• Title/Summary/Keyword: plasma application

Search Result 912, Processing Time 0.029 seconds

A study of decomposition of sulfur oxides(harmful gas) using calcium dihydroxide catalyst by plasma reactions (Ca(OH)2촉매를 이용한 플라즈마 반응에 의한 황산화물(유해가스)의 제거에 관한 연구)

  • Kim, Dayoung;Hwang, Myungwhan;Woo, Insung
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.2
    • /
    • pp.237-246
    • /
    • 2014
  • Researches on the elimination of sulfur and nitrogen oxides with catalysts and absorbents reported many problems related with elimination efficiency and complex devices. In this study, decomposition efficiency of harmful gases was investigated. It was found that the efficiency rate can be increased by moving the harmful gases together with SPCP reactor and the catalysis reactor. Calcium hydroxide($Ca(OH)_2$), CaO, and $TiO_2$ were used as catalysts. Harmful air polluting gases such as $SO_2$ were measured for the analysis of decomposition efficiency, power consumption, and voltage according to changes to the process variables including frequency, concentration, electrode material, thickness of electrode, number of electrode winding, and additives to obtain optimal process conditions and the highest decomposition efficiency. The standard sample was sulfur oxide($SO_2$). Harmful gases were eliminated by moving them through the plasma generated in the SPCP reactor and the $Ca(OH)_2$ catalysis reactor. The elimination rate and products were analyzed with the gas analyzer (Ecom-AC,Germany), FT-IR(Nicolet, Magna-IR560), and GC-(Shimazu). The results of the experiment conducted to decompose and eliminate the harmful gas $SO_2$ with the $Ca(OH)_2$ catalysis reactor and SPCP reactor show 96% decomposition efficiency at the frequency of 10 kHz. The conductivity of the standard gas increased at the frequencies higher than 20 kHz. There was a partial flow of current along the surface. As a result, the decomposition efficiency decreased. The decomposition efficiency of harmful gas $SO_2$ by the $Ca(OH)_2$ catalysis reactor and SPCP reactor was 96.0% under 300 ppm concentration, 10 kHz frequency, and decomposition power of 20 W. It was 4% higher than the application of the SPCP reactor alone. The highest decomposition efficiency, 98.0% was achieved at the concentration of 100 ppm.

Angiogenic factor-enriched platelet-rich plasma enhances in vivo bone formation around alloplastic graft material

  • Kim, Eun-Seok;Kim, Jae-Jin;Park, Eun-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.1
    • /
    • pp.7-13
    • /
    • 2010
  • Although most researchers agree that platelet-rich plasma (PRP) is a good source of autogenous growth factors, its effect on bone regeneration is still controversial. The purpose of this study was to evaluate whether increasing angiogenic factors in the human PRP to enhance new bone formation through rapid angiogenesis. MATERIAL AND METHODS. In vitro, the human platelets were activated with application of shear stress, $20\;{\mu}g/ml$ collagen, 2 mM $CaCl_2$ and 10U thrombin/$1\;{\times}\;10^9$ platelets. Level of vascular endothelial growth factor (VEGF) and platelet microparticle (PMP) in the activated platelets were checked. In the animal study, human angiogenic factors-enriched PRP was tested in 28 athymic rat's cranial critical bone defects with $\beta$-TCP. Angiogenesis and osteogenesis were evaluated by laser Doppler perfusion imaging, histology, dual energy X-ray densinometry, and micro-computed tomography. RESULTS. In vitro, this human angiogenic factors-enriched PRP resulted in better cellular proliferation and osteogenic differentiation. In vivo, increasing angiogenic potential of the PRP showed significantly higher blood perfusion around the defect and enhanced new bone formation around acellular bone graft material. CONCLUSION. Angiogenic factor-enriched PRP leads to faster and more extensive new bone formation in the critical size bone defect. The results implicate that rapid angiogenesis in the initial healing period by PRP could be supposed as a way to overcome short term effect of the rapid angiogenesis.

