• Title/Summary/Keyword: plane alignment

Search Result 183, Processing Time 0.023 seconds

A study on the machining accuracy of dental digital method focusing on dental inlay

  • Bae, Eun-Jeong;Jeong, Il-Do;Kim, Woong-Chul;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.321-327
    • /
    • 2018
  • PURPOSE. The purpose of this study was to compare the cutting method and the lamination method to investigate whether the CAD data of the proposed inlay shape are machined correctly. MATERIALS AND METHODS. The Mesial-Occlusal shape of the inlay was modeled by changing the stereolithography (STL). Each group used SLS (metal powder) or SLA (photocurable resin) in the additive method, and wax or zirconia in the subtractive method (n=10 per group, total n=40). Three-dimensional (3D) analysis program (Geomagic Control X inspection software; 3D systems) was used for the alignment and analysis. The root mean square (RMS) in the 2D plane state was measured within $50{\mu}m$ radius of eight comparison measuring points (CMP). Differences were analyzed using one-way analysis of variance and post-hoc Tukey's test were used (${\alpha}=.05$). RESULTS. There was a significant difference in RMS only in SLA and SLS of 2D section (P<.05). In CMP mean, CMP 4 ($-5.3{\pm}46.7{\mu}m$) had a value closest to 0, while CMP 6 ($20.1{\pm}42.4{\mu}m$) and CMP 1 ($-89.2{\pm}61.4{\mu}m$) had the greatest positive value and the greatest negative value, respectively. CONCLUSION. Since the errors obtained from the study do not exceed the clinically acceptable values, the lamination method and the cutting method can be used clinically.

Simulation of Tsunamis in the East Sea Using Dynamically-Interfaced Multi-Grid Model (동적결합둥지형 모형에 의한 동해안 쓰나미 시뮬레이션)

  • Choi, Byung-Ho;Efim, Pelinovsky;Woo, Seung-Buhm;Lee, Jong-Woong;Mun, Jong-Yoon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.1
    • /
    • pp.41-55
    • /
    • 2003
  • A dynamically-interfaced multi-grid finite difference model for simulation of tsunamis in the East Sea(Choi et al.) was established and further applied to produce detailed feature of coastal inundations along the whole eastern coast of Korea. The computational domain is composed of several sub-regions with different grid sizes connected in parallel of inclined directions with 16 innermost nested models. The innermost sub-region represents the coastal alignment reasonably well and has a grid size of about 30 meters. Numerical simulations have been performed in the framework of shallow-water equations(linear, as well as nonlinear) over the plane or spherical coordinate system, depending on the dimensions of the sub-region. Results of simulations show the general agreements with the observed data of run-up height for both tsunamis. The evolution of the distribution function of tsunami heights is studied numerically and it is shown that it tends to the log-normal curve for long distance from the source.

Vibration Characteristics of a Synchro Clutch Coupling for Steam Turbine (증기터빈용 Synchro Clutch Coupling의 진동 특성)

  • Shim, Eung-Gu;Lee, Tae-Gu;Moon, Seung-Jae;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.4 no.3
    • /
    • pp.66-72
    • /
    • 2008
  • The vibration of steam turbine is caused by Mass unbalance, Shaft misalignment, Oil whip and rubbing etc. But in turbine which is normally operated and maintained, the Mass unbalance component possesses the greatest portion. Our power plant has two steam turbines in capacity of 200 MW and 135 MW respectively and each turbine is supported by 6 journal bearings. However, we had many difficulties because the vibration amplitude of #3 and #4 Bearings was high during the start-up and operation mode change of steam turbine. But, with this study, we completely solved the vibration problem caused by the mass unbalance of #1 steam turbine. Until a recent date, #3 and #4 bearings which support high pressure turbine for #1 steam turbine had shown about $135{\mu}m$ in vibration amplitude (sometimes it increased to $221{\mu}m$ maximum. alarm: 6 mils, trip: 9 mils) at base load. After applying the study, they decreased to about $45{\mu}m$ maximum. It is a result from that we did not change the setting value of bearing alignment and only changed the assembly position of internal parts in Synchro clutch coupling rachet wheel which links between high pressure turbine and low pressure turbine, and increased the internal gap and machining of the Pawl cage surface. In the operation of steam turbine, if the vibration value increases by 1X, we should reduce the vibration of bearing by weight balancing. However, unless the vibration of bearing is declined by the balancing, we will have to disassemble and check the component and find the cause. In this study, we researched the way to lower mass unbalance that is 1X vibration component which has the greatest portion of vibration generated by steam turbine and we got good result by applying the findings of this study.

