• Title/Summary/Keyword: plasma application

Search Result 908, Processing Time 0.025 seconds

Development of a rapid HPLC method for the determination of penciclovir in human plasma using a monolithic column and its application to a bioequivalence study (모노리틱 칼럼을 이용한 혈장 중 펜시를로버의 HPLC 신속분석법 개발 및 이를 이용한 생물학적동등성시험)

  • Kim, Jin Hee;Park, Ah Yeon;Jung, Eun Ha;Lee, Cheol Woo;Lee, Tae Ho;Youm, Jeong-Rok
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.323-330
    • /
    • 2007
  • A simple and rapid HPLC method with fluorescence detection(FLD) for quantitation of penciclovir in human plasma using a monolithic column was developed and validated. Penciclovir and ganciclovir(internal standard, I.S.) were separated on a Chromolith column RP-18e ($4.6{\times}100mm$) with a mobile phase consisting of a mixture of (A) methanol/50 mM sodium phosphate buffer containing 200 mg/L sodium dodecyl sulfate (3/97, pH 2.5) and (B) methanol/50 mM sodium phosphate buffer containing 200 mg/L sodium dodecyl sulfate (50/50, pH 2.5) at a flow gradient of $1.6{\sim}4.0mL/min$. The retention times of penciclovir and internal standard were less than 4.0 min. Calibration curve was linear ($R^2=0.9994$) over a concentration range of $0.1{\sim}5{\mu}g/mL$. Intra-day precision, accuracy and inter-day precision were 1.36~8.55 %, 92.8~100.0 % and 0.93~5.62 %, respectively with a limit of quantitation at $0.1{\mu}g/mL$. The present HPLC-FLD method is sensitive, precise and accurate. The method described herein has been successfully used for the bioequivalence study of a famciclovir formulation product after oral administration to healthy Korean volunteers.

Magnetized inductively coupled plasma etching of GaN in $Cl_2/BCl_3$ plasmas

  • Lee, Y.H.;Sung, Y.J.;Yeom, G.Y.
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1999.10a
    • /
    • pp.49-49
    • /
    • 1999
  • In this study, $Cl_2/BCI_3$ magnetized inductively coupled plasmas (MICP) were used to etch GaN and the effects of magnetic confinements of inductively coupled plasmas on the GaN etch characteristics were investigated as a function of $Cl_2/BCI_3$. Also, the effects of Kr addition to the magnetized $Cl_2/BCI_3$ plasmas on the GaN etch rates were investigated. The characteristics of the plasmas were estimated using a Langmuir probe and quadrupole ma~s spectrometry (QMS). Etched GaN profiles were observed using scanning electron microscopy (SEM). The small addition of $Cl_2/BCI_3$ (10-20%) in $Cl_2$ increased GaN etch rates for both with and without the magnetic confinements. The application of magnetic confinements to the $Cl_2/BCI_3$ inductively coupled plasmas (ICP) increased GaN etch rates and changed the $Cl_2/BCI_3$ gas composition of the peak GaN etch rate from 10% $BCI_3$ to 20% $BCI_3$. It also increased the etch selectivity over photoresist, while slightly reducing the selectivity over $Si0_2$. The application of the magnetic field significantly increased positive $BCI_2{\;}^+$ measured by QMS and total ion saturation current measured by the Langmuir probe. Other species such as CI, BCI, and CI+ were increased while species such as $BCl_2$ and $BCI_3$ were decreased with the application of the magnetic field. Therefore, it appears that the increase of GaN etch rate in our experiment is related to the increased dissociative ionization of $BCI_3$ by the application of the magnetic field. The addition of 10% Kr in an optimized $Cl_2/BCI_3$ condition (80% $Cl_2/$ 20% $BCI_3$) with the magnets increased the GaN etch rate about 60%. More anisotropic GaN etch profile was obtained with the application of the magnetic field and a vertical GaN etch profile could be obtained with the addition of 10% Kr in an optimized $Cl_2/BCI_3$ condition with the magnets.

