• Title/Summary/Keyword: plasma frequency

Search Result 855, Processing Time 0.035 seconds

Effects of CP AP Therapy on Systemic Blood Pressure, Cardiac Rhythm and Catecholamines Concentration in Patients with Obstructive Sleep Apnea (폐쇄성 수면 무호흡에서 CPAP 치료가 전신성 혈압, 심조율 및 catecholamines 농도에 미치는 영향)

  • Kang, Ji-Ho;Lee, Sang-Haak;Choi, Young-Mee;Kwon, Soon-Seog;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Song, Jeong-Sup;Park, Sung-Hak;Moon, Hwa-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.6
    • /
    • pp.715-723
    • /
    • 2000
  • Background : Obstructive sleep apnea syndrome (OSAS) affects systemic blood pressure and cardiac function. The development of cardiovascular dysfunction including the changes of systemic blood pressure and cardiac rhythm, suggests that recurrent hypoxia and arousals from sleep may increase a sympathetic nervous system activity. Continuous positive airway pressure (CPAP) therapy has been found to be an effective treatment of OSAS. However, only a few studies have investigated the cardiovascular and sympathetic effects of CPAP therapy. We evaluated influences of nasal CPAP therapy on the cardiovascular system and the sympathetic activity in patients with OSAS. Methods : Thirteen patients with OSAS underwent CPAP therapy and were monitored using polysomnography, blood pressure, heart rate, presence of arrhythmia and the concentration of plasma catecholamines, before and with CPAP therapy. Results: The apnea-hypopnea index (AHI) was significant1y decreased (p<0.01) and the lowest arterial oxygen saturation level was elevated significantly after applying CPAP (p<0.01). Systolic blood pressure tended to decrease after CPAP but without statistical significance. Heart rates during sleep were not significantly different after CPAP. However, the frequency and number of types of arrhythmia decreased and sinus bradytachyarrhythmia disappeared after CPAP. Although there was no significant difference in the level of plasma epinephrine concentration, plasma norepinephrine concentration significantly decreased after CPAP (p<0.05). Conclusion : CPAP therapy decreased the apnea-hypopnea index, hypoxic episodes and plasma norepinephrine concentration. In addition, it decreased the incidence of arrhythmia and tended to decrease the systemic blood pressure. These results indicate that CPAP may play an important role in the prevention of cardiovascular complications in patients with OSAS.

  • PDF

Annual Reproductive Cycle and Changes in Plasma Levels of Sex Steroid Hormones of the Female Korean Dark Sleeper, Odontobutis platycephala (Iwata et Jeon) (동사리, Odontobutis platycephala (Iwata et Jeon) 암컷의 생식주기와 혈중 성스테로이드 호르몬의 변화)

  • LEE Won-Kyo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.31 no.4
    • /
    • pp.599-607
    • /
    • 1998
  • To clarify annual reproductive cycle of Korean dark sleeper, Odontobutis platycephala (Iwata et Jeon), we examined the seasonal changes of gonadosomatic index (GSI), the proportional frequency of oocyte development stages in the ovary and the changes of sex steroid hormone levels in blood from December 1995 to November 1997. In July and August, GSI was 0.35 to 0.72 and most oocytes in the ovary were chromatin-nucleolus stage and perinucleolar stage (proportional frequency: $87\%\~96\%$). In September, GSI was 1.20 $\pm$ 0.12, some oocytes in the ovary were yolk vesifle stage (proportional frequency: $22.8\%$) and vitellogenic stage which appeared very rarely(proportional frequency: $2.2\%$). GSI increased gradually from October and reached 4.59± 0.61 to December. During this period, oocytes of vitellogenic stage increased slightly (proportional frequency in December: $22.1\%$). In January, GSI was 4.32 $\pm$ 0.72 but the proportional frequency of oocytes in vitellogenic stage increased (proportional frequency: $51.2\%$). from February, GSI was increased sharply and reached to 10.51 $\pm$ 1.04 in March, the highest value throughout the year and the proportional frequency of oocytes in vitellogenic stage also reached the highest levels (proportional frequency: $60\%$). From April, GSI was gradually decreased and fell down to 1.11 $\pm$ 0.35 in June. During this period, the proportional frequency of mature oocytes was the highest in April (proportional frequency of mature oocyte stage: $40\%$ in April, $12\%$ May, $5\%$ June) throughout the year, and atretic ovarian follicles were appeared. The blood level of estradiol-17$\beta$ ($E_2$), which stimulates the hepatic synthesis and secretion of vitellogenin, was $0.84{\pm}0.20\;ng/m{\ell}$ in August, and thereafter was not changed until December. from January, it increased sharply and reached the highest level of $ 2.85{\pm}0.35\;ng/m{\ell}$ in March throughout the year, but fell to $0.14{\pm}0.02\;ng/m{\ell}$ in July(P<0.05), 17$\alpha$-hydroxprogesterone(17$\alpha$-OHP) was the peak $13.37{\pm}0.52ng/m{\ell}$ in March, but no significant changes in other period(below $3ng/m{\ell}$, P<0.05). 17$\alpha$, 20$\beta$-dihydroxy-4-pregnen-3-one(17$\alpha$, 20$\beta$-P), which was known as the final maturation inducing hormone in teleost, was $0.74{\pm}0.09ng/m{\ell}$ in April and $0.54{\pm}0.07ng/m{\ell}$ in May, but no significant changes in other period (below $0.26\;ng/m{\ell}$, p<0.05). Taken together these results, the annual reproductive cycle of O. platycephala divided into 4 periods as follows: 1) ripe and spawning period from April to June, main spawning period was from April to May, 2) Resting period from July to August, 3) Growing period from September to December, 4) Maturing period from January to March. Moreover, It was showed that the changes of sex steroid hormone in blood played a important roles in the annual reproductive cycle of O. platycephala.