  • PDF

Implementation on the Portable Blood Gas Analyzer and Performance Estimation/A Study on the Hydrometer Calibration System using Image Processing (영상처리 기법을 이용한 부액계 자동 교정 시스템 구현)

  • Lee, Yong-Jae;Chang, Kyung-Ho;Oh, Chae-Youn;Jung, Sang-Duk
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.6
    • /
    • pp.258-264
    • /
    • 2003
  • The present paper studies how to calibrate hydrometer using image process. The method aligns particular scales of hydrometer selected for calibrating the hydrometer with the horizontal plane of the reference liquid automatically without man's operation. Major parts composing the system are CCD camera, frame grabber, stepping motor and image process program. The image process program is composed of a part that locates the meniscus and aligns it with a scale and a part that controls the step motor. To verify the performance of the developed method, this study compares the meniscus and scale observed directly with the naked eye with the result of calibration by the manual calibration method. The differences between the corrections were less than $0.004\;kg/m^3$ with uncertainty of $0.06\;kg/m^3$. These showed that the calibration results of the developed hydrometer calibration using image process nearly equal to manual method.

In-situ electron beam growth of $YBa_2Cu_3O_{7-x}$ coated conductors on metal substrates

  • Jo, W.;Ohnishi, T.;Huh, J.;Hammond, R.H.;Beasley, M.R.
    • Progress in Superconductivity
    • /
    • v.8 no.2
    • /
    • pp.175-180
    • /
    • 2007
  • High temperature superconductor $YBa_2Cu_3O_{7-x}$ (YBCO) films have been grown by in-situ electron beam evaporation on artificial metal tapes such as ion-beam assisted deposition (IBAD) and rolling assisted biaxially textured substrates (RABiTS). Deposition rate of the YBCO films is $10{\sim}100{\AA}/sec$. X-ray diffraction shows that the films are grown epitaxially but have inter-diffusion phases, like as $BaZrO_3\;or\;BaCeO_3$, at their interfaces between YBCO and yttrium-stabilized zirconia (YSZ) or $CeO_2$, respectively. Secondary ion mass spectroscopy depth profile of the films confirms diffused region between YBCO and the buffer layers, indicating that the growth temperature ($850{\sim}900^{\circ}C$) is high enough to cause diffusion of Zr and Ba. The films on both the substrates show four-fold symmetry of in-plane alignment but their width in the -scan is around $12{\sim}15^{\circ}$. Transmission electron microscopy shows an interesting interface layer of epitaxial CuO between YBCO and YSZ, of which growth origin may be related to liquid flukes of Ba-Cu-O. Resistivity vs temperature curves of the films on both substrates were measured. Resistivity at room temperature is between 300 and 500 cm, the extrapolated value of resistivity at 0 K is nearly zero, and superconducting transition temperature is $85{\sim}90K$. However, critical current density of the films is very low, ${\sim}10^3A/cm^2$. Cracking of the grains and high-growth-temperature induced reaction between YBCO and buffer layers are possible reasons for this low critical current density.

