• Title/Summary/Keyword: pixel differences

Search Result 101, Processing Time 0.027 seconds

System Design and Performance Analysis of 3D Imaging Laser Radar for the Mapping Purpose (맵핑용 3차원 영상 레이저 레이다의 시스템 설계 및 성능 분석)

  • La, Jongpil;Ko, Jinsin;Lee, Changjae
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.90-95
    • /
    • 2014
  • The system design and the system performance analysis of 3D imaging laser radar system for the mapping purpose is addressed in this article. For the mapping, a push-bloom scanning method is utilized. The pulsed fiber laser with high pulse energy and high pulse repetition rate is used for the light source of laser radar system. The high sensitive linear mode InGaAs avalanche photo-diode is used for the laser receiver module. The time-of-flight of laser pulse from the laser to the receiver is calculated by using high speed FPGA based signal processing board. To reduce the walk error of laser pulse regardless of the intensity differences between pulses, the time of flight is measured from peak to peak of laser pulses. To get 3D image with a single pixel detector, Risley scanner which stirs the laser beam in an ellipsoidal pattern is used. The system laser energy budget characteristics is modeled using LADAR equation, from which the system performances such as the pulse detection probability, false alarm and etc. are analyzed and predicted. The test results of the system performances are acquired and compared with the predicted system performance. According to test results, all the system requirements are satisfied. The 3D image which was acquired by using the laser radar system is also presented in this article.

Relative Radiometric Normalization for High-Spatial Resolution Satellite Imagery Based on Multilayer Perceptron (다층 퍼셉트론 기반 고해상도 위성영상의 상대 방사보정)

  • Seo, Dae Kyo;Eo, Yang Dam
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.36 no.6
    • /
    • pp.515-523
    • /
    • 2018
  • In order to obtain consistent change detection result for multi-temporal satellite images, preprocessing must be performed. In particular, the preprocessing related to the spectral values can be performed by the radiometric normalization, and relative radiometric normalization is generally utilized. However, most relative radiometric normalization methods assume a linear relationship between the two images, and nonlinear spectral characteristics such as phenological differences are not considered. Therefore, this study proposes a relative radiometric normalization which assumes nonlinear relationships that can perform compositive normalization of radiometric and phenological characteristics. The proposed method selects the subject and reference images, and then extracts the radiometric control set samples through the no-change method. In addition, spectral indexes as well as pixel values are extracted in order to consider sufficient information, and modeling of nonlinear relationships is performed through multilayer perceptron. Finally, the proposed method is compared with the conventional relative radiometric normalization methods, which shows that the proposed method is visually and quantitatively superior.

Influence of receiver bandwidth on MRI artifacts caused by orthodontic brackets composed of different alloys

  • Abdala-Junior, Reinaldo;No-Cortes, Juliana;Arita, Emiko Saito;Ackerman, Jerome L.;da Silva, Renan Lucio Berbel;Kim, Jun Ho;Cortes, Arthur Rodriguez Gonzalez
    • Imaging Science in Dentistry
    • /
    • v.51 no.4
    • /
    • pp.413-419
    • /
    • 2021
  • Purpose: The aim of this in vitro study was to assess the role of bandwidth on the area of magnetic resonance imaging (MRI) artifacts caused by orthodontic appliances composed of different alloys, using different pulse sequences in 1.5 T and 3.0 T magnetic fields. Materials and Methods: Different phantoms containing orthodontic brackets (ceramic, ceramic bracket with a stainless-steel slot, and stainless steel) were immersed in agar gel and imaged in 1.5 T and 3.0 T MRI scanners. Pairs of gradient-echo (GE), spin-echo (SE), and ultrashort echo time (UTE) pulse sequences were used differing in bandwidth only. The area of artifacts from orthodontic devices was automatically estimated from pixel value thresholds within a region of interest (ROI). Mean values for similar pulse sequences differing in bandwidth were compared at 1.5 T and 3.0 T using analysis of variance. Results: The comparison of groups revealed a significant inverse association between bandwidth values and artifact areas of the stainless-steel bracket and the self-ligating ceramic bracket with a stainless-steel slot(P<0.05). The areas of artifacts from the ceramic bracket were the smallest, but were not reduced significantly in pulse sequences with higher bandwidth values(P<0.05). Significant differences were also observed between 1.5 T and 3.0 T MRI using SE and UTE, but not using GE 2-dimensional or 3-dimensional pulse sequences. Conclusion: Higher receiver bandwidth might be indicated to prevent artifacts from orthodontic appliances in 1.5 T and 3.0 T MRI using SE and UTE pulse sequences.