  • PDF

Immunogenicity of Synthetic Peptide Specific for Major Immunogenic Determinat of Hepatitis B Surface Antigen (B형간염(型肝炎) 표면항원(表面抗原)의 주면역원(主免疫原) 결정기(決定基)에 특이(特異)한 합성(合成) Peptide의 면역원성(免疫原性)에 관한 연구(硏究))

  • Shin, Kwang-soon;Han, Su-nam
    • Korean Journal of Veterinary Research
    • /
    • v.25 no.1
    • /
    • pp.7-17
    • /
    • 1985
  • Many investigators have been pursuing various attempts so far to produce hepatitis B surface antigen(HBsAg) vaccines using the techniques such as isolation from plasma of chronic HBsAg carrier, recombinant DNA technique or preparation of synthetic peptides specific for immunogenic determinants. Hepatitis B virus can not grow on any cell lines by the tissue culture technique at the present time. The plasma of chronic HBsAg carrier is expensive and its source is limited. The HBsAg from the recombinant DNA technique gave still very low yield. Another approach, therefore, has been initiated to develop a synthetic hepatitis B virus vaccine. The possible use of several distinct synthetic vaccines in prophylaxis can be facilitated by availability of full synthetic immunogens. Peptides synthesized for potential application as antiviral vaccines have been mostly tested in the form of conjugates with carrier proteins, although the free synthetic peptide can be immunogenic. To understand basic knowledges on the antigenicity and immunogenicity of a synthetic peptide specific for major immunogenic determinant of HBsAg, a nonapeptide, $H_2N^{139}Cys-Thr-Lys-Pro-Thr-Asp-Gly-^{146}Asn-Aba$ COOH, which corresponds to HBsAg amino acid residues 139 to 147, was synthesized by the Merrifield's solid-phase method with a slight modification. The antigenicity and immunogenicity of this specific synthetic peptide were examined comparing with purified plasma-derived natural HBsAg. The results obtained are as follows; 1. The peptide synthesized showed the identical amino acid composition to the theoretical value. The degree of purification and molecular weight were acertained by methods of high performance liquid chromatography and mass spectrometry. 2. Using m-maleimidobenzoyl-N-hydroxysuccinimide ester as a conjugating agent, the synthetic peptide was conjugated to rabbit albumin and ${\gamma}$-globulin, tetanus and diphtheria toxoids, and keyhole limpet hemocyanin. Their conjugation yields were 8.3, 9.5, 15.8, 13.5, and 11.2%, respectively. 3. The natural HBsAg was purified from plasma of chronic HBsAg carrier. By the electron microscopic observation of the purified natural HBsAg preparation, no Dane particles were observed and the preparation showed negative DNA polymerase activity. 4. Antigenicity of the synthetic peptide and the plasma-derived natural HBsAg was determined by competition radioimmunoassay using $^{125}I$-natural HBsAg. Their 50% inhibitions appeared as $90{\mu}g/ml$ and $0.12{\mu}g/ml$ for the synthetic peptide and the natural HBsAg, respectively. This indicates that the former was about 750-fold less antigenic than the latter. 5. Immunogenicity of the synthetic peptide was determined by administering the peptide-carrier conjugates into rabbits with and without Freund's complete adjuvant. Regardless the carrier proteins and adjuvant, positive immune responses to the synthetic peptide were observed. The higher antibody titers, however, were shown in the groups administered with Freund's complete adjuvant. 6. Immunizing dose 50% in mice of the various peptide-carrier conjugates was 5.47, 6.00, 65.16, 31.25 and $13.03{\mu}g/dose$ for rabbit albumin and ${\gamma}$-globulin, tetanus and diphtheria toxoids, and keyhole limpet hemocyanin, respectively, while the natural HBsAg showed $0.65{\mu}g/dose$. 7. It was postulated that homologous proteins prefer to heterologous ones as the carriers.