  • PDF

The Clinical Summary of the Coronary Bypass Surgery (심장 관상동맥 외과)

  • 정황규
    • Journal of Chest Surgery
    • /
    • v.13 no.3
    • /
    • pp.174-185
    • /
    • 1980
  • It was my great nohour that I can be exposed to such plenty materials of the coronary bypass surgery. Here, I am summarizing the xoronary bypass surgery, clinically. The material is serial 101 patients who underwent coronary bypass surgery between July 17, 1979 to November 30, 1979 in Shadyside Hospital, University of Pittsburgh. 1. Incidence of the Atherosclerosis is frequent in white, male, fiftieth who are living in industrialized country. It has been told the etiologic factor of the atherosclerosis is hereditary, hyperlipidemia, hypertension, smoking, drinking, diabetes, obesity, stress, etc. 2. The main and most frequent complication of the coronary atherosclerosis is angina pectoris. Angina pectoris is the chief cause of coronary bypass surgery and the other causes of coronary bypass surgery are obstruction of the left main coronary artery, unstable angina, papillary muscle disruption or malfunction and ventricular aneurysm complicated by coronary artery disease. 3. The preoperative clinical laboratory examination shows abnormal elevation of plasma lipid in 82 patint, plasma glucose in 40 patient, total CPK-MB in 24 patient stotal LDH in 22 patient out of 101 patient. 4. Abnormal ECG findings in preoperative examine were 29.1% myocardial infarction, 25.8% ischemia and injury, 14.6T conduction defect. 5. Also we had done Echocardiography, Tread Mill Test, Myocardial Scanning, Vectorcardiography and Lung function test to get adjunctive benefit in prediction of prognosis and accurate diagnosis. 6. The frequency of coronary atherosclerosis in main coronary arteries were LAD, RCA and Circumflex in that order. 7. The patients' main complaints which were became as etiologic factor undergoing coronary bypass surgery were angina, dyspnea, diaphoresis, dizziness, nausea and etc. 8. For the coronary bypass surgery, we used cardiopulmonary bypass machine, non-blood, diluting prime, cold cardioplegic solution and moderate cooling for the myocardial protection. 9. We got the grafted veins from Saphenous and Cephalic vein. Reversed and anastomosed between aorta and distal coronary A. using 5-0 and 7-0 prolene continuous suture. Occasionally we used internal mammary A. as an arterial blood source and anastomosed to the distal coronary A. and to side fashion. 10. The average cardiopulmonary bypass time for every graft was 43.9 min. and aortic clamp time was 23 minute. We could Rt. coronary A. bypass surgery only by stand by the cardiopulmonary machine and in the state of pumping heart. 11. Rates by the noumbers of graft were as follow : 21.8% single, 33.7% double, 26.7% triple, 13.9% quadruple, 3% quintuple and 1% was sixtuple graft. 12. combined procedures with coronary bypass surgery were 6% aneurysmectomy, 3% AVR, 1% MVR, 13% pacer implantation and 1% intraaortic ballon setting. 13. We could see the complete abolition of anginal pain after operation in 68% of patient, improvement 25.8%, no change in 3.1%, and there was unknown in 3%. 14. There were 4% immediate postoperative deaths, 13.5% some kinds of heart complication, 51.3% lung complications 33.3% pleural complications as prognosis.

