• Title/Summary/Keyword: plasma frequency

Search Result 855, Processing Time 0.04 seconds

Frequent Genetic Defects in the HIV-1 5'LTR/gag Gene in Hemophiliacs Treated with Korean Red Ginseng: Decreased Detection of Genetic Defects by Highly Active Antiretroviral Therapy

  • Cho, Young-Keol;Jung, You-Sun;Sung, Heung-Sup;Joo, Chul-Hyun
    • Journal of Ginseng Research
    • /
    • v.35 no.4
    • /
    • pp.413-420
    • /
    • 2011
  • We investigated whether Korean red ginseng (KRG) and highly active antiretroviral therapy (HAART) affect the frequency of gross deletion in 5'LTR/gag in 20 hemophiliacs. This study is a prospective study in 20 hemophiliacs who were infected with Korean subclade B of HIV-1 from two cash-paid plasma donors in 1990. Over a 13-year period, we obtained 436 amplicons of 5'LTR/gag genes by nested polymerase chain reaction using 147 peripheral blood mononuclear cells. Of the 436 amplicons, 92 (21.1%) showed gross deletion in 5'LTR/gag. Despite of a 2.3-fold higher monthly dose of KRG intake, the frequency of gross deletion in 5'LTR/gag (16.4%) was significantly decreased during HAART compared with 28.1% prior to HAART (p<0.01). Gross deletion in 5'LTR/gag was 10% more detected on KRG-therapy than prior to KRG-therapy (p<0.05). In addition, we also obtained 28 amplicons containing premature stop codon or isoleucine at initiation codon of 254 amplicons sequenced on KRG intake (7.5%) or HAART (13.6%) compared with 0% before KRG intake. These findings indicate that high frequency of gross deletion in 5'LTR/gag and genetic defects prior to HAART are significantly associated with KRG intake and the detection of gross deletion in 5'LTR/gag is decreased by HAART.

mechanism of Equivalent Power Distribution in Parallel Connected ICP for Large Area Processing

  • Lee, Jin-Won;Bae, In-Sik;An, Sang-Hyeok;Jang, Hong-Yeong;Yu, Sin-Jae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.510-510
    • /
    • 2012
  • 반도체, 디스플레이, 태양광 등의 공정에서 사용되는 웨이퍼의 크기가 증가하고, 생산률이 플라즈마의 밀도에 비례한다는 연구 결과가 발표되면서 대면적 고밀도 플라즈마 소스 개발에 대한 연구가 활발히 진행되고 있다. 특히, ECR, ICP, Helicon plasma 등 고밀도 플라즈마 소스에 대한 관심이 높아지고 있다. 이에 따라, 여러 개의 ICP를 결합한 multiple ICP를 이용해 대면적 고밀도 플라즈마 소스 개발을 진행했다. Multiple ICP의 경우 각 ICP 소스에 같은 power (current)를 공급해야만 균일한 플라즈마 방전이 발생되어 균일도를 확보 할 수 있다. Current controller 같은 추가적인 장비를 설치하지 않고, power를 분배하는 transmission line을 coaxial 형태로 설계하고 같은 길이로 병렬 연결함으로써 각각의 ICP소스에서 균일한 플라즈마를 방전시킬 수 있었다. Power generator에서 보는 각 ICP의 total impedance는 각 ICP 소스의 impedance와 coaxial 형태의 transmission line의 characteristic impedance, frequency, 길이의 함수로 구할 수 있고, 이 total impedance가 일정하기 때문에 current가 균등하게 분배되어 각 ICP소스에 균등한 power 분배가 가능한 것이다. 실질적으로 ICP 소스의 impedance는 플라즈마 방전 유무에 따라 변화하기 때문에 일정하게 유지하는 것은 어렵다. Transmission line의 characteristic을 사용함으로써 ICP의 impedance의 변화에 상관없이 Total impedance를 일정하게 유지시킴으로써 균등한 power 분배가 가능하다는 것을 연구했다. Frequency는 13,56MHz, characteristic impedance를 $50{\Omega}$ (coaxial cable)으로 고정하고, ICP 소스의 플라즈마 방전 유무/antenna turn/소스 위치에 따른 total impedance를 transmission line의 길이에 따라 측정하고, 이를 이론값, 그래프와 비교하였다. 특정 length에서 플라즈마 방전 유무(ICP의 impedance 변화)와 상관없이 비교적 일정한 total impedance를 유지하는 것을 확인 했다. 이것은 특정 길이를 갖는 coaxial형태의 transmission line를 연결하면, total impedance는 플라즈마 방전 유무로 발생하는 ICP의 impedance 변화와 상관없이 일정하게 유지되어 각 ICP소스에 균등한 파워 분배가 가능하다는 것을 보여준 결과이다. 이것을 토대로 frequency에 따라(또는 characteristic impedance에 따라) 균등한 파워 분배가 가능한 coaxial 형태 transmission line의 특정 길이를 구할 수 있고, 대면적 소스에서 균등한 파워 분배를 위한 병렬연결에 적용할 수 있을 것이다.

