• Title/Summary/Keyword: plant transfer

Search Result 933, Processing Time 0.021 seconds

Numerical investigation of film boiling heat transfer on the horizontal surface in an oscillating system with low frequencies

  • An, Young Seock;Kim, Byoung Jae
    • Nuclear Engineering and Technology
    • /
    • v.52 no.5
    • /
    • pp.918-924
    • /
    • 2020
  • Film boiling is of great importance in nuclear safety as it directly influences the integrity of nuclear fuel in case of accidents involving loss of coolant. Recently, nuclear power plant safety under earthquake conditions has received much attention. However, to the best of our knowledge, there are no existing studies reporting film boiling in an oscillating system. Most previous studies for film boiling were performed on stationary systems. In this study, numerical simulations were performed for saturated film boiling of water on a horizontal surface under low frequencies to investigate the effect of system oscillation on film boiling heat transfer. A coupled level-set and volume-of-fluid method was used to track the interface between the vapor and liquid phases. With a fixed oscillation amplitude, overall, heat transfer decreases with oscillation frequency. However, there is a frequency region in which heat transfer remains nearly constant. This lock-on phenomenon occurs when the oscillation frequency is near the natural bubble release frequency. With a fixed oscillation frequency, heat transfer decreases with oscillation amplitude. With a fixed maximum amplitude of the additional gravity, heat transfer is affected little by the combination of oscillation amplitude and frequency.

Evaluation of horizontal gene transfer from genetically modified zoysiagrass to the indigenous microorganisms in isolated GMO field (GMO 격리포장에서의 유전자변형 들잔디로부터 토착미생물로의 수평유전자전달 평가)

  • Bae, Tae-Wung;Lee, Hyo-Yeon;Ryu, Ki-Hyun;Lee, Tae-Hyeong;Lim, Pyung-Ok;Yoon, Pill-Yong;Park, Sin-Young;Riu, Key-Zung;Song, Pill-Soon;Lee, Yong-Eok
    • Journal of Plant Biotechnology
    • /
    • v.34 no.1
    • /
    • pp.75-80
    • /
    • 2007
  • The release of genetically modified organisms ($GMO_{s}$) into the environment has the potential risks regarding the possibility of gene transfer from $GMO_{s}$ to natural organisms and this needs to be evaluated. This study was conducted to monitor the possible horizontal gene transfer from herbicide-resistant zoysiagrass (Zoysia japonica Steud.) to indigenous microorganisms. We have first examined the effect of field-released GM zoysiagrass on the microbial flora in the gut of locust (Locusts mlgratoria). The microbial flora was analyzed through determining the 165 rDHA sequences of microorganisms. The comparison of the microbial flora in the gut of locusts that were captured at the field of GM zoysiagrass and of wild-type revealed that there is no noticeable difference between these two groups. This result indicates that the GM zoysiagrass does not have negative impact on microbial flora in the gut of locust. We then investigated whether the horizontal gene transfer occurred from GM zoysiagrass to microbes in soil, rhizosphere and faecal pellets from locusts by utilizing molecular tools such as Southern hybridization and polymerase chain reaction (PCR). When the total DNAs isolated from microbes in GM zoysiagrass and in wild-type zoysiagrass fields were hybridized with probes for bar or hpt gene, no hybridization signal was detected from both field isolates, while the probes were hybridized with DNA from the positive control. Absence of these genes in the FNAs of soil microorganisms as well as microbes in the gut of locust was further confirmed by PCR. Taken together, our data showed that horizontal gene transfer did not occur in this system. These results further indicate that frequencies of transfer of engineered plant DNA to bacteria are likely to be negligible.

