• 제목/요약/키워드: plasma flow

검색결과 1,180건 처리시간 0.025초

저온 증착된 불소도핑 주석 산화 박막의 광학적·전기적 특성 (Optical and Electrical Properties of Fluorine-Doped Tin Oxide Prepared by Chemical Vapor Deposition at Low Temperature)

  • 박지훈;전법주
    • 한국재료학회지
    • /
    • 제23권9호
    • /
    • pp.517-524
    • /
    • 2013
  • The electrical and optical properties of fluorine-doped tin oxide films grown on polyethylene terephthalate film with a hardness of 3 using electron cyclotron resonance plasma with linear microwave of 2.45 GHz of high ionization energy were investigated. Fluorine-doped tin oxide films with a magnetic field of 875 Gauss and the highest resistance uniformity were obtained. In particular, the magnetic field could be controlled by varying the distribution in electron cyclotron deposition positions. The films were deposited at various gas flow rates of hydrogen and carrier gas of an organometallic source. The surface morphology, electrical resistivity, transmittance, and color in the visible range of the deposited film were examined using SEM, a four-point probe instrument, and a spectrophotometer. The electromagnetic field for electron cyclotron resonance condition was uniformly formed in at a position 16 cm from the center along the Z-axis. The plasma spatial distribution of magnetic current on the roll substrate surface in the film was considerably affected by the electron cyclotron systems. The relative resistance uniformity of electrical properties was obtained in film prepared with a magnetic field in the current range of 180~200A. SEM images showing the surface morphologies of a film deposited on PET with a width of 50 cm revealed that the grains were uniformly distributed with sizes in the range of 2~7 nm. In our experimental range, the electrical resistivity of film was able to observe from $1.0{\times}10^{-2}$ to $1.0{\times}10^{-1}{\Omega}cm$ where optical transmittance at 550 nm was 87~89 %. These properties were depended on the flow rate of the gas, hydrogen and carrier gas of the organometallic source, respectively.

신통축어탕(身痛逐瘀湯)의 항염(抗炎), 진통(鎭痛) 및 항열전효과(抗血栓效果)에 관(關)한 연구(硏究) (Study on the Anti-inflammatory, Analgesic and Anti-thrombotic Effects of Shintongchugeotang in the Experimental Animals)

  • 유지용;이기상;문병순
    • 대한한방내과학회지
    • /
    • 제18권1호
    • /
    • pp.69-85
    • /
    • 1997
  • This study was designed to elucidate the anti-inflammatory, cardiovascular, anti-thrombotic and analgesic effects of Shintongchugeotang. The anti-inflammatory effect was measured by the method of carragenin induced edema, protein leakage test using CMC-pouch, and the analgesic effect was measured by the acetic acid method and hot plate method, and the effect of Shintongchugeotang on the cardiovascular system was observed by the change of flow rate of Ringer solution in the vascular system in the ear of rabbit, and the contraction and dilatation of rat tail artery. Death rate, platelet aggregation, plasma coagulation activity was observed for the measurement of the anti-coagurative effect of Shintongchugeotang. The result was as follows : 1. After the administration of Shintongchugeotang extract, Carragenin induced edema and CMC-pouch protein leakage were significantly decreased. 2. The slight analgesic effect of Shintongchugeotang extract was confirmed by the observation of writhing syndrome, paw licking time, and escape time. 3. The drug increased the auricular blood flow in rabbit. 4. The drug relaxed the artery contraction by pretreated norepinephrine in rat. 5. The drug inhibited the death rate of mouse which was led to thromboembolism by serotonin and collagen. 6. The drug inhibited the platelet aggregation in rat. 7. The drug prolonged the prothrombin time and activated partial thromboplastin time on the test of plasma coagulation factor activity in rat, but was not valuable.