  • PDF

EFFECT OF OCTANOL, THE GAP JUNCTION BLOCKER, ON THE REGULATION OF FLUID SECRETION AND INTRACELLULAR CALCIUM CONCENTRATION IN SALIVARY ACINAR CELLS (흰쥐 악하선 세포에서 gap junction 봉쇄제인 octanol이 타액분비 및 세포내 $Ca^{2+}$ 농도 조절에 미치는 영향)

  • Lee, Ju-Seok;Seo, Jeong-Taeg;Lee, Syng-Il;Lee, Jong-Gap;Sohn, Heung-Kyu
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.399-415
    • /
    • 1999
  • From bacteria to mammalian cells, one of the most important mediators of intracellular signal transduction mechanisms which regulate a variety of intracellular processes is free calcium. In salivary acinar cells, elevation of intracellular calcium concentration ($[Ca^{2+}]_i$) is essential for the salivary secretion induced by parasympathetic stimulation. However, in addition to $[Ca^{2+}]_i$, gap junctions which couple individual cells electrically and chemically have also been reported to regulate enzyme secretion in pancreatic acinar cells. Since the plasma membrane of salivary acinar cells has a high density of gap junctions, and these cells are electrically and chemically coupled with each other, gap junctions may modulate the secretory function of salivary glands. In this respect, I planned to investigate the role of gap junctions in the modulation of salivary secretion and $[Ca^{2+}]_i$, using mandibular salivary glands of rats. In order to measure the salivary flow rate, fluid was collected from the cannulated duct of the isolated perfused rat mandibular glands at 2 min intervals. $[Ca^{2+}]_i$, was measured from the cells loaded with fura-2 by spectrofluorometry. The results obtained were as follows: 1. CCh-induced salivary secretion was reversibly inhibited by 1 mM octanol, a gap junction blocker. 2. CCh-induced increase in $[Ca^{2+}]_i$, was also reversed by the application of 1 mM octanol. 3. Octanol did not block the initial increase in $[Ca^{2+}]_i$ caused by CCh, which suggested that the reduction of $[Ca^{2+}]_i$, caused by gap junction blockade was not resulted from the inhibition of $Ca^{2+}$ release from intracellular $Ca^{2+}$ stores. 4. Addition of octanol during stimulation with $1{\mu}M$ thapsigargin, a potent microsomal ATPase inhibitor, reduced $[Ca^{2+}]_i$, to the basal level. This suggested that inhibition of gap junction permeability closed plasma membrane $Ca^{2+}$ channels. 5. 2,5-di-tert-butyl-1,4-benzohydroquinone (TBQ) generated $[Ca^{2+}]_i$ oscillations resulting from periodic influx of $Ca^{2+}$ via plasma membrane. The TBQ-induced $[Ca^{2+}]_i$ oscillations were stopped by the application of 1mM octanol which implicated that gap junctions modulate the permeability of plasma membrane $Ca^{2+}$ channels. 6. Glycyrrhetinic acid, another well known gap junction blocker, also inhibited CCh-induced salivary secretion from rat mandibular glands. These results suggested that gap junctions play an important role in the modulation of fluid secretion from the rat mandibular glands and this was probably due to the inhibition of $Ca^{2+}$ influx through the plasma membrane $Ca^{2+}$ channels.

  • PDF

Application of $CF_{4}$ plasma etching to $Ta_{0.5}Al_{0.5}$ alloy thin film ($CF_{4}$ 기체를 이용한 $Ta_{0.5}Al_{0.5}$ 합금 박막의 플라즈마 식각)

  • 신승호;장재은;나경원;이우용;김성진;정용선;전형탁;오근호
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.9 no.1
    • /
    • pp.60-63
    • /
    • 1999
  • Application of reactive ion etching (RIE) technique to Ta-Al alloy thin film with a thickness of $1000{\AA}$ was studied. $CF_{4}$ gas could be used effectively to etch the Ta-Al alloy thin film. The etching rate in the thin film with Ta content of 50 mol% was about $67{\AA}/min$. NO selectivity between the Ta-Al alloy film and $SiO_{2}$ film was observed during the etching using the $CF_{4}$ gas. The etching rate of the $SiO_{2}$ layer was 12 times faster than that of the Ta-Al alloy thin film. It was also observed that photoresist of AZ5214 was more useful than Shiepley 1400-27 in RIE with the $CF_{4}$ gas.

