• 제목/요약/키워드: plasma column

검색결과 236건 처리시간 0.032초

Exploring the Diffuse X-ray Emission of Supernova Remnant Kesteven 69 with XMM-Newton

  • Seo, Kyoung-Ae;Hui, Chung Yue
    • Journal of Astronomy and Space Sciences
    • /
    • 제30권2호
    • /
    • pp.87-90
    • /
    • 2013
  • We have investigated the X-ray emission from the shock-heated plasma of the Galactic supernova remnant Kesteven 69 with XMM-Newton. Assuming the plasma is at collisional ionization equilibrium, a plasma temperature and a column absorption are found to be kT ~ 0.62 keV and $N_H{\sim}2.85{\times}10^{22}\;cm^{-2}$ respectively by imaging spectroscopy. Together with the deduced emission measure, we place constraints on its Sedov parameters.

헬리콘 플라즈마원의 특성 (Characterization of a Helicon Plasma Source)

  • 현준원;노승정;김경례;김창연;김현후
    • 한국표면공학회지
    • /
    • 제32권6호
    • /
    • pp.658-664
    • /
    • 1999
  • Helicon sources are attractive for plasma processing because they provide high plasma density in low magnetic fields. Helicon waves were excited by a Nagoya type III antenna in a magnetized plasma column. Plasma parameters were measured with a double probe, and the structure and adsorption of the helicon wave fields were determined with the probes. Argon is fed through a MFC (mass flow controller) for operation pressure of 10~110 mtorr. A 13.56 MHz r.f. power of 50~450 W is induced through the antenna. The plasma density and electron temperature are measured as functions of external magnetic field, r.f. power and pressure. The plasma density as functions of r.f. power and magnetic field at a constant pressure increased linearly, and the electron temperature did not change largely with various operation parameters and the value was around 5~7 eV.

  • PDF

후 컬럼 동위원소 희석법을 적용한 HPLC-ICP/MS에서의 정량분석에서 내부 표준물을 이용한 정확도와 정밀도의 개선연구 (Study of improving precision and accuracy by using an internal standard in post column isotope dilution method for HPLC-ICP/MS)

  • 주민규;박명순;박용남
    • 분석과학
    • /
    • 제27권3호
    • /
    • pp.140-146
    • /
    • 2014
  • 후 컬럼 동위원소 희석법(PCID, post column isotope dilution)을 HPLC-ICP/MS (high performance liquid chromatography-inductively coupled plasma/mass spectrometry)에 적용한 정량법에서 내부 표준물을 동시에 사용하여 정확도와 정밀도를 개선하였다. 전통적인 여러 정량법과 후 컬럼 동위원소 희석법을 비교하여 볼 때에 PCID의 경우에 컬럼내에서 발생하는 오차가 가장 큰 요인으로 작용하였음을 알 수 있었다. PCID에서 내부 표준물을 사용하여 컬럼내에서의 손실에 대한 오차를 효과적으로 보정하고 정확도와 정밀도를 개선할 수 있었다. 셀레늄 화학종인 SeMet을 시료로 사용하고 내부 표준물로 MeSecys 또는 $Se^{4+}$를 이용한 결과, 사용하지 않은 경우와 비교하면 상대오차는 각 각 31%와 13%에서 모두 1% 대로 낮아져 정확도가 크게 개선되었으며, 상대 표준편차는 5.1%와 6.9%에서 각각 1.5%와 0.2%로 정밀도 또한 크게 개선되었다. PCID에서 내부 표준물을 사용하였을 때의 정량분석법의 장점을 다른 분석법과 비교 토의하였다.

Determining plasma boundary in Alvand-U tokamak

  • Yahya Sadeghi
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3485-3492
    • /
    • 2023
  • One of the major topic of tokamak research is the determination of the magnetic profile due to magnetic coil fields and plasma current by mean of data from magnetic probes. The most practical approach is to use the current filament method, which models the plasma column with multiple current carrying filaments and the total current of these filaments is equal to the plasma current. Determining the plasma boundary in Alvand-U tokamak is the main purpose of this paper. In order to determine the magnetic field profile and plasma boundary, information concerning the magnetic coils, their position, and current is required in the computing code. Then, the plasma shape is determined and finally the plasma boundary is extracted by the code. In the conducted research, we discuss how to determine the plasma boundary and the performance of the computing code for extraction of the plasma boundary. The developed algorithm shows to be effective by running it in the regular pc machine with characteristics of Intel (R) core (TM) i3-10100 CPU @3.60 GHz and 8.00 GB of RAM. Finally, we present results of a test run for computing code using a typical experimental pulse.