  • PDF

A Hyperactive Neutrophil Phenotype in Aggressive Periodontitis

  • Kim, Kap-Yul;Kim, Min-Kyung;Choi, Yun-Sik;Kim, Yong-Cheol;Jo, Ah-Ram;Rhyu, In-Chul;Choi, Young-Nim
    • International Journal of Oral Biology
    • /
    • 제37권2호
    • /
    • pp.69-75
    • /
    • 2012
  • Although neutrophils function in both defense and tissue destruction, their defensive roles have rarely been studied in association with periodontitis. We hypothesized that peripheral neutrophils are pre-activated in vivo in periodontitis and that hyperactive neutrophils would show enhanced phagocytic ability as well as an increased production of reactive oxygen species (ROS). Peripheral blood neutrophils from patients with aggressive periodontitis and age/gender-matched healthy subjects (10 pairs) were isolated. The levels of CD11b and CD64 expression on the neutrophils and the level of plasma endotoxin were determined by flow cytometry and a limulus amebocyte lysate test, respectively. In addition, neutrophils were subjected to a flow cytometric phagocytosis assay and luminol-enhanced chemiluminescence for non-opsonized Fusobacterium nucleatum in parallel. The neutrophilsfrom most patients expressed increased levels of both CD11b and CD64. In addition, the plasma from these patients tended to contain a higher level of endotoxin than the healthy controls. In contrast, no differences were found between the two groups with regard to phagocytosis or ROS generation by F. nucleatum. The ability to phagocytose F. nucleatum was found to positively correlate with the ability to produce ROS. In conclusion, peripheral neutrophils from patients with aggressive periodontitis are hyperactive but not hyperreactive to F. nucleatum.

삼비탕(三痺湯)의 항염(抗炎), 항응고(抗凝固) 및 진통효과(鎭痛效果)에 대(對)한 연구(硏究) (Study on the Antiinflammatory, Anticoagulative and Analgesic effects of Sambitang in the experimental animal model)

  • 류준기;이영구;문병순
    • 대한한방내과학회지
    • /
    • 제19권2호
    • /
    • pp.88-106
    • /
    • 1998
  • This study was designed to elucidate the antiinflammatory, cardiovascular, antithrombotic, and analgesic effect of Sambitang. The antiinflammatory effects was measured by the method of carrageenin induced edema, protein leakage test using CMC-pouch, and the effect of Sambitang on the cardiovascular system was observed by the change of flow rate of Ringer solution in the vascular system in the ear of rabbit, and the contraction and dilatation of rat tail artery. Death rate, platelet aggregation, plasma coagulation activity was observed for the measurement of the anticoagurative effect of Sambitang, and the analgesic effect was measured by the acetic acid method and hot plate method. The result was as follows: 1. Sambitang administration, edema and protein leakage was significantly decreased. 2. The drug increased the auricular blood flow in rabbit. 3. The drug relaxed the artery contraction by pretreated norepinephrine in rat. 4. The drug inhibited the death rate of mouse which was led to thromboembo- lism by serotonin and collagen. 5. The drug inhibited the platelet aggregation in rat. 6. The drug prolonged the prothrombin time and activated partial thromboplastin time on the test of plasma coagulation factor activity in rat, but was not valuable. 7. The slight anagesic effect of Sambitang extract was confirmed by the observation of writhing syndrome, paw licking time, and escape time.

  • PDF

급성 일측 수뇨관 폐쇄후 상대신의 $Li^+$처리에 관한 연구 (Effect of Acute Unilateral Ureteral Obstruction on Handling of $Li^+$ by Contralateral Kidney in Rabbits)