  • PDF

Development of Membrane Strip Assay System for Lipoprotein Cholesterol Based on Liquid-Phase Enzyme Reactions (액상 효소반응을 이용한 Membrane Strip 형 Cholesterol 측정시스템의 개발)

  • 신인수;목락선;장미라;백세환
    • KSBB Journal
    • /
    • v.13 no.5
    • /
    • pp.577-584
    • /
    • 1998
  • A sensitive membrane strip assay for plasma lipoprotein cholesterol that can be performed without handling reagents has been investigated. We previously developed an assay system with immobilized enzymes (cholesterol esterase and cholesterol oxidase) on the surfaces of nitrocellulose membrane(1). In such a case, the amount of enzymes present on the membrane was limited by its surface area and, thus, the detection capability was relatively poor (> 50 mg/dL cholesterol). To overcome this problem, we devised a new system with non-immobilized enzymes by placing them within interstitial spaces of a celullose membrane pad in a dry state. Upon contact with sample medium, the enzymes were immediately dissolved and participated in the reactions with cholesterol in a liquid phase. We constructed a user-friendly system consisting of four membrane pads fro sample application, cholesterol decomposition, color development as signal, and medium absorption to invoke a continuous flow (sequential location from the bottom). A sample containing lipoproteins was added into the application pad by capillary action and transferred to the next pad for decomposition. The decomposition pad (namely, enzyme pad) contained a detergent (sodium cholate) for the destruction of lipoprotein particles, the two enzymes for cholesterol decomposition, and a chromogen (3,3'-diaminobenzidine). As a consequence of the enzyme reactions, hydrogen peroxide was produced, and then reacted in the presence of the chromogen with horseradish peroxidase immobilized on the signal generation pad. Finally, a colorimetric signal directly proportional to the cholesterol concentration was produced. The detection limit determined from this system under optimal conditions was at least 2 times lower than of the enzyme-immobilized system.

  • PDF

Targeted and sustained delivery of hydrocortisone to normal and stratum corneum-removed skin without enhanced skin absorption using a liposome gel

  • Kim, Moon-Kyoung;Chung, Suk-Jae;Lee, Min-Hwa;Cho, Ae-Ri;Shim, Chang-Koo
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1996.04a
    • /
    • pp.278-278
    • /
    • 1996
  • Judging from hydrocortisone concentration in dosing area, the extent of absorption was reduced in the liposome-gel formulation. However, higher and sustained skin concentrations of hydrocortisone were achieved for the liposome-gel as compared to the ointment. Drug concentration in both viable and deep skin reached its maximum within 0.5 h after application of both formulations to both skin types. Drug concentrations in both skins from the ointment declined with time, while those from the liposome-gel were greatly sustained. The sustainment by the liposome-gel was more remarkable in the viable skin than in the deep skin. Drug concentration in the viable skin could be maintained at a nearly constant level for over 8 h by applying the liposome-gel. As a result, a 5-fold higher viable skin drug concentration was obtained from the liposome-gel than from the ointment at 8 h after the application to the SC-removed skin. However, the plasma concentration of hydrocortisone at 4 h from the liposome-gel was only one-fourth (p<0.01) the value from the ointment when the drug was applied to the SC-removed skin, consistent with. the lower urinary (one-third, p<0.05) and fecal (one-half, p<0.05) excretion. Conclusions : Retarded diffusion of the drug from the skin to the systemic blood stream appears to be a potential factor in the sustained skin concentration of hydrocortisone from the liposome-gel, Interaction of hydrocortisone in the skin with phosphatidylcholine, a component of the liposomes and skin, may well be a factor in retarding the diffusion of the drug in the skin.

  • PDF

The Effect of Demineralized Freeze - Dried Bone Allograft in Guided Bone Regeneration on Supra - Alveolar Peri - Implant Defects in Dogs (성견의 치조 연상 임플란트주위 결손부에서의 탈회냉동건조골과 e-PTEE막의 효과)

