• Title/Summary/Keyword: plant construction

Search Result 2,246, Processing Time 0.028 seconds

Analysis of Time-Series data According to Water Reduce Ratio and Temperature and Humidity Changes Affecting the Decrease in Compressive Strength of Concrete Using the SARIMA Model

  • Kim, Joon-Yong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.10
    • /
    • pp.123-130
    • /
    • 2022
  • In this paper is one of the measures to prevent concrete collapse accidents at construction sites in advance. Analyzed based on accumulated Meteorological Agency data. It is a reliable model that confirms the prediction of the decrease rate occurrence interval, and the verification items such as p_value is 0.5 or less and ecof appears in one direction through the SARIMA model, which is suitable for regular and clear time series data models, ensure reliability. Significant results were obtained. As a result of analyzing the temperature change by time zone and the water reduce ratio by section using the data secured based on such trust, the water reduce ratio is the highest in the 29-31 ℃ section from 12:00 to 13:00 from July to August. found to show. If a factor in the research result interval occurs using the research results, it is expected that the batch plant will produce Ready-mixed concrete that reflects the water reduce ratio at the time of designing the water-cement mixture, and prevent the decrease in concrete compressive strength due to the water reduce ratio.

Feasibility study on the design of DC HTS cable core

  • Sim, Ki-Deok;Kim, Seok-Ho;Jang, Hyun-Man;Lee, Su-Kil;Won, Young-Jin;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.4
    • /
    • pp.24-30
    • /
    • 2010
  • The renewable energy source is considered as a good measure to cope with the global warming problem and the fossil energy exhaustion. The construction of electric power plant such as an offshore wind farm is rapidly increasing and this trend is expected to be continued during this century. The bulky and long distance power transmission media is essential to support and promote the sustainable expansion of renewable energy source. DC power cable is generally considered as the best solution and the demand for DC electric power has been rapidly increasing. Especially, the high temperature superconducting (HTS) DC cable system begins to make a mark because of its advantages of huge power transmission capacity, low transmission loss and other environmental friendly aspects. Technical contents of DC HTS cable system are very similar to those of AC HTS cable system. However the DC HTS cable can be operated near its critical current if the heat generation is insignificant, while the operating current of AC HTS cable is generally selected at about 50~70% of the critical current because of AC loss. We chose the specifications of the cable core of 'Tres Amigas' project as an example for our study and investigated the heat generation when the DC HTS cable operated near the critical current by some electric and thermal analyses. In this paper, we listed some technical issues on the design of the DC HTS cable core and described the process of the cable core design. And the results of examination on the current capacity, heat generation, harmonic loss and current distribution properties of the DC HTS cable are introduced.

Improved Operation Criteria for a Power Generation Gas Turbine on the Blade Path Temperature Variations (날개통과온도 변화에 기반한 발전용 가스터빈의 운전관리 개선)

  • Yong-Il Lee;Jae-Heon Lee
    • Plant Journal
    • /
    • v.18 no.4
    • /
    • pp.48-57
    • /
    • 2023
  • In this study, I discussed a way of the improved operation criteria to detect combustion instability in advance F-Class Gas Turbine, which adopts lean pre-mixed combustion system. The data of 16 blades path temperature thermocouple installed radially at the gas Turbine exit were collected to analyze the variation of individual blade path temperature. The cumulative variation in individual blade path temperature for one week under normal combustion conditions was confirmed to be up to 26℃. On the other hand, in the event of combustion instability, the symptoms of increased temperature variations in the individual thermocouple were mostly seen from a few days ago. Based on the results of this study, it is deemed appropriate to inspect and maintain in Ulsan Thermal Power Gas Turbine when the individual blade path temperature exceeds 50℃ of the cumulative variation for 10 days.

  • PDF

Estimation of Unsaturated Permeability Function from Water Retention Characteristics for Korean Weathered Soils (함수특성에 근거한 국내 풍화토의 불포화 투수곡선 추정)

  • Kim, Yun-Ki;Choi, Kyung-Lim;Lee, Sung-Jin;Lee, Seung-Rae;Kwon, Hyoung-Seok
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.10
    • /
    • pp.49-60
    • /
    • 2010
  • Unsaturated permeability function is an important factor in the design and analysis of various unsaturated soil structures. Generally the permeability characteristics decrease as the mat ric suction increases and the trend is similar to water retention characteristics of a soil. The permeability of unsaturated soils can be obtained directly by laboratory tests or indirectly by estimation methods from other soil properties. For unsaturated soils sampled from 7 areas in KOREA, SWCCs and unsaturated permeability functions were obtained by experimental tests. The unsaturated permeability results were also compared with the unsaturated permeability functions derived from the SWCCs theoretically. However, the current estimation models of unsaturated permeability function did not express the unsaturated permeability characteristics. Therefore, the FXK-M permeability function was modified to predict more accurate permeability functions for Korean weathered soils using a correction factor that can be calculated from the air-entry value of SWCC. The new estimation model resulted in good agreements for all tested soils.