  • PDF

Characteristics of Diamond Like Carbon Film Fabricated by Plasma Enhanced Chemical Vapor Deposition Method with mixed Ar, N2 gas rate (혼합된 Ar, N2 가스 유량에 따른 PECVD 방법에 의하여 제작된 다이아몬드 상 탄소 박막의 특성)

  • Gang, Seong-Ho;Kim, Byeong-Jin;Bae, Gyeong-Tae;Ju, Seong-Hu
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.87-87
    • /
    • 2018
  • 다이아몬드 상 탄소(diamond-like carbon, DLC)는 상당량의 $sp^3$ 결합을 가지는 비정질 탄소(a-C) 또는 수소화 비정질 탄소(a-C:H)로 이루어진 준안정 형태의 탄소이다. DLC는 전기 저항과 굴절률이 높고 화학적으로 다른 물질과 반응하지 않으며, 마찰계수가 낮고 경도가 높아 자기 디스크, 광학 소자 등의 다양한 분야에서 적용되고 있다[1,2]. 또한 다이아몬드에 비해 상온에서 성장이 가능할 정도로 합성온도가 낮아 적용 기판의 제한이 거의 없고, 증착 방법과 조건에 따라 탄소 결합의 다양성과 비정질성이 변화하기 때문에 넓은 범위의 특성을 얻을 수 있는 장점이 있다. 지금까지 DLC 박막의 광학적 특성, 특히 굴절률, 광학적인 에너지 밴드 갭, 자외선과 적외선 투과성에 대해서는 많은 연구가 진행되었으나 가시광선의 투과성에 대한 연구는 제한적이며[4], 가시광선 투과도 개선에 대한 연구는 전무하다. 본 연구에서는 ITO 기판 위에 DLC를 합성하고 기계적 특성과 가시광선 영역 투과도를 조사하였다. RF-PECVD(radio frequency plasma enhanced chemical vapor deposition) 방법에 의해서 $C_2H_2+Ar$ 혼합 가스 비율과 $C_2H_2+N_2$ 혼합 가스 비율을 변화시켜 ITO 기판 위에 DLC 박막을 합성하였다. 공정 압력과 rf-power, 증착시간, 기판온도는 0.2 torr, 40 W, 5 분, $50^{\circ}C$로 고정하고, 공정 가스는 $C_2H_2+Ar$$C_2H_2+N_2$가 200 sccm이 되도록 비율을 변화하였다. $C_2H_2:Ar$$C_2H_2:N_2$의 비율은 180 : 20, 160 : 40, 140 : 60, 120 : 80, 100 : 100이 되도록 가스의 유량을 조절하였다. 투과도는 가시광선(380 ~ 780 nm) 범위에서 측정하였고 두께와 표면조도는 AFM으로 측정하였다. 투과도는 $C_2H_2+Ar$의 Ar 가스 비율이 증가할수록 증가해 140 : 60일 때 최댓값을 나타낸 후 다시 감소하였다. $C_2H_2+N_2$ 투과도는 $N_2$ 가스 비율이 증가할수록 감소하는 경향을 나타내었다. 표면 거칠기는 $C_2H_2+Ar$ 혼합 가스를 사용한 경우의 Ar의 가스 비율이 증가할수록 증가하였다. 그러나 $C_2H_2+N_2$ 혼합 가스를 사용한 경우에는 $N_2$ 가스의 혼합 비율이 증가할수록 감소하였다.

