• Title/Summary/Keyword: plant wastewater

Search Result 1,115, Processing Time 0.034 seconds

Study on the Performance of Constructed Wetland System for Sewage Treatment (인공습지 오수처리시설의 처리성능에 관한 연구)

  • 윤춘경
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.42 no.4
    • /
    • pp.96-105
    • /
    • 2000
  • Field experiment was performed from August 1996 to December 1999 to examine the performance of constructed wetland system for wastewater treatment in rural area. The constructed wetland system was installed in Konkuk University and the effluent from septic tank of school building was used as an influent to the treatment basin. The treatment basin was composed of sand bed with planted reed. From August 1996 to June 1998 the hydraulic loading rate was fixed with about 15.63cm/day and theoretical detention time was 1.38 days, and from July 1998 to December 1999 the hydraulic loading rate was about 6.25cm/day and theoretical detention time was 3.5days. It worked continuously even during winter time, and the sewage flowed without freezing even when average daily air temperature was below -1$0^{\circ}C$. Average removal rate of BOD , COD, and SS was about 70%, T-P removal rate was about 50.8% , and T-N removal rate was 23.9%. The reason for poor T-N removal might be due to high influent concentration and short retention times. At the later years BOD and COD removal rates were increased , and SS and T-P removal rates did not change significantly , but T-N removal rates were decreased. The effluent of the wetland system often effluent water quality standards for sewage treatment plant, therefore, further treatment would be required if the effluent need to be discharged to the public water. Wetland system involves relatively large land area and could be suitable for rural area. Therefore, utilization of reclaimed sewage for agricultural purpose or subsequent land treatment is recommended as a ultimate disposal of sewage for agricultural purpose or subsequent land treatment is recommended as a ultimate disposal of sewage in rural area.

  • PDF

Population Dynamics of Zacco platypus in Gap-Stream and Its Relation with Water Quality

  • Shin, Young-Eun; Choi, Ji-Woon;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.42 no.4
    • /
    • pp.422-431
    • /
    • 2009
  • This study was to provide basic data for aquatic ecosystem research using fishes. Field sampling was carried out at five selected sites of Gap Stream, and fish samples, especially for a selection of sentinel species were collected three times in June, September, and October 2007. We analyzed total length distribution of Zacco platypus in relation with the season and the sampling sites, and then compared with total body weight, condition factor (K), and age distribution of the fish. The fish population data were compared with physico-chemical water quality, obtained from the Ministry of Environment, Korea. Water quality analysis showed a significant nutrient enrichment, based on total nitrogen (TN) and total phosphorus (TP), and organic matter pollution, based on biological oxygen demand (BOD) and chemical oxygen demand (COD) in the Site 5, which is directly influenced by wastewater disposal plant (WDP). Population analysis of the sentinel species showed that the total number of individuals, age distribution, and the population size-structure were influenced by the effluents from the WDP, and that reproductive failure of young-age population were evident in Site 5. According to the relation analysis of total weight to K, the disturbed population was mainly attributed to combined effects of habitat modifications and chemical degradations. Regression analysis of K values against water quality parameters showed significant (p<0.05) positive relations with nutrient and organic matter contents. Our data suggest that the population structure using a sentinel fish species reflected the ambient water quality in the stream and that diagnosis of aquatic ecosystem health using Z. platypus population may be practical for water resource and ecosystem conservations.

A Study on the Treatment of Parathion Pesticide Using Marsh and Pond Type Constructed Wetlands (Marsh와 Pond 형태의 인공 습지를 이용한 Parathion 농약의 처리에 관한 연구)