  • 성호경;엄융의
    • The Korean Journal of Physiology
    • /
    • 제16권2호
    • /
    • pp.165-175
    • /
    • 1982
  • Changes in handling of $Li^+$ by contralateral kidney during acute $Li^+$ loading were investigated immediately after unilateral ureteral obstruction. Carotid artery, jugular vein, renal vein and ureter of experimental animal were catheterized and renal venous flow was shunted to .external jugular vein. In experimental group right ureter was ligated. One to two hours after operation a single shot of LiCl solution (2 mEq/kg) was intravenously injected and then .arterial, renal venous blood and urine samples were taken sequentially for 1 to $1{\frac{1}{2}}$ hours. Urine volume, plasma and urinary concentrations of $Li^+$, $Na^+$ and $K^+$ were measured and urinary excretion of them were calculated. Results obtained were as follows: 1) In experimental group urine volume, urinary excretion of $Na^+$, and $K^+$ by contralateral kidney after unilateral ureteral obstruction were slightly larger than mean value of both kidney in control group. 2) During acute $Li^+$ loading contralateral kidney in experimental group showed limited $K^+$ excretion, but urinary flow and $Na^+$ excretion were comparable to mean value of both kidney in control group. 3) Urinary osmolar concentration in experimental group was much lower than that in control group, and it was maintained at low level even after Li loading. 4) In experimental group plasma$Li^+$ concentration decreased more slowly than in control group after a single shot of LiCl solution. 5) Urinary excretion of $Li^+$ in experimental group was markedly decreased, even lesseer than mean of both kidney in control group. 6) From the above results it was concluded that immediately after unilateral ureteral obstruction contralateral kidney showed normal water and $Na^+$ diuretic response to Li load but urinay $Li^+$ excretion was decreased and reclaimed $Li^+$ to systemic circulation.

  • PDF

Mechanism Study of Flowable Oxide Process for Sur-100nm Shallow Trench Isolation

  • Kim, Dae-Kyoung;Jang, Hae-Gyu;Lee, Hun;In, Ki-Chul;Choi, Doo-Hwan;Chae, Hee-Yeop
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.68-68
    • /
    • 2011
  • As feature size is smaller, new technology are needed in semiconductor factory such as gap-fill technology for sub 100nm, development of ALD equipment for Cu barrier/seed, oxide trench etcher technology for 25 nm and beyond, development of high throughput Cu CMP equipment for 30nm and development of poly etcher for 25 nm and so on. We are focus on gap-fill technology for sub-30nm. There are many problems, which are leaning, over-hang, void, micro-pore, delaminate, thickness limitation, squeeze-in, squeeze-out and thinning phenomenon in sub-30 nm gap fill. New gap-fill processes, which are viscous oxide-SOD (spin on dielectric), O3-TEOS, NF3 Based HDP and Flowable oxide have been attempting to overcome these problems. Some groups investigated SOD process. Because gap-fill performance of SOD is best and process parameter is simple. Nevertheless these advantages, SOD processes have some problems. First, material cost is high. Second, density of SOD is too low. Therefore annealing and curing process certainly necessary to get hard density film. On the other hand, film density by Flowable oxide process is higher than film density by SOD process. Therefore, we are focus on Flowable oxide. In this work, dielectric film were deposited by PECVD with TSA(Trisilylamine - N(SiH3)3) and NH3. To get flow-ability, the effect of plasma treatment was investigated as function of O2 plasma power. QMS (quadruple mass spectrometry) and FTIR was used to analysis mechanism. Gap-filling performance and flow ability was confirmed by various patterns.

  • PDF

미세 유체 기반의 형광 다중 암 진단 센서 플랫폼 설계 (Design of Fluorescence Multi-cancer Diagnostic Sensor Platform based on Microfluidics)