  • PDF

Association among Serum Lipid, Apolipoprotein Levels and Related Factors in Healthy Adults (중.장년층의 혈청 지질 및 아포지단백질의 농도와 관련된 요인 분석)

  • Lee, Hoe-Seon;Kim, Gyeong-Eup;Park, Mi-Young;Youn, Hee-Shang;Choi, Sun-Young;Kim, Sung-Hee
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.18 no.6
    • /
    • pp.949-958
    • /
    • 2008
  • This study was carried out to examine the association of age, nutrient intake, alcohol drinking and smoking on serum lipid and apolipoprotein levels in 100 healthy adults (54 males and 46 females). The serum total cholesterol, low density lipoprotein cholesterol (LDL-C) (p<0.05), apolipoprotein B (Apo B) levels, LDL-C:high density lipoprotein cholesterol (HDL-C) ratio, Apo B:apolipoprotein(Apo A-I) ratio and atherogenic index (AI) (p<0.001) were significantly higher in males than females, but HDL-cholesterol level was significantly lower (p<0.01) in males than females. The plasma ascorbic acid concentration had no difference in both genders. Most of nutrient intakes except Ca, vitamin A and vitamin $B_2$ were higher than RI (Recommended intake) in both males and females. The meal frequency per day was significantly higher (p<0.01) in males than females, while meal speed, the heaviest meal, meal quantity and meal regularity had no significant differences. The rates of drinking and smoking were significantly higher (p<0.01) in males (59.3%, 37.2%) than females (17.3%, 6.9%). The age was positively correlated with triglyceride level in males (p<0.05), and with total cholesterol (p<0.001), LDL-cholesterol (p<0.001), Apo B (p<0.01), LDL-C:HDL-C ratio (p<0.01), Apo B:Apo A-I ratio (p<0.05) and AI (p<0.01) in females. The levels of serum lipid and apolipoprotein were more correlated with protein intake than other macronutrient intakes in males, while those in females were more correlated energy, carbohydrate and lipid intakes than protein intake. The effect of drinking on serum lipid and apolipoprotein levels was bigger in males than females, while the effect of smoking on those was bigger in females than males. The plasma ascorbic acid concentration was positively correlated with HDL-cholesterol (p<0.05), Apo A-I levels (p<0.001), whereas negatively correlated with Apo B:Apo A-I ratio (p<0.05) in males. And that was positively correlated with HDL-cholesterol (p<0.05) in females. These results suggest that moderate macronutrient intake, less alcohol consumption and non-smoking were necessary to maintain healthy lipid profile with aging in adults.

  • PDF

The Effects of Melatonin on Cisplatin-Induced Renal Cortical Cell Injury in Rabbits

  • Kim, Chung-Hui;Han, Jin;Kim, Na-Ri;Park, Ju-Hee;Yang, Young-Churl;Kim, Eui-Yong
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.5 no.3
    • /
    • pp.223-230
    • /
    • 2001
  • Melatonin, a pineal gland hormone, is believed to act as an antioxidant via the stimulation of radical detoxifying enzymes and scavenging of free radicals. In this study, effects of in vitro and in vivo treatments of melatonin on the cisplatin-induced lipid peroxidation, LDH release and plasma creatinine were determined in rabbit renal cortical cells. The level of malondialdehyde (MDA) was assayed as an index of lipid peroxidation and the level of LDH release as an indicator of cellular damage. In in vitro studies, cisplatin increased the levels of MDA and LDH release in a concentration-and time-dependent manner. Melatonin inhibited the cisplatin-induced lipid peroxidation and LDH release in a concentration-dependent manner. The minimal effective concentration of melatonin that significantly reduced the $300\;{\mu}M$ cisplatin-induced lipid peroxidation and LDH release was 1 mM. In in vivo studies, the levels of lipid peroxidation and LDH release in renal cortical cells increased significantly 24 or 48 hours after a single injection of cisplatin (6 mg/kg). When the cisplatin-injected rabbits were pretreated with 10 mg/kg of melatonin, a significant reduction in both lipid peroxidation and LDH release was observed. The plasma creatinine level increased from $0.87{\pm}0.07$ mg/dl in control to $6.33{\pm}0.54$ mg/dl in cisplatin-injected rabbits (P<0.05). Melatonin partially prevented the increase in serum creatinine level $(1.98{\pm}0.11\;mg/dl)$ by cisplatin (P<0.05). In the proximal tubules from cisplatin-treated group, tubular cells had microvilli of variable heights. Necrotic debris was seen in tubular lumens. In most of cells, the mitochondria and lysosomes were increased in frequency. The endocytic vacuoles were not prominent and distribution of the brush border was irregular and shortened. These cisplatin-induced morphological changes were moderate in the melatonin-pretreated group. These results suggest that the toxicity of cisplatin is associated with the generation of reactive oxygen free radicals and that melatonin is a powerful antioxidant, which prevents some of the adverse effects of cisplatin.