  • Kim, Chang-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.1
    • /
    • pp.57-74
    • /
    • 2001
  • The purpose of this study was to evaluate the adjunctive combined effect of demineralized freeze-dried bone allograft(DFDB) in guided bone regeneration on supra-alveo-lar peri-implant defect. Supra-alveolar perio-implant defects, 3mm in height, each including 4 IMZ titanium plasma-sprayed implants were surgically created in two mongrel dogs. Subsequently, the defects were treated with 1 of the following 3 modalities: Control) no membrane or graft application, Group1) DFDB application, Group2) guided bone regeneration using an expanded polytetra-fluoroethylene membrane, Group3) guided bone regeneration using membrane and DFDB. After a healing period of 12-week, the animals were sacrificed, tissue blocks were harvested and prepared for histological analysis. Histologic examination were as follows; 1. New bon formation was minimal in control and Group 1, but considerable new bone formation was observed in Group 2 and Group 3. 2. There was no osteointegration at the implant-bone interface in the high-polished area of group2 and Group 3. 3. In fluorescent microscopic examination, remodeling of new bone was most active during week 4 and week 8. There was no significant difference in remodeling rate between group 2 and group 3. 4. DFDB particles were observed, invested in a connective tissue matrix. Osteoblast activity in the area was minimal. The results suggest that guided bone regeneration shows promising results in supra-alveolar peri-implant defects during the 12 week healing period although it has a limited potential in promoting alveolar bone regeneration in the high-polished area. There seems to be no significant adjunctive effect when DFDB is combined with GBR.

  • PDF

The Study of Sputtered SiGe Thin Film Growth for Photo-detector Application (광검출기 응용을 위하여 스퍼터된 미세결정 SiGe 박막성장 연구)

  • Kim, Do-Young;Kim, Sun-Jo;Kim, Hyung-Jun;Han, Sang-Youn;Song, Jun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.6
    • /
    • pp.439-444
    • /
    • 2012
  • For the application of photo-detector as active layer, we have studied how to deposit SiGe thin film using an independent Si target and Ge target, respectively. Both targets were synthesized by purity of 99.999%. Plasma generators were generated by radio frequency (rf, 13.56 MHz) and direct current (dc) power. When Ge and Si targets were sputtered by dc and rf power, respectively, we could observe the growth of highly crystalline Ge thin film at the temperature of $400^{\circ}C$ from the result of raman spectroscopy and X-ray diffraction method. However, SiGe thin film did not deposit above method. Inversely, we changed target position like that Ge and Si targets were sputtered by rf and dc power, respectively. Although Ge crystalline growth without Si target sputtering deteriorated considerably, the growth of SiGe thin film was observed with increase of Si dc power. SiGe thin film was evaluated as microcrystalline phase which included (111) and (220) plane by X-ray diffraction method.

Prediction of Heavy Metal Content in Compost Using Near-infrared Reflectance Spectroscopy

  • Ko, H.J.;Choi, H.L.;Park, H.S.;Lee, H.W.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.12
    • /
    • pp.1736-1740
    • /
    • 2004
  • Since the application of relatively high levels of heavy metals in the compost poses a potential hazard to plants and animals, the content of heavy metals in the compost with animal manure is important to know if it is as a fertilizer. Measurement of heavy metals content in the compost by chemical methods usually requires numerous reagents, skilled labor and expensive analytical equipment. The objective of this study, therefore, was to explore the application of near-infrared reflectance spectroscopy (NIRS), a nondestructive, cost-effective and rapid method, for the prediction of heavy metals contents in compost. One hundred and seventy two diverse compost samples were collected from forty-seven compost facilities located along the Han river in Korea, and were analyzed for Cr, As, Cd, Cu, Zn and Pb levels using inductively coupled plasma spectrometry. The samples were scanned using a Foss NIRSystem Model 6500 scanning monochromator from 400 to 2,500 nm at 2 nm intervals. The modified partial least squares (MPLS), the partial least squares (PLS) and the principal component regression (PCR) analysis were applied to develop the most reliable calibration model, between the NIR spectral data and the sample sets for calibration. The best fit calibration model for measurement of heavy metals content in compost, MPLS, was used to validate calibration equations with a similar sample set (n=30). Coefficient of simple correlation (r) and standard error of prediction (SEP) were Cr (0.82, 3.13 ppm), As (0.71, 3.74 ppm), Cd (0.76, 0.26 ppm), Cu (0.88, 26.47 ppm), Zn (0.84, 52.84 ppm) and Pb (0.60, 2.85 ppm), respectively. This study showed that NIRS is a feasible analytical method for prediction of heavy metals contents in compost.