Generation of neutral stream from helicon plasma and its application to Si dry etching (헬리콘 플라즈마로부터 중성입자 흐름의 생성 및 이를 이용한 실리콘의 건식식각)

  • 정석재;양호식;조성민
    • Journal of the Korean Vacuum Society
    • /
    • v.7 no.4
    • /
    • pp.390-396
    • /
    • 1998
  • Neutral stream was generated from Helicon plasma source and was applied to etch silicon for the purpose of preventing physical and electrical damages from the bombardment of charged particles with high translation energy. By installing a permanent magnet and applying positive bias beneath the substrate, the cusp-magnetic and electric fiddles were generated in order to remove the charged particles from the downstream plasma. As a result, the electron density and ion density in the vicinity of the substrate were reduced by 1/1000 and 1/10, respectively. The directional etching of silicon was observed and the etch rate was found to be very low to below 100 $\AA$/min at a pressure of $8.5{\times}10^{-4}$ Torr, when $Cl_2$ and 10% $SF_{sigma}$ etchant gases were used.

  • PDF

Effects of Process Parameters on Formation of TiN Coating Layer in Small Holes by PACVD (PACVD 방법으로 TiN 코팅시 공정변수가 작은 동공 내부의 코팅층 형성에 미치는 영향)

  • Kim, Deok-Jae;Jo, Yeong-Rae;Baek, Jong-Mun;Gwak, Jong-Gu
    • Korean Journal of Materials Research
    • /
    • v.11 no.6
    • /
    • pp.441-447
    • /
    • 2001
  • A study on the TiN coating layer in small holes on the Purpose of die-casting dies application has been performed with a PACVD process. For the hole having diameter of 4 mm. the uniform TiN coating layer in the hole to the depth of 20 mm was achieved using DC pulsed power source. To understand the forming mechanism of TiN coating layer, plasma diagnosis on Ti, $N_{2}^{+}$ and A $r^{+}$ emissions was carried out during plasma coaling process by optical emirssion spectroscopy. When the duty ratio was equal or over 50%, the Peaks of Ti,$ N_{2}^{+}$ and A $r^{+}$ emission were obviously observed. While duty ratio was equal or under 28.6%, no peaks for Ti, $N_{2}^{+}$ and A $r^$ were observed and the formation of TiN coating layer was rarely observed. For the coating in 4 mm hole diameter, the coating layer with bipolar process was two times deeper than that with unipolar process.

  • PDF

Characteristics of Coating Films on Hot-Dipped Aluminized Steel Formed by Plasma Electrolytic Oxidation Process at Different Current Densities (PEO 전류밀도 조건에 따른 알루미늄도금 강재상 산화코팅막의 특성)

  • Choi, In-Hye;Lee, Hoon-Seung;Lee, Myeong-Hoon
    • Journal of Surface Science and Engineering
    • /
    • v.50 no.5
    • /
    • pp.366-372
    • /
    • 2017
  • Plasma electrolytic oxidation(PEO) has attracted attention as a surface treatment which has high wear resistance and corrosion resistance. PEO is generally considered as cost-effective, environmentally friendly and superior in terms of coating performance. Most of studies about the PEO processes have been applied to light metals such as Al and Mg. Because the strength of Al and Mg is weaker than that of steel, there is a limit to the application. In this study, PEO process was used to form oxide coatings on Hot dipped aluminized(HDA) steel and the characteristics of the coating film according to the PEO current density were studied. The morphology was observed by SEM and component was analyzed by using EDS. The corrosion behaviors of PEO coating films were estimated by exposing salt spray test at 5 wt.% NaCl solution and measuring polarization curves in deaerated 3 wt.% NaCl solution. With the increase of PEO process current density, the pore size of the coating surface and the thickness of coating increased. It was confirmed that no Fe component was present on the coating surface. PEO coating films obviously showed good corrosion resistance compared with HDA. It is considered that the PEO coating acts as a barrier to protect the base material from external factors causing corrosion.