Functional MR Imaging of Language System : Comparative Study between Visual and Auditory Instructions in Word Generation Task (언어 중추 영역에 대한 기능적 자기공명영상: 시각적, 청각적 지시 과제에 관한 비교)

  • 구은회;권대철;김동성;송인찬
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.241-246
    • /
    • 2003
  • To evaluate the usefulness if functional MR imaging(MRI) for the determination of language dominance system and to assess differences in the visual and auditory instrument language generation task according to activation task or activated area. Functional maps of the language area were obtained during visual and auditory instructions in word generation tasks in 6 healthy volunteer with right-handness were examined on a 1.5T scanner and the EPI BOLD technique, and three pulse sequence technique get of the true axial planes. Both task consisted of 96 phases including 6 activations and rests contents. Postprocessing were done on MRDx program by using cross correlation method. Two task compare the blain activation area surveyed of 1anguage lateralization index. To evaluated of the detection rates of Broca. Wernicke, pre-frontal lobe, Supplementary Motor Area (SMA) and pre-motor cortex areas and the differences of language lateraliaztion among two word generation task To lateralization index survey in 1anguage area on right and left in brain get to activation area pixel in brain. Compared to visual and auditory instrument task in the language areas get to the lateralization index. Two language generation task high detection rates of Broca and Wernicke areas. The visual instruction no detected in the auditory area, and auditory instruction no detected in the visual area. There was statistics significant different of them among language generation task. 1'his indicated that language area obtained image of the brain functional MR imaging usefulness in the visual and auditory task instrument.

An Improved Validation Technique for the Temporal Discrepancy when Estimated Solar Surface Insolation Compare with Ground-based Pyranometer: MTSAT-1R Data use (표면도달일사량 검증 시 발생하는 시간 불일치 조정을 통한 정확한 일사량 검증: MTSAT-1R 자료 이용)

  • Yeom, Jong-Min;Han, Kyung-Soo;Lee, Chang-Suk;Kim, Do-Yong
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.6
    • /
    • pp.605-612
    • /
    • 2008
  • In this study, we estimate solar surface insolation (SSI) by using physical methods with MTSAT-1R data. SSI is regarded as crucial parameter when interpreting solar-earth energy system, climate change, and agricultural production predict application. Most of SSI estimation model mainly uses ground based-measurement such as pyranometer to tune the constructed model and to validate retrieved SSI data from optical channels. When compared estimated SSI with pyranometer measurements, there are some systemic differences between those instruments. The pyranometer data observed upward-looking hemispherical solid angle and distributed hourly measurements data which are averaged every 2 minute instantaneous observation. Whereas MTSAT-1R channels data are taken instantaneously images at fixed measurement time over scan area, and are pixel-based observation with a much smaller solid angle view. Those temporal discrepancies result from systemic differences can induce validation error. In this study, we adjust hour when estimate SSI to improve the retrieved accurate SSI.