Assessment of future stream flow and water quality of Man-gyeong river watershed based on extreme climate change scenarios and inter-basin water transfer change using SWAT (SWAT을 이용한 극한 기후변화 시나리오와 유역간 물이동 변화를 고려한 만경강 유역의 미래 수문 및 수질 평가)

  • Woo, So-Young;Lee, Ji-Wan;Kim, Yong-Won;Kim, Seong-Joon
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.8
    • /
    • pp.605-616
    • /
    • 2020
  • The purpose of this study is to assess the future hydrological and water quality change of Man-gyeong river basin (1,602 ㎢) based on future extreme climate change scenarios and reduction of inter-basin water transfer amount using SWAT (Soil and Water Assessment Tool). The SWAT was calibrated (2012~2014) and validated (2016~2018) at 2 water level observation stations (DC, JJ) and 2 water quality observation stations (SR, GJ) considering inter-basin water transfer amount, stream water withdrawal, and point source data. For the streamflow, the coefficient of determination (R2) was 0.70 and the average Nash-Sutcliffe efficiency (NSE) was 0.51 respectively. For the water quality of SS, T-N, and T-P, the R2 was 0.72, 0.80 and 0.72 respectively. The future average streamflow under climate change scenarios increased up to 459 mm/yr, and average SS, T-N and T-P yields also increased up to 19,548 ton/yr, 68,748 kg/yr, and 13,728 kg/yr respectively. When the amount of inter basin water transfer decreased, the streamflow especially decreased in spring and winter periods, and the future water quality yields increased under the influence of precipitation. In order to solve the deterioration of water quality due to decrease in the flow rate and an increase in the load, the amount of inter basin water transfer should be maintained to a certain level.

A Note on Relay Feedback Identification Under Static Load Disturbances

  • Kaya, Ibrahim
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.395-400
    • /
    • 2015
  • Obtaining the parameters for PID controllers based on limit cycle information for the process in a relay controlled feedback loop has become an accepted practical procedure. If the form of the plant transfer function is known, exact expressions for the limit cycle frequency and amplitude can be derived so that their measurements, assumed error free, can be used to calculate the true parameter value. In the literature, parameter estimation for an assumed form of the plant transfer function has generally been considered for disturbance free cases, except a recently published work of the author. In this paper additional simulation results are reported on exact parameter estimation from relay autotuning under static load disturbances.

Modeling of the Drying Process in Paper Plants

  • Hwang, Ki-Seok;Yeo, Yeong-Koo;Lee, Yeong-Jun;Kang, Hong
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2003.11a
    • /
    • pp.272-290
    • /
    • 2003
  • In this study a model for the drying process in paper production plants was developed based on the mass and heat balances around drying cycles. Relationships for the heat transfer coefficients between the web and the air as well as between the drying cylinder and the web were extracted from the closed-loop plant operation data. It was found that the heat transfer coefficients could be represented effectively in terms of moisture content, basis weight and reel velocity. The effectiveness of the proposed model was illustrated through numerical simulations. From the comparison with the operation data, the proposed model represents the paper plant being considered with sufficient accuracy.

  • PDF

Cloning of Epidermis-specific cDNAS Encoding a Lipid Transfer Protein and an Aldehyde Decarbonylase from Senecio odorus

  • Pyee, Jaeho
    • Journal of Plant Biology
    • /
    • v.39 no.3
    • /
    • pp.189-195
    • /
    • 1996
  • The major cuticular components have been shown to be synthesized in the epidermis. Therefore, cloning of epidermis-specific genes could yield information to be used to isolate and characterize the enzymes involved in the cuticle biosynthesis. A subtractive cDNA library was prepared from Senecio odorus in which epidermis-specific cDNAs were enriched. Differential screening of the library using epidermal and non-epidermal probes revealed two cDNAs. One of them designated epi425 was identified, based on the sequence homology, as a member of a new class in the LTP gene family and the other clone designated epi23 as a gene encoding an aldehyde decarbonylase. Northern blot analyses showed that epi425 and epi23 cDNAs hybridized with a transcript of about 600 and 2, 100 nucleotides, respectively, from the epidermis but not from the non-epidermal tissues. Further characterization of these clones will provide more information on the mechanism of the cuticle biosynthesis.

