• 제목/요약/키워드: plant wastewater

검색결과 1,114건 처리시간 0.025초

하수처리수의 재이용을 위한 벼 재배시험 (Rice Cultivation with Reclaimed Wastewater Irrigation for Wastewater Reuse)

  • 강문성;박승우;김상민;성충현
    • 한국농공학회논문집
    • /
    • 제46권1호
    • /
    • pp.75-86
    • /
    • 2004
  • The objective of the research is to develop agricultural resue technologies of reclaiming the effluents from a municipal wastewater treatment plant and reusing for irrigated rice paddies. The Suwon wastewater treatment plant was selected for wastewater reuse tests. The control was the plots with groundwater irrigation (TR#1), the treatment (TR#2) using polluted stream water as it was, and three others using wastewater after treatment. Three levels of wastewater treatments were employed: the effluent from the wastewater treatment plant (TR#3), sand filtering after treatment plant(TR#4), and ultra-violet treatment after sand filtering (TR#5). The randomized block method was applied to wastewater application to paddy rice with five treatments and six replica. The effects of various wastewater treatment levels on water quality, paddy soil, crop growth, yields, and the health hazards were investigated. The primary results indicate that cultivating rice with reclaimed wastewater irrigation did not cause a problem to adverse effects on crop growth and yields. Overall, wastewater could be used as a practical alternative measure for reclaimed wastewater irrigation. However, long-term monitoring is recommended on the effects on soil chemical characteristics and its related health concerns.

시설용량을 초과하는 폐수량의 유입확률 분석을 위한 극치분포모델의 적용에 관한 연구 (A study on the application of the extreme value distribution model for analysis of probability of exceeding the facility capacity)

  • 최성현;유순유;박태욱;박규홍
    • 상하수도학회지
    • /
    • 제30권4호
    • /
    • pp.369-379
    • /
    • 2016
  • It was confirmed that the extreme value distribution model applies to probability of exceeding more than once a day monthly the facility capacities using data of daily maximum inflow rate for 7 wastewater treatment plant. The result of applying the extreme value model, A, D, E wastewater treatment plant has a problem compared to B, C, F, G wastewater treatment plant. but all the wastewater treatment plant has a problem except C, F wastewater treatment plant based 80% of facility capacity. In conclusion, if you make a standard in statistical aspects probability exceeding more than once a day monthly can be 'exceed day is less than a few times annually' or 'probability of exceeding more than once a day monthly is less than what percent'.

활성슬러지 폐수처리장 진단 소프트웨어 (Diagnostic Software for Wastewater Treatment Plant using Activated-Sludge Process)

  • 손건태;이재은
    • 한국환경과학회지
    • /
    • 제8권5호
    • /
    • pp.611-616
    • /
    • 1999
  • The diagnostic software for the wastewater treatment plant using activated-sluge process is developed in order to increase the efficiency of management of the wastewater treatment plant. This software is based on the expert system and the visualized user interface, including the diagnosis of quantitative and qualitative data. For the generalization of this software, the initialization of each unit process and updating the files can be possible.

  • PDF

전처리 MF의 다양한 역세 공정을 적용한 하수재이용 파일럿 플랜트 연구 (Study of MF membrane as pretreatment option using various backwash process from wastewater reuse pilot plant)

  • 박광덕;박찬수;이창규;김종오;최준석
    • 상하수도학회지
    • /
    • 제30권3호
    • /
    • pp.335-341
    • /
    • 2016
  • Various studies have forwarded an outstanding wastewater effluent treatment systems toward securing sustainable supply of water sources. In this paper, a broad overview of the performance of MF membrane as pretreatment option for wastewater reuse will be presented based on the literature survey and experiments conducted over the wastewater reuse pilot plant. The pilot plant was operated with a continuous data acquisition for about 300days under various chemical enhanced backwash (CEB) system with subsequent treated water quality analysis. Accordingly, assessment of the effluent revealed that the pretreated water is suitable enough to be used as an input for Reverse Osmosis (RO) unit and significant effect of CEB and concentration of NaOCl is also conceived from the analysis. Moreover, it's also observed that the application of various CEB condition over long operational hours induced a constant declination of overall performance of MF membrane.

하수처리장 운영의 최적화를 위한 ASM, PHOENICS의 적용 (Application of ASM and PHOENICS for Optimal Operation of Wastewater Treatment Plant)

  • 김준현;한미덕;한영한
    • 산업기술연구
    • /
    • 제20권A호
    • /
    • pp.73-82
    • /
    • 2000
  • This study was implemented to find an optimal model for wastewater treatment processes using PHOENICS(Parabolic, hyperbolic or Elliptic Numerical Integration Code Series) and ASM(Activated Sludge Model). PHOENICS is a general software based upon the laws of physics and chemistry which govern the motion of fluids, the stresses and strains in solids, heat flow, diffusion, and chemical reaction. The wastewater flow and removal efficiency of particle in two phase system of a grit chamber in wastewater treatment plant were analyzed to inquire the predictive aspect of the operational model. ASM was developed for a biokinetic model based upon material balance in complex activated sludge systems, which can demonstrate dynamic and spatial behavior of biological treatment system. This model was applied to aeration tank and settling chamber in Choonchun city, and the modeling result shows dynamic transport in aeration tank. PHOENCS and ASM could be contributed for the optimal operation of wastewater treatment plant.