  • PDF

Haplotype Analysis and Single Nucleotide Polymorphism Frequency of Organic Cation Transporter Gene (OCT1 and 2) in Korean Subjects

  • Kim, Se-Mi;Lee, Sang-No;Yoon, Hwa;Kang, Hyun-Ah;Cho, Hea-Young;Lee, Il-Kwon;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.5
    • /
    • pp.345-351
    • /
    • 2009
  • Organic cation transporters (OCTs) are important for absorption, elimination of many endogenous small organic cations as well as a wide array of drugs and environmental toxins. This gene is located in a cluster on chromosome 6 and OCTs are in major organs such as intestine, liver, kidney, brain and placenta. Therefore, expression levels and function of OCTs directly affect plasma levels and intracellular concentrations of drugs and thereby determine therapeutic response. The aim of this study was to investigate the frequency of the SNPs on OCT1 (C181T and C1022T) and OCT2 (G808T) to analyze haplotype frequency in healthy Korean population. Human subjects have been genotyped for OCT1 (C181T for 195 subjects and C1022T for 825 subjects), using polymerase chain reaction-based diagnostic tests (RFLP). And for OCT2 (G808T), a total of 861 subjects have been genotyped, using pyrosequencing method. Haplotype was statistically inferred using an algorithm based on the expectation-maximization (EM). OCT1 C181T genotyping showed 100% homozygous wild-type (C/C). OCT1 C1022T genotyping showed wild-type (C/C), heterozygous (C/T) and homozygous mutant-type (T/T) and each accounted for 72.1, 24.5 and 3.4%, respectively. OCT2 G808T genotyping results also showed homozygous wild-type (G/G), heterozygous (G/T) and homozygous mutant-type (T/T) and each took 81.8, 17.9 and 0.3%, respectively. Based on these genotype data, haplotype analysis between OCT1 C181T and OCT1 C1022T has proceeded. The result has revealed that linkage disequilibrium between alleles is not obvious (P=0.0122).

Tribological properties of DLC films on polymers

  • Hashizume, T.;Miyake, S.;Watanabe, S.;Sato, M.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.175-176
    • /
    • 2002
  • Our study is to search for tribological properties of diamond-like carbon (DLC) films as known as anti- wear hard thin film on various polymers. This report deals with the deposition of DLC films on various polymer substrates in vacuum by magnetron radio frequency (RF) sputtering method with using argon plasma and graphite, titanium target. The properties of friction and wear are measured using a ball-on-disk wear -testing machine. The properties of friction and wear have been remarkably improved by DLC coating. Moreover the composition of DLC films has been analyzed by using auger electron spectroscopy(AES). The wear rate of titanium-containing DLC film is lower than that of no-metal-containing DLC film.

  • PDF

Fabrication of High Break-down Voltage MIM Capacitors for IPD Applications

  • Wang, Cong;Kim, Nam-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.241-241
    • /
    • 2009
  • For the Radio Frequency Integrated Passive Device (RFIPD) application, we have successfully developed and characterized high break-down voltage metal-insulator-metal (MIM) capacitors with 2,000 ${\AA}$ plasma-enhanced chemical vapor deposition (PECVD) silicon nitride which deposited with $SiH_4/NH_3$ gas mixing rate, working pressure, and RF power of PECVD at $250^{\circ}C$ chamber temperature. At the PECVD process condition of gas mixing rate (0.957), working pressure (0.9 Torr), and RF power (60 W), the AFM RMS value of about 2,000 ${\AA}$ silicon nitride on the bottom metal was the lowest of 0.862 nm and break-down electric field was the highest of about 8.0 MV/cm with the capacitance density of 326.5 $pF/mm^2$.

  • PDF

The fluoride application using low frequency non-thermal plasma jet

  • Lee, Hyeon-Yeong;Dang, Cheon-U;Kim, Yeong-Min;Kim, Dong-Hyeon;Lee, Ho-Jun;Lee, Hae-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.228.1-228.1
    • /
    • 2016
  • 기존 산업에서 많이 쓰여져오고 있는 저압 플라즈마에 비해 여러가지 장점을 지닌 대기압 플라즈마는 수년 전부터 많은 연구가 되어 왔으며 폭넓은 응용분야에 있어서 활발히 이용되고 있고, 특히 온도가 거의 상온과 비슷하다는 장점으로 대기압 저온 플라즈마는 바이오메디컬 분야에서 활발하게 응용되어지고 있다. 본 연구에서는 대기압 저온 플라즈마 젯 장치를 사용하여 치아 표면에 불소를 도포하고 법랑질 표면의 불소 원소를 검출함으로써 플라즈마가 치아표면 불소도포에 있어서 어떠한 효과가 있는지 정량적으로 비교분석하였다. 또한 대기압 플라즈마 젯 장치의 방전개시전압과 가스유량에 따른 플라즈마젯 길이의 변화 및 OES(Optical Emission Spectroscopy) 장치를 사용하여 플라즈마에 대한 광학적 진단을 진행하였다. 치아표면에서 검출된 불소량은 플라즈마를 사용했을때가 그렇지 않을때에 비해 더 높게 관찰 되었다.