Real-Time Video Quality Assessment of Video Communication Systems (비디오 통신 시스템의 실시간 비디오 품질 측정 방법)

  • Kim, Byoung-Yong;Lee, Seon-Oh;Jung, Kwang-Su;Sim, Dong-Gyu;Lee, Soo-Youn
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.3
    • /
    • pp.75-88
    • /
    • 2009
  • This paper presents a video quality assessment method based on quality degradation factors of real-time multimedia streaming services. The video quality degradation is caused by video source compression and network states. In this paper, we propose a blocky metric on an image domain to measure quality degradation by video compression. In this paper, the proposed boundary strength index for the blocky metric is defined by ratio of the variation of two pixel values adjacent to $8{\times}8$ block boundary and the average variation at several pixels adjacent to the two boundary pixels. On the other hand, unnatural image movement caused by network performance deterioration such as jitter and delay factors can be observed. In this paper, a temporal-Jerkiness measurement method is proposed by computing statistics of luminance differences between consecutive frames and play-time intervals between frames. The proposed final Perceptual Video Quality Metric (PVQM) is proposed by consolidating both blocking strength and temporal-jerkiness. To evaluate performance of the proposed algorithm, the accuracy of the proposed algorithm is compared with Difference of Mean Opinion Score (DMOS) based on human visual system.

Rock Joint Trace Detection Using Image Processing Technique (영상 처리를 이용한 암석 절리 궤적의 추적)

  • 이효석;김재동;김동현
    • Tunnel and Underground Space
    • /
    • v.13 no.5
    • /
    • pp.373-388
    • /
    • 2003
  • The investigation on the rock discontinuity geometry has been usually undergone by direct measurement on the rock exposures. But this sort of field work has disadvantages, which we, for example, restriction of surveying areas and consuming excessive times and labors. To cover these kinds of disadvantages, image processing could be regarded as an altemative way, with additional advantages such as automatic and objective tools when used under adequate computerized algorithm. This study was focused on the recognition of the rock discontinuities captured in the image of rock exposure by digital camera and the production of the discontinuity map automatically. The whole process was written using macro commands builtin image analyzer, ImagePro Plus. ver 4.1(Media Cybernetic). The procedure of image processing developed in this research could be divided with three steps, which are enhancement, recognition and extraction of discontinuity traces from the digital image. Enhancement contains combining and applying several filters to remove and relieve various types of noises from the image of rock surface. For the next step, recognition of discontinuity traces was executed. It used local topographic features characterized by the differences of gray scales between discontinuity and rock. Such segments of discontinuity traces extracted from the image were reformulated using an algorithm of computer decision-making criteria and linked to form complete discontinuity traces. To verify the image processing algorithms and their sequences developed in this research, discontinuity traces digitally photographed on the rock slope were analyzed. The result showed about 75~80% of discontinuities could be detected. It is thought to be necessary that the algorithms and computer codes developed in this research need to be advanced further especially in combining digital filters to produce images to be more acceptable for extraction of discontinuity traces and setting seed pixels automatically when linking trace segments to make a complete discontinuity trace.

A New Error Concealment Based on Edge Detection (에지검출을 기반으로 한 새로운 에러 은닉 기법)

  • Yang, Yo-Jin;Son, Nam-Rye;Lee, Guee-Sang
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.39 no.6
    • /
    • pp.623-629
    • /
    • 2002
  • In transmitting compressed video bit-stream over Internet, packet losses cause error propagations in both spatial and temporal domains, which in turn leads to severe degradation I image quality. In this paper, a new error concealment algorithm, called EBMA(Edge Detection based Boundary Matching Algorithm), is proposed to repair damaged portions of the video frames in the receiver. Conventional BMA(Boundary Matching Algorithm) assumes that the pixels on the boundary of the missing block and its neighboring blocks are very similar, but has no consideration of edges across the boundary. In our approach, the edges are detected across the boundary of the lost or erroneous block. Once the orientation of each edge is found, only the pixel difference along the expected edges across the boundary is measured instead of the calculation of difference along the expected edges across the boundary is measured instead of the calculation of differences between all adjacent pixels on the boundary Therefore, the proposed approach needs very few computations and the experiment shows and improvement of the performance over the conventional BMA in terms of both subjective and objective quality of video sequences.