  • PDF

Corrosion Behaviors of Dental Implant Alloy after Micro-sized Surface Modification in Electrolytes Containing Mn Ion

  • Kang, Jung-In;Son, Mee-Kyoung;Choe, Han-Cheol
    • Journal of Korean Dental Science
    • /
    • v.11 no.2
    • /
    • pp.71-81
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the corrosion behaviors of dental implant alloy after microsized surface modification in electrolytes containing Mn ion. Materials and Methods: $Mn-TiO_2$ coatings were prepared on the Ti-6Al-4V alloy for dental implants using a plasma electrolytic oxidation (PEO) method carried out in electrolytes containing different concentrations of Mn, namely, 0%, 5%, and 20%. Potentiodynamic method was employed to examine the corrosion behaviors, and the alternatingcurrent (AC) impedance behaviors were examined in 0.9% NaCl solution at $36.5^{\circ}C{\pm}1.0^{\circ}C$ using a potentiostat and an electrochemical impedance spectroscope. The potentiodynamic test was performed with a scanning rate of $1.667mV\;s^{-1}$ from -1,500 to 2,000 mV. A frequency range of $10^{-1}$ to $10^5Hz$ was used for the electrochemical impedance spectroscopy (EIS) measurements. The amplitude of the AC signal was 10 mV, and 5 points per decade were used. The morphology and structure of the samples were examined using field-emission scanning electron microscopy and thin-film X-ray diffraction. The elemental analysis was performed using energy-dispersive X-ray spectroscopy. Result: The PEO-treated surface exhibited an irregular pore shape, and the pore size and number of the pores increased with an increase in the Mn concentration. For the PEO-treated surface, a higher corrosion current density ($I_{corr}$) and a lower corrosion potential ($E_{corr}$) was obtained as compared to that of the bulk surface. However, the current density in the passive regions ($I_{pass}$) was found to be more stable for the PEO-treated surface than that of the bulk surface. As the Mn concentration increased, the capacitance values of the outer porous layer and the barrier layer decreased, and the polarization resistance of the barrier layers increased. In the case of the Mn/Ca-P coatings, the corroded surface was found to be covered with corrosion products. Conclusion: It is confirmed that corrosion resistance and polarization resistance of PEO-treated alloy increased as Mn content increased, and PEO-treated surface showed lower current density in the passive region.

Effect of Oxygen and Diborane Gas Ratio on P-type Amorphous Silicon Oxide films and Its Application to Amorphous Silicon Solar Cells

  • Park, Jin-Joo;Kim, Young-Kuk;Lee, Sun-Wha;Lee, Youn-Jung;Yi, Jun-Sin;Hussain, Shahzada Qamar;Balaji, Nagarajan
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.4
    • /
    • pp.192-195
    • /
    • 2012
  • We reported diborane ($B_2H_6$) doped wide bandgap hydrogenated amorphous silicon oxide (p-type a-SiOx:H) films prepared by using silane ($SiH_4$) hydrogen ($H_2$) and nitrous oxide ($N_2O$) in a radio frequency (RF) plasma enhanced chemical vapor deposition (PECVD) system. We improved the $E_{opt}$ and conductivity of p-type a-SiOx:H films with various $N_2O$ and $B_2H_6$ ratios and applied those films in regards to the a-Si thin film solar cells. For the single layer p-type a-SiOx:H films, we achieved an optical band gap energy ($E_{opt}$) of 1.91 and 1.99 eV, electrical conductivity of approximately $10^{-7}$ S/cm and activation energy ($E_a$) of 0.57 to 0.52 eV with various $N_2O$ and $B_2H_6$ ratios. We applied those films for the a-Si thin film solar cell and the current-voltage characteristics are as given as: $V_{oc}$ = 853 and 842 mV, $J_{sc}$ = 13.87 and 15.13 $mA/cm^2$. FF = 0.645 and 0.656 and ${\eta}$ = 7.54 and 8.36% with $B_2H_6$ ratios of 0.5 and 1% respectively.