  • PDF

Characteristics of Particle Separation in Suspension using an Ultrasonic Standing Wave

  • Shin, Beom-Soo;Danao, Mary-Grace C.
    • Journal of Biosystems Engineering
    • /
    • v.37 no.2
    • /
    • pp.113-121
    • /
    • 2012
  • Purpose: Particle separation in solution is one of important process in a unit operation as well as in an extract preparation for biosensors. Contrary to centrifuge-type of mesh-type filter, using an ultrasonic standing wave make the filtering process continuous and free from maintenance. It is needed to investigate the characteristics of particle movement in the ultrasonic standing wave field. Methods: Through the computer simulation the effects of major design and driving parameters on the alignment characteristics of particles were investigated, and a cylindrical chamber with up-stream flow type was devised using two circular-shape PZTs on both sides of the chamber, one for transmitting ultrasonic wave and the other for just reflecting it. Then, the system performance was experimentally investigated as well. Results: The speed of a particle to reach pressure-node plane increased as the acoustic pressure and size of particle increased. The maximum allowable up-stream flow rate could be calculated as well. As expected, exact numbers of pressure-node planes were well formed at specific locations according to the wavelength of ultrasonic wave. As the driving frequency of PZT got close to its resonance frequency, the bands of particles were observed clearer, which meant the particles were trapped into narrower space. Higher excitation voltages to the PZT produced a greater acoustic force with which to trap particles in the pressure-node planes, so that the particles gathered could move upwards without disturbing their alignments even at a higher inlet flow rate. Conclusions: This research showed the feasibility of particle separation in solution in the continuous way by an ultrasonic standing wave. Further study is needed to develop a device to collect or harvest those separated particles.

A Review of Effects of Osteoarthritic Patient with a Varus Deformity of the Knee on Laterally Wedged Insole (외측 쐐기 깔창이 골관절염 환자의 내반슬에 미치는 영향에 관한 고찰)

  • Lee, Sang-Yong;Shin, Hyung-Soo;Bae, Sung-Soo
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.11 no.1
    • /
    • pp.65-73
    • /
    • 2005
  • Osteoarthritis has been considered a disease of the elderly because it is uncommon before the age of 40 years and is seen in approximately 80% of United States citizens older than 65 years. general population on kuri city in korea revealed that prevalence of knee osteoarthritis is 10.2%, increasing with age. High level of physical activity in men and age, post-menopause and obesity in women can be risk factor. Osteoarthritis is no evidence that a acquired process initiated much earlier in life through mechanical, metabolic, genetic, or other origins. A high tibial osteotomy alters static lower extremity alignment thereby decreasing medial compartment loading. As well, conservative treatment strategies, such as knee braces and valgus heel wedges, affect lover limb mechanics and attempt to reduce medial compartment loading. It was hypothesized that valgus heel wedges and modified orthoses would shift the center of pressure laterally on the foot during level walking, reducing the moment arm of the adduction moment in the frontal plane, thereby resulting in a decrease in the knee adduction moment. In the 1980s, the effect of wearing a laterally wedged insole on osteoarthritic patients with a varus deformity of the knee was firsted, and since then, kinematic and kinetic analyses concerning this condition have mainly focused on a static standing position. Since the early 1990s, the beneficial effect of wearing a laterally wedged insole to treat osteoarthritis of the knee has also been reported in dynamic conditions, but these studies did not answer the question of the kinematic and kinetic mechanisms that resulted in the reduced symptoms in patents with knee osteoarthritis. therefore, the effect of wearing laterally wedged insole has not been sufficiently studied.

  • PDF

Multidisciplinary approach for a patient with teeth loss and pathologic teeth migration: case report (치아 상실 및 치아의 병적 이동이 일어난 환자의 다과간 협력진료 증례)

  • Gang, Sung-Nam;Kim, Hyung-Moon;Lee, Ji-Young;Son, Mee-Kyoung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.4
    • /
    • pp.329-338
    • /
    • 2014
  • Patients who lost molars from dental caries or periodontitis have difficulty in maintaining their vertical dimension because their incisors and premolars also show vertical tooth movement. Missing posterior molars leads to occlusal interference and collapse of occlusal plane due to extrusion of opposite teeth and tipping of adjacent teeth. When this condition persists over long time, mandible moves forward, so it causes mobility and labioversion of upper incisors. This progress cannot be stopped spontaneously and the situation gets worse and worse. Therefore, for a patient with pathologic teeth migration caused by chronic periodontitis, interdisciplinary approach which is including periodontal treatment, orthodontic teeth alignment and prosthetic restoration of missing molars is required. This case report shows successful multidisciplinary approach to a patient who lost vertical dimension due to severe dental caries and periodontitis.