  • 이병권;칼리크 아민;정명영
    • 마이크로전자및패키징학회지
    • /
    • 제29권4호
    • /
    • pp.55-61
    • /
    • 2022
  • 다중 암의 동시 진단 기술에 대한 관심이 전 세계적으로 증가하는 추세이며, 진단 난이도를 낮추기 위해 혈액과 같은 미량의 바이오 유체를 이용하여 질병을 진단하는 미세 유체 소자 기반의 액체 생검 기술이 연구되고 있다. 바이오 유체를 이용하여 형광 영상 등을 통해 분석물질의 농도를 측정하는 광학적 바이오 센싱에 있어 민감도를 향상시키기 위한 기술개발이 필요하다. 본 논문에서는 모세관력에 의한 자가구동 기반의 마이크로 채널의 기하학적 구조와 미세 유체 현상만으로 수동적 자기 혈장 분리 기술과 유체 혼합을 통한 분자 인식 활성화 기능을 구현하는 형광 다중 암 진단 센서 플랫폼 구조를 제안하고 설계하였다. 설계된 센서의 혈장 분리부의 성능에 영향을 미치는 파라미터를 확인하기 위해 채널의 수력학적 직경과 종횡비, 유체의 점도를 변수로 설정하여 딘 와류 형성 여부를 시뮬레이션을 통해 확인하였고 최적의 센서 플랫폼 구조를 제시하였다.

박동류 및 비박동류에 의한 체외순환의 비교 (Comparative Studies of Pulsatile and Nonpulsatile Blood Flow during Cardiopulmonary Bypass)

  • 선경;백광제;김요한;임창영;김광택;김학제;김형묵
    • Journal of Chest Surgery
    • /
    • 제18권2호
    • /
    • pp.182-192
    • /
    • 1985
  • [here are so many reports that pulsatile blood flow provides physiologic organ perfusions during cardiopulmonary bypass. So, we compared the recent 30 cases undergoing cardiac surgery by Cobe-Stckert pulsatile roller pump with another 30 cases by Polystan nonpulsatile roller pump. Pulsatile flow was applied during aortic-cross clamping period when synchronized to internal EKG simulator, and perfusion mode was changed to continuous nonpulsatile flow after declamping of aorta. Age, sex, weight, and disease entities were comparable and operative techniques were similar between two groups. 1. There were no differences in average ACC time, ECC time, and Operation time. 2. Postoperative artificial respiration time was 6hrs 30mins in nonpulsatile group and 4hrs 48mins in pulsatile group, and detubation time after ventilator weaning was 2hrs 44mins in nonpulsatile group and 1hrs 43mins in pulsatile group. 3. Average pulse pressure was 8mmHg in nonpulsatile group and 55mmHg in pulsatile group, and a mean arterial pressure was 66.0mmHg in nonpulsatile group and 60.7mmHg in pulsatile group. 4. Mean urine-output during ACC;ECC period was 9.717.3;9.913.2ml/kg/hr in nonpulsatile group and 14.215.0;15.817.5 in pulsatile group [p<0, 05], and thereafter progressive decrease of differences in urine output between two groups until POD 2, and lesser amounts of diuretics was needed in pulsatile group during same postoperative period. Serum BUN/Cr level showed no specific difference and urine concentration power was well preserved in both groups. 5. Plasma proteins and other Enzymes showed no differences between two groups, but serum GOT/GPT level was higher in nonpulsatile group till POD 2. 6. Serum Electrolytes showed no differences between two groups. 7. WBC, RBC, Platelet counts, Hgb and Hct were not different and Coagulogram was well preserved in both groups. 8. Plasma free Hgb level was 7.09mg% in pulsatile group compared with 3.48mg% in pulsatile group on POD 1 but was normalized on POD 2. Gross hemoglobinuria after ECC was noted in 6 cases [20%] of pulsatile group and 4 cases [13%] of nonpulsatile group. 9. In both groups, most patients were included in NYHA class III to IV [28 cases;93% in nonpulsatile group, 22 cases;73% in pulsatile group] preoperatively, and well improved to class I to 11[22 cases; 73% in nonpulsatile group, 30 cases; 100% in pulsatile group] postoperatively. There were 7 operative mortalities in nonpulsatile group only, which were 5 cases of TOF with hepatic failure, 1 case of multiple VSDs with low out-put syndrome, and 1 case of mitral valvular heart disease with cardiomyopathy. We concluded that the new, commercially available Cobe-Stckert pulsatile roller pump device was safe, simple, and reliable.