  • PDF

하수처리장 방류수를 이용한 소수력발전 성능분석 (Performance Anaysis of Small Hydropower Plant Using Treated Effluent in Wastewater Treatment Plant)

  • 이철형;박완순
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.494-497
    • /
    • 2012
  • A methodology to predict the output performance of small hydro power using treated effluent in wastewater treatment plant has been studied. Existing plant located Kyunggi-Do were selected and the output performance characteristics for these plants were analyzed. As a result, it was found that the developed model in this study can be used to analyze the output characteristics for small hydro power in wastewater treatment plant. Additionally, primary design specifications such as design flowrate, capacity, operational rate and annual electricity production were estimated and discussed.

  • PDF

농촌 지역에서 유입 유량이 소규모 하수처리장 처리 효율에 미치는 영향 (Effect of sewage flow on treatment efficiency of small scale wastewater treatment plant in rural community)

  • 임지열;길경익
    • 한국습지학회지
    • /
    • 제18권3호
    • /
    • pp.267-274
    • /
    • 2016
  • 농촌 지역 하수도 보급은 하천, 호소 및 습지와 같은 수계 수질 보호를 위해서 반드시 필요하다. 또한 안정적인 소규모 하수처리장 운영을 위해서는 유입 유량과 농도의 변화가 큰 소규모 하수도 특성을 고려해야 한다. 본 연구에서는 봉화군 18개의 소규모 하수처리장 운전 결과를 통해 유입유량비 (유입 유량 / 설계 유량) 특성, 소규모 하수처리장 처리 효율에 미치는 영향과 적정 유입유량비 산정에 관한 연구를 수행하였다. 분석 결과 유입유량비는 여름철에 가장 높은 것으로 나타난 반면, 유입 하수 농도는 가을철과 겨울철에 높은 것으로 나타났다. 유입유량비가 증가할수록 처리 효율이 증가하는 경향을 보였으며, 영양염류 처리 효율이 유기물과 부유물질 처리 효율에 비해 민감한 영향을 받는 것으로 나타났다. 안정적인 소규모 하수처리장 처리 효율을 위해서는 유입유량비 0.8 이상을 유지해야 할 것으로 판단된다.

섬유 형태에 따른 염색폐수 배출특성 연구 (Studies on the Effluent Characteristics of Dyeing Wastewater by Textile Classification)

  • 이수형;박정민;박상정;정제호
    • 한국물환경학회지
    • /
    • 제23권6호
    • /
    • pp.881-888
    • /
    • 2007
  • In order to investigate the characteristics of the non-biodegradable material, the $BOD_5/COD_{Cr}$ ratio was used. The average ratio of industrial complex's influent wastewater was 2.29~2.96, the effluent ratio was 4.29~19.0. The removal efficiency of $UV_{254}$ by physicochemical treatment was 22.8~94.7% and 5.3~77.2% by biological treatment, respectively. Of the wastewater removal efficiency for each of the items, the $BOD_5$ treatment efficiency was the greatest at 97.3% and the color & TN treatment efficiency was 40~70%. The study of the economical assessment showed that the complex as well as the individual companies spent 722~1,298 won for each ton of treated wastewater. All of the wastewater treatment facilities spent the most money on chemicals needed to treat the wastewater. The total cost for Nylon manufacturing wastewater treatment plant was the greatest while the total cost for cotton manufacturing wastewater treatment plant turned out to the lowest. As respects of removal efficiency and economocal assessment, Polyester A and Cotton manufacturing wastewater treatment plants were better effective than a dyeing industrial complex wastewater treatment plant.

냉연공장 도금공정에서 발생되는 폐수의 효율적인 미생물 처리에 관한 연구 (Effective Treatment of Wastewater from the Electroplating Plant of Cold-mill by using Microorganism)

  • 김상식;김형진
    • 공업화학
    • /
    • 제20권3호
    • /
    • pp.301-306
    • /
    • 2009
  • 본 연구에서는 냉연도금공장의 각 단위공정에서 발생되는 폐수를 미생물을 이용하여 안정하게 처리하기 위하여 각 폐수의 특성파악과 처리조건을 도출하고자 하였다. 발생되는 폐수 중 알칼리성폐수가 전체폐수의 64%를 차지하였으며, 산중금속함유폐수는 30%를 차지했다. 탈류폐액의 COD는 53890 mg/L로 전체 폐수발생량의 0.03%에 불과함에도 불구하고 COD의 53%를 유발하고 있었으며, COD의 94%는 SCN에 의해 기인하였다. 혼합폐수를 미생물로 처리할 때 혼합폐수 중 SCN농도가 200 mg/L 이하일 때 제거가 용이하였다. 반면 COD 유발물질은 400 mg/L 이하가 되더라도 처리효율이 미흡하였다. 이는 탈류폐액 중에는 난분해성 유기물질이 다량 함유되어 있기 때문이라 판단된다. 혼합폐수를 처리할 때 초기에 pH가 7.33이었지만 8 h 후에는 7.99로 상승하였다. 이는 탈류폐액에 함유된 SCN이 박테리아에 의해 분해될 때 발생되는 암모니아에 의해 기인한 것으로 사료된다.