The diagnosis of Plasma Through RGB Data Using Rough Set Theory

  • Lim, Woo-Yup;Park, Soo-Kyong;Hong, Sang-Jeen
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.413-413
    • /
    • 2010
  • In semiconductor manufacturing field, all equipments have various sensors to diagnosis the situations of processes. For increasing the accuracy of diagnosis, hundreds of sensors are emplyed. As sensors provide millions of data, the process diagnosis from them are unrealistic. Besides, in some cases, the results from some data which have same conditions are different. We want to find some information, such as data and knowledge, from the data. Nowadays, fault detection and classification (FDC) has been concerned to increasing the yield. Certain faults and no-faults can be classified by various FDC tools. The uncertainty in semiconductor manufacturing, no-faulty in faulty and faulty in no-faulty, has been caused the productivity to decreased. From the uncertainty, the rough set theory is a viable approach for extraction of meaningful knowledge and making predictions. Reduction of data sets, finding hidden data patterns, and generation of decision rules contrasts other approaches such as regression analysis and neural networks. In this research, a RGB sensor was used for diagnosis plasma instead of optical emission spectroscopy (OES). RGB data has just three variables (red, green and blue), while OES data has thousands of variables. RGB data, however, is difficult to analyze by human's eyes. Same outputs in a variable show different outcomes. In other words, RGB data includes the uncertainty. In this research, by rough set theory, decision rules were generated. In decision rules, we could find the hidden data patterns from the uncertainty. RGB sensor can diagnosis the change of plasma condition as over 90% accuracy by the rough set theory. Although we only present a preliminary research result, in this paper, we will continuously develop uncertainty problem solving data mining algorithm for the application of semiconductor process diagnosis.

  • PDF

A Simple Purification of Apoliproteins A-I and B and Their Application to Cholestery Ester Transfer Assay

  • Cho, Kyung-Hyun;Park, Myung-Sook;Bok, Song-Hae;Park, Young-Bok
    • Preventive Nutrition and Food Science
    • /
    • v.1 no.1
    • /
    • pp.87-92
    • /
    • 1996
  • This study describes a stable and simple method for the measurement of cholesteryl ester transfer protein(CETP) activities using reconstituted HDL and LDL as substrates. Apolipoproteins (apo) A-I and -B were purified from hog plasma by a new strategy without ultracentrifugation and delipidation. a simple two-step column chromatography was administered. In the first step of phenyl-sepharose CL-4B column chro-matography, hydrophobic plasma proteins were isolated. The most hydrophobic proteins bound to the column appeared to be A-I and apo-B. Contaminat proteins were efficiently eliminated from the sample by washing the column with 0.3M NaCI containing buffer after loading the plasma on the column. Two pure proteins showing each single band on SDS-PSGE of apo A-I and apo-B were individually obtained by a subsequent gel filtration column chromatography(Sephadex G-200). This two-step purification was simple and inexpensive compared to the ultracentrifugation and/or delipidation method that are most commonly used. Reconstituted hight-density lipoproteins(HDL) and low-density lipoproteins(LDL) were prepared using the purified apo A-I and-B, respectively. When these artificially prepared HDL and LDL were used in the assays for CETP as the cholesteryl ester(CE) donor and acceptor respectively, the specific transfer of CE increased up to two fold compared to that used the native HSL and LDL.

  • PDF

Liquid chromatography-tandem mass spectrometric analysis of oleracone D and its application to pharmacokinetic study in mice

  • Lim, Dong Yu;Lee, Tae Yeon;Lee, Jaehyeok;Song, Im-Sook;Han, Young Taek;Choi, Min-Koo
    • Analytical Science and Technology
    • /
    • v.34 no.5
    • /
    • pp.193-201
    • /
    • 2021
  • We have demonstrated a sensitive analytical method of measuring oleracone D in mouse plasma using a liquid chromatography-tandem mass spectrometry (LC-MS/MS). Oleracone D and oleracone F (internal standard) in mouse plasma samples were processed using a liquid-liquid extraction method with methyl tertbutyl ether, resulting in high and reproducible extraction recovery (80.19-82.49 %). No interfering peaks around the peak elution time of oleracone D and oleracone F were observed. The standard calibration curves for oleracone D ranged from 0.5 to 100 ng/mL and were linear with r2 of 0.992. The inter- and intra-day accuracy and precision and the stability fell within the acceptance criteria. The pharmacokinetics of oleracone D following intravenous and oral administration of oleracone D at doses of 5 mg/kg and 30 mg/kg, respectively, were investigated. When oleracone D was intravenously injected, it had first-order elimination kinetics with high clearance and volume of distribution values. The absolute oral bioavailability of this compound was calculated as 0.95 %, with multi-exponential kinetics. The low aqueous solubility and a high oral dose of oleracone D may explain the different elimination kinetics of oleracone D between intravenous and oral administration. Collectively, this newly developed sensitive LC-MS/MS method of oleracone D could be successfully utilized for investigating the pharmacokinetic properties of this compound and could be used in future studies for the lead optimization and biopharmaceutic investigation of oleracone D.