Radiographic Comparison of Cranial Tibial Wedge Osteotomy versus Tibial Plateau Leveling Osteotomy: A Cadaveric Study

  • Lee, Jiyoon;Kim, Dongwook;Oh, Hyejong;Lee, Sungin;Choi, Seok Hwa;Kim, Gonhyung
    • Journal of Veterinary Clinics
    • /
    • v.39 no.3
    • /
    • pp.93-99
    • /
    • 2022
  • The present study was performed to compare cranial tibial wedge osteotomy (CTWO) and tibial plateau leveling osteotomy (TPLO) through radiographic evaluation. The experiment was conducted with five cadaver dogs [mean (± SD) weight, 32.9 ± 4.1 kg; mean (± SD) age, 6 ± 2 years; three males and two females] euthanized for reasons unrelated to this study. The cadaver dogs consisted of German Shepherd (n = 3), Belgian Malinois (n = 1), and mixed breed (n = 1). CTWO and TPLO were carried out by the standard surgical method. Radiographic evaluation was performed by comparing several factors, including the flexion and extension angles, the anatomical mechanical axis angle (AMA-angle), tibial length, patellar height measurement using the Labelle-Laurin method, mechanical medial proximal tibial angle (mMPTA), mechanical medial distal tibial angle (mMDTA), and frontal plane alignment (FPA). Both the CTWO and the TPLO groups showed significantly increased flexion angles after surgery. Only the CTWO group had significantly increased extension angle. Although both groups showed significant decreases in the AMA-angle, the mechanical axis moved cranially against the anatomical axis only in the CTWO group. The patellar height was significantly lowered in the CTWO group. No significant differences were found in mMPTA, mMDTA, or FPA. In conclusion, radiographic comparison revealed more changes in CTWO group than in TPLO group.

Three-dimensional analysis of the outcome of different scanning strategies in virtual interocclusal registration

  • Jiansong, Mei;Liya, Ma;Jiarui, Chao;Fei, Liu;Jiefei, Shen
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.6
    • /
    • pp.369-378
    • /
    • 2022
  • PURPOSE. The purpose of this in vitro study was to assess whether scanning strategies of virtual interocclusal record (VIR) affect the accuracy of VIR during intraoral scanning. MATERIALS AND METHODS. Five pairs of reference cubes were added to the digital upper and lower dentitions of a volunteer, which were printed into resin casts. Subsequently, the resin casts were articulated in the maximal intercuspal position in a mechanical articulator and scanned with an industrial computed tomography system, of which the VIR was served as a reference VIR. The investigated VIR of the upper and lower jaws of the resin master cast were recorded with an intraoral scanner according to 9 designed scanning strategies. Then, the deviation between the investigated VIRs and reference VIR were analyzed, which were measured by the deviation of the distances of six selected reference points on the upper reference cubes in each digital cast to the XY-plane between the investigated VIRs and reference VIR. RESULTS. For the deviation in the right posterior dentitions, RP group (only scanning of right posterior dentitions) showed the smallest deviation. Besides, BP group (scanning of bilateral posterior dentitions) showed the smallest deviation in the left posterior dentitions. Moreover, LP group (scanning of left posterior dentitions) showed the smallest deviation in the anterior dentitions. For the deviation of full dental arches, BP group showed the smallest deviation. CONCLUSION. Different scanning strategies of VIR can influence the accuracy of alignment of virtual dental casts. Appropriate scanning strategies of VIR should be selected for different regions of interest and edentulous situations.