists of rf matching network, deposition chamber, pumping lines for gas system. Gas mixtures with methane, and hydrogen have been used and Si (100) wafers used as a substrate. Amorphous carbon films were deposited with methane concentration of 1.5% at the process pressure of S torr~20 torr, and process temperature of about $750^{\circ}C$. The nucleation and growth of the amorphous carbon films have been characterized by several methods such as SEM and XRD.

  • PDF