• 제목/요약/키워드: plasma application

검색결과 908건 처리시간 0.03초

Establishment of an analytical method for butaphosphan (BTP), a stress-attenuating agent, and its application in the preliminary pharmacokinetic evaluation of residues in olive flounder Paralichthys olivaceus

  • Lee, Ji-Hoon;Bae, Jun Sung;Lee, Chae Won;Yang, Chan Yeong;Choi, Ji-Sung;Choi, Sang-Hoon;Kang, Yue-Jai;Park, Kwan Ha
    • Fisheries and Aquatic Sciences
    • /
    • 제23권4호
    • /
    • pp.10.1-10.10
    • /
    • 2020
  • Background: Butaphosphan (BTP) has recently been introduced into the Korean aquaculture sector as a stressattenuating agent. In this study, a sensitive chemical analytical method was established for the detection of BTP in the olive flounder (Paralichthys olivaceus) tissues. Methods: Utilizing a method employing liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS), detection sensitivity, specificity, and precision were satisfactorily established. Temporal changes in the BTP plasma and muscle concentrations were assessed after a single intramuscular injection of BTP (50 and 150 mg/kg) to the olive flounder maintained at 13 ℃ or 22 ℃. Results: High BTP plasma levels were achieved immediately after the injection, and the drug was rapidly eliminated. Additionally, plasma BTP levels were markedly dependent on the elimination rate, which, in turn, seemed dependent on the water temperature, with the drug elimination half-life and mean residence time significantly shorter at 22 ℃ than 13 ℃. Overall, muscle BTP levels were markedly lower than the plasma levels. Notably, muscle levels were not influenced by water temperatures. Muscle BTP concentrations were used to estimate the necessary withdrawal period for drugs used in food fish, with BTP levels maintained far below the possible hazardous limit. Conclusions: In conclusion, the established LC-MS/MS method can be used for BTP residue detection with high sensitivity and reproducibility.

플라즈마 공법에 의한 암석파괴의 실험적 연구 (A Experimental Study of Rock Fragmentation with Plasma Method)

  • 윤지선;김상훈
    • 한국터널지하공간학회 논문집
    • /
    • 제4권1호
    • /
    • pp.27-35
    • /
    • 2002
  • 우리 나라 대부분의 토목현장에서는 암반의 굴착을 위하여 발파공법이 시행되고 있다. 발파공법은 기타 파암공법에 비하여 작업능률의 향상, 공사기간의 단축 등으로 많이 행해지고 있다. 그러나 발파작업은 발파진동, 발파소음, 비산 등으로 많은 피해를 발생하기도 한다. 따라서 본 연구에서는 미진동 공법 중에 하나인 플라즈마 공법의 특성, 파암효과 및 적용성에 대하여 검토해 보았다. 본 연구에서 나타난 플라즈마 공법에 의한 감쇠지수는 1.45~2.23이고 발파공법의 감쇠지수는 1.39~1.40으로 분석되었다. 그리고 시험파암 결과 파암지점과 계측지점과의 거리가 약 15m 이상인 지점부터는 대부분의 파암진동이 문화재나 컴퓨터 시설 등 민감한 보안물건에 대한 허용기준치인 0.2kine(cm/sec) 이내로 계측되었다. FFT(Fast Fourier Transform)분석 결과 당 현장에서 발파공법에 의해 계측된 주파수는 30~50Hz이고 플라즈마 공법의 주파수는 30~130Hz 사이에 분포하고 있다.

  • PDF

아르곤 플라즈마를 이용하여 유리기판에 증착된 PTFE 박막의 초친수 특성 연구 (Hydrophobic Properties of PTFE Film Deposited on Glass Surface Etched by Ar-plasma)

  • 이병로;배강;김화민
    • 한국전기전자재료학회논문지
    • /
    • 제27권8호
    • /
    • pp.516-521
    • /
    • 2014
  • An excellent hydrophobic surface has a high contact angle over 147 degree and the contact angle hysteresis below $5^0$ was produced by using roughness combined with hydrophobic PTFE coatings, which were also confirmed to exhibit an extreme adhesion to glass substrate. To form the rough surface, the glass was etched by Ar-plasma. A very thin PTFE film was coated on the plasma etched glass surface. Roughness factors before or after PTFE coating on the plasma etched glass surface, based on Wensel's model were calculated, which agrees well with the dependence of the contact angle on the roughness factor is predicted by Wensel's model. The PTFE films deposited on glass by using a conventional rf-magnetron sputtering. The glass substrates were etched Ar-plasma prior to the deposition of PTFE. Their hydrophobicities are investigated for application as a anti-fouling coating layer on the screen of displays. It is found that the hydrophobicity of PTFE films mainly depends on the sputtering conditions, such as rf-power, Ar gas content introduced during deposition. These conditions are closely related to the deposition rate or thickness of PTFE film. Thus, it is also found that the deposition rate or the film thickness affects sensitively the geometrical morphology formed on surface of the rf-sputtered PTFE films. In particular, 1,950-nm-thick PTFE films deposited for 30 minute by rf-power 50 watt under Ar gas content of 20 sccm shows a very excellent optical transmittance and a good anti-fouling property and a good durability.

AISI 316L강의 저온 플라즈마침질탄화처리 시 가스조성과 처리시간이 표면특성에 미치는 영향 (Influence of Gas Composition and Treatment Time on the Surface Properties of AISI 316L Austenitic Stainless Steels During Low-Temperature Plasma Nitrocarburizing Treatment)

  • 이인섭
    • 대한금속재료학회지
    • /
    • 제47권11호
    • /
    • pp.716-721
    • /
    • 2009
  • The major drive for the application of low-temperature plasma treatment in nitrocarburizing of austenitic stainless steels lies in improved surface hardness without degraded corrosion resistance. The low-temperature plasma nitrocarburizing was performed in a gas mixture of $N_{2}$, $H_{2}$, and carbon-containing gas such as $CH_{4}$ at $450^{\circ}C$. The influence of the processing time (5~30 h) and $N_{2}$ gas composition (15~35%) on the surface properties of the nitrocarburized layer was investigated. The resultant nitrocarburized layer was a dual-layer structure, which was comprised of a N-enriched layer (${\gamma}_N$) with a high nitrogen content on top of a C-enriched layer (${\gamma}_C$) with a high carbon content, leading to a significant increase in surface hardness. The surface hardness reached up to about $1050HV_{0.01}$, which is about 4 times higher than that of the untreated sample ($250HV_{0.01}$). The thickness of the hardened layer increased with increasing treatment time and $N_{2}$ gas level in the atmosphere and reached up to about $25{\mu}m$. In addition, the corrosion resistance of the treated samples without containing $Cr_{2}N$ precipitates was enhanced than that of the untreated samples due to a high concentration of N on the surface. However, longer treatment time (25% $N_{2}$, 30 h) and higher $N_{2}$ gas composition (35% $N_{2}$, 20 h) resulted in the formation of $Cr_{2}N$ precipitates in the N-enriched layer, which caused the degradation of corrosion resistance.

Application of cold atmospheric microwave plasma as an adjunct therapy for wound healing in dogs and cats

  • Jisu Yoo;Yeong-Hun Kang;Seung Joon Baek;Cheol-Yong Hwang
    • Journal of Veterinary Science
    • /
    • 제24권4호
    • /
    • pp.56.1-56.13
    • /
    • 2023
  • Background: Cold atmospheric plasma is a novel innovative approach for wound care, and it is currently underrepresented in veterinary medicine. Objectives: To investigate the efficacy and safety of using cold atmospheric microwave plasma (CAMP) as an adjunct therapy for wound healing in dogs and cats. Methods: Wound healing outcomes were retrospectively analyzed using clinical records of client-owned dogs and cats who were first managed through standard wound care alone (pre-CAMP period) and subsequently via CAMP therapy (CAMP period). The degree of wound healing was estimated based on wound size and a modified wound scoring system. Results: Of the 27 acute and chronic wounds included in the analysis, 81.48% showed complete healing after the administration of CAMP as an adjunct therapy to standard care. Most wounds achieved complete healing in < 5 weeks. Compared with the pre-CAMP period, the rate of wound healing significantly increased every week in the CAMP period in terms of in wound size (first week, p < 0.001; second week, p = 0.012; third week, p < 0.001) and wound score (first week, p < 0.001; second week, p < 0.001; third week, p = 0.001). No adverse events were noted except for mild discomfort and transient erythema. Conclusions: CAMP is a well-tolerated therapeutic option with immense potential to support the treatment of wounds of diverse etiology in small animal practice. Further research is warranted to establish specific criteria for CAMP treatment according to wound characteristics.

케토프로펜 겔제와 플라스터제의 피부 흡수 비교 (The Topical Absorption of Ketoprofen from Gels and Plaster in Human Volunteers)

  • 강원구;이창현;우종수;권광일
    • 약학회지
    • /
    • 제42권1호
    • /
    • pp.25-30
    • /
    • 1998
  • This study was designed to compare the absorption fraction and extent of ketoprofen gels and a matrix typed ketoprofen plaster patch. 3g (90mg as ketoprofen) of the two gels whi ch has oleohydrogel or hydrogel as a base, respectively, and 3 pieces of plaster patches (90mg as ketoprofen) were, applied in the area of 210$cm^2$ on forearm in 12 volunteers by cross over design. Blood samples were collected serially up to 24 hours and the plasma concentrations of ketoprofen were analyzed by HPLC using flurbiprofen as an internal standard. The detection limit of the assay was 1ng/ml of ketoprofen in plasma. The pharmacokinetic parameters (e.g. $AUC_{24hr}$, $AUMC_{24hr}$, MRT, Fraction Absorbed) were calculated from the plasma concentrations time data of each volunteer. The oleo-hydrogel showed significantly higher absorption fraction and extent of ketoprofen than the current hydrogel. The mean plasma concentrations of the oleo-hydrogel were increased to 98.46${\pm}$23.15ng/ml by 6 hour after application, and increased futher to 100.61${\pm}$18.65ng/ml at 24 hour. On the other hand, those of the hydrogel were increased 17.61${\pm}$18.65ng/ml at 5 hour to 34.68${\pm}$9.65ng/ml at 24 hour gradually. Therefore the plasma concentrations of oleo-hydrogel at each measured time were 3~7 times greater than those of the hydrogel with statistical significance. The $AUC_{24hr}$ (1797.26${\pm}$52.09ng.h/ml) of the oleo-hydrogel was 3.5 times greater (P<0.05) than that (516.17${\pm}$104.52ng.h/ml) of the hydrogel. The plaster patches showed higher bioavailability ($AUC_{24hr}$ 2877.37${\pm}$578.27ng.h/ml) than the olea-hydrogel ($AUC_{24hr}$ 1797.26${\pm}$52.09ng.h/ml) without statistical significance. But the absorption fraction of the oleo-hydrogel was rather higher than that of the plaster patches during the first 6 hours after administration. These results suggest that newly developed ketoprofen gel which is used oleo-hydrogel as a base would show excellent skin permeation on topical application for the corresponding clinical indications and could be absorbed as well as plaster patches.

  • PDF

탄소계 경질 박막의 연구 및 산업 적용 동향 (Trend in Research and Application of Hard Carbon-based Thin Films)

  • 이경황;박종원;양지훈;정재인
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.111-112
    • /
    • 2009
  • Diamond-like carbon (DLC) is a convenient term to indicate the compositions of the various forms of amorphous carbon (a-C), tetrahedral amorphous carbon (ta-C), hydrogenated amorphous carbon and tetrahedral amorphous carbon (a-C:H and ta-C:H). The a-C film with disordered graphitic ordering, such as soot, chars, glassy carbon, and evaporated a-C, is shown in the lower left hand corner. If the fraction of sp3 bonding reaches a high degree, such an a-C is denoted as tetrahedral amorphous carbon (ta-C), in order to distinguish it from sp2 a-C [2]. Two hydrocarbon polymers, that is, polyethylene (CH2)n and polyacetylene (CH)n, define the limits of the triangle in the right hand corner beyond which interconnecting C-C networks do not form, and only strait-chain molecules are formed. The DLC films, i.e. a-C, ta-C, a-C:H and ta-C:H, have some extreme properties similar to diamond, such as hardness, elastic modulus and chemical inertness. These films are great advantages for many applications. One of the most important applications of the carbon-based films is the coating for magnetic hard disk recording. The second successful application is wear protective and antireflective films for IR windows. The third application is wear protection of bearings and sliding friction parts. The fourth is precision gages for the automotive industry. Recently, exciting ongoing study [1] tries to deposit a carbon-based protective film on engine parts (e.g. engine cylinders and pistons) taking into account not only low friction and wear, but also self lubricating properties. Reduction of the oil consumption is expected. Currently, for an additional application field, the carbon-based films are extensively studied as excellent candidates for biocompatible films on biomedical implants. The carbon-based films consist of carbon, hydrogen and nitrogen, which are biologically harmless as well as the main elements of human body. Some in vitro and limited in vivo studies on the biological effects of carbon-based films have been studied [$2{\sim}5$].The carbon-based films have great potentials in many fields. However, a few technological issues for carbon-based film are still needed to be studied to improve the applicability. Aisenberg and Chabot [3] firstly prepared an amorphous carbon film on substrates remained at room temperature using a beam of carbon ions produced using argon plasma. Spencer et al. [4] had subsequently developed this field. Many deposition techniques for DLC films have been developed to increase the fraction of sp3 bonding in the films. The a-C films have been prepared by a variety of deposition methods such as ion plating, DC or RF sputtering, RF or DC plasma enhanced chemical vapor deposition (PECVD), electron cyclotron resonance chemical vapor deposition (ECR-CVD), ion implantation, ablation, pulsed laser deposition and cathodic arc deposition, from a variety of carbon target or gaseous sources materials [5]. Sputtering is the most common deposition method for a-C film. Deposited films by these plasma methods, such as plasma enhanced chemical vapor deposition (PECVD) [6], are ranged into the interior of the triangle. Application fields of DLC films investigated from papers. Many papers purposed to apply for tribology due to the carbon-based films of low friction and wear resistance. Figure 1 shows the percentage of DLC research interest for application field. The biggest portion is tribology field. It is occupied 57%. Second, biomedical field hold 14%. Nowadays, biomedical field is took notice in many countries and significantly increased the research papers. DLC films actually applied to many industries in 2005 as shown figure 2. The most applied fields are mold and machinery industries. It took over 50%. The automobile industry is more and more increase application parts. In the near future, automobile industry is expected a big market for DLC coating. Figure 1 Research interests of carbon-based filmsFigure 2 Demand ratio of DLC coating for industry in 2005. In this presentation, I will introduce a trend of carbon-based coating research and applications.

  • PDF

Application of ELISA for the Detection of Sulfamethazine Residue in Live Cattle

  • Lee, H.J.;Lee, M.H.;Han, In K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제14권3호
    • /
    • pp.378-381
    • /
    • 2001
  • Sulfamethazine has been widely used in swine for prevention or treatment of infections. Recently, the safety of the drug to consumers has been questioned because of carcinogenic effects. To prevent unwanted drug residues entering the human food chain, both government authorities and industries have established extensive control measures. The demands for reliable, simple, sensitive, rapid and low-cost methods for residue analysis of foods are increasing nowadays. In this study, we established a rapid prediction test for the detection of cattle with violative tissue residues of sulfamethazine. The recommended therapeutic dose of sulfamethazine (withdrawal time, 15 days) was administered to each of 10 cattle. Blood was sampled before drug administration and during the withdrawal period. The concentration of sulfamethazine in plasma, determined by a semi-quantitative ELISA, was compared to that of an internal standard (10 ppb). The absorbance ratio of internal standard to sample (B/Bs) was employed as an index to determine whether drug residues in cattle tissues were negative or positive. That is, a B/Bs ratio less than 1 was considered residue positive and if larger than 1 was considered negative. All 10 plasma samples from non-treated cattle showed negative to sulfamethazine. Sulfamethazine was detected in plasmas of treated cattle until Day 7 of withdrawal period. The present study showed that the semi-quantitative ELISA could be easily adapted in predicting residues of sulfamethazine in live cattle.

Sputtering Technique of Magnesium Oxide Thin Film for Plasma Display Panel Applications

  • Choi Young-Wook;Kim Jee-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권1호
    • /
    • pp.110-113
    • /
    • 2006
  • A high rate deposition sputtering process of magnesium oxide thin film in oxide mode has been developed using a 20 kW unipolar pulsed power supply. The power supply was operated at a maximum constant voltage of 500 V and a constant current of 40 A. The pulse repetition rate and the duty were changed in the ranges of $10\sim50$ kHz and $10\sim60%$, respectively. The deposition rate increased with rising incident power to the target. Maximum incident power to the magnesium target was obtained by the control of frequency, duty and current. The deposition rate of a moving state was 9 nm m/min at the average power of 1.5 kW. This result shows higher deposition rate than any other previous work involving reactive sputtering in oxide mode. The thickness uniformities over the entire substrate area of $982mm{\times}563mm$ were observed at the processing pressure of $2.8\sim9.5$ mTorr. The thickness distribution was improved at lower pressure. This technique is proposed for application to a high through-put sputtering system for plasma display panels.

Gastric Hemangioma Treated with Argon Plasma Coagulation in a Newborn Infant

  • Lee, Young Ah;Chun, Peter;Hwang, Eun Ha;Lee, Yeoun Joo;Kim, Chang Won;Park, Jae Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제20권2호
    • /
    • pp.134-137
    • /
    • 2017
  • Gastric hemangioma in the neonatal period is a very rare cause of upper gastrointestinal bleeding. We present a case of hemangioma limited to the gastric cavity in a 10-day-old infant. A huge, erythematous mass with bleeding was observed on the lesser curvature side of the upper part of the stomach. Surgical resection was ruled out because the location of the lesion was too close to the gastroesophageal junction. Medical treatment with intravenous $H_2$ blockers, octreotide, packed red blood cell infusions, local epinephrine injection at the lesion site, application of hemoclip, and gel-form embolization of the left gastric artery did not significantly alter the transfusion requirement. Hemostasis was achieved with endoscopic argon plasma coagulation (APC). After two sessions of APC, complete removal of the lesion was achieved. APC was a simple, safe and effective tool for hemostasis and the ablation of gastric hemangioma without significant complications.