  • PDF

다양한 구강안면통증환자의 혈장 및 타액에서의 신경성장인자와 감각성 신경펩티드 농도에 관한 연구 (Nerve Growth Factor and Sensory Neuropeptide Levels in Plasma and Saliva of Various Orofacial Pain Patients)

  • 장민욱;정성창;정진우
    • Journal of Oral Medicine and Pain
    • /
    • 제34권4호
    • /
    • pp.387-395
    • /
    • 2009
  • 신경섬유 말단에서의 유해자극 인지과정에는 신경성장인자 (nerve growth factor [NGF])와 감각성 신경펩티드가 관여하고, 또한 이들은 중추신경계에도 광범위하게 분포되어 있다. 본 연구는 인체 혈액과 타액에서 NGF와 감각성 신경펩티드(substance P [SP], calcitonin gene-related peptide [CGRP])의 농도를 조사하여 다양한 구강안면통증 증상들과의 관계를 알아보고자 시행되었다. 67명의 구강안면통증 환자 (관절 통증, 치아 혹은 치주 통증, 점막 통증)와 36명의 건강한 성인에서 혈장과 안정시 전타액을 채취하여 효소면역분석법 (enzyme immunoassay)을 이용하여 NGF, SP, CGRP의 농도를 측정하였다. 만성통증척도 (Graded Chronic Pain Scale) 설문지를 이용하여 각 피실험자들의 통증강도를 조사하였으며 안정시 전타액의 타액분비율 또한 측정하였다. 관절 통증 환자군은 치아 통증 환자군, 점막 통증 환자군, 대조군 각각에 비하여 유의하게 높은 혈장 내 NGF 농도를 나타내었다. 치아 통증 환자군의 혈장 내 NGF 농도는 대조군에 비하여 유의하게 높았다. 치아 통증 환자군의 타액 내 SP 농도와 점막 통증 환자군의 타액 내 CGRP 농도 또한 대조군에 비하여 유의하게 높았다. 관절 통증 환자군의 혈장 및 타액 내 SP 농도는 통증 강도와 유의한 상관관계를 보였다. 치아 통증 환자군과 점막 통증 환자군에서, 혈장 내 SP 농도, 타액 내 SP 농도, 타액 내 CGRP 농도는 연령에 따라 증가하였다. 혈장과 타액에서의 신경성장인자와 신경펩티드 검사는 다양한 구강안면통증의 특성과 예후를 평가하는데 도움을 줄 수 있으리라 생각된다.

Indium Tin Oxide(ITO) Thin Film Deposition on Polyethylene Terephthalate(PET) Using Ion Beam Assisted Deposition(IBAD)

  • Bae, J.W.;Kim, H.J.;Kim, J.S.;Lee, Y.H.;Lee, N.E.;Yeom, G.Y.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2000년도 제1회 학술대회 논문집
    • /
    • pp.81-83
    • /
    • 2000
  • Tin-doped indium oxide(ITO) thin films were deposited on polyethylene terephthalate(PET) at room temperature by oxygen ion beam assisted evaporator system and the effects of oxygen gas flow rate on the properties of room temperature ITO thin films were investigated. Plasma characteristics of the ion gun such as oxygen ions and atomic oxygen radicals as a function of oxygen flow rate were investigated using optical emission spectroscopy(OES). Faraday cup also used to measure oxygen ion density. The increase of oxygen flow rate to the ion gun generally increase the optical transmittance of the deposited ITO up to 6sccm of $O_2$ and the further increase of oxygen flow rate appears to saturate the optical transmittance. In the case of electrical property, the resistivity showed a minimum at 6 sccm of $O_2$ with the increase of oxygen flow rate. Therefore, the improved ITO properties at 6 sccm of $O_2$ appear to be more related to the incorporation of low energy oxygen radicals to deposited ITO film rather than the irradiation of high energy oxygen ions to the substrate. At an optimal deposition condition, ITO thin films deposited on PET substrates showed the resistivity of $6.6{\times}10^{-4}$ ${\Omega}$ cm and optical transmittance of above 90%.

  • PDF