대기압 플라즈마 제트의 기체 유량에 대한 방전 특성 (Characteristics of Plasma Discharge according to the Gas-flow Rate in the Atmospheric Plasma Jets)

  • 이원영;김동준;김윤중;한국희;유홍근;김현철;진세환;구제환;김도영;조광섭
    • 한국진공학회지
    • /
    • 제22권3호
    • /
    • pp.111-118
    • /
    • 2013
  • 대기압 플라즈마 제트 장치의 유량 변화에 대한 플라즈마 방전 특성을 실험적으로 조사하고 이를 유체역학적으로 해석하였다. 유리관에 주입되는 아르곤 기체의 유량 변화에 대한 레이놀즈 수(Re)로 결정되는 기체 흐름의 형태 변화와 베르누이 정리에 의한 압력 변화가 플라즈마 발생에 영향을 준다. 유리관 내부에 발생하는 플라즈마의 길이 변화의 실험을 통하여, 아르곤 기체에 대한 레이놀즈 수가 Re<2,000이면 층류이고, Re>4,000이면 난류가 형성된다. 이는 일반 유체에서 알려진 결과와 일치한다. 층류에서 유량의 증가로 플라즈마의 길이가 증가한다. 층류와 난류의 전환 영역에서 플라즈마의 길이는 줄어든다. 난류 영역에서는 방전 기체의 흐름이 불규칙함으로서 방전 경로가 흐트러져 플라즈마 칼럼의 길이가 매우 짧아지고 급기야 플라즈마가 소멸된다. 층류에서 주입 유량의 증가로 유리관 내의 유속이 증가하면, 베르누이 정리에 의하여 유리관 내부의 압력이 낮아진다. 관내의 압력이 낮아지면, 파센 법칙에 의하여 관내의 전기장의 세기가 증가하여 방전 전압이 낮아진다. 따라서 주입 유량이 증가하면, 동일한 구동 전압에서 유리관에 발생하는 플라즈마의 길이는 길어진다. 층류의 방전은 유리관 밖에서도 층류의 흐름이 일정 길이로 유지되므로 시료 표면에 조사되는 플라즈마 빔의 직경은 유리관의 직경 이하로 유지된다.

가스크로마토그라피-염광광도 검출기에 의한 혈장중 카르복실기 함유 약물의 정량 (Determination of Carboxyl Drugs by Gas Chromatography-Flame Photometric Detector)

  • 박만기;조영현;유무영;강탁림
    • 약학회지
    • /
    • 제30권4호
    • /
    • pp.180-184
    • /
    • 1986
  • Such carboxyl drugs as mefenamic acid, alclofenac, ketoprofen, cicloxilic acid and tolfenainic acid in rat plasma were determined by the gas chromatography flame photometric detector (GC-FPD). After methylthiomethyl (MTM) esterification with MTM-chloride in 1, 8-diazabicyclo [5.4.0] undec-7-ene (DBU) catalyst, determination of these drugs by this method was tried and compared with that by the GC-flame ionization detector (FID) method in respect to sensitivity and effect of inteferences. The results showed it was possible to analyze with accuracy by this method because of specificity of the FPD, although these drugs were not separated from interferences in plasma on GC column. The GC-FPD method was more sensitive than GC-FID method and the minimum detectable amount of monocarboxylic drugs on 3%, QF-1 column was about 15fmol/injection.