Automatic Liver Segmentation of a Contrast Enhanced CT Image Using a Partial Histogram Threshold Algorithm (부분 히스토그램 문턱치 알고리즘을 사용한 조영증강 CT영상의 자동 간 분할)

  • Kyung-Sik Seo;Seung-Jin Park;Jong An Park
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.3
    • /
    • pp.189-194
    • /
    • 2004
  • Pixel values of contrast enhanced computed tomography (CE-CT) images are randomly changed. Also, the middle liver part has a problem to segregate the liver structure because of similar gray-level values of a pancreas in the abdomen. In this paper, an automatic liver segmentation method using a partial histogram threshold (PHT) algorithm is proposed for overcoming randomness of CE-CT images and removing the pancreas. After histogram transformation, adaptive multi-modal threshold is used to find the range of gray-level values of the liver structure. Also, the PHT algorithm is performed for removing the pancreas. Then, morphological filtering is processed for removing of unnecessary objects and smoothing of the boundary. Four CE-CT slices of eight patients were selected to evaluate the proposed method. As the average of normalized average area of the automatic segmented method II (ASM II) using the PHT and manual segmented method (MSM) are 0.1671 and 0.1711, these two method shows very small differences. Also, the average area error rate between the ASM II and MSM is 6.8339 %. From the results of experiments, the proposed method has similar performance as the MSM by medical Doctor.

Lung/Heart Uptake Ratio in Dipyridamole $^{99m}Tc-MIBI$ Myocardial Perfusion Scan in Coronary Artery Disease (관상동맥질환에서 디피리다몰 부하 $^{99m}Tc-MIBI$ 심근스캔의 폐/심장 섭취율)

  • Kang, Keon-Wook;Lee, Dong-Soo;Choi, Chang-Woon;Lee, Kyung-Han;Chung, June-Key;Lee, Myung-Chul;Seo, Jung-Don;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.2
    • /
    • pp.218-222
    • /
    • 1993
  • Lung/heart uptake ratio (L/H R) in $^{201}Tl$ myocardial perfusion scan is a reliable marker for long-term prognosis in patients with coronary artery disease. However, the value of L/H R in $^{99m}Tc-MIBI$ myocardial perfusion scan is controversial in determining the prognosis and severity of the coronary artery disease. The purpose of this study was to determine the clinical implications of L/H R in $^{99m}Tc-MIBI$ myocardial perfusion scan. Forty five patients who received $^{99m}Tc-MIBI$ myocardial perfusion scan were divided into control group and coronary artery disease (CAD) group by their clinical findings, EKGs, and $^{99m}Tc-MIBI$ myocardial perfusion scans. Twenty five patients in CAD group were divided into ischemic group and infarct group according to their results from $^{99m}Tc-MIBI$ myocardial perfusion scan. L/H R was calculated on the anterior planar view, 60 minutes after infusion of dipyridamole. Two regions of interest (ROI) were placed on the left lung area 8 pixel above the left ventricle and on the myocardial area which had the highest radioactivity. In the control group, there were no significant differences of L/H R according to sex and age. No significant difference of L/H R was found between the control and CAD group ($0.26{\pm}0.06,\;0.29{\pm}0.05$, p>0.05). In the CAD group, there was also no significant difference of L/H R between the ischemic group and infarct group ($0.29{\pm}0.07,\;0.30{\pm}0.04$, p>0.05). L/H R in CAD group did not show correlations with the defect area of stress polar map (r=0.18, p >0.05) and with the sum of severity weighted extent score or reversibility score which represent severity and extent of myocardial perfusion defect area in stress (r=0.18, p>0.05). We conclude that it is difficult to use L/H R as a marker for severity of CAD in dipyridamole $^{99m}Tc-MIBI$ myocardial perfusion scan.

  • PDF