Evaluation on the Effect of Coal-ash as Landfill Cover Material of Mono-Layer Cover System through the Field Scale Test (현장 실험을 통한 단층형 매립복토시스템의 복토재로서 석탄회의 효과 검토)

  • Yun, Sung-Wook;Kang, Sin-Il;Jin, Hae-Geun;Kim, Pil-Joo;Kim, Soon-Oh;Yu, Chan
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.7
    • /
    • pp.81-91
    • /
    • 2010
  • In order to investigate the applicability and suitability of the coal ash (bottom ash) to landfill final cover, field pilot-scale lysimeter experiments were carried out. The mixture of loamy soil, bottom ash, and construction waste was placed as a cover material in lysimeter ($2m{\times}6m{\times}1.2m$) which were constructed with cement brick, and then volumetric water contents, pF value, and the quantity of runoff and seepage of treatment boxes filled with the mixture of loamy soil and the industrial by-products were monitored from July, 2007 to february, 2008. Among the cases tested, consequently, the case containing the mixture of bottom ash and loamy soil was most effective in plant growth and water retention ability.

Investigation of Ground Remote Sensing Technique Using CCD Camera (CCD 카메라를 이용한 지상원격탐사 기술 개발)

  • Kim, Eung Nam
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.2D
    • /
    • pp.325-333
    • /
    • 2006
  • Recently, in the case of observing the global environment, satellite remote sensing technology has been important. It's because satellite remote sensing is valuable for assessing relatively large areas. But now, small scale remote sensing techniques are needed which can be applicable to the detail investigation of plant tree areas which afforest land after the large scale construction of roads, dams and airports. In this study, we tried to develop and propose a lower altitude sensing technique which can be used in ground remote sensing by using a CCD camera. As a result of this investigation the following can be concluded: We recognized the transference characteristics of filters which were used in comparative tests about the four ground remote sensing devices. We also found that the near-IR camera could be used for an imaging spectral radiometer in the extraction of the vegetation index. Furthermore, we found that the vegetation index has varied hour by hour during the day of the experiment. Finally, we brought about an increase phase of the NDVI in a forest fire, which caused considerable damage, by developing new ground remote sensing technology.

Evaluation of Genetic Characteristics and Essential oil Composition of Coriander (Coriandrum sativum L.)

  • Tae Hee Kim;Song Mun Kim;Ki Yeon Lee;Kyung Dae Kim;Jae Hee Lee;Eun Ha Jang;Jin Gwan Ham
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2022.10a
    • /
    • pp.320-320
    • /
    • 2022
  • Coriander(Coriandrum sativum L.) belongs to the family Umbelliferae/Apiaceae. It is cultivated as a spice and medicinal herb around the world, including its leaves and seeds. Coriander leaves have soft and fragrant, so they can be used in cuisines such as China, Mexico, and, Southeast Asia. Coriander leaves contain a high amount of vitamin C, carotene, and multiple polyphenols. Coriander essential oils and extracts have various chemical components and are known to have antioxidant, antibacterial, and antifungal activities. This study was carried out for resource discovery, propagation, and DB construction of aromatic plants. In order to evaluate the genetic characteristics, 30 kinds of Coriander seeds were supplied from the Center for Genetic Resources. The evaluation of characteristics of the basal part leaf number, leaf shape, and plant height was investigated. Also, Essential oils extract from various parts of plants including the leaves, flowers, and steam isolated by simultaneous distillation extraction(SDE) apparatus. In the results, heights showed growing to 70 cm over and basal part leaf number 0 to7. The leaves are variable, they are measured according to leaves incisions, and most of the included incision. The qualitative analysis of EOs was performed using gas chromatography-mass spectrometry. EOs had various chemical compositions. Major compounds were trans-2-Decenal, linalool, decanal, 2-Dodecenal, 13-Tetradecanal, 2-Undecenal.

  • PDF

Service life evaluation of HPC with increasing surface chlorides from field data in different sea conditions

  • Jong-Suk Lee;Keun-Hyeok Yang;Yong-Sik Yoon;Jin-Won Nam;Seug-Jun Kwon
    • Advances in concrete construction
    • /
    • v.16 no.3
    • /
    • pp.155-167
    • /
    • 2023
  • The penetrated chloride in concrete has different behavior with mix proportions and local exposure conditions, even in the same environments, so that it is very important to quantify surface chloride contents for durability design. As well known, the surface chloride content which is a key parameter like external loading in structural safety design increases with exposure period. In this study, concrete samples containing OPC (Ordinary Portland Cement), GGBFS (Ground Granulated Blast Furnace Slag), and FA (Fly Ash) had been exposed to submerged, tidal, and splash area for 5 years, then the surface chloride contents changing with exposure period were evaluated. The surface chloride contents were obtained from the chloride profile based on the Fick's 2nd Law, and the regression analysis for them was performed with exponential and square root function. After exposure period of 5 years in submerged and tidal area conditions, the surface chloride content of OPC concrete increased to 6.4 kg/m3 - 7.3 kg/m3, and the surface chloride content of GGBFS concrete was evaluated as 7.3 kg/m3 - 11.5 kg/m3. In the higher replacement ratio of GGBFS, the higher surface chloride contents were evaluated. The surface chloride content in FA concrete showed a range of 6.7 kg/m3 to 9.9 kg/m3, which was the intermediate level of OPC and GGBFS concrete. In the case of splash area, the surface chloride contents in all specimens were from 0.59 kg/m3 to 0.75 kg/m3, which was the lowest of all exposure conditions. Experimental constants available for durability design of chloride ingress were derived through regression analysis over exposure period. In the concrete with GGBFS replacement ratio of 50%, the increase rate of surface chloride contents decreased rapidly as the water to binder ratio increased.