Development of Jaspine B analysis using LC-MS/MS and its application: Dose-independent pharmacokinetics of Jaspine B in rats

  • Song, Im-Sook;Jeon, Ji-Hyeon;Lee, Jihoon;Lim, Dong Yu;Lee, Chul Haeng;Lee, Dongjoo;Choi, Min-Koo
    • Analytical Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.37-45
    • /
    • 2021
  • A rapid and simple LC-MS/MS analytical method in determining Jaspine B has been developed and validated in rat plasma. The standard curve value was 25 - 5000 ng/mL and the linearity, inter-day and intra-day accuracy and precision were within 15.0 % of relative standard deviation (RSD). The mean recoveries of Jaspine B ranged from 87.5 % to 91.2 % with less than 3.70 % RSD and the matrix effects ranged from 91.1 % to 108.2 % with less than 2.6 % RSD. The validated LC-MS/MS analytical method of Jaspine B was successfully applied to investigate the dose-escalated pharmacokinetic study of Jaspine B in rats following an intravenous injection of Jaspine B at a dose range of 1 - 10 mg/kg. The initial plasma concentrations and area under plasma concentration curves showed a good correlation with intravenous Jaspine B dose, indicating the dose independent pharmacokinetics of Jaspine B in rats. In conclusion, this analytical method for Jaspine B can be easily applied in the bioanalysis and pharmacokinetic studies of Jaspine B, including its administration at multiple therapeutic doses, or for making pharmacokinetic comparisons for the oral formulations of Jaspine B in small experimental animals as well as in vivo pharmacokinetic-pharmacodynamic correlation studies.

Development of a Sensitive Analytical Method of Polynemoraline C Using LC-MS/MS and Its Application to a Pharmacokinetic Study in Mice

  • Pang, Minyeong;Lee, Jaehyeok;Jeon, Ji-Hyeon;Song, Im-Sook;Han, Young Taek;Choi, Min-Koo
    • Mass Spectrometry Letters
    • /
    • v.12 no.4
    • /
    • pp.200-205
    • /
    • 2021
  • Polynemoraline C, a pyridocoumarin alkaloid, exhibits anticholinergic, anti-inflammatory, antitumor, and antimicrobial activities. A sensitive analytical method of polynemoraline C in mouse plasma was developed and validated using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Polynemoraline C and 13C-caffeine (internal standard) in mouse plasma were extracted using a liquid-liquid extraction method coupled with ethyl acetate. This extraction method resulted in high and reproducible extraction recovery in the range of 73.49%-77.31% with no interfering peaks around the peak retention time of polynemoraline C and 13C-caffeine. The standard calibration curves for polynemoraline C were linear over the range of 0.5-200 ng/mL with r2 > 0.985. The accuracy, precision, and the stability of the data were within acceptable limits on the FDA guideline. After intravenous and oral administration of polynemoraline C at doses of 5 and 30 mg/kg, respectively, the present method was successfully applied to the pharmacokinetic study of polynemoraline C. Polynemoraline C in mouse plasma showed a multi-exponential elimination pattern with a high volume of distribution values. This compound's absolute oral bioavailability was found to be 17.0%. Polynemoraline C's newly developed LC-MS/MS method can be used for further studies on the efficacy, toxicity, and biopharmaceutics of polynemoraline C, as well as its pharmacokinetic studies.