  • PDF

Design of a Power System with Variable Voltage and Frequency for a Plasma Discharger (플라즈마 방전장치 구동을 위한 전압 및 주파수 가변 전원장치 설계)

  • Jou, Sung-Tak;Jeong, Hae-Gwang;Lee, Kyo-Beum
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.386-387
    • /
    • 2011
  • 본 논문은 플라즈마 방전장치 구동을 위한 가변 전압/주파수 전원장치를 제안한다. 제안하는 전원장치는 가변전압을 위한 벅-부스트 컨버터와 주파수 변환을 위한 푸쉬-풀 인버터로 구성된다. 제안하는 전원장치의 벅-부스트 컨버터는 계통전류 고조파 저감과 DC링크 캐패시터 최소화를 위하여 PFC(Power Factor Collection)기법을 적용한다. 그리고 푸쉬-풀 인버터는 출력 변압기의 자기포화를 막기 위해 전류제한기법을 추가한다. 또한 불분명한 부하와 출력 트랜스의 공진 상황에서 전압 안정화를 위해 출력전압을 피드백하여 제어한다. 본 논문은 1[kW]급 플라즈마 전원장치를 통하여 제안하는 토폴로지와 제어방법의 타당성을 검증한다.

  • PDF

A study on high frequency impulse plasma power supply for improving deposition rate (증착율 개선을 위한 고주파 임펄스 플라즈마 전원장치에 대한 연구)

  • Ban, Jung-Hyun;Kim, Dong-Sung;Han, Hee-Min;Seo, Kwang-Duk;Kim, Joohn-Sheok
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.384-385
    • /
    • 2011
  • 산업기술이 고도화됨에 따라 다양한 계열의 박막이 필요하게 되었고 고밀도의 플라즈마를 공급하고 안정된 공정의 진행을 위해 순시적인 플라즈마 제어가 가능한 임펄스 전원장치에 대한 연구가 활발히 진행되고 있다. 플라즈마를 이용한 박막증착에서 요구되어지는 고품질의 박막특성을 구현하기 위해 다양한 공정기술이 개발되어 사용되고 있으며, 여기에는 박막을 구현하기 위한 증착 시스템 개발과 공정기술, 그리고 플라즈마를 형성, 유지시키는 고성능의 전원장치가 필요하다. 최근 박막증착 공정이 다양화되고 박막의 고품질화와 고속화 추세에 대응하기 위해서 고밀도의 플라즈마 제어가 가능한 고출력 임펄스 전원 개발이 요구된다. 또한, 에너지 밀도 증가를 위해 고속 임펄스 전원 장치의 필요성이 제기되고 있다. 본 연구에서는 앞서 연구되어진 저압회로를 부가한 임펄스 전원장치[1]를 수정, 보완한 후속연구로써, 증착율 개선을 위한 고주파 임펄스 플라즈마 전원 장치를 제안한다.

  • PDF

RF (Radio-Frequency) Thermal Plasma Synthesis of Ni-Based Nano Powders

  • Seo, Jun-Ho;Nam, Jun-Seok;Lee, Mi-Yeon;Kim, Jeong-Su
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.138-138
    • /
    • 2013
  • Ni-CeO2 및 Ni-MgO와 같이 Ni이 포함된 나노복합물질을 고주파 유도결합 플라즈마를 이용하여 합성하였다. 이를 위해, 먼저, 1~100 ${\mu}m$ 크기의 가상 Ni 입자와 고융점 세라믹 입자가 플라즈마 유동 내에서 겪는 열전달 과정을 수치해석을 통해 묘사하였다. 묘사 결과로부터, 완전 기화한 Ni 증기가, 채 기화하지 못하고 고체 형태로 남은 세라믹 입자 위에서 균일하게 응축된 형태를 갖는 Ni-세라믹 나노입자 합성을 예측하고, 실제 합성 실험을 25 kW 급 고주파 유도결합 플라즈마에 0.1~10 ${\mu}m$ 크기의 Ni, CeO2 및 MgO 분말을 주입하여 수행하였다. 마지막으로, 실험을 통해 합성된 Ni 계 복합나노물질에 대해, FE-SEM 및 TEM 사진 분석과 EDS 및 ICP-AES 성분 분석을 진행하고, 수치해석을 통해 예측된 결과와 비교 검토하였다.

  • PDF

Two-Dimensional Simulation of Hg Flat Fluorescent Lamps for an LCD Backlight unit (액정디스플레이 후판광원용 평판형 수은 형광램프의 2차원 시뮬레이션 연구)

  • Yoon, Hyun-Jin;Lee, Hae-June
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.7
    • /
    • pp.1275-1281
    • /
    • 2007
  • The discharge phenomena in a flat fluorescent lamp for the backlight unit of liquid crystal displays are simulated by sung a two-dimensional fluid model. The numerical methods for the calculation of plasma dynamics and the radiation transport are introduced for the discharge simulation and for the transmission of the vacuum ultraviolet lights. The simulation results are presented to compare the luminance and the luminance efficacy with the variation of gas pressure, gas mixture ratio, driving voltage, and frequency.