  • Kim, Se-Kyung;Choi , Jong-Kyu;Oh, Se-Hee;Kang, Ho-Jeong;Zoh, Kyung-Duk
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.3
    • /
    • pp.214-220
    • /
    • 2004
  • The microcosm type wetland systems were constructed in order to treat wastewater contaminated with parathion. The microcosm reactor consisted of marsh and pond type. The experiment was carried out using batch (marsh or pond) and continuous (marsh-pond and pond-marsh type) systems. In the batch reactor, marsh-type wetland completely removed parathion in water within 8 days, while pond reactor removed 97% of parathion during the same period. During parathion degradation, the amount of 4-nitrophenol production, one of the metabolites from parathion degradation, was higher in marsh-type batch reactor. In the continuous systems, both marsh-pond and pond-marsh combination systems effectively removed parathion from water, and the production of 4-nitrophenol was also minimal. In the extraction experiment, the parathion and its metabolite were not found in the wetland soil and the plant. In order to achieve both aerobic and anaerobic conditions, the continuous wetland system combining marsh and pond type can be the alternative for the non-point source pollutants such as parathion pesticide.

A Study on the Development Trends of Wastewater Sludge Treatment Technology (하·폐수 슬러지 처리기술의 개발 동향에 관한 연구)

  • Lee, Chaeyoung;Chung, Woojin;Kim, Jitae
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.8
    • /
    • pp.5-15
    • /
    • 2016
  • As the increase of domestic sewage treatment plant and reinforcement of the standard of effluent water quality continues, the volumes of sewage sludge are consistently increasing. Existing treatment of sewage sludge, such as incineration and ocean dumping has been prohibited because of air pollution and prohibitions towards ocean dumping, and in turn, recycling and energy recovery from waste methods have being studied recently. However, the lack of technical level and systematic analyses of application technique are problems, that future analysis of such relative technique would be required. The present study has been investigated as follows, management technique of sludge, patent on refuse-derived fuel and increase biogas production and utilizable technology, trend of research paper. Furthermore, research development from five developed nations (Korea, Japan, China, United States, and United Kingdom), domestic and foreign have been investigated and analyzed by section. In this study, the future technical field which is required for effective management of sludge has been suggested.

Characteristics of Carbon Dioxide Gasification for Sewage Sludge in Microwave (마이크로웨이브에 의한 하수 슬러지 이산화탄소 가스화 특성)

  • JEONG, BYEORI;YOON, SOOHYUK;CHUN, YOUNGNAM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.2
    • /
    • pp.192-200
    • /
    • 2016
  • A characteristics of microwave drying-gasification was analyzed for converting a dewatered sewage sludge generated a wastewater treatment plant. Gas (60%) was the largest component of the product of microwave gasification, followed by sludge char (33%) and tar (2%). The main components of the producer gas were hydrogen (33%) and carbon monoxide (40%), and there was some methane and hydrocarbons ($C_2H_4$, $C_2H_6$, $C_3H_8$). Larger nitrogen and smaller oxygen amounts were generated. Gravimetric tar generated $414g/m^3$. This means a total tar which is a heavy hydrocarbons from the volatile organic substance in the sewage sludge. Selected light tars were benzene, anthracene, naphthalene, pyrene, showing lower concentrations as 2.62, 0.37, 0.49, $0.28g/m^3$, respectively. Sludge char has larger meso pores which is a mean pore size of $50.85{\AA}$ and has high adsorptivity. An amount of adsorption was $228.71cm^3/g$, showing higher quantity than acommercial adsorbers. This indicates that the gas obtained from the microwave gasification of wet sewage sludge can be used as fuel, but the heavy tar in the gas must be treated. Sludge char can be used as a tar reduction adsorbent in the process, and then burns as a solid fuel.

Study on the Combined Treatment of Municipal Leachate and Sewage by Sequencing Batch Reactor. (연속회분식활성슬러지공법을 이용한 매립지 침출수와 하수의 병합처리에 관한 연구)

