• Title/Summary/Keyword: plant's noise

Search Result 114, Processing Time 0.041 seconds

A Study of Axial Vibration of Two Stroke Low Speed Diesel Engine on the Diesel Power Plant (육상 디젤 발전소용 저속 2행정 디젤엔진의 종진동에 관한 연구)

  • 이돈출;남정길;고재용
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.11 no.9
    • /
    • pp.398-405
    • /
    • 2001
  • The maximum and mean indicated pressure of two stroke low speed diesel engine has been continuously increased with a view of increasing engine power and also reducing fuel consumption. As a result, axial excitation has been increased comparing to that of the previous one. So the axial vibration damper in standard one is applied to all two stroke low speed diesel engine at the free end of crankshaft. Though many studies were carried out for marine use, few has been made for diesel power plant because there was little demand for power plant. Nowadays, diesel engine is much to be used for many benefits. In this paper, the optimum design of axial vibration on the 65 kW diesel power plant with tow 9K80MC-S engines of 9 cylinders was carried out. And the axial-torsional coupled vibration of this shafting system is identified by theoretical analysis and vibration measurement.

  • PDF

Prediction of the Noise Levels for a Plant (공장 소음도 예측)

  • 윤세철;김태구;오종민
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.3
    • /
    • pp.88-95
    • /
    • 2000
  • The level of noise produced by machinery and its arrangement insides a factory is indicated to be a maximum of 96.1 dB(A). The maximum level of noise from a commoner's house outside the factory is shown to be 62.9 dB(A), which exceeds 60 dB(A), the permitted limit of noise level in a time period of day. us study has predicted the level of noise reduction according to a step by step prevention plan by considering the characteristics of the causes of noise, the permitted limit of noise levels, problems and economical efficiency attendant upon the noise prevention measures. Establishing target levels of noise each of the three steps of the noise prevention plan. The predicted level of noise at the place of a commoner's house in accordance with the first step is 50.0 - 59.0 dB(A), and can satisfy the permitted limit of noise in a time period of the day. In taking prevention measures for the second step, the noise level is 50.7 - 53.6 dB(A) which is less than 55 dB(A) in a time period of the evening, the permitted limit of noise in a time period of night., and it can meet 47.4 - 50.3 dB(A) in the third step.

  • PDF

A study of Axial Vibration of Two Stroke Low Speed Diesel Engine On the Diesel Power Plant (육상 디젤 발전소용 저속 2행정 디젤엔진의 종진동에 관한 연구)

  • Lee, D.C.;Ko, J.Y.;Yu, J.D.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1816-1822
    • /
    • 2000
  • The maximum and mean indicated pressure of two stroke low speed diesel engine has been continuously increased with a view of increasing engine power and also reducing fuel consumption. As a result, axial excitation has been highed comparing to that of the previous and so in standard axial vibration damper is applied to all two stroke low speed diesel engine at the free end of crankshaft. Though many studies were carried out for marine use, few has been made for diesel power plant because there was little demand for power plant. Nowadays, diesel engine is much to be used for many benefits and so in this paper, the optimum design of axial vibration on the 65 MW diesel power plant with 9K80MC-S engine was carried out. And the axial-torsional coupled vibration of this shafting system is identified by theoretical analysis and vibration measurement.

  • PDF

Investigation on the Excessive Vibration of A Mixer Facility in A Water Purification Plant (정수장용 교반기 시설의 과진동 원인 분석)

  • Park, Jin-Ho;Lee, Jeong-Han;Kim, Bong-Soo;Kang, Mun-Hu;Kim, Dong-Soo;Joo, Yoon-Sik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.312-316
    • /
    • 2002
  • Recently, mixers are being widely used in the water purification plant in order to increase the filtration efficiency. It has been found that a severe vibration was being felt on a upper structure of a mixer facility during steady state operation. The cause of the excessive vibration of the structure to which the mixer's shaft is supported has been evaluated through modal analysis on the shaft and vibration measurements during operation. The fundamental natural frequency of the mixer's shaft is found to be around 1.8 Hz and the main vibratory frequency around 30 Hz. It has been tuned out that the main vibratory frequency, 30 Hz is coincident with the fundamental holding frequency of the upper structure, and that the acceleration signal of the upper structure and the displacement signal of the mixer's shaft showed highly coherent to each other. Accordingly, it reveals that the main cause of the excessive vibration is due not to the mixer's vibration but to the natural frequency of the upper structure excited by flow turbulence.

  • PDF

A Study of Analysis on the Noise Aspect of School District -A Case Study of Wonju City- (학교주변 소음실태 분석에 관한 연구 -원주지역 학교를 중심으로-)

  • 가종길;이준대
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.3
    • /
    • pp.140-145
    • /
    • 1999
  • In this study, noise analyses were performed toward ten school and one library-building adjacent to road. In particular, noise levels measured in the case-study city were compared to those from environmental noise standard as well as to encouraged noise level. In the analyses, the following conclusions are emphasized in order to make comfortable educational learning environment. 1) When windows were open, the measured noise level of 9 schools exceeded the encouraged noise level. In order to mitigate the exceeded level, it is necessary to plant trees or lawn and install soundproofing wall. 2) When windows were closed, the measured noise level of the most schools showed lower than that of encouraged level. For sound insulation, installing both double window and casement window are required. 3) Schoolhouse's vertical arrangement from the road in order to minimize the expected noise effect, and provision of green space by which visual hiding as well as psychological comfort are presumably achieved.

  • PDF