Contact block copolymer technique을 이용한 실리콘 나노-필라 구조체 제작방법

  • Kim, Du-San;Kim, Hwa-Seong;Park, Jin-U;Yun, Deok-Hyeon;Yeom, Geun-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.189-189
    • /
    • 2015
  • Plasmonics, sensor, field effect transistors, solar cells 등 다양한 적용분야를 가지는 실리콘 구조체는 제작공정에 의해 전기적 및 광학적 특성이 달라지기 때문에 적합한 나노구조 제작방법이 요구되고 있다. 나노구조체 제작방법으로는 Photo lithography, Extreme ultraviolet lithography (EUV), Nano imprinting lithography (NIL), Block copolymer (BCP) 방식의 방법들이 연구되고 있으며, 특히 BCP는 direct self-assembly 특성을 가지고 있으며 가격적인 면에서도 큰 장점을 가진다. 하지만 BCP를 mask로 사용하여 식각공정을 진행할 경우 BCP가 버티지 못하고 변형되어 mask로서의 역할을 하지 못한다. 이러한 문제를 해결하기 위하여 본 논문에서는 BCP와 질화막을 이용한 double mask 방법을 사용하였다. 기판 위에 BCP를 self-assembly 시키고 mask로 사용하여 hole 부분으로 노출된 기판을 Ion gun을 통해 질화 시킨 후에 BCP를 제거한다. 기판 위에 hole 모양의 질화막 표면은 BCP와 다르게 etching 공정 중 변형되지 않는다. 이러한 질화막 표면을 mask로 사용하여 pillar pattern의 실리콘 나노구조체를 제작하였다. 질화막 mask로 사용되는 template은 PS와 PMMA로 구성된 BCP를 사용하였다. 140kg/mol의 polystyrene과 65kg/mol의 PMMA를 톨루엔으로 용해시키고 실리콘 표면 위에 spin coating으로 도포하였다. Spin coat 후 230도에서 40시간 동안 열처리를 진행하여 40nm의 직경을 가진 PS-b-PMMA self-assembled hole morphology를 형성하였다. 질화막 형성 및 etching을 위한 장비로 low-energy Ion beam system을 사용하였다. Reactive Ion beam은 ICP와 3-grid system으로 구성된 Ion gun으로부터 형성된다. Ion gun에 13.56 MHz의 frequency를 갖는 200W 전력을 인가하였다. Plasma로부터 나오는 Ion은 $2{\Phi}$의 직경의 hole을 가지는 3-grid hole로 추출된다. 10~70 voltage 범위의 전위를 plasma source 바로 아래의 1st gird에 인가하고, 플럭스 조절을 위해 -150V의 전위를 2nd grid에 인가한다. 그리고 3rd grid는 접지를 시켰다. chamber내의 질화 및 식각가스 공급은 2mTorr로 유지시켰다. 그리고 기판의 온도는 냉각칠러를 이용하여 -20도로 냉각을 진행하였다. 이와 같은 공정 결과로 100 nm 이상의 높이를 갖는 40 nm직경의 균일한 Silicon pillar pattern을 형성 할 수 있었다.

  • PDF

A Proposal of study Designs and Methods for Evaluating the Adverse Health Effects of Agent Orange among Korean Vietnam Veterans (고엽제의 건강위해성 평가를 위한 연구설계와 방법 제안)

  • Yi, Sang-Wook;Won, Jong-Uk;Hong, Jae-Seok;Ohrr, Hee-Choul
    • Journal of Preventive Medicine and Public Health
    • /
    • v.34 no.3
    • /
    • pp.228-236
    • /
    • 2001
  • Objectives : To propose a feasible, valid and appropriate study designs and epidemiologic methods for evaluating the adverse health effects of Agent Orange-chemical defoliants used in Vietnam- in Korea. Methods : A literature study was peformed on Agent Orange, herbicides, pesticides and dioxins. The study subjects, study design, exposure assessment and health outcomes assessment were examined in each study. The potential data sources for the study subjects, study design, exposure assessment and health outcomes assessment in Korea were investigated. Results and Conclusion : In earlier Korean studies, research subjects for studying the effects of Agent Orange were identified from the patients or persons who claimed to have Agent Orange-related diseases due to the difficulties in identifying the entire population of Vietnam veterans in Korea. In this study, an attempt was made to identify the total number of Vietnam veterans in Korea. As a result, the addresses of 20,000 Vietnam veterans were obtained. It is proposed that a retrospective cohort design on a sample of the total number of Vietnam veterans is a feasible and appropriate study design. Self report questionnaires and military records were proposed to assess the exposure level. It is believed that measuring the plasma or tissue TCDD should be used only for a validation study assessing the level of exposure. For the health outcomes assessment, it is possible to obtain the mortality, cancer frequency, physical examination, screening and medical insurance record data.

  • PDF