  • 이병인;이상혁
    • Journal of Environmental Science International
    • /
    • v.2 no.2
    • /
    • pp.145-152
    • /
    • 1993
  • An experimental research was conducted in order to study the treatability of leachate and a combined wastewater of municipal landfill leachate and municipal sewage. The landfill leachate was that of Nanjido landfill site, and the municipal sewage was obtained from Chungnang municipal sewage treatment plant of Seoul. Several sets of bench-scale sequencing batch reactor(SBR) were used as experimental apparatus. Specially investigated items in this experiment were the removal efficiency of substrate and the influence of the hydraulic retention time(HRT). The experiment lasted for about 8 months. The result are as follows ; 1) The characteristics of leachate were pH 7.4~8.1, BOD 280~450 mg/l, COD 1300 ~ 1350 mg/l, T-N 2021 ~2110 mg/1,7-P 2.7 ~3.2 mg/l, Cl-3540 ~4085 mg/l, and heavy metals are a very small amount. And the characteristics of sewage Ivere pH 6.9~7.3, BOD 78.4~129.3 mg/1, COD 121.2~305.0 mg/l, T-N 14.9~36.4 mg/l, T-P 1.3 ~5.9 mg/l. 2) The treatability of leachate alone was not treat well. So for the good treatment of leachate, it was necessary to deal with the pretreatment before biological treatment and a combined treatment of municipal serfage. 3) The various contents of the leachate were 5%, 10%, and 50% and the removal efficiency of COD was 86.0%, 82.8%, 60.6%, and 31.7%. The maximum content of the leachate which could be sucessfully treated by SBR in the combined treatment was 10% of that of sewage.

  • PDF

Optimization of Operation Conditions for Improving the Nitrogen Removal Efficiency in Wastewater Treatment Plant (질소제거효율 향상을 위한 하수처리장 최적 운전조건 도출 연구)

  • Choi, Eun-Hee;Bram, Klapwijk;Mathijs, Oosterhuis
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.1
    • /
    • pp.25-31
    • /
    • 2010
  • 네덜란드 브리젠빈 하폐수처리장 최종방류수의 $NH_4$-N 및 TN(Total Nitrogen)농도를 방류수 수질기준인 각각 4 mg/L와 10 mg/L에 맞추기 위한 최적의 운전조건을 도출하기 위해 다양한 제어시스템이 시뮬레이션 되었다. 본 연구에 사용된 모델은 IWA(International Water Association) 활성슬러지 모델 No.1 (ASM No.1)이었고, GPS-X가 시뮬레이터로 사용되었다. 모델링을 위한 매개변수 민감도 분석결과 ASM No.1의 총 19개 매개변수 중 8개 변수 ($Y_H$, ksh, koh, $b_H$, ${\mu}_a$, $k_{NA}$, kh, ka)가 방류수 수질에 영향을 미치는 것으로 조사되었고 이들 매개변수에 대해 보정을 수행하여 사용하였다. SRT, 호기/무산소기간, 외부탄소원 주입시간 변화에 따른 방류수질 변화를 시뮬레이션하였는데, 호기/무산소 11h/1h인 조건에서 SRT가 20일에서 25일로 증가되면 $NH_4$-N가 5.0 mg/L에서 2.9 mg/L로 감소되었고 호기/무산소 2h/1h의 조건에서는 SRT증가에 따라 $NH_4$-N은 큰 감소를 보이지만, 바이패스되는 유입수량의 감소로 탈질율이 낮아 방류수 TN이 11.1~11.5 mg/L로 예측되는 결과가 도출되었다. 탈질율을 높이기 위한 아세트산 주입은 동일한 양의 아세트산을 무산소 전기간 (1h)동안 균일 주입하는 것 보다는 무산소 초기 15분내에 주입하는 것이 효율적인 것으로 나타났다.

Feasibility Study of small hydropower at a municipal wastewater treatment plant by model analysis (모델분석을 통한 하수처리장 소수력발전 경제성 평가)