  • PDF

HPLC Method for the Determination of Nicorandil in Human Plasma

  • Park, Sun-Hee;Shin, In-Chul
    • Biomolecules & Therapeutics
    • /
    • 제16권2호
    • /
    • pp.168-172
    • /
    • 2008
  • The present study is to determine of sensitive nicorandil analysis method using HPLC and measure the pharmacokinetics parameters (bioavailability, $C_{max}$, $T_{max}$, Ke, $T_{1/2}$) of nicorandil (5 mg, Tab; Choongwae Pharma Corporation). Plasma (500 ul) was mixed with furosemide (internal standard, 500 ug/ml). Detection wavelength was 256 nm. The mixture of 0.01 M ammonium acetate and acetonitrile 80:20 (v/v) was used mobile phase. The HPLC separation was accomplished on ODC reverse HPLC column. The nicorandil was analyzed by a HPLC system, which consists of CAPCELL PAK C18 column (5 ${\mu}$m, 4.6 × 150 mm) and a chromatography data analysis S/W, using a isocratic mobile phase (mixture of 0.01 M ammonium acetate and acetonitrile 80:20 ) at 1.0 ml/min. Its sensitivity, selectivity, accuracy and precision must be adequate for the bioavailabilty study of nicorandil, and the linearity ($r^2$ ≥ 0.9994) of nicorandil was also proved in the range of 0.05 ug/ml . 3 ug/ml. The pharmacokinetic parameters of nicorandil (5 mg) tablets were measured as the follow. AUC: 0.19 ug/ml·hr, $C_{max}$: 0.14 ug/ml, $t_{max}$: 0.58 hr, Ke: 0.11 hr., $t_{1/2\beta}$: 6.76 hrs. This method is simple and sensitive HPLC method using UV detector for determination of nicorandil in human plasma.

On-line Trace Enrichment in High Performance Liquid Chromatography Using XAD-2 Precolumn for the Determination of Lonazolac in Human Plasma

  • Lee, Hye-Suk;Kim, Eun-Joo;Zee, Ok-Pyo;Lee, Yoon-Joong
    • Archives of Pharmacal Research
    • /
    • 제12권2호
    • /
    • pp.108-113
    • /
    • 1989
  • A new column-switching high performance liquid chromatographic method was developed for the determination of lonazolac in plasma. This method was based on the on-line trace enrichment of lonazolac using a precolumn packed with Amberlite XAD-2. The analysis was complete in 20 min. between injections and the limit of detection was $0.1{\mu}g/ml$ using $100{\mu}l$ of plasma. The method was linear in range of $0.1-10{\mu}g/ml$ with a correlation coefficient of 0.9991. Absolute recovery of lonazolac from the spiked plasma samples ranged from 95.6% to 97.1%. The method was shown to be reproducible over the concentration range studied.

  • PDF

Determination of barbiturates in plasma by gas chromatography-fralme photometric detector after N, N'-flame photometric detector after N, N'-dimethylthiomethyl derivatization

  • Hyung, Yung;Park, Man-Ki
    • Archives of Pharmacal Research
    • /
    • 제9권3호
    • /
    • pp.131-138
    • /
    • 1986
  • A specific and sensitive gas chromatographic (GC) procedure with the flame photometric detector (FPD) was developed for determination of barbiturates such as barbital, allobarbital, secobarbital, phenobarbital and thiopental in plasma. In order to evaluate the performance of the FPD, the results were campared with those of the flame ionization detector (FID). After extraction of barbiturates from plasma, the barbiturates were quantitatively N, N-dimethylthiometyl (MTM)-derivatized with methylthiomethyl chloride in 1, 8-diazabicyclo [5, 4, 0] undec-7-ene catalyst. The data indicate that the FPD is about 4 times more sensitive than the FID for barbiturates, although it is less reproducible. The FPD also produced chromatogram with less back ground for extracted plasma sample. The FPD also produced chromatogram with less background for extracted plasma sample. The minimum detectable amount of MTM-thiopental on 3% OV-225 column was 4, 4fmol and that of other MTM-barbiturate was about 10.0fmol.

  • PDF

이행형 토치에서의 아크 플라즈마의 물리적 거동에 관한 연구 (A study on the physical behavior of arc plasmas in transferred-type Torch)

  • 김외동;고광철;강형부
    • 대한전기학회논문지
    • /
    • 제45권3호
    • /
    • pp.415-425
    • /
    • 1996
  • This study presents an analytical method of solving the behaviors of arc plasma in a nozzle constricting transferred-type torch and purposes to obtain the basic data for the design of a plasma torch, which can be obtained from the temperature, pressure, velocities and voltage distributions. We have to solve some conservation equations simultaneously and need to know the exact thermal gas properties in order to obtain the correct behaviors of arc plasma. It is also necessary to give the relevant physical or geometric boundary conditions. For the simplicity of analysis, we assumed that (a) the plasma flow is laminar, (b)the local thermodynamic equilibrium, i.e. LTE, prevails over the entire arc column region. The electrode sheath effects were neglected and the nozzle area was excluded from the analysis by assuming that the current flow into the nozzle is zero. We solved the momentum transfer equation including the self-magnetic pinch effect, and obtained the temperature distribution from the energy conservation equation. From this temperature, we could get arc voltage distribution. (author). refs., figs., tabs.

  • PDF