Economics and Ground Cover Growth Characteristics of a New Method of Shallow Soil Artificial Foundation Planting (저토심 인공지반 녹화공법의 경제성 및 도입 가능한 지피식물의 생육특성)

  • Choi, Jin-Woo;Kim, Hag-Kee;Lee, Kyong-Jae;Kang, Hyun-Kyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.5
    • /
    • pp.98-108
    • /
    • 2009
  • The purpose of this study is to analyze the characteristics of limited methods, economics and breeding appropriateness of native and imported ground cover plants in the methodology of a shallow soil rooftop garden. The new shallow soil rooftop gardening method uses a total of 13cm in soil thickness, including 4.5cm of top soil on a 7.5cm rock-wool-mat stacked onto a 1cm roll-type-draining plate. The total construction cost for each method of soil level within the design price standard for SEDUM BLOCK is 89,433won/$m^2$, and for DAKU is 92,550won/$m^2$. By comparing those two methods, the construction cost of the shallow soil artificial foundation methodology is 45,000won/$m^2$; this shows the new method is 50% less expensive than the existing method of shallow soil rooftop gardening. The experiment was executed on the rooftop of the Korean National Housing Corporation to ensure validity of the shallow soil artificial foundation planting, and the sample plants which were imported and grown now in native covering. A list investigating the growing plants was made of the cover rate in each plant class, both while alive and the dry plant weight. The native ground cover plants, Sedum kamtschaticum, Sedum middendorffianum, Allium senescens, Sedum sarmentosum, Aquilegia buergariana, and Caryopteris incana increased the cover rate, live weight and dry weight in the shallow soil artificial foundation method. Among the imported cover plants, Sedum sprium and Sedum reflexum, the cover rate increased and growth conditions improved. However, some species needed weed maintenance. After examination with the less expensive shallow soil artificial foundation method and growth analysis, it was found that rooftop gardens are a low-cost option and the growth of plants is great. This result shows the new method can contribute to the proliferation of rooftop gardens in urban settings.

Construction of cDNA Library for Using Virus-induced Gene Silencing (VIGS) Vector with the Sweetpotato Whitefly, Bemisia tabaci(Hemiptera: Aleyrodidae) (담배가루이(Bemisia tabaci, Aleyrodidae, Hemiptera)에서 Virus-induced Gene Silencing (VIGS) Vector를 이용하기 위한 cDNA Library 제작)

  • Ko, Na Yeon;Lim, Hyoun Sub;Yu, Yong Man;Youn, Young Nam
    • Korean journal of applied entomology
    • /
    • v.54 no.2
    • /
    • pp.91-97
    • /
    • 2015
  • The sweetpotato whitefly, Bemisia tabaci, is the major insect pest that transmitted over 100 plant viruses including tomato yellow leaf curl virus (TYLCV) of tomato plant as virus vector in the world. In this study, cDNA library of whitefly was constructed using Gateway system for selecting target gene in order to control of B. tabaci using virus-induced gene silencing (VIGS) vector with RNAi. First of all, when using oligo d(T) rimer, the calculated titer of cDNA library was confirmed with $1.4{\times}10^4$ clones and average insert sizes was confirmed with 1 kb. However, insert size was very big for construction of cDNA. Otherwise, when using attB-N25 random primer and sonication for 6 sec, the calculated titer of cDNA library was confirmed with $1.04{\times}10^5$ clones. But mostly insert band wasn't identified on the electrophoresis, because it seemed that insert size is too small (${\leq}100bp$), also the size of identified insert was somewhat big. Finally, when using oligo d(T) primer and sonication for 1 sec, cDNA insert of whitefly was appropriated for VIGS with 300-600 bp. However, cDNA sequence included a poly A and titer was very low to $5.2{\times}10^2$ clones. It was supposed that heat shock transformation was used instead of electro-transformation. It is considered that when constructing cDNA library for using VIGS vector, (1) random primer should be used for First strand cDNA synthesis in order to remove poly A and (2) sonication for 1 sec should be performed in order to get appropriated insert size and (3) electro-transformation should be performed in order to improve transformation efficiency.