  • PDF

Consideration for Heat Exchanger Performance Evaluation with reduced spend fuel pool heat due to the long-term over-haul maintenance (장기 예방정비로 인한 사용후연료저장조 열원 감소가 열교환기 성능평가에 미치는 영향 고찰)

  • Park, Chan;Lee, Sung Ho
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.16 no.1
    • /
    • pp.56-64
    • /
    • 2020
  • The safety related heat exchangers have been evaluated for their performance during the operation of the nuclear power plant. The evaluation program for the safety related heat exchanger was developed in 2010 and used by KHNP based on EPRI TR-10739 algorithms. The spend fuel pool heat exchanger is one of the safety related heat exchanger in the nuclear power plant and also evaluated for their performance. Recently the performance evaluation for the spend fuel pool heat exchanger was not available because of the decreased heat in the spend fuel pool due to the long term overhaul. This paper analyzes the main cause of evaluation failure in the evaluation process and suggests the criteria for the heat exchanger performance evaluation during the long term overhaul.

Influence on heat transfer due to uneven flow (유동 불균일이 전열관 튜브에 미치는 영향)

  • Chong, Chae-Hon;Song, Jung-Il
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.273-279
    • /
    • 2008
  • The purpose of this study is not only to evaluate thermal performance but also to find the stress behavior of heat transfer tubes under the part load operation in Heat Recovery Steam Generator. Flow analysis was performed to know the behavior of exhaust gas from gas turbine and thermal performance was calculated using distribution of hot exhaust velocity. In addition, tubes temperature during operation were gathered from actual plant to verify the uneven flow distribution under part load operation. Stress analysis was performed using tubes temperature data gathered from actual plant under both part and full load operations to know the stress behavior of tubes.

  • PDF

Transfer of Potato Virus Y (Necrotic strain) Resistance from Nicotiana africana to Nicotiana tabacum (Nicotiana Tabacum과 Nicotiana africana의 종간교배에 의한 감자바이러스 Y 저항성 유전자원 개발)

  • 금완수;정윤화;최상주;조명조;이승철
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.16 no.2
    • /
    • pp.102-107
    • /
    • 1994
  • This study was conducted to transfer the potato virus Y-necrosis strain resistance from Nicotiana africana to Nicotiana tabacum (cv. NC82) N. africana was crossed with NC82, GErmination of the cotyledon stage, at which time most of the seedling died. However, surviving seedlings continued to grow normally. Chromosomes of the these interspecific self-sterile F1 hybrids were doubled by tissue culture. Amphidiploid of F1 hybrid was self-fertile. Starting with amphidipliod, a wystematic backcross (BC) program was set up with NC82 as recurrent parent. In the BC5C2 generation, the resistant plant was selected. This resistant line, KF8833-1, had 48 chromosome and secreting glandular trichomes. It flowered 2days later than NC82, and stalk height, leaves per plant, leaf length and leaf width were similar to those of NC82.

  • PDF

Thermal Stress Analysis for Life Prediction of Power Plant Turbine Rotor (발전용 터빈 로우터의 수명예측을 위한 열응력 해석)

  • 임종순;허승진;이규봉;유영면
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.2
    • /
    • pp.276-287
    • /
    • 1990
  • In this paper research result of transient thermal stress analysis of power plant turbine rotors for life prediction under severs operating conditions is presented. Galerkin's recurrence scheme is used for numerical solution of discretized FEM equation of transient heat conduction equation. Boundary conditions for the equation and operating conditions are intensively investigated for accurate life prediction of turbine rotors in operation. A computer program for on-site application is developed and tested. Distribution of thermal stress in turbine rotors during various operating condition is analyzed with the program and it is found that the peak thermal stress appears during cold stage conditions at the first stage of high pressure rotors.