  • Kim, Won-Kyoung;Kim, Dong-Soo;Kang, Ji-Hoon;Chae, Kyu-Jung;Kim, Jung-Yeon;Lee, Chul-Hyung;Park, Wan-Soon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.216-220
    • /
    • 2012
  • 본 연구는 경기도 용인시에 위치한 공공하수처리장을 대상으로 소수력발전 성능특성을 예측하고 경제성을 분석하여 소수력발전소의 건설타당성을 제시하였다. 방류구에서의 수준측량 조사에 따르면 실제 유효 낙차는 4.3m로 나타났다. 최근 5년간 방류량 자료를 살펴보면 일평균 실제 처리량은 약 $30,000m^3/day$로 나타났으며, 우수 유입과 물 사용량이 증가하는 여름 및 가을에 처리량이 증가하였다. 설계유량은 유량변화에 따른 누적 확률밀도와 유량지속곡선에 근거해 산정하였으며, 시간빈도로 보았을 때 17%의 유량이 지속되는 $0.35m^3/sec$가 설계유량으로 나타났다. 예상되는 수차 발전용량은 11kW급이며, 시스템 가동율은 74%, 그리고 계통선에 송출될 수 있는 연 전력생산량은 71.3MWh로 나타났다. 경제성 평가는 신재생에너지 경제성 분석 도구인 RETScreen 프로그램을 사용하여 B/C ratio, IRR, 개발투자비 등의 경제성 평가지표들을 산정하였다. 편익(Benefit) 산정시 전력기준단가는 133.67원/kWh, 할인율 7%를 적용하였으며, 비용(Cost) 산정시 유지관리비는 초기 건설비의 1%, 사용연한 30년을 적용하였다. 경제성 분석결과 기흥레스피아의 소수력발전소 건설시 초기 건설공사비가 $165,000 일 때, B/C 1.0, NPV $3,534, 투자회수기간 15.1년으로 산정되었고 따라서 초기 건설비용이 $165,000 이하일 때 가장 경제적인 것으로 파악되었다.

  • PDF

Investigation for Streamflow Measurement of Small Stream using Dilution Discharge Method during Low Flow Season (갈수기 소하천에서 희석유량법을 이용한 유량측정의 적용성 검토)

  • Kim, Gee Hyeong;Kim, Jeongkon;Lee, Sanguk
    • Journal of Wetlands Research
    • /
    • v.8 no.4
    • /
    • pp.59-67
    • /
    • 2006
  • In this study, dilution discharge method to measure streamflow using water quality data at small streams during low flow season was applied and compared with the conventional method using flowmeter combined with cross-sectional measurement. Streamflow were measured using both methods in Dal-cheon around Naesok Wastewater Treatment Plant located in Boeun, Chugbuk. This stream is reported to suffer from excessive algal growth in spring. An average flowrate difference of $0.004m^3/sec$ was obtained between the two methods. Once further tested for various conditions, the simple water quality method suggested in this study can be used effectively to estimate stream flowrates during low flow seasons where no measuring facilities such as weirs and flowmeters are not available or water depths are too small to measure flow velocities and exact cross-sections.

  • PDF

Characterization of Polyurethane and Soil Layers for In-situ Treatment of Landfill Leachate (매립지 침출수 현장 처리를 위한 폴리우레탄과 개질토의 특성 분석 실험에 관한 연구)

  • Park, Chan-Soo;Jung, Young-Wook;Park, Joong sub;Back, Won seok;Shin, Won sik;Chun, Byung sik;Han, Woo-Sun;Park, Jae-Woo
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.2
    • /
    • pp.281-286
    • /
    • 2007
  • A chemical and biological permeable barrier with economic feasibility is suggested to treat landfill leachate in this study. The proposed composite layers consist of bentonite, and polyurethane (PU) foam that is mixed with powdered activated carbon (PAC) and inoculated with microorganisms from local wastewater treatment plant. Each layer is mixed with local sand, and yellow brown soil. Batch tests were conducted to investigate the sorptions of nitrate on the PU foam and PAC, and nitrification/denitrification rate of each layer material. Nitrification occurred in 30 minutes with initial ammonia concentration of 100 mg/L, and the concentration of nitrate attached in the PU foam increased after 270 minutes. Results of denitrification batch tests showed 76.6%, 87.3% and 88% of nitrate removal efficiency at 10%, 20% and 30% of the volume ratio of PU foam, respectively. The pH increased from 7 to 9.42, and alkalinity increased from 980 mg/L to 1720 mg/L during the denitrification batch tests. In the column experiments using the proposed composite layers with 20% of the volume ratio of the PU foam, about 96% of BOD, 63% of COD, 58.1~79.5